Experimental hall design in Japanese site

Slides:



Advertisements
Similar presentations
Kitakami IR Access Discussions T. Markiewicz/SLAC 13 May 2014 SiD Meeting / AWLC Fermilab.
Advertisements

SiD Surface assembly Marco Oriunno (SLAC) MDI-CFS Meeting Sep. 4-6, 2014, Ichinoseki (Japan)
Assembly Hall in Hybrid-A’ and ILD 2014/9/6 Yasuhiro Sugimoto 1.
1 IR Hall for GLD Oct Y. Sugimoto KEK. 2 Underground hall HybridPure CMS IR hall area (WxL)25x55 Beam height8.6 Crane max hook height20.5 Largest.
SiD assembly Marco Oriunno (SLAC), May. 14, 2014 ALCW 2014, Fermilab Infrastructures & Timeline for Hybrid Access.
Global Design Effort Detector concept # Plenary introductory talk IRENG07 Name September 17, 2007.
DH in Hybrid-A and ILD 2014/9/5 Yasuhiro Sugimoto 1.
Experimental hall in Japanese mountain site Y. Sugimoto ILD MDI/Integration 1.
Conventional Facilities and Siting Global Design Effort Safety Requirements for IR Conventional Facilities and Siting Group Safety Requirements for IR.
Cryogenic cavern in Asian site Conceptual design of the cryogenic system Layout of the cryogenic plant for site A & B New layout of the cryogenic system.
1 FD Support and Pacman for GLDc 27 Aug Yasuhiro Sugimoto KEK.
Global Design Effort - CFS for Asian Single Tunnel Configuration Design Progress Masanobu Miyahara KEK.
1 GLD Surface Assembly Y. Sugimoto KEK
LCC Linear Collider Collaboratio ILC - CFS 12 November 2013 LCWS13 Tokyo University 1 Site-specific CF design from TDR LCWS13, 12 November 2013 Atsushi.
1 Alternative assembly option of ILD Y.Sugimoto 2010/10/18 ILD Integration
Experimental hall in Japanese mountain site Y. Sugimoto 1.
Conceptual Design Study - Cryogenic Requirements How to decide the layout of ILC cryogenic system Conceptual design of cryogenic system Layout of cryogenic.
Global Design Effort - CFS SiD Collaboration Meeting - SLAC 1 VERTICAL ACCESS ILC IR LAYOUT for SiD and ILD CONVENTIONAL FACILITIES AND SITING.
PD5: Detector Integration / Machine Detector Interface T. Markiewicz/SLAC 15 May 2014 SiD Meeting / AWLC Fermilab Summary.
LINEAR COLLIDER COLLABORATION Designing the world’s next great particle accelerator Detector Hall Configuration Overview New baseline (Hybrid A’) proposed.
KEK Hiroshi Yamaoka Task list for Magnet/Iron yoke Solenoid magnet Iron yoke Experimental hall and other facilities May 11, ’05.
1 GLD and GLDc Sep. 12, 2007 Y. Sugimoto KEK. 2 Compact GLD Option Motivation –GLD and LDC will write a common LoI –The detector design should have common.
ILD requirement for assembly space and time 2015/11/3 Yasuhiro 1.
Strategy of detector solenoid construction Yasuhiro Sugimoto KEK 1.
Experimental Areas Studies Lessons learnt at CMS M Gastal & CMS Technical Coordination (A Ball, W Zeuner)
ILC D RAFT P ROJECT S CHEDULE K LYCLUSTER 500GeV K Foraz & M Gastal ILC Mechanical & Electrical Review and CFS Baseline Technical Review Many thanks to.
Access Yard Assembly Marco Oriunno (SLAC), November 13, 2013 LCWS13, TOKYO.
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
GLD experimental hall and detector assembly Y.Sugimoto KEK 27 Sep
Iouri Ivaniouchenkov RAL Specifying the needs for MICE July 8, RAL MICE Collaboration Meeting 1.
March 22, –  Design Concept & Hall Layout  Access Tunnel  Top heading Tunnel  Displacement of detector hall by push-pull operation.
Assembly scenario of ILD Si trackers 2015/4/21 Yasuhiro 1.
FCC-hh MDI 5 th Meeting Friday 13 th March 2015 Civil Engineering Layouts for Experimental Caverns – First Draft Charlie Cook (GS), John Osborne (GS)
ILD and SiD in Japanese site (from discussions in SiD/ILD E/D Interface Working Meeting) Yasuhiro Sugimoto, Marco Oriunno 2011/12/15 SiD
1 May 22, Y.Sugimoto Update of detector hall in mountain region.
SiD MDI Issues Tom Markiewicz/SLAC Beijing ACFA/GDE Meeting 05 February 2007.
ICARUS Collaboration Meeting Dec A. Scaramelli.
Experimental hall in Japanese mountain site 2011/11/30 Yasuhiro CFS Webex meeting 1.
8/29/07K. C. Wu - Brookhaven National Lab1 Major Components in ILC IR Hall Interchangeable Detectors.
1 Cryogenic System of Interaction Region (SiD, ILD, QD0, QF1, Crab Cavity) in the Japanese Mountain Site WebEx meeting : June 19 th, 2012 IPNS/Cryogenic.
An idea of ILD general assembly plan 2015/10/8 Yasuhiro Integration Meeting 1.
Kitakami Side AHCAL Assembly or anywhere in any detector.
M.Oriunno, SLAC 1 SiD installation with horizontal access shafts Marco Oriunno, SLAC SiD/ILD Engineering Meeting SLAC, December 2011.
1 Update of detector hall in mountain regions Y.Sugimoto in Granada.
Civil Design for Tunnel Case Studies
Experimental Hall in Mountain Regions
SiD Collaboration Meeting SLAC, December 2011
2016/9/30 Yasuhiro Infra/CFS mini-ws
Detector Hall Design and Cost Information CONVENTIONAL FACILITIES
CLIC Handling Engineering Update
CLIC Civil Engineering Update
Updated Design of Detector Hall
Introduction and Meeting Objectives
Detector Utility/Service Cavern
Yasuhiro Sugimoto 2012/2/1 ILD integration meeting
Marco Oriunno (SLAC), March 12, 2014 MDI WG
BDS Cryogenic System RDR Status and EDR Plans
Current Site Status at IP Preliminary survey of campus
Part II: Integrated Design of Infrastructures
Update of experimental hall in Japanese mountain site
Detector Service Cavern for ILC
Hybrid Access Optional Study
Detector hall in mountain regions
Status of Cryogenics Facilities Design
Sub-Detector Assembly Area Summary of discussion at ALCW2015
Cryogenic cavern in Asian site
Detector hall in mountain regions
Extract from today’s talk given to DCB
8-10 April 2014 CFS-ADI Joint Meeting
Overview of Day One – 29 Feb 2016
Presentation transcript:

Experimental hall design in Japanese site Yasuhiro Sugimoto 2011/12/13 CFS meeting @SLAC

Outline Experimental hall ILD detector assembly Access tunnel Main cavern Storage cavern Compressor cavern ILD detector assembly Access tunnel Safety issues Parking area Future plan

Experimental hall Recent update after Nov.30 Storage caverns at both ends Compressor cavern moved by 15m Small tunnels connecting the storage caverns and the main access tunnel Small tunnel connecting ILD storage cavern and compressor cavern

Storage cavern (small tunnels not shown) Helium compressor / cryogenics Detector services Main access tunnel Loading area

Surface Storage caverns are not shown Damping Ring

Main cavern I-shape, 25m(W)x110m(L)x37m(H) Access tunnels from a side wall Construction adit at the top of the cavern After construction, it will be used for a duct tunnel and a path of smokes/He gas in emergency Alcoves (7.5m depth) at the garage positions Storage caverns (alcoves) at both ends Two sets of ~200 ton crane with smaller sub-crane 1 m thick side walls supporting crane rails Floor level is 12.6 m (=9+2.2+1.4) below the beam line

Main cavern Cross section view along the beam line

Main cavern Side wall – garage side (view from inside)

Main cavern Side wall – access tunnel side

Storage cavern Purpose Size:15m(W)x20m(D)x15m(H) Storage of detector pieces before installation Preparation/storage of tools for detector assembly/installation Meeting rooms and rest room can be build in this cavern Size:15m(W)x20m(D)x15m(H) Connected to the main access tunnel by a small tunnel ILD storage cavern is connected to the compressor cavern by a small tunnel

Storage cavern

Based on cryogenic system for JPARC Compressor cavern 15m(W)x50m(L)x7m(H) Helium compressor and liquefier for ILD/SiD solenoid QD0/QF1 Crab cavity Requirements: 400kW electric power 300L/min cooling water 10000m3/h air ventilation Air compressor for air-pads ? Common or independent ? Liquefier Compressor Based on cryogenic system for JPARC 1.2kW

Cryogenic system Helium gas storage tank on surface Compressor and liquefier in the compressor cavern 4K saturated liquid helium tank in the main cavern or in the (ILD) storage cavern 2K sub-coolers in (near) the beam tunnels by Y. Makita

ILD Detector assembly Solenoid Return yoke Wound, assembled, and tested on surface Carried into the cavern as a whole Return yoke Pre-assembled on surface as relatively small blocks ~200 tons Each ~200 ton block is carried into the cavern one by one and assembled into one barrel No gap in the barrel yoke  Less leakage field Large assembly hall on surface is necessary

ILD Detector assembly 1 2 Barrel assembly Endcap (+) assembly Solenoid installation QD0 support tube (-) assembly QD0 support tube (+) assembly Sub-detector installation 3 4 5 6

Access tunnel ILD SiD A trailer with lower deck height would reduce the tunnel size

Access tunnel Trailer truck for transportation 225t/5axles450t with 2 trailers Capability of ~7% slope Gear track (Abt system) is also suggested

Access tunnel Crossing with main access tunnel

Access tunnel Crossing with sub access tunnel

Access tunnel parameters There are several options for the ILC route and the location of the IP, and the optimization is not done yet Parameters listed below are just for some examples of the access tunnel to the experimental hall Site Option Length Slope Earth covering* Beam line elevation A 1 1770 m 6.3% ~300 m 110 m 2 980 m ~200 m B 1420 m 7% ~550 m -30 m 2** 1470 m ~400 m -21 m (*) Vertical distance between the cavern ceiling and the surface These values changes largely with the IP location (**) Main linac is inclined by 0.03%

Tunnel layout examples

Safety issues Ventilation Escape in emergency Smoke and Helium gas will go out through the construction adit connected at the top of the cavern, and will not flow into the access tunnel Small vertical shaft for GPS alignment may be used for ventilation Amount of Helium gas ~ 20000m3 (CMS: 2x250m3x20bar =10000m3 at 1bar, x2 for SiD+ILD) =25mx100mx8m  No problem Escape in emergency Enough number of electric cars equipped with oxygen masks will effectively take people to the surface

Electric cars Mitsubishi TOYOTA Nissan

Parking area Main access tunnel and compressor cavern are large enough for parking space of >50 cars 2.5mx6m 3mx5m

Things to do More considerations and studies on Safety issues (evacuation of people in emergency) Vehicles for transportation of heavy elements (gear track?) Parameters to be specified Crane capacity Temperature and dew point in the cavern Requirements for electric power, cooling water, and air conditioning Estimations to be made Ventilation speed of smoke/He Stress and deformation of the cavern with complete design Cost and construction period