Development of LAMBDA: Large Area Medipix-Based Detector Array

Slides:



Advertisements
Similar presentations
STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
Advertisements

Optical image tube with Medipix readout
CCD-style imaging for the JCMT. SCUBA-2 technology  the ability to construct large format detector arrays  signal readouts that can be multiplexed To.
Module Production for The ATLAS Silicon Tracker (SCT) The SCT requirements: Hermetic lightweight tracker. 4 space-points detection up to pseudo rapidity.
3D PACKAGING SOLUTIONS FOR FUTURE PIXEL DETECTORS Timo Tick – CERN
Institute of Experimental and Applied Physics Czech Technical University in Prague 11th December 2007 Michal Platkevič RUIN Rapid Universal INterface for.
-1- Current Telescope Strengths High resolution (~2.5um) Adaptability Ease of use – Currently borrowed by SPS collimator group Weaknesses Small number.
SVX4 chip 4 SVX4 chips hybrid 4 chips hybridSilicon sensors Front side Back side Hybrid data with calibration charge injection for some channels IEEE Nuclear.
Bump Bonding and Thinning of Hybrid Pixel Detectors Kiyoshi Tanida (RIKEN) Johann M. Heuser (RIKEN) PHENIX upgrade workshop, Aug 2002 Contents Bump bonding.
Fabian Hügging – University of Bonn – February WP3: Post processing and 3D Interconnection M. Barbero, L. Gonella, F. Hügging, H. Krüger and.
Edgeless Medipix sensors for medical X-ray imaging applications Marten Bosma BND School in Rathen, 2009-Sep-14.
AIDA annual meeting,Vienna, 26th March 2014Václav Vrba, Institute of Physics, Prague 1  design of sensors for production submission  design of the readout.
Leo Greiner IPHC testing Sensor and infrastructure testing at LBL. Capabilities and Plan.
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
ALICE Rad.Tolerant Electronics, 30 Aug 2004Børge Svane Nielsen, NBI1 FMD – Forward Multiplicity Detector ALICE Meeting on Rad. Tolerant Electronics CERN,
, T. Tischler, CBM Collaboration Meeting, GSI Status MVD demonstrator: mechanics & integration T.Tischler, S. Amar-Youcef, M. Deveaux, D. Doering,
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
The AGIPD Detector for the European XFEL Julian Becker (DESY), Roberto Dinapoli (PSI), Peter Goettlicher (DESY), Heinz Graafsma (DESY), Dominic Greiffenberg.
Development of a high-speed single photon pixellated detector for visible wavelengths Introduction A photon incident on the photocathode produces a photoelectron.
1 Activities in Wuhan TopMetal sensor & ALICE ITS upgade Xiangming Sun CCNU ALICE ITS Upgrade and O2 Asian Workshop 2014.
2 Silicon pixel part Done and to be written Written! Under way To be done Introduction 1.Hybrid Pixel Assembly Concept 2.Silicon sensor 1.First thinned.
Thin Silicon R&D for LC applications D. Bortoletto Purdue University Status report Hybrid Pixel Detectors for LC.
HIGH QUANTUM EFFICIENCY NEUTRON DETECTOR WITH A SPATIAL RESOLUTION IN THE MICROMETER RANGE GÖRAN THUNGSTRÖM.
Towards a 7-module Micromegas Large TPC prototype 1 D. Attié, P. Baron, D. Calvet, P. Colas, C. Coquelet, E. Delagnes, M. Dixit, A. Le Coguie, R. Joannes,
Vessel dimensions GTK assembly carrier Electrical connections Cooling pipes integration Vessel alignment with the beam Next steps Conclusion 3/10/20102.
Detector DESY for the European XFEL. Heinz Graafsma; Head of FS-DS; DESY-Hamburg AIDA-Workshop; Hamburg; March 2012.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
Vessel dimensions GTK assembly carrier Electrical connections Cooling pipes integration Vessel alignment with the beam Next steps Conclusion 3/23/20102electro-mechanical.
NI Big Physics Summit CERN
ICT 1 SINTEF Edge-On Sensor with Active Edge Fabricated by 3D-Technology T. E. Hansen 1), N. Ahmed 1), A. Ferber 2) 1) SINTEF MiNaLab 2) SINTEF Optical.
RD program on hybrids & Interconnects Background & motivation At sLHC the luminosity will increase by a factor 10 The physics requirement on the tracker.
Status report Pillar-1: Technology. The “Helmholtz-Cube” Vertically Integrated Detector Technology Replace standard sensor with: 3D and edgeless sensors,
Latest news on 3D detectors IRST CNM IceMos. CNM 2 wafers fabricated Double side processing with holes not all the way through, (aka Irst) n-type bulk.
K.Wyllie, CERNIWORID 2004 Readout of the LHCb pixel hybrid photon detectors Ken Wyllie on behalf of the LHCb collaboration and industrial partners The.
The medipix3 TSV project
Medipix3 chip, downscaled feature sizes, noise and timing resolution of the front-end Rafael Ballabriga 17 June 2010.
Giulio Pellegrini Actividades 3D G. Pellegrini, C. Fleta, D. Quirion, JP Balbuena, D. Bassignana.
Hybrid Boards for PXD6 5th International Workshop on DEPFET Detectors and Applications Sept Oct Christian Koffmane 1,2 1 Max-Planck-Institut.
Low Mass, Radiation Hard Vertex Detectors R. Lipton, Fermilab Future experiments will require pixelated vertex detectors with radiation hardness superior.
SVD Status Markus Friedl (HEPHY Vienna) SVD-PXD Göttingen, 25 September 2012.
SiW Electromagnetic Calorimeter - The EUDET Module Calorimeter R&D for the within the CALICE collaboration SiW Electromagnetic Calorimeter - The EUDET.
Atlas SemiConductor Tracker final integration and commissioning Andrée Robichaud-Véronneau Université de Genève on behalf of the Atlas SCT collaboration.
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
CMS Phase 2 Tracker R&D R. Lipton 2/27/2014
Sensors Pixel dimension 300 x 300 μm2 Standard p-in-n sensors
Progress with GaAs Pixel Detectors
Si Sensors for Additional Tracker
Study of Indium bumps for the ATLAS pixel detector
Ivan Peric, Christian Kreidl, Peter Fischer University of Heidelberg
New Mask and vendor for 3D detectors
H. Toyokawa1, C. Saji1, M. Kawase1, S. Wu1, Y. Furukawa1, K
Thinning and Plans for SuperBelle
FCAL R&D towards a prototype of very compact calorimeter
Tango Integration of Modern 2D Detectors
Status of Medipix Quads in Institute of Physics Prague
Jan Soldat, Heidelberg University for the DSSC ASIC design groups
Hybrid Pixel R&D and Interconnect Technologies
M. C. Veale1, S. J. Bell1,2, D. D. Duarte1,2, M. J. French1, M
Development of high-Z sensors for pixel array detectors
Large Area Endplate Prototype for the LC TPC
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
TIMEPIX TESTBEAM TELESCOPE FOR AIDA
prototype PCB for on detector chip integration
The AGIPD Detector for the European XFEL
FEE Electronics progress
Silicon pixel detectors and electronics for hybrid photon detectors
A new family of pixel detectors for high frame rate X-ray applications Roberto Dinapoli†, Anna Bergamaschi, Beat Henrich, Roland Horisberger, Ian Johnson,
Enhanced Lateral Drift (ELAD) sensors
New detectors are needed! Prototype Characterization
Perugia SuperB Workshop June 16-19, 2009
Presentation transcript:

Development of LAMBDA: Large Area Medipix-Based Detector Array David Pennicard, Sabine Sengelmann, Sergej Smoljanin, Julian Becker, Helmut Hirsemann, Heinz Graafsma Photon Science Detector Group, DESY X-ray detector system, based on the Medipix3 readout chip

Large Area Medipix-Based Detector Array Motivation Detector design and current status of system Further developments Germanium pixel detector development Designed to be compatible with a range of high-Z sensor materials such as CdTe, GaAs, but ties in closely..

PETRA-III synchrotron New 3rd generation light source (2009) Aims of detector development Improve on successes with silicon hybrid pixel detectors Replace silicon with high-Z material for high energy beamlines High-energy beamlines 1021 ph/(s mm2 mrad2 0.1% BW). Germanium pixel detector project Don’t discuss details!

Medipix3 readout chip 21 groups in collaboration Photon-counting chip Chip design at CERN Photon-counting chip 256 * 256 pixels, 55µm Continuous read-write (2000 fps with 12 bit counter depth) Charge summing using interpixel communication Note – proportionally faster Nice to mention other groups in collaboration Medipix3 chip quite flexible, range of apps – our interest Avoid discussing details – simulation interesting

Large Area Medipix-Based Detector Array Motivation Detector design and current status of system Further developments Germanium pixel detector development Introduction Detector design

LAMBDA detector head 6-by-2-chip layout Tilable layout Set by typical silicon and high-Z wafer sizes (6”, 3”) Tilable layout Electronics behind sensor High-speed readout All 8 readout pairs per chip used Cooling Compatible with low-temperature operation (-60°C for germanium) 1 large Si sensor 84 mm * 28 mm 2 “hexa” high-Z sensors Each 42 mm * 28 mm or Voltage reg. board First use single modules for experiments like XPCS, acts as a platform for 6*2 Medipix 3 chips Module ceramic Heat spreader

System design Sensor assembly on module ceramic Voltage regulator PCB Cooling block Readout board controls module sensor FPGA Heat spreader PCB Readout chip Connections to PC Cooling block Connector through backplane Initial readout board – USB2 readout, allows chip testing and firmware development Note – idea is to have a detector head without “intelligent” components (except Medipix3, obviously) and then readout Final board – Board based on XFEL (AGIPD) developments with 10 GBE readout 7

Detector assembly and module ceramic PCB Side view Sensor Readout chip Readout chip Heat spreader Module ceramic Cooling High-density connector Heat spreader to improve temperature uniformity Low-Temp Co-fired Ceramic (LTCC) board - KOA, Japan Matching of CTE to sensor materials (6 ppm / K) Heat coupling through board under each chip with thermal vias 500-pin Samtec high density right-angle connector Still providing enough layers for signal Note – direct cooling to each chip required for temperature uniformity

Current readout board Virtex-5 FPGA USB2 readout Same series as FPGA for high-speed readout board USB2 readout PC control with C++ (functions called by simple GUI)

Current system Si Medipix3 2*2-chip assembly (300μm thick) Flat connector used, rather than right-angle Thanks to Medipix3 collaboration for quad

Detector test Detector is working Standard functions implemented Threshold equalisation running (but needs improvement) Test mask image taken with Mo X-ray tube

Large Area Medipix-Based Detector Array Motivation Detector design and current status of system Further developments Germanium pixel detector development Introduction Detector design

Large-area silicon modules 6” wafers with large Medipix3-layout sensors ordered from Canberra Masks in production Working on assembly process and single module mechanics

High-speed readout system High-density connector Will modify board and firmware from XFEL Collaborating with TUM on firmware See Franz M. Epple’s poster Virtex-5 FPGA with PowerPC core RAM for data re-ordering and burst mode 4 * 10 Gbit Ethernet to allow maximum readout rate Maximum data rate from module is ~ 25 Gbit/s! FPGA DDR2 RAM mezzanine TUM – want to use with phase contrast imaging 10 GBE links

Large Area Medipix-Based Detector Array Motivation Detector design and current status of system Further developments Germanium pixel detector development Introduction Detector design

Germanium pixel development Canberra (Lingolsheim): M Lampert, M Zuvic, J Beau Fraunhofer IZM (Berlin): T Fritzsch, R Jordan, H Oppermann, O Ehrmann High-purity, high uniformity 90 mm Ge wafers available Cooled operation needed to reduce leakage current Per pixel current must be within ROC limits (order of nA per pixel) Est. -60°C operation with Medipix3 (55µm) Measured transport and depletion fine at this temperature Thermal stresses are biggest problem Fine pixellation and bump-bonding must be developed Note – developing germanium pixel detectors – Detectors being produced by Canberra Lingolsheim Also collaborating with IZM to develop bump bonding processes

Bump bonding and sensor processing Ge ~3.5μm max displacement during cooling Indium bump bonding Indium remains ductile at low temperatures Already used for IR hybrids at −196 °C Ge diodes used for processing tests Passivation and processing optimised to avoid sensor damage Bumps will be electroplated on sensor and ROC Bonding will use thermocompression at 80°C Si Should add diagram perhaps? Yes – GaAs quantum well infrared detectors with 1024 pixels of 20um pitch (about 20mm per chip). At LN2 temp, expect about ½ pixel shift at edges.

Pixel detector production at Canberra Detector structure: Thinned germanium wafer (700μm) Boron implanted on back contact New pixel architecture Test wafer produced (55μm pixels) Medipix3 90 mm mask produced 16 singles per wafer Optical Ge dummies in production Optimization of flip chip at IZM 2 high-purity wafers will be produced Expect sensors later this year 18 18

Summary Goal is to provide improved hybrid pixel detectors for PETRA-III Prototype Medipix3 module is complete Continuing to produce full Si sensors and high-speed readout Developing pixellated Ge sensors for high-energy beamlines

Thanks for listening