Surface analysis for CERN: a wish list

Slides:



Advertisements
Similar presentations
Secondary Ion Mass Spectrometry
Advertisements

X-ray Photoelectron Spectroscopy
Lecture 6 ATOMIC SPECTROSCOPY
Spectroscopy Photoelectron spectroscopy X-ray absorption spectroscopy
Ion Beam Analysis techniques:
AMCF Materials Characterization School 2012 X-Ray Photoelectron Spectroscopy Tim Morgan.
AA and Atomic Fluorescence Spectroscopy Chapter 9
Lecture 18. Chemical: XPS.
Emre Ertuğrul Emin Şahin Seçkin Gökçe KMU 396 Material Science and Technology.
XPS and SIMS MSN 506 Notes.
X-Ray Photoelectron Spectroscopy (XPS)
X-Ray Photoelectron Spectroscopy (XPS)
X-Ray Photoelectron Spectroscopy of Interfaces
Surface Characterization by Spectroscopy and Microscopy
X-ray Photoelectron Spectroscopy —— Application in Phase-switching Device Study Xinyuan Wang A
SPSU Progress on coatings and grooves M.Taborelli -Progress on C based coatings -Progress on rough coatings -Progress on SEY instrument -Grooves.
Lecture 3 INFRARED SPECTROMETRY
PHI 710 Scanning Auger Nanoprobe
An Introduction to SIMS and the MiniSIMS ToF © Millbrook Instruments Limited Blackburn, UK
Development of a TOF Version of the Desktop MiniSIMS Design & Applications A.J. Eccles, B. Cliff, C. Jones, N. Long, P. Vohralik Millbrook Instruments.
Surface Characterization Techniques Topics: –Contact Angle Analysis –Light Microscopy –X-ray Photoelectron Spectroscopy (XPS) –Fourier-Transform Infrared.
Seminar Author: Bojan Hiti Mentor: doc. dr. Matjaž Kavčič Determination of trace impurities on Si wafers with x-ray fluorescence.
Secondary Ion Mass Spectrometry (SIMS)
Nitride Materials and Devices Project
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
An Introduction to SIMS and the MiniSIMS alpha
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Metal photocathodes for NCRF electron guns Sonal Mistry Loughborough University Supervisor: Michael Cropper (Loughborough University) Industrial Supervisor:
X-RAY PHOTOELECTRON SPECTROSCOPY (XPS)
Spectroscopy. Spectroscopy – Getting Ready  What happens when an electron absorbs energy?  What kind of energy can cause this to happen?  Why do different.
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
Preparation of Clean III-V Semiconductor Surfaces for NEA Photocathodes Yun Sun 1, 2, Zhi Liu 3, Francisco Machuca 3, Piero Pianetta 1 and William E. Spicer.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Quantification Techniques Under Dynamic SIMS 1 Secondary Ion Mass Spectrometer Start-Up Project Overview Secondary Ion Mass Spectrometry Overview MiniSIMS:
Sputter deposition.
Desorption mechanism of hydrogen isotope from metal oxides Contents 1.Background 2.Experimental system and Mechanism 3.Results and discussion 4.Conclusions.
Department of Synchrotron Radiation Research Lund University
Scanning capacitance microscopy
Passivation of HPGe Detectors at LNL-INFN Speaker: Gianluigi Maggioni Materials & Detectors Laboratory (LNL-INFN) Scientific Manager: Prof. Gianantonio.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
Updates of Iowa State University S. Dumpala, S. Broderick and K. Rajan Sep – 18, 2013.
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
Antihydrogen Workshop, June , CERN S.N.Gninenko Production of cold positronium S.N. Gninenko INR, Moscow.
Lecture 5: Secondary ion mass spectroscopy (SIMS) Assoc. Prof. Dr. Zainovia Lockman, PPKBSM, USM EBB 245. Materials Characterisation.
Mg Films Grown by Pulsed Laser Deposition as Photocathodes: QE and surface adsorbates L. Cultrera INFN – National Laboratories of Frascati.
Auger Electron Spectroscopy. Outline 1.Introduction 2.Principle of AES 3.Instrumentation 3.1 UHV environment 3.2 Electron gun 3.3 Electron energy analyzer.
X-ray photoelectron spectroscopy (XPS)
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
UV/VIS SPECTROSCOPY.
Research stoichiometric of heterogeneity of lithium niobate crystals by IR spectroscopy Paranin V.D., Pantelei E.
Chem. 133 – 3/14 Lecture.
Coatings for neutron conversion for n_TOF
Auger Electron Spectroscopy (AES)
Study of vacuum stability at cryogenic temperature
Syedah Sadaf Zehra DCU and UNIPD Supervisors
Lecture 4 Fundamentals of Multiscale Fabrication
What is XPS? XPS (x-ray photoelectron spectroscopy) is also known as ESCA (electron spectroscopy for chemical analysis). XPS provides chemical information.
Spectrophotometer Dr . S. Jayakumar.
Secondary electron yield of cryogenic surfaces as a function of physisorbed gases Asena Kuzucan TE-VSC-SCC.
Progress report on coatings for SPSU
Study of vacuum stability at cryogenic temperature
Instrument Parameters in WDXRF
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Surface and Interface Characterization of Polymers
SILICON MICROMACHINING
BONDING The construction of any complicated mechanical device requires not only the machining of individual components but also the assembly of components.
Semiconductor Detectors
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Surface analysis techniques part I
Presentation transcript:

Surface analysis for CERN: a wish list M.Taborelli New XPS Repair SIMS Kelvin Probe UPS

Surface analysis lab Typical useful information for a surface: -identification of elements present on the surface and quantification (elemental surface concentrations) -identification of chemical groups/bonds present on the surface concentration profile in depth Other surface properties: work function, secondary electron yield, surface energy

Identification of elements (in the topmost 1 nm layer) I elements Identification of elements (in the topmost 1 nm layer) Presently at CERN lab (101): XPS (30 years old), lateral resolution 1-4 mm (XPS) AES (25 years old), lateral resolution 0.1-0.2 mm (AES) detection limit around 0.5-5% depending on element (except H) Typically 150 jobs/year or 700 measurements. The instruments (especially the frequently used XPS) need often maintenance due to their age Lateral resolution requirements for a new machine - For most of the applications (contamination detection, NEG activation control, coatings control ….) high spatial resolution would be helpful, but is not mandatory -The request for spatial resolution comes mainly from the experiments (contamination on chip contact pads and similar): few requests per year Existing commercial standard instruments: 0.003-0.1 mm lateral for XPS 20 nm lateral for AES Detection limits are similar as old instruments, but with more efficiency (faster acquisition, less sample irradiation)

Further requirements for a new XPS machine: I elements Further requirements for a new XPS machine: -base pressure of the instrument should be sufficiently low for example to enable clean activation of NEG (low 10-10 mbar range) -heatable manipulator should have low outgassing (residual pressure < 10-8 mbar at 250C) -flexibility to connect other (home made) devices -larger sample insertion port (DN63 instead of DN40) if we want also UPS (see later) we need an excellent shielding from magnetic fields and a suitable electron energy analyser (energy resolution) : vacuum chamber in mu- metal

XPS principle Energy analyser Source (CMA) X-rays UHV chamber I elements XPS principle Energy analyser (CMA) Source X-rays detector UHV chamber

Identification of chemical bonds II bonds/ groups Identification of chemical bonds Present situation at CERN labs (101+10): Non-monochromatized XPS through energy shift of the lines: works for many metal/oxides with the present instrument, more difficult for organic bonds in adsorbates (contamination), carbon….Impossible for silicone/silicates For soluble organic or silicone contamination: elution in hexane subsequent FTIR (absorption spectroscopy of a drop re-deposited on transparent substrate); can be done if the surface is sufficiently large to provide enough eluted material

Detection of silicones by FTIR Elution of contaminant from the “cleaned” part (tube, valve ,..) with a defined quantity of hexane per surface area Deposition of a drop of solution on a ZnS window (transparent to IR) Measurement of transmittance after evaporation of the hexane Wavenumber [cm-1] CH3 asymmetric deform. of Si-CH3 CH3 symmetric deform. of Si-CH3 Si-O-Si stretching Si-C stretching and CH3 rocking CH stretching of CH3 Transmittance [%] S.Ilie, C.Petitjean, C.Dias-Soares Sensitivity depends on the area used for the elution (various drops can be cumulated if necessary to increase concentration) Problem: Uncertainty on the effectiveness of elution

Non-monochromatized vs monochromatized X-ray source II bonds/ groups Non-monochromatized vs monochromatized X-ray source Non-monochromatized (present CERN source) Monochromatized , with in addition spatial resolution e-gun with scanning beam e- Quartz crystal monochromator anode hν e- X-rays anode thin Al foil to stop Bremsstrahlung sample sample Source gives a spectral line (ex.AlKa with its satellites Kb etc..) Source gives only one line (ex AlKa)

Advantages of a monochromatized source II bonds/ groups Advantages of a monochromatized source Monochromatized source Secondaries High resolution carbon 1s spectra from the same selected areas that show the presence of a fluorocarbon contamination in localized areas on the polymer surface. Interpretation and fitting of the various components is easier! It would be a step back in time to buy a non-mono. Source. Secondaries

of Physical Electronics On a-C coatings 278 280 282 284 286 288 290 292 294 296 298 1000 2000 3000 4000 5000 6000 7000 8000 CERN0102_1.SPE Binding Energy (eV) c/s Courtesy R.Shankar of Physical Electronics

CERN0102_1.SPE: CNe35 - Carbon coating PHI 2010 Mar 23 Al mono 98.9 W 100.0 µ 45.0° 11.75 eV 8.38 min C1s/Area1/1 (Shft) 278 280 282 284 286 288 290 292 294 296 298 1000 2000 3000 4000 5000 6000 7000 8000 CERN0102_1.SPE Binding Energy (eV) c/s Pos. Sep. %Area 284.79 0.00 61.12 286.33 1.54 21.82 288.36 3.57 9.87 290.34 5.55 7.19

One step further: SIMS (Secondary Ion Mass Spectroscopy) II bonds/ groups One step further: SIMS (Secondary Ion Mass Spectroscopy) Only meaningful after a preliminary XPS analysis -detects molecular fragments with higher surface sensitivity, lower detection limit, depending on element/group and matrix , but typically below 1 0/00 -absolute quantification is difficult, due to matrix effects (sensitivity for A in B is not the same as A in C) Present CERN system (not working at the moment): -Ar ion gun -in the XPS chamber -only dynamic, for high masses (>30-40) -in principle one can do profiles….but not quantitative

Typical performance of modern instruments II bonds/ groups Typical performance of modern instruments Modern TOF systems can distinguish between chemical groups which are very close in mass, with a resolution of m/Δm=10000 CERN system TOF-SIMS 0.2 amu/e ! For us a Static SIMS would be useful (changes of the surface influencing SEY) since it has even more surface sensitivity than XPS and it does not damage the surface

Depth profiling Present situation: III profiling Depth profiling Present situation: with XPS up to 30 nm depth and AES to 100 nm depth, with Ar ions used to detect inter-diffusion in layer on layer systems or to measure relative oxide thicknesses Note: The speed/depth is limited by the signal to noise (acquisition time) and the performance of the ion gun. In fact indirectly is limited by the lateral resolution of the technique: the sampling spot defines the maximum ion current density that the ion gun can achieve Commercially existing improvements: - Ion guns with different ions (as exotic as C60) and Zalar (azimuthal) sample rotation to avoid “cratering” effect of the beam

Work function measurements IV WF Work function measurements Present situation: Relative work function measurements can be done in principle with the XPS system by looking at the low kinetic energy tail. Not routine. Possible applications: useful to understand mechanisms of physisorbed layers on SEY (also cold SEY) and on spark test samples (influence on field emission) Improvements: Kelvin probe: cannot be installed in the old XPS (no free flanges) , but possibly in the SEY system . Home made or commercial. Or: Measure workfunction with UPS (ultraviolet photoemission spectroscopy) by taking the length of the energy spectrum. Needs a UV lamp and an electron analyser with sufficiently good energy resolution (available on most XPS analyzer as further option) UPS enables to measure valence band spectra: interesting for adsorbates (often molecular orbitals can be identified, provided that one species only is present), coatings with different electronic/electrical properties depending on deposition parameters (TiN, a-C…)

Secondary electron yield IV SEY Secondary electron yield Presently at CERN (101 and 30) System for measuring SEY from 50-2000eV (20-2000 eV) primary energy on conductors only at RT and down to 8K on conductors Improvements: -pulsed beam with shorter pulses to measure on insulators: hardware available, needs some testing, programming, etc… -8K down to 4.2K foreseen -measurements at lower primary energy (0-10eV) would be interesting, but are and experiment in itself No commercial systems with collector geometry, only electron guns are commercial

Surface energy …or something related to it Contact angle measurements : -presently only some temporary “bricolage” with microscope, CCD and syringe -commercial devices exist -applications would be mainly for control of surface processes (cleaning, CO2 jet cleaning, glow discharge cleaning…) to enhance wettability and adhesion of coatings NB: absolute measurement of surface energy is extremely complex and implies the knowledge of the interaction energy of the liquid with the surface (not only surface energy of the liquid). In general it is extrapolated from many measurements with different liquids (for polymers)

Conclusion Minimum requirements -XPS with monochromatic source, with an energy analyzer which is good enough for UPS and improved data handling -evaluate a repair of existing SIMS (Bdg 101) Further upgrade -add UV source for UPS -ion gun for depth profiling on th new XPS -Kelvin probe