6th European ALARA Network Workshop Madrid, Spain, October 2002

Slides:



Advertisements
Similar presentations
WORKING WITH X-RAYS Dr D E Dugdale October 2012 KEELE UNIVERSITY.
Advertisements

Estimation of TLD dose measurement uncertainties and thresholds at the Radiation Protection Service Du Toit Volschenk SABS.
1 Radiological protection, dosimetry & environmental monitoring National Training Course on Radiopharmacy, Radiochemistry and Radioisotope Production Site.
Detecting and Measuring Ionizing Radiation -2
Safety in Open Source Radioisotope Laboratories  This presentation will introduce you to the theory of radioisotopes and the procedures used in their.
4/2003 Rev 2 II.3.6 – slide 1 of 18 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 6Photographic.
Radiation Detectors / Particle Detectors
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
Space radiation dosimetry and the fluorescent nuclear track detector Nakahiro Yasuda National Institute of Radiological Sciences.
Tumour Therapy with Particle Beams Claus Grupen University of Siegen, Germany [physics/ ] Phy 224B Chapter 20: Applications of Nuclear Physics 24.
Radiation Dosimetry Dose Calculations D, LET & H can frequently be obtained reliably by calculations: Alpha & low – Energy Beta Emitters Distributed in.
Radiation Safety Rules of Thumb. TR-2 Alpha Particle An alpha energy of at least 7.5 MeV is required to penetrate the protective layer of the skin (0.07mm).
4/2003 Rev 2 II.3.1 – slide 1 of 30 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 1Ionization Chambers.
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
THE EXTERNAL HAZARD Radiation Protection.
Photon and Energy Fluence
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
A Radiation Primer radiation … radioactive material What are they? exposure … contamination Are they the same?
Dosimetric evaluation of a new design MOSFET detector Per H. Halvorsen* & Stephanie Parker University of North Carolina.
Radioactivity l Emission of energy from unstable nuclei which are trying to become stable l Natural effect - radioactive isotopes are found everywhere.
IAEA International Atomic Energy Agency Assessment of External and Internal Exposures Michael Hajek Radiation Safety and Monitoring Section Division of.
 Justification is the answer.  Dose limits are not applicable only recommened.
Basic Chemistry Copyright © 2011 Pearson Education, Inc. 1 Chapter 16 Nuclear Radiation 16.1 Natural Radioactivity A person working with radioisotopes.
Fundamentals of Radiation
IAEA International Atomic Energy Agency Radiation Protection Issues in Nuclear Installations (NPP & RR) Laszlo Sagi Radiation Safety and Monitoring Section.
OSL Albedo Neutron Dosimeter
Accurate gamma-ray spectrometry of environmental samples: a challenge O. Sima - Bucharest University D. Arnold - PTB Braunschweig C. Dovlete - ERL Bucharest.
Intervention for Chronic and Emergency Exposure Situations Assessment and Response during Radiological Emergency Dose Assessment Overview Lecture IAEA.
Radiation Protection optimisation 3D planning tools and their applicability to occupational exposure at a fusion power plant F.Vermeersch SCKCEN EFDA 24.
1 Chapter 9 Nuclear Radiation 9.1 Natural Radioactivity Copyright © 2009 by Pearson Education, Inc.
Cosmic rays at sea level. There is in nearby interstellar space a flux of particles—mostly protons and atomic nuclei— travelling at almost the speed of.
Radiation Protection optimisation 3D planning tools and their applicability to occupational exposure at a fusion power plant F.Vermeersch SCKCEN EFDA 27.
RADIATION PROTECTION IN RADIOTHERAPY
Tracking (wire chamber) Shield radon, neutron,  Source foil (40 mg/cm 2 ) Scintillator + PMT 2 modules 2  3 m 2 → 12 m 2 Background < 1 event / month.
International Atomic Energy Agency ASSESSMENT OF OCCUPATIONAL EXPOSURE DUE TO EXTERNAL RADIATION SOURCES AND INTAKES OF RADIONUCLIDES Dosimetry Services.
HP SURVEY INSTRUMENT CALIBRATION AND SELECTION PRINCIPLES OF RADIATION DETECTION AND QUANTIFICATION CHAPTER 5 – REVIEW AND SUMMARY January 13 – 15, 2016.
Photoneutron Distributions around 18 MV X-ray Radiotherapy Accelerators using Nuclear Track Detectors Fazal-ur-Rehman, H. Al-Ghamdi, M. I. Al-Jarallah.
24 th ICNTS Design and test of an albedo personal neutron dosemeter based on PADC detectors R. Bedogni a, A. Esposito a, G. Gualdrini b, R. Mishra c, S.
Radiological Monitoring and Measurement 1 OBJECTIVES Allow the participants to understand the concepts of measuring dose received by radiation workers.
Barcelona, January 2011 Workshop on optimization of Radiation Protection of Medical Staff O RAMED SPECIFIC TRAINING MODULE FOR NUCLEAR MEDICINE This.
Enhancement of Radiological Safety Culture within Ignalina NPP and Contractors Viktor PLETNIOV Ignalina Nuclear Power Plant Lithuania Gintautas KLEVINSKAS.
Radiation Protection RTMR 284 CHAPTER 20 PART II.
Radioactivity Emission of energy from unstable nuclei which are trying to become stable Natural effect - radioactive isotopes are found everywhere. Radiation.
Lessons learned from the surveillance: Measuring methods and monitoring strategies T. R. Beck, E. Ettenhuber Federal Office for Radiation Protection, Germany.
EUROPEAN ALARA NETWORK
Topic 6 : Atomic and Nuclear Physics.
Austrian Research Centers Seibersdorf
Occupational Radiation Protection during High Exposure Operations
Electron Beam Therapy.
RADIOLOGICAL PROTECTION STAKES IN THE RADIOPHARMACEUTICAL INDUSTRY
AUBERT Bernard*, GUILABERT Nadine°, LAMON Annick* and RICARD Marcel*
Basic requirements on area dosemeters
Catalina Chitu, Vasile Simionov, “CNE-PROD Cernavoda” NPP, Romania
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
First FRCR Examination in Clinical Radiology Diagnostic Radiology & Radionuclide Radiology (4b) Patient Dosimetry John Saunderson Radiation Protection.
On behalf of the GECAM group
Chapter 9 Nuclear Radiation
Uses of radioactive sources
Summary of alpha etc.
Chapter 9 Nuclear Radiation
Occupational Radiation Dose Management
The dangers of radioactivity
First FRCR Examination in Clinical Radiology Diagnostic Radiology & Radionuclide Radiology (4b) Patient Dosimetry John Saunderson Radiation Protection.
Uses of radioactive sources
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
F. Schartmann, S. Thierfeldt Brenk Systemplanung GmbH, Aachen
G. Valtchev, M. Neshkova, A. Nikolov Nuclear Power Plant Kozloduy
Hp(10) irradiations for personal dosimetry traceability
 To provide an overview of external and internal dosimeters used for accupationl radiation protection 
 To provide an overview of external and internal dosimeters used for accupationl radiation protection 
Presentation transcript:

6th European ALARA Network Workshop Madrid, Spain, 23 -25 October 2002 Problems at the development of personal beta-particle dosemeters Klaus Helmstädter and Peter Ambrosi Physikalisch-Technische Bundesanstalt Braunschweig, Germany

Analysis of beta workplaces Beta partial body dosemeter Contents Beta workplaces Analysis of beta workplaces Beta partial body dosemeter PTB intercomparisons Response of partial body dosemeters with TLD Problems in practical operation of TL dosemeters Electronic personal dosemeter Area monitoring dosemeters Conclusions

Beta workplaces Nuclear power plants: Industrial applications: Contamination of surfaces and room air maximum beta energies from 0,1 MeV to 3,5 MeV Industrial applications: Production and use of radioactive sources Example of use: Measurements of string and paper thickness Radiation therapy: Treatments of eye tumors Treatments of coronary arteries after a balloon dilatation (Intravascular Brachytherapy, IVB) Treatments of inflammatory joint deseases (Radiosynoviorthesis, RSO)

Analysis of beta workplaces Exposures measured by Mielcarek and Barth: Daily 1.4 mSv in the production of eye applicators of the nuclide Ru-106/Rh-106 More than 100 mSv in the preparation and use of radioactive solutions for IVB and RSO Conclusions drawn by Mielcarek and Barth: Optimisation of radiation protection Introduction of legal beta-particle dosemeter (partial body) Training and information of the personnel Exchange of experience

PTB intercomparisons PTB intercomparison in 1996: 10 TL-Dosemeters, compared for mean beta energies from 60 keV to 800 keV and different angles of incidence PTB intercomparison in 1998/1999: 5 selected TL-Dosemeters (TD1 to TD5), compared for mean beta energies from 60 keV to 800 keV, for mean photon energies from 8.9 keV to 662 keV, for different angles of incidence and in mixed beta / photon fields

Beta partial body dosemeter (finger rings) TD1 TD3 TD4 TD2 TD5

Response Hpt/HPTB for photon radiation

Response Hpt/HPTB for beta radiation 2 1,8 1,6 1,4 1,2 H pt PTB 1 0,8 0,6 0,4 0,2 Pm-147; 1 mSv/0° Pm-147; 10 mSv/0° Pm-147; 10 mSv/45° Pm-147; 10 mSv/60° Pm-147; 100 mSv/0° Kr-85; 1 mSv/0° Kr-85; 10 mSv/0° Kr-85; 10 mSv/45° Kr-85; 10 mSv/60° Kr-85; 100 mSv/0° Sr-90; 1 mSv/0° Sr-90; 10 mSv/0° Sr-90; 10 mSv/45° Sr-90; 10 mSv/60° Sr-90; 100 mSv/0° TD1 TD2 TD3 TD4 TD5 LL UL

Response Hpt/HPTB for mixed beta/photon radiation

Problem with Pm-147 Inconsistent results in different intercomparisons 60° 45° 0°

Problems at practical operation of TLD Non-uniformity of the TL material distribution inside the detector Inhomogenity of the covering mylar foil Thin TL material with high sensitivity required. Thin TL material requires cautious handling. Discrepancy between the wearing place and the position of maximum exposure Standard photon rings are not suitable for beta measurements

Electronic personal dosemeter (EPD)

Electronic personal dosemeter (EPD) Detector: semiconductor behind a thin entrance window Measuring quantity: personal dose equivalent to the skin Hp(0.07) (directional dose equivalent H´(0.07)). Response: acceptable compared to TLD detectors (Hp(0.07)) and ionisation chambers (H´(0.07)). Drawback: Dosemeters are worn on the chest and cannot estimate the exposure of the finger tip.

Response Hpt/HPTB for beta radiation (EPD, TLD, IK)

Area dosemeters with ionisation chambers

Area dosemeters with szintillation detectors

Investigations on area dosemeters Scintillation detectors are unsuitable for beta dose rate measurements also for Sr-90/Y-90. Ionisation chambers with thin walls can measure acceptable beta dose rates even for low energy beta radiation. The typically large measuring volume is a problem because of the decay of the dose rate within the detector. Therefore, measurements are only useful at distances greater than 50 cm from the source.

Problem: Detector size

Conclusions Optimisation of detector cover thickness Suitable beta particle dosemeters (partial body) exist but they need to be improved with regards to: Optimisation of detector cover thickness Wearing comfort Robustness and sterilisability Acceptability to the personnel Area monitoring dosemeters should be developed with semiconductor detectors: Small dimensions High sensitivity Spectrometric and dosimetric analysis of workplaces is necessary to find the relation between the place of maximum exposure and the dosemeter wearing position.

Standard photon rings with TLD in beta fields Standard photon rings were calibrated in beta radiation fields of 85Kr and 90Sr/90Y sources. The response decreases from about 1 for 90Sr / 90Y at 0° incidence to 0.4 at 60° incidence and to 0.2 for 85Kr at all angle of incidence. High-energy beta fields are always accompanied by low-energy components behind the shielding which would be underestimated. For photon rings in beta fields the measurement value 0 therefore does not necessarily imply that there is no beta radiation at all. Especially behind the shielding, a significant contribution to the personal dose equivalent to the skin could be caused by low-energy beta radiation. Standard photon rings cannot be used for beta dose measurements

Standard photon rings with TLD in beta fields

Beta measurements with and without cap 1 Szintillation detectors 0,1 M with M 0,01 without Ionisation chambers 1E-3 200 400 600 800 keV 1000 Mean beta energy

Technical data of beta-particle dosemeters (partial body)