Detector development for

Slides:



Advertisements
Similar presentations
Digital Detectors n Cassette based Image Storage Phosphor (CR) n Image Intensifier n Scanned Projection n Direct Digitizing (Full Field) –CCD Camera –Selenium.
Advertisements

Night Vision By Arthur Wolff Justin Fromm. Night Vision Uses Rifle Mounted Scopes Binoculars Cameras Telescopes Goggles.
PHEMOS UV Imager Summary. Status on Tasks COM DEV and U of C signed a contract in December Provided feedback on science requirements Started to look at.
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Digital Radiography.
SWD 2005, Taormina, Jun,19-26 An EUV Imaging Detector of Space Solar Telescope Qian Song, Binxun Ye, Zhaowang Zhao National Astronomical Observatories,
Science Payload and Advanced Concept Office (SCI-A) L. Duvet SDW2005, Taormina, Sicily 22/06/05 Active Pixel Sensor developments for future ESA space science.
Image Intensifier/CCD option for fiber readout S. Manly (Rochester), R. Ransome (Rutgers) Minerva collaboration meeting, FNAL, June 2003 Thanks to C.Walters,
CCD testing Enver Alagoz 12 April CCD testing goals CCD testing is to learn how to – do dark noise characterization – do gain measurements – determine.
CCD Detectors in High- Resolution Biology Jian Guan
Overview of Scientific Imaging using CCD Arrays Jaal Ghandhi Mechanical Engineering Univ. of Wisconsin-Madison.
DIGITAL FLUOROSCOPY.
ISUAL Sprite Imager Electronic Design Stewart Harris.
TIPS presentation 19 July 2007Charles Proffitt COS-STIS TeamPage 1 STIS FUV MAMA Dark Current Charles Proffitt COS-STIS Team.
WSO/UV World Space Observatory / Ultraviolet Project
Leo Greiner IPHC testing Sensor and infrastructure testing at LBL. Capabilities and Plan.
Liquid scintillator for an off-axis neutrino detector? (The Minnesota group) We are actively investigating a liquid scintillator option for the off-axis.
A Fiber Profile Monitor for Low Beam Intensities * G. Tassotto †, H.Nguyen, G. Sellberg, D. Schoo, Fermi National Accelerator Laboratory, Batavia, IL 60510,
WSO/UV-LSS Detector with large dimension MCP Baosheng Zhao* National Astronomical Observatories of CAS *
LOGO ภาควิชาอิเล็กทรอนิกส์ คณะวิศวกรรมศาสตร์ สถาบันเทคโนโลยีพระจอมเกล้าเจ้าคุณทหารลาดกระบัง.
ASTEROSEISMOLOGY and SEARCH for EXOPLANETS Vienna - September 18 th 2001 Optical performance characterization Point Spread Function (PSF) : Telescope +
Gas measurements and CsI photocathode studies at WIS Ilia Ravinovich November 2002 Weizmann Institute.
Improvement of Infrared Lights Sensitivity on PZT EMITER Daisuke Takamuro, Hidekuni Takao, Kazuaki Sawada and Makoto Ishida.
March 2004 Charles A. DiMarzio, Northeastern University ECEG287 Optical Detection Course Notes Part 15: Introduction to Array Detectors Profs.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
AMS-RICH Detector. J. Berdugo – CIEMAT (Madrid, Spain) 1 AMS-02 Phase II Flight Safety Review AMS Ring Imaging CHerenkov PURPOSE: 1.Precise measurement.
Multi-colour sctintillator-based ion beam profiler James Green, Oliver Ettlinger, David Neely (CLF / STFC) 2 nd Ion diagnostic workshop June 7-8 th.
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
ISUAL Sprite Imager Interface and Status Review Stewart Harris.
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 25 Digital Imaging.
TPC/HBD R&D at BNL Craig Woody BNL Mini Workshop on PHENIX Upgrade Plans August 6, 2002.
33mm MCP Testing at UC Berkeley
in collaboration with Jamie Holder & Vladimir Vassiliev
2007 detectors study at CERN 1.SiPM time resolution 2.MAPD S60 3.Blue sensitive MAPD 4.New 16ch board 5.New HV.
December 10, The Parallel Plate Chamber CERN Presentation Wout Kremers Detector R&D NIKHEF.
Plans to Test HBD Prototype in Run 6 Craig Woody BNL DC Meeting March 8, 2006.
Active Pixel Sensors in Medical and Biologi The application of Large Area Active Pixel Sensor (LAS) to high resolution Nuclear Medicine imaging Bob Ott.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Direct Digital Radiography or Direct Capture Radiography
PREPARED BY: Dhairya H. Giri. Introduction: In the Dark environment, it is highly impossible for Human Eye to see things clearly. For this reason, Night.
1 HMPID Project Assembly & Tests of CsI QE monitors: VUV-scanner and ASSET Milestone: December 2002.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Digital Imaging Instead of Radiography.
Charge Coupled Device (CCD) Prepared By: Sagar Reddy DOEACC B Level
SMART CAMERAS AS EMBEDDED SYSTEM SMVEC. SMART CAMERA  See, think and act  Intelligent cameras  Embedding of image processing algorithms  Can be networked.
Andrei Nomerotski 1 Pixel Imaging Mass Spectroscopy (PImMS) Mark Brouard, Ewen Campbell, Alex Johnsen, Craig Slater, Claire Vallance, Ed Wilman, Weihao.
ISUAL Imager Stewart Harris.
Imaging Characteristics
Field Emission Display Screen
Night vision goggles [1] Front Lens [2] Photocathode
BTF microbunching structure with Micro-Channel Plate PMT
Andy Clark, Jamie Crooks, Renato Turchetta
NVT capillary collimator NORTH NIGHT VISION TECHNOLOGY CO., LTD
S-D analog to digital conversion
How Things Work Night Vision
SLAC Program Review June 7, 2006 Kirk Gilmore Stanford/SLAC/KIPAC
Digital Artifacts.
Σ-D Analog to Digital Converter for CMOS Image Sensors Nonu Singh (RIT, MicroE Co-Op) Background After fabricating an imaging sensor it needs to be characterized.
SIDECAR ASIC Characterization Dan Pontillo
VC-B10U ePTZ USB 3.0 Camera.
Background Developed by Teledyne Scientific & Imaging, LLC
Detector development for
Jean-Francois Genat, Herve Grabas, Eric Oberla August 2d 2010
UCB Progress with 8” MCPs and Testing
SSL-UCB, ALD MCP Test Progress
Readout Electronics for Pixel Sensors
SIDECAR ASIC characterization
PYTHON25K: CMOS Image Sensor, 26.2 MP, Global Shutter
Readout Electronics for Pixel Sensors
Presentation transcript:

Detector development for a Lyman-a imager Udo Schühle Camera design: A CMOS-APS detector is mated with a micro-channel plate intensifier that is coated with KBr to increase efficiency around 121 nm and reduce the efficiency above 160 nm. The MCP-intensifier with a phosphor screen output window will be mated with the APS-sensor by a fiber-optic block. Sensor and electronics: STAR-1000 with 1024 x 1024 pixels electronic system designed and built entirely by MPS low-noise 14-bit ADC electronics USB interface for PC operation all radiation-hard design Intensifier testing: photocathode deposition (KBr, CsI) VUV testing and characterization, calibration Photocathode deposition chamber and VUV vacuum test chamber Selective photocathode coating and performance at 121.6 nm