AUBERT Bernard*, GUILABERT Nadine°, LAMON Annick* and RICARD Marcel*

Slides:



Advertisements
Similar presentations
THE EXTERNAL HAZARD.
Advertisements

PET Radiation Safety Robert E. Reiman, MD, ABNM Radiation Safety / OESO Duke University Medical Center Academy of Molecular Imaging.
Iodine 125.
King Abdul-Aziz University Diagnostic Radiology Department MS.Nouf Al-Zahrani DR. Saddiq Jastniah Introduction to Nuclear Medicine 2 nd year.
Radiation Detection Systems
Detecting and Measuring Ionizing Radiation -2
Safety in Open Source Radioisotope Laboratories  This presentation will introduce you to the theory of radioisotopes and the procedures used in their.
IAEA International Atomic Energy Agency Personal Protection Day 9 – Lecture 5.
Radiation Detectors / Particle Detectors
Development of [NH 3 ] Ammonia target for Cyclone-30 at KFSH&RC F. Alrumayan, A. Alghaith, Q. Akkam, A. Marsood, A. Hendy and M. AlQahatani KFSHRC, RIYADH.
Calibration of extremity dosimeters for Tc-99m, Cs-137 and X-ray David Rawlings Regional Medical Physics Department Newcastle-upon-Tyne.
Radiation Safety Oversight of Surgical Procedures Involving the Use of RAM René Michel, M.S., RSO VA San Diego Healthcare System, San Diego, CA.
Gauges and well logging
03/07/2015radiation safety - level 51 Radiation safety level 5 Frits Pleiter.
Alanoud M. Al-Talal Office – Pharmacy Building (8) – 2 nd Floor – Room 63 address –
Technetium-99m generator
. 2 RCRS provides: Pick-up and delivery of meters Required 9-month calibration Preventive maintenance and repairs Shipping for extensive repairs RCRS.
Radioisotopes in Medicine
RADIATION SAFETY Phil Facey Lead Superintendent Radiographer
THE EXTERNAL HAZARD Radiation Protection.
Photon and Energy Fluence
Occupational Exposure Protection of the Worker Lab # 6.
Geant4 simulation of the attenuation properties of plastic shield for  - radionuclides employed in internal radiotherapy Domenico Lizio 1, Ernesto Amato.
Introduction to Nuclear Medicine
Radioactivity Chapter 21  Natural occurring phenomena.  In the nucleus of an atom there are protons and neutrons. Protons are positively charged so they.
CLRS 321 Nuclear Medicine Physics & Instrumentation I Part C: Semiconductors and Miscellaneous Scintillation Devices Unit II: Nuclear Medicine Measuring.
IAEA International Atomic Energy Agency Assessment of External and Internal Exposures Michael Hajek Radiation Safety and Monitoring Section Division of.
 Justification is the answer.  Dose limits are not applicable only recommened.
Occupational Exposure Protection of the WorkerOccupational Exposure Protection of the Worker Lab # 6.
Nuclear Medicine Quality control.
CT physics and instrumentation
Hot Lab 11. dose calibrator, an ionization chamber used in nuclear medicine to measure the amount of radioactivity of a radionuclide before injection.
Dr. Mohammed Alnafea RADIATION PROTECTION IN NUCLEAR MEDICINE.
Đ. Milković, M. Ranogajec-Komor, S. Miljanić, Ž. Knežević and K
Basic radiation protection & radiobiology
 Radiopharmaceuticals are agents used to diagnose certain medical problems or treat certain diseases. They may be given to the patient in several different.
1 By Maribel Aguilar. 2 What is Gallium Scan?  Type of nuclear medicine that uses radioactive tracers.  Radioactive tracers common use in gallium scan.
Introduction to nuclear medicine technology NMT 231.
Isotope Technologies Garching GmbHCERN 2010 Radiation Protection Aspects Related to Lutetium-177 Use in Hospitals R. Henkelmann, A. Hey, O. Buck, K. Zhernosekov,
Introduction to nuclear medicine technology NMT 231 Aya Ahmed Saeed.
Determining Radiation Intensity
M.Moll, M.Silari, H.Vincke – 3.April Mixed field irradiation -- Who answered ?  In total 36 forms filled / 34 persons answered: 38% 62% CERN:
TLD POSTAL DOSE QUALITY AUDIT FOR 6MV AND 15MV PHOTON BEAMS IN RADIOTHERAPY CLINICAL PRACTICE Sonja Petkovska 1, Margarita Ginovska 2, Hristina Spasevska.
Radiopharmaceutical Production Radioassay STOP. Radiopharmaceutical Production Radioassay Example STOP Radioassay Acceptance Criteria: The product label.
Barcelona, January 2011 Workshop on optimization of Radiation Protection of Medical Staff O RAMED SPECIFIC TRAINING MODULE FOR NUCLEAR MEDICINE This.
Radiation Safety Refresher Training for PET Imaging For Record of Attendance or Interoffice Mail Test to: Stephen David,
AAPM TG-51 Protocol (Med Phys 26: , 1999)
Training Module Preparation for “AERB norms, licenses and signage”
HOW TO PROTECT YOUR HANDS IN NUCLEAR MEDICINE WORK
The environmental dose measurements of high dose Iodine-131 treated thyroid cancer patients during hospitalization period Nina TUNÇEL  Department of Physics,
Topic 6 : Atomic and Nuclear Physics.
 Usefulness of  Radiopharmaceuticals Auto   Injection System (RAIS) in the PET study Jeom jin Lim Seoul National University Hospital.
Austrian Research Centers Seibersdorf
Beam quality correction factors for linear accelerator with and without flattening filter Damian Czarnecki1,3, Philip von Voigts-Rhetz1, Björn Poppe3,
6th European ALARA Network Workshop Madrid, oct. 23rd 2002
6th European ALARA Network Workshop Madrid, Spain, October 2002
JM Martí-Climent, I Peñuelas
Dr: Mohamed Afifi By Lecturer Radiological Science
Gas Detectors for Neutron Dosimetry and Monitoring
Overview of Nuclear Technologies in Healthcare
X-Radiation.
What is an isotope? Agenda for Tuesday Feb 8th Percent composition
CLRS 321 Nuclear Medicine Physics & Instrumentation I
Lecture 4(Unit II): Gas-Filled Detector Quality Control
DOSIMETRY MEASUREMENT FOR INDUSTRIAL DEVELOPMENT
Radioisotopes in Medicine
CLRS 321 Nuclear Medicine Physics and Instrumentation 1
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
G. Valtchev, M. Neshkova, A. Nikolov Nuclear Power Plant Kozloduy
The External Radiation Hazard
Presentation transcript:

Which protection against radiation from new protocols of internal dosimetry by yttrium-90 AUBERT Bernard*, GUILABERT Nadine°, LAMON Annick* and RICARD Marcel* *Physics Department and °Nuclear Medicine Department Institut Gustave-Roussy, Villejuif, France 6th European ALARA Network Workshop - Madrid, 23-25/10/2002

Introduction Within the field of the therapeutic applications in Nuclear Medicine, new protocols have been proposed these last years based on the use of therapeutic agents labelled with yttrium-90 : Octreother° (somatostatine analogue) on patients with neuro-endocrines tumors. Zevalin* for treatment by radio immunotherapy of non Hodgkiniens lymphoma. ° Mallinckrodt * Schering

Yttrium 90 - ( 100 %) T1/2 = 64.1 hours Rmax (air ) : 9 m Rmax (water) : 11 mm R90 (water) : 5.3 mm

Introduction iode 131 : beta emitter (Emax  0.6 MeV) used since more than 50 years for treatment of thyroid diseases and gamma emitter (Eprincipal = 0.365 MeV): Radiation protection procedures are well known even for high activities ( 8 GBq). Other used beta emitters: erbium 169 (Emax  0.35 MeV) rhenium 186 (Emax  1 MeV) Applications not very wide spread and using low activity ( 0.1 GBq).

Aim of the study Recommandations for radiation protection for beta emitters are very general: 10 mm of PMMA are enough to stop any beta emission, PMMA is preferable to lead (or tungsten) because the bremsstrahlung emission is less important. Systematic analysis of exposure situations at the beginning, or before starting, clinical protocols with yttrium-90 by: procedure analysis, choice of radiation protection material, and, additional dosimetric survey.

71.1 µSv.h-1.GBq-1 43.5 Sv.h-1.GBq-1 Radiation Protection Dosimetry, Vol. 98, No 1, 2002

Additional personal dosimeter TLD chips Electronic dosimeter

OCTREOTHER protocol Solution of 5.4 GBq (145 mCi) of 90Y in 86 mL Activity measured with a dose calibartor Radioactive vial placed inside the injection container

OCTREOTHER protocol Installation of the line Connection of the line to the patient Installation of the line in the electrical pump Injection of 4.44 GBq (120 mCi) by perfusion during 12 to 15 minutes

OCTREOTHER protocol Surveillance of injection Collection of vial and line and management of radioactive wastes Surveillance and patient care during 2 days

OCTREOTHER protocol Exposure measurements with portable ionisation chamber Close to the delivery container and injection container (at  5 cm):  300 µSv/h. at 1 m from containers:  2 à 3 µSv/h Before injection : After injection at 1 m from patient:  30 à 40 µSv/h near the second pump (for amino acides) managed by the nurse:  120 µSv/h

Finger exposure in mSv/injection TLD measurement - mean value (SD) OCTREOTHER protocol Finger exposure in mSv/injection TLD measurement - mean value (SD) Localization Technologist 1st injection right thumb 18.0 right forefinger 23.5 left foerfinger 14.5 left thumb 14.0 After new procedure Technologist (15 inject.) Nurse 2.81 (2.13) 0.40 (0.56) 2.36 (2.58) 0.28 (0.50) 2.12 (0.74) 0.42 (0.58) 1.6 0.20 (0.32)

(dose rate at 1 m: 1.5 to 2 µSv/h). OCTREOTHER protocol NaI(Tl) probe Bremsstrahlung spectrum from patient one day after injection of 4.44 GBq of 90Y (dose rate at 1 m: 1.5 to 2 µSv/h).

OCTREOTHER protocol Due to the importance of low energy components in the bremsstrahlung spectrum (max at  80 keV and very few photons above 300 keV), a protective apron (0.5 mm Pb equivalent ) is efficient. Measurement with portable ionization chamber (RAM DA 2000) Patient 1 (at 50 cm) Patient 2 (at 65 cm) without apron 360 59.1 with apron 4.8 1.0 (µSv/h)

ZEVALIN protocol Radionuclide preparation. Injection of 1.11 GBq (30 mCi) with an automatic syringe pump during 10 minutes. Surveillance of injection. Collection of vial and line, and management of radioactive wastes. Surveillance and patient care during 2 days.

ZEVALIN protocol Radiopharmaceutical preparation Solution of 1.85 GBq (50 mCi) of 90Y in 2 mL. Measurement of activity with a dose calibrator. Removal of 90Y from delivery vial and transfer into preparation vial. Filling of infusion syringe.

ZEVALIN protocol Efficiency of vial shield Wall in lead glass and size adaptator in PMMA Close to the shielding:  70 µSv.h-1.GBq-1

ZEVALIN protocol Syringe shield Tungsten  5 mm PMMA 5 and 10 mm

ZEVALIN protocol Efficiency of syringe shield - TLD measurements This study 5.5 ZIMMER* study 11.2 Contact syringe (mSv.h-1.MBq-1) Contact with syringe shield (µSv.h-1.MBq-1) PMMA-5 mm PMMA-10 mm tungsten-5 mm 16 2.7 1.4 PMMA PMMA/Pb tungsten 2.8 1.7 2.4 * Zimmer et al., abstract n° 164, J.N.M. abstract book, may 2002

Conclusions This radiation protection study concerning new therapeutic protocols with 90Y confirmed: the need for studies related to working conditions before the starting of new clinical protocols, the interest of additional dosimetry at the most exposed regions (fingers), the interest of operational dosimetry for the direct information of the operator,

Conclusions the need for electronic dosemeters suited to the situation, i.e. sensitive to the beta radiation, the need to collaborate with the manufacturer to increase its awareness of this problem in order to inform users before starting the clinical protocol, the contribution of a radiation protection culture in a hospital where the human and material means are available.