Blower-/Fan Coil-Actuator

Slides:



Advertisements
Similar presentations
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
Advertisements

STAND ALONE CONTROL FOR TERMINALS
EUT 1040 Lecture 10: Programmable Logic Controllers.
Siemens Building TechnologiesRWD heatpump controllers Xavier Zabalegui/David Jefferson 1 January 2003 RWD Heat Pump controllers RWD Heat Pump Controllers.
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
Air Conditioning Heating Refrigeration
Control Technology and Automation
Applied Systems News FWEC*A Rudolf BARET HEISSIG.
© ABB Stotz-Kontakt GmbH 1 21-Nov-15 KNX and Energy Efficiency Gareth Rowlands ABB LTD.
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Fan Coils Units Control
HVAC Wiring diagram 5 channel output (5A relay) Speed: High/Medium/Low Mode: Cooling / Heating /Dehumidifier HVAC is a module specially for Air Conditioner.
Arduino based Automatic Temperature Controlled Fan Speed Regulator.
ABB i-bus® EIB Shutter Actuators
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
ABB i-bus® KNX Fan Coil Actuator FCA/S
Fan Coil Actuator FCA/S 1.x.x.2
Lecture 10: Programmable Logic Controllers
Air-Condition controller
Fan Coil Controller FC/S 1.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Weather Unit, Weather Sensor
G. Schlag / STO-GM / Novembre 2012
DALI-Gateway DG/S 1.1.
ABB STOTZ-KONTAKT GmbH DALI-Gateway DG/S
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
Room Controller RC/A 8.1 Room Controller economic flexible modular.
automatic recognition of load-type superior functionality
FCU Controller M/FCU
DALI-Gateway DG/S 8.1.
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
FLoor Heating Controller
ABB i-bus® KNX Weather Station
Text آشنایی بیشتر با کنترلر هوشمند زیمنس
ABB i-bus® KNX Valve Drive Actuator VAA/A
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
Dimmer 6fold 10V Actuator M/DA
ABB i-bus® KNX Fan Coil-Actuator FCA/S 1.1M
ABB i-bus® KNX Room Solutions
Universal Interface, 4-fold, FM, US/U 4.2
ABB i-bus® EIB Display and Control Tableau
ABB i-bus® EIB / KNX Thermoelectric Valve Drive TSA/K , TSA/K 24
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
FLoor Heating Controller
ABB i-bus® EIB Electronic Switch Actuator, 4-fold
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
What is meant by ‘Preventive Monitoring’?
DMX512 Gateway M/DMX512.1.
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
Jörn Kruse / STO-G / Mai 2009 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX The „smaller“ Room Controller RC/A 4.2 © STO/G - Slide 1.
ABB i-bus® EIB / KNX Elektromotor Valve Drive ST/K 1.1
Curtain Actuator M/W
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
ABB i-bus® EIB / KNX Fault Monitoring Unit SMB/S 1.1
ABB i-bus® EIB / KNX USB Interface
EIB Power Supply, 160 mA SV/S
ABB i-bus® EIB Logic Module LM/S 1.1
ABB i-bus® KNX Analogue Input
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
Control System Instrumentation
Universal Dim Actuator UD/S
ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
Automotive Technology Principles, Diagnosis, and Service
The efficient interface for lighting control
Presentation transcript:

Blower-/Fan Coil-Actuator ABB i-bus® EIB / KNX LFA/S x.1 Blower-/Fan Coil-Actuator

Blower-/Fan Coil Actuators Blower- and Fan Coil Actuators are basic devices in HVAC Completion of the ABB i-bus® EIB / KNX range with two actuators Control of 3- or 5 speed fans No integrated controller to regulate the room temperature Control values sent by external components like room thermostat or EIB/KNX push button

Blower-/Fan Coil Actuators, LFA/S x.1 LFA/S 1.1, MDRC, 1fold (1 Fan) LFA/S 2.1, MDRC, 2fold (2 Fans) LFA/S 1.1 LFA/S 2.1

Hardware LFA/S x.1 Compact component with 2 outputs per module LFA/S 1.1 LFA/S 2.1 Compact component with 2 outputs per module No manual operation in order to exclude damage of fan 1fold actuator for 3 level Fan control 2fold actuator for two 3- or one 5 level Fan control

Blower-/Fan Coil Actuators, LFA/S x.1 LF/A x.x receives input signal via EIB / KNX Manual Operation 1Bit object for each fan speed 1Byte object for any fan speed 1Bit object for going up/down Automatic Control Temperature detection and regulation via room thermostat Control output Heating and / or Cooling Switching between Heating / Cooling

Blower-/Fan Coil Control Types of Fan control (3- and 5 speed) Control via toggle switch (3 steps) Control via switch (3 steps) 1 2 3

Parameterisation Fan Toggle switch or switch Start up behaviour (direct or any fan speed) Waiting time between switching Minimum time in a level Threshold for switching to another speed Hysterese Object fan status e.g. for activation of an external fan or a fan main switcher

Control of a valve via LFA/S x.1 LF/A x.1 generates additional control signals for heating- and / or cooling valves Control Signal available as an EIB / KNX communication object  High flexibility regarding switching load, life span and noise Valve objects will be set to „1“ or „0“ depending on the control output (heating / cooling)

Forced control and operating modes LFA/S x.1 Separate Fan- and Valve limitation Limitation to a speed level or to a speed range Activation via 1Bit or 1Byte objects Forced control (only 1 Bit object) e.g. Frost / Heat protection Comfort mode Night mode Standby mode Automatic mode

Additional functions LFA/S x.1 Monitoring of room thermostat with adjustable fault operation Function of fan and valve adjustable in case of bus voltage failure (unchanged or OFF) and recovery (variable) Status Byte for indication of operating mode Separate feedback of required and real fan speed

Free channels of „Switch Actuator“ LFA/S x.1 Functionality of a Switch Actuator ON / OFF Time function (Staircase light) - Time for staircase light via EIB/KNX changeable - Time function can be enabled /disabled via EIB/KNX - No warning

Free channels of „Switch Actuator“ LFA/S x.1 Valve Control Same functionality as the heating actuator SA/S Continuous control (1Byte) or 2-step control (1Bit) Valve normally closed or open Forced operation Monitoring of room thermostat Functionality flushing

Circuit Diagram Blower and Fan Coil actuator

Separate Cool and Heating Circuits Principle Fan Coil Unit Example: Fan Coil Unit, 4 – pipe system 2 Heat exchanger for Heating and Cooling Motor Fan 2 Heat exchanger 2 Valves Separate Cool and Heating Circuits