MARK RIDGWELL, DIASUKE TANAKA & CCG WOOD Within run Imprecision

Slides:



Advertisements
Similar presentations
Practical Clinical Hematology. Introduction HBA 2 is a protein which in humans is encoded by the HBA 2 gene. Hemoglobin A 2 is a normal variant of hemoglobin.
Advertisements

Hemoglobin A 2 Practical Hematology Lab - LAB 6 -.
World Health Organization
L MACKAY, N CRINIS, Q LAM, R SCOTT
Titremetric analysis Dr. Mohammad Khanfar. Concept of Titremetric analysis In general, we utilize certain property of a substance to be analyzed in order.
BOHB APCCB LABORATORY USE OF THE ABBOTT MEDISENSE METER FOR BETA-HYDROXYBUTYRATE MEASUREMENT. GRD Jones, A Screnci, P Graham Chemical Pathology,
Chemometrics Method comparison
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
Unit #7 - Basic Quality Control for the Clinical Laboratory
Quality Assurance.
Quality Assessment 2 Quality Control.
Method Selection and Evaluation Method Selection and Evaluation D. Kefaya EL- Sayed Mohamed Prof. Of Clinical Pathology (Clinical Chemistry), Mansoura.
ABC of Quality Control A problem based approach RT ERASMUS NHLS / FACULTY OF HEALTH SCIENCES, UNIVERSITY OF STELLENBOSCH 20th July, 2007, Bela Bela.
Changing Values. When does 6.5 = 48? Is this a well controlled diabetic? DateHbA1c mmol/mol 23/04/ /11/ /01/ /11/ /09/
Analytical considerations
Estimation of blood glucose in diabetes mellitus.
© Copyright 2009 by the American Association for Clinical Chemistry Glucose Meter Performance Criteria for Tight Glycemic Control Estimated by Simulation.
Biochemical tests in diabetes HBA1c standardization Dr Javad Mohiti Dept of Clinical Biochemistry.
Biostatistics: Measures of Central Tendency and Variance in Medical Laboratory Settings Module 5 1.
What is Analytical Chemistry?
Quality Control Lecture 5
G Jones, M Roser Department of Chemical Pathology
BNPCV APCCB BIOLOGICAL VARIATION FOR N-TERMINAL PRO-BNP Jones GRD 1, Bennett A 2,3, Boscato L 1, Macdonald P 2, Brien J 3. Departments of Chemical.
1 Immunoassay Testing Forensic Toxicology. 2 Introduction Antibody/Antigen reaction provides the means of generating a measurable result. “Immuno” refers.
Interferences - are some methods better than others? Graham Jones Department of Chemical Pathology St Vincent’s Hospital, Sydney.
Comparability of methods and analysers Nora Nikolac
Lecturer: Bahiya Osrah.  It is a chronic disease associated with hyperglycemia (increased blood glucose level) & glucourea (presence of glucose in urine)
Patient Safety Monitoring in International Laboratories (SMILE) Mark Swartz, MT(ASCP), SMILE QA/QC Coordinator Improving the Sensitivity of QC Monitoring:
Chapter 1: The Nature of Analytical Chemistry
Whole blood was the sample of choice for analysis However, values for glucose in whole blood are less than in plasma since red blood cells contain only.
Zinc and Copper Analysis by Colourimetry By Carolyn Fahm TEQAS ~ Trace Elements External Quality Assessment Scheme S: External Quality Assessment.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Evaluation of IgG Subclass assays on the Radim Delta
Practical Hematology Lab
Unit #6 - Basic Quality Control for the Clinical Laboratory
Pakistan Society Of Chemical Pathologists Zoom Series of Lectures ZT 24. Quality Managent 1 Brig Aamir Ijaz MCPS, FCPS, FRCP (Edin), MCPS-HPE HOD and.
BLOOD OR PLASMA GLUCOSE
Estimation of blood glucose in diabetes mellitus
Evaluation of the Tosoh Bioscience 25OH vitamin D assay
EVALUATION OF HEMOCHROMA POC Hb READER
World Health Organization
Mass Spectrometry Vs. Immunoassay
P.J. Showell1, E.A. Lynch1, H.D. Carr-Smith1, A.R. Bradwell2
Fluorescence Polarization Immunoassay FPIA
Labeled Immunoassays.
Robust Measurement of Branched Chain Amino Acids on the Vantera Clinical Analyzer and the Clinical Association of NMR-Measured Valine with Type 2 Diabetes.
ASSESSMENT OF GOLD NANOPARTICLE BASED CORTISOL STRIPS TO ASSIST CATHETERISATION DURING BILATERAL ADRENAL VEIN SAMPLING: A ROYAL NORTH SHORE PERSPECTIVE.
Precision Albumin (mg/L) (Mean ± SD) % CV Intra-assay (n = 10)
Unexpected Hemoglobin A 1c Results Dr.M.KOTTESWARAN 1 ST YEAR BIOCHEMISTRY PG.
Laboratory Quality Control
Blood Glucose Test By Fifth Stage Student 18 Dr. Sakar Karem Abdulla
Practical clinical chemistry
Measurement of Analytes
Glycated hemoglobin (HbA1c)
Practical Clinical Hematology
Choice of Methods and Instruments
Chapter 1: The Nature of Analytical Chemistry
Fig. 1. Glycemic variability in three hypothetical patients who have the same mean blood glucose concentration. Patient B has relatively small variations.
Method Selection and Evaluation
Glycated hemoglobin (HbA1c)
World Health Organization
Introduction To Medical Technology
Quality Control Lecture 3
Hba1c for diagnosis Dr Karen Adamson.
▪Internal quality control:
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
AEROSET® & ARCHITECT® c8000® OEM Reagent Training
ARCHITECT cSystems OEM Reagent Training
A proposal for Derivation of Analytical Quality Goal for Precision
Hemoglobin A1c- The What….. The Why….. The How…..
Presentation transcript:

MARK RIDGWELL, DIASUKE TANAKA & CCG WOOD Within run Imprecision COBAS C111 – EVALUATION OF HBA1C PERFORMANCE AND SUITABILITY OF USE IN A CLINICAL SETTING MARK RIDGWELL, DIASUKE TANAKA & CCG WOOD This is a template for Kolling posters designed for 4 A2 sheets (840x120cm). Sample data taken from Anne Nelson. Vic Danis 24/9/98 INTRODUCTION Inter/Intra-assay variation of High pool HbA1c results measured on the Roche Cobas C111(DCCT/NGSP) Haemoglobin A1c (HbA1c) also known as glycosylated or glycated haemoglobin, is a product of the non-enzymatic reaction of haemoglobin with glucose in blood. This reaction occurs to a small extent in normal blood (approximately 5% of total haemoglobin is in this form in normal subjects). Higher levels are found in patients with poorly controlled diabetes mellitus, due to higher glucose concentrations in their blood. Hence, the percentage of haemoglobin in the glycosylated form is a useful indicator of metabolic control in these patients. Due to the long half-life of haemoglobin (6 weeks approx) the percent HbA1c changes slowly and tends to indicate the "integrated" glucose concentration for a period of at least one month. The Cobas C111 analyser is suitable for small workload laboratories and offers solutions for clinical chemistry and homogenous immunoassay testing. The analyser is a bench top unit with a width of 720mm and a weighty of 35kg and offers both photometric and ISE chemistry testing. HbA1c in whole blood is part of the test menu. We evaluated the analytical performance of the HbA1c method and the analysres suitability of use in a clinical setting. Run Date Replicate 1 Replicate 2 Replicate 3 1 27/09/2010 8.40 8.20 2 29/09/2010 8.30 3 30/09/2010 8.00 4 1/01/2010 8.10 5 6/10/2010   Within run Imprecision Total imprecision %HbA1c 0.09 0.12 CV 1.10% 1.40% RESULTS Merhod comparison difference plot Biorad variant II v Roche Cobas C111(DCCT/NGSP) Merhod comparison scatter plot with Passing and Bablok fit Biorad variant II v Roche Cobas C111(DCCT/NGSP) r2=0.98 n=215 METHOD This method uses TTAB* as the detergent in the hemolyzing reagent to eliminate interference from leukocytes (TTAB does not lyse leukocytes). Sample pretreatment to remove labile HbA1c is not necessary. All hemoglobin variants which are glycated at the β-chain N-terminus and which have antibody-recognizable regions identical to that of HbA1c are measured by this assay. Consequently, the metabolic state of patients having uremia or the most frequent hemoglobinopathies (HbAS, HbAC, HbAE) can be determined using this assay. The HbA1c determination is based on the turbidimetric inhibition immunoassay (TINIA) for hemolyzed whole blood. Sample and addition of R1 (buffer/antibody): Glycohemoglobin (HbA1c) in the sample reacts with anti-HbA1c antibody to form soluble antigen-antibody complexes. Since the specific HbA1c antibody site is present only once on the HbA1c molecule, complex formation does not take place. Addition of R2 (buffer/polyhapten) and start of reaction: The polyhaptens react with excess anti-HbA1c antibodies to form an insoluble antibody-polyhapten complex which can be measured turbidimetrically. Liberated hemoglobin in the hemolyzed sample is converted to a derivative having a characteristic absorption spectrum which is measured Bichromatically during the preincubation phase (sample + R1) of the above immunological reaction. A separate Hb reagent is consequently not necessary. The final result is expressed as percent HbA1c and is calculated from the HbA1c/Hb ratio as follows: Protocol 1 (acc. to IFCC): HbA1c (%) = (HbA1c/Hb) x 100 Protocol 2 (acc. to DCCT/NGSP): HbA1c (%) = (HbA1c/Hb) x 87.6 + 2.27 HbA1c results obtained from the Cobas C111 analyser were compared with those obtained using the Bio-Rad Varaint II HbA1c testing system. Analytical performance was assessed using Analyse-It Passing Bablok comparison and Bland Altman difference plot. Imprecision was estimated using two samples run daily in triplicate over a period of five days. A Passing-Bablok comparison equation C111 = 0.19+0.96 Variant II was determined. The level of bias at the critical point of HbA1c of 8.0% was estimated to be -0.11 and -0.09 across the range of analysis.The total imprecision was determined to be 2.6% with an intra assay CV of 1.6% Intra assay precision profileof the Cobas C111(IFCC) Precision profile Low pool mM/M Medium pool mM/M High Pool mM/M   34.75 82.28 119.80 34.53 81.66 122.22 34.71 81.33 120.87 34.94 81.03 122.32 35.57 81.36 121.11 35.42 81.99 119.36 35.48 83.02 119.58 35.38 83.08 119.73 Mean 35.10 81.97 120.62 SD 0.41 0.77 1.19 CV 1.2% 0.9% 1.0% CONCLUSION The HbA1C determination on the Cobas C111 is based on the turbidimetric inhibition assay for haemolysed whole blood. The analytical performance of the C111 is good and satisfies essential performance criteria. The analyser is relatively small with a comprehensive clinical chemistry test menu. A hospital scientist and a technical officer unfamiliar with Roche analysers were easily trained to operate the analyser. In our opinion the C111 would be best suited to low throughput laboratories, and would provide good analytical performance. Inter/Intra-assay variation of Normal pool HbA1c results measured on the Roche Cobas C111(DCCT/NGSP) Run Date Replicate 1 Replicate 2 Replicate 3 1 27/09/2010 6.000 5.800 2 29/09/2010 5.700 5.600 3 30/09/2010 4 1/01/2010 5 6/10/2010 5.900 References Cobas C111 HbA1c Kit insert.   Within run Imprecision Total imprecision % HbA1c 0.09 0.15 CV 1.60% 2.60%