Maria’s Restaurant Chapter 4 Section 15

Slides:



Advertisements
Similar presentations
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Advertisements

Innovative Solutions to Improve Comfort & Efficiency NEX and PLAY.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Simple installation. VAV SYSTEM FEATURES ( One Of Many Types ) Electric or Pneumatic or Digital Controls “In Duct” &/or “At Diffuser” Locations Pressure,
Nonmetallic ducts (Additional information) –Fiberglass (also see section 18.5) Made of glass wool insulating material in which the stranded fiber wool.
Arthur Miller, CMS, RCT HVACR Training Consultant
Local Exhaust Hoods. 2 Introduction:  Designed to capture and remove harmful emissions from various processes prior to their escape into the workplace.
Airflow Properties & Measurement
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
Welcome to S&P USA & the 2012 International Residential and Mechanical Code for Ventilation.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Ventilation 1 - Program Basic Math & Problem Solving
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Basics Air Flow Basics -Air is invisible -Everyone assumes adequate airflow -Frequently airflow is 30%-50% low -Cooling – 400 CFM per ton -Heating.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Chapter 11: Space Air Diffusion Conditioned air is normally supplied to air outlets at velocities much higher than would be acceptable in the occupied.
Drafts and Duct System Sizing
NAFA Guide To Air Filtration Chapter 2 Principles of Air Flow, Air Pressure And Air Filtration presented by the National Air Filtration Association Fourth.
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Objectives Finish with Duct Design Review the design procedure and explain the theoretical background Diffuser Selection Answer question related to the.
Day 3 Part 3 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Hands-on Ventilation Training Black Lake 2013 Graham Parr Industrial Hygienist Joseph Ostach Industrial Hygiene Technician Graham Parr Industrial Hygienist.
Objectives - Air Distribution Systems -Diffuser selection -Duct design Reading Assignment: Chapter 18.
Objectives Air Distribution Systems -Diffuser selection -Duct design.
Duct Design Basics Lesson 4 Manual D Primer. Available Static Pressure 4.4.
Duct Design Basics Lesson 3 Calculations. Fitting losses, System Effect 3.4.
Copyright © Cengage Learning. All rights reserved. 1.4 Solving Quadratic Equations.
Lesson 1 Friction Chart Primer 1.3 Friction Chart.
Objectives Finish heat exchangers Air Distribution Systems
Duct Design Basics Lesson 4 Manual D Primer. Duct Sizing 4.3.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Maria’s Restaurant Chapter 2 Section 6
HVAC DUCT CONSTRCTION EXAMPLES
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Lesson 21 Appendix C Duct Design
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 1 Section 4
Airflow Quantity and Velocity
NAFA Guide To Air Filtration
Maria’s Restaurant Chapter 3 Section 13
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 5
Basics of Seed Conditioning
Maria’s Restaurant Chapter 1 Section 2
1.5 Applications and Modeling with Quadratic Equations
Lesson 23 Appendix C Exhaust Calculation
Maria’s Restaurant Chapter 2 Section 8
Technician’s Guide & Workbook for Duct Diagnostics and Repair
Maria’s Restaurant Chapter 3 Section 12
Maria’s Restaurant Chapter 4 Section 14
High Performance HVAC Installation
Objectives Finish with Duct Design Diffuser Selection
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Adding Zones to Existing Systems
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Mandatory Design Requirements
Excess Air Management Overview
Copyright © 2017, 2013, 2009 Pearson Education, Inc.
Mathematics of Air Filtration
Maria’s Restaurant Chapter 3 Section 12
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Lesson 22 Appendix C Zone 2 Duct Design
Maria’s Restaurant Chapter 2 Section 8
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 2
Maximizing the Use of Ductless Mini-Splits in Existing Homes
Presentation transcript:

Maria’s Restaurant Chapter 4 Section 15

Deflection and Throw

Deflection and Throw

Deflection Question What is the deflection angle for the diffuser shown? 22O

Throw Question What is the throw width and velocity at 25 feet? 50 feet per minute and approximately 15 feet wide (total width 7.5 per side).  

Maria’s Restaurant Diffuser Throw Zone 1 (one grid square = one ft2) Zone 2 G Supply Diffuser 550 CFM H F H A 6 Supply Diffusers 400 CFM Each B 25 ft. Zone 1 F D Zone 1 B EX. Hood E G E C A C D 5 Supply Diffusers 530 CFM Each 66 ft. Zone 1 Constant Volume 2,400 CFM Return: 1,711 CFM Zone 2 Constant Volume 3,200 CFM Stage 1 Return: 1,300 CFM Stage 2 Return: 3,100 CFM

Maria’s Restaurant Diffuser Throw Zone 2 (one grid square = one ft2) Zone 2 G Supply Diffuser 550 CFM H F H A 6 Supply Diffusers 400 CFM Each B 25 ft. Zone 1 F D Zone 1 B EX. Hood E G E C A C D 5 Supply Diffusers 530 CFM Each 66 ft. Zone 1 Constant Volume 2,400 CFM Return: 1,711 CFM Zone 2 Constant Volume 3,200 CFM Stage 1 Return: 1,300 CFM Stage 2 Return: 3,100 CFM

Return Grille

Filter Design The filtered airflow for Zones 1 & 2 are maximized in the economizer mode, at 2,400 CFM and 3,200 CFM respectively. Based on information found in our selected filters capacity and dimension tables: For Zones 1 & 2, the designer allowed a 0.1 IWC of pressure drop for the filters.

Filter Considerations Zone 1: 2,400 CFM ÷ 200 FPM = 12 ft2 Zone 2: 3,200 CFM ÷ 200 FPM = 16 ft2

Filter Size The more common approach would be to penalize the overall operating efficiency by increasing the blower size and fan speed to overcome the filter resistance. Looking again at Figure 28, a face velocity of 625 FPM would double the pressure drop for the entire duct system to 1.2”. In this case, the filter surface areas would be decreased to: Zone 1: 2,400 CFM ÷ 625 FPM = 3.84 ft2 Zone 2: 3,200 CFM ÷ 625 FPM = 5.12 ft2

Filter Considerations 1 4,200 ÷ 344 = 12.21 Sq. Ft. What size filter would be needed if the CFM value was 4,200 and the design IWC was 0.20? About 344 fpm

Filter Considerations 1 3,200 ÷ 344 = 9.3 Sq. Ft. What size filter would be needed if the CFM value was 3,200 and the design IWC was 0.20? About 344 fpm

Return Filter Question 2 Based on the XYZ filter chart used in the previous two charts, what will the pressure drop and face velocity be if a 27 × 24 filter is used for Maria’s restaurant Zone 1?

Return Filter Question 2 Based on the XYZ filter chart used in the previous two charts, what will the pressure drop and face velocity be if a 27 × 24 filter is used for Maria’s restaurant Zone 1’s 2,400 CFM? (27 × 24) ÷ 144 = Square feet of filter area = 4.5 2,400 CFM ÷ 4.5 ft2 = 533 feet per minute

Resistance in IWC Zone 1 533 feet per minute About About 0.48 IWC 533 fpm

Return Filter Question 2 Based on the XYZ filter chart used in the previous two charts, what will the pressure drop and face velocity be if a 27 × 24 filter is used for Maria’s restaurant Zone 2’s 3,200 CFM? (27 × 24) ÷ 144 = Square feet of filter area = 4.5 3,200 CFM ÷ 4.5 ft2 = 711 feet per minute

Resistance in IWC Zone 1 711 feet per minute Off of the chart …. Never go beyond the chart

Field Notes Unfortunately, it is not unusual to find a supply register with a design throw and angle that will cause someone to feel like they are sitting in a draft. Remember, simply throttling them down is not a solution. The author once found an office where 4 out of 5 diffusers were shut down causing the system to force the air through the last diffuser. The lady sitting in the strong breeze under that remaining noisy diffuser said she was the one who was always wanting it cooler so she didn’t feel she could complain. When all of the throw angles and CFM were properly set everyone was comfortable and the system had the correct airflow. Finally, it is way too common to find a filter that is too small for the HVAC system. Installers rarely check the filter area pressure drop design requirement and will install a return grille based on the duct size. Thus, the design external static pressure for the system will be high with an extremely high (negative value) value for the return duct measurement. You have probably seen in the field a properly designed system where the filter box area is much larger than the return duct.