Michael Sudakov and Sumio Kumashiro

Slides:



Advertisements
Similar presentations
Application of the Root-Locus Method to the Design and Sensitivity Analysis of Closed-Loop Thermoacoustic Engines C Mark Johnson.
Advertisements

FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Molecular Dynamics at Constant Temperature and Pressure Section 6.7 in M.M.
Sanja Risticevic Chem 323 Poster Presentation Quadrupole Ion Trap Mass Spectrometry.
Nuclear Magnetic Resonance
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Fusion Physics - Energy Boon or Nuclear Gloom? David Schilter and Shivani Sharma.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
A Miniature Ion Mobility Spectrometer for Explosives Detection Andrew Goodin, William F. Siems, Christina L. Crawford, Prabha Dwivedi, and Herbert H. Hill,
Signal Analysis and Processing for SmartPET D. Scraggs, A. Boston, H Boston, R Cooper, A Mather, G Turk University of Liverpool C. Hall, I. Lazarus Daresbury.
Mass Spectrometry.
Lecture 3 INFRARED SPECTROMETRY
MALDI-TOF-TOF with High Resolution Precursor Selection and Multiplexed MS-MS Poster Number ThP 618 Kevin Hayden, Stephen C. Gabeler, Mark Dahl and Marvin.
1 Ion Optics Simulations What it is. How it’s useful. The SIMION ion optics software. –How it works. –Limitations and cautions –Demonstrations and examples.
Large-amplitude oscillations in a Townsend discharge in low- current limit Vladimir Khudik, Alex Shvydky (Plasma Dynamics Corp., MI) Abstract We have developed.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, N.Kazarinov.
A Comparison between Electroluminescence Models and Experimental Results D. H. Mills 1*, F. Baudoin 2, G. Chen 1, P. L. Lewin 1 1 University of Southampton,
Mass Analyzers IV Quadrupole Ion Traps Chem 5181 – Fall 2007 J. Kimmel.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, A.Drozhdin, N.Kazarinov.
Mass Analyzers: Quadrupole ion trap?  
Molecular Deceleration Georgios Vasilakis. Outline  Why cold molecules are important  Cooling techniques  Molecular deceleration  Principle  Theory.
Double RF system at IUCF Shaoheng Wang 06/15/04. Contents 1.Introduction of Double RF System 2.Phase modulation  Single cavity case  Double cavity case.
Part III Commissioning. Proof of Principle FFAG (POP) study The world first proton FFAG –Commissioned in March –From 50 keV to 500 keV in 1ms. –Proof.
A mass-purification method for REX beams
Damping of the dust particle oscillations at very low neutral pressure M. Pustylnik, N. Ohno, S.Takamura, R. Smirnov.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Laboratory Study of Spiky Potential Structures Associated with Multi- Harmonic EIC Waves Robert L. Merlino and Su-Hyun Kim University of Iowa Guru Ganguli.
RF source, volume and caesiated extraction simulations (e-dump)
Förster Resonance Energy Transfer (FRET)
1.1 What’s electromagnetic radiation
NLC - The Next Linear Collider Project Keeping Nanometer Beams Colliding Vibration Stabilization of the Final Doublet Tom Himel SLAC NLC MAC review October.
FUNCTION GENERATOR.
Chemistry 13.1.
Laser Cooling and Trapping
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Weiming Guo Accelerator Physics Group / ASD Advanced Photon Source
Simulation of the Time Response of a VPT
Propagation of stationary nonlinear waves in disordered media
CLARIDGE CHAPTER 2.2; 3.2.
MoP-067 Michael Sudakov 1, R.Giles1 and Dimitris Papanastasiou2
Modelling of diagnostics for the ISIS ring
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Seok-geun Lee, Young-hwa An, Y.S. Hwang
Soft and hard mode switching in gyrotrons
CLIC Main Linac Cavity BPM Snapshot of the work in progress
Lock-in amplifiers
Muhammed Sayrac Phys-689 Modern Atomic Physics Spring-2016
SRL Simulations of High Resolving Quadrupoles with Collisional Cooling Interface and Fringing Fields. Michael Sudakov Shimadzu Research Laboratory (Europe)
UNIT - 4 HEAT TRANSFER.
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Chemistry 13.1.
Status of Equatorial CXRS System Development
NanoBPM Status and Multibunch Mark Slater, Cambridge University
Chemistry 13.1.
FERMI-DIRAC DISTRIBUTION.
Ion Motion Through an RFQ
10.5 Fourier Transform NMR Instrumentation
10.6 Fourier Transform Mass Spectrometry
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
November 14, 2008 The meeting on RIKEN AVF Cyclotron Upgrade Progress report on activity plan Sergey Vorozhtsov.
November 7, 2008 The meeting on RIKEN AVF Cyclotron Upgrade Progress report on activity plan Sergey Vorozhtsov.
8.6 Autocorrelation instrument, mathematical definition, and properties autocorrelation and Fourier transforms cosine and sine waves sum of cosines Johnson.
Mass Spectroscopy tutorial
Lecture 6 ACCELERATOR PHYSICS HT E. J. N. Wilson
Kinetic Theory and a Model for Gases
CAL crosstalk issues and their implications
Strategic Communications at TRIUMF
Presentation transcript:

Simulations of High Resolution Resonance Ejection Scan in a Digital Ion Trap . Michael Sudakov and Sumio Kumashiro Shimadzu Research Laboratory (Europe) Ltd., Manchester, UK. E-mail: m.sudakov@srlab.co.uk Overview Recently a prototype of Digital Ion Trap (DIT) was developed in SRL [1]. This ion trap is driven by square wave supply and uses a novel method of frequency scan with a linear mass scale, which theoretically does not have limitations of mass range from high mass side. Unlike all existing commercial ion traps, DIT uses theoretical geometry of electrodes. Instead of deliberate modification of electrode geometry a novel Field Adjusting method is used in DIT. DC field penetration from an external electrode trough the entrance hole allows making the secular frequency of ion oscillation almost independent of amplitude thus providing conditions of high-resolution resonance excitation. A new approach for building ion trap instrumentation requires investigation both by means of experiment and simulations. Methods Simulation Model A simulation was performed with the use AXSIM-2 software. AXSIM uses fields refined by SIMION-7.0 for the actual electrode geometry of DIT prototype. In preliminary study [2] it was found that potential arrays with a grid step of 50mm and with a grid step of 25mm give similar results, hence the grid step of 25mm was used all over this study. Like in SIMION, AXSIM uses linear interpolation for electrical vector from the grid. An RKF4 integration procedure was used with a fixed integration step. Consequently, present simulation is equivalent to SIMION simulation with fixed integration step (“trajectory quality” zero). AXSIM-2 is optimised for multi-particle ion trap simulations. It features accurate hard sphere model of ion collisions with buffer gas particles [3], which was tested in separate simulations for correct Maxwell distributions of particles in absence of electrical fields and for correct values of mobility and diffusion coefficients. AXSIM-2 allows fast and accurate simulation of ion motion in RF fields with conventional RF voltage scan or Square Wave with frequency scan under digital control, allows simulating of complicated resonance excitations and DC signals. User interface of AXSIM allows visualizing the particle motion in a real space and investigating the nonlinear motion by Phase space and Fourier transform analysis. All this makes AXSIM-2 a powerful tool for simulations of RF ion traps, quadrupoles and other ion optics devices. For optimisation of resonance ejection scan a simulation of DIT was prepared with all signals which may affect resolving power (see numbers of corresponding electrodes on fig.1): 1) RF supply on the ring electrode: +/-1000V Digital Square Wave (frequency scan) 2) Pulsed dipole excitation, each 4th period of RF 0/-1.2V (pulse width variable) 3) Field Adjusting voltage: DC signal (variable) 4) Focusing Electrode Voltage: DC singal –100V 5) Detector Entrance Voltage: DC signal –1.5kV Fig.1. DIT schematic with major power supplies x 14.14mm FA +1kV -1kV Digital SQW -100V -1.5kV Pulsed Dipole and Waveform Generator -2kV… +2kV 7bit to Detector from Ion Source 1 2 3 4 5 Ions of mass 1562Da (singly charged) were used for present simulation study. Cross section of ions was taken 500sq.A. Ion trap is filled with He buffer gas at temperature 300K. Buffer Gas pressure optimisation Field Adjusting Voltage optimisation and comparison with Experiment In first series of simulations the gas pressure inside the trap was optimised for best resolving power in a scan with speed 1000Da/s. In this simulation 1000 ions are flown until they hit detector. Detector has a fixed sampling time of 50ms. Each ion contributes into a peak shape according with it’s time of flight. Parameters of the scan was adjusted in such a way, that ejection of ions starts approximately 30ms from the beginning of scan. Typically 10ms is sufficient for complete cooling. Consequently all ions loose any memory of initial conditions far before the ejection. Simulation was repeated many times with different pressure of the buffer gas, while all other simulation parameters were fixed as well as initial conditions of ions. Results are presented in fig.2, fig.3, fig.4. In a second series of simulations the scan was further optimised for best resolution at constant buffer gas pressure of 0.1mTorr. Variable parameter in this simulation was the voltage of Field Adjusting electrode (FAE). Results are presented in fig.5, fig.6. Fig.5 Fig.6 Comparison with experiment Fig.2 Fig.3 Fig.4 It was found that the peak shape and peak position is sensitive to a FAE voltage. With non optimised FAE voltage the resolving power of the scan is only 1000. At certain value of FAE voltage resolution suddenly improves by an order of magnitude. Optimum value of FAE voltage according with present simulation lies between 1100V and 1400V. Simulation was confirmed by the experiment on DIT prototype [1] with Glu-fibrinopeptide B ions. Comparison of experimentally measured resolution (FWHM) with simulation is presented in fig.6. Experiment shows nice agreement with simulations, although the maximum resolving power is slightly smaller. Optimum value of FAE voltage for best resolution slightly varies depending on scan speed. Higher resolution can be achieved by reducing the scan speed. Resolving powers over 19.000 was achieved on DIT prototype for very slow scans (39Da/s). Peak position is sensitive to buffer gas pressure and resolving power is improved at lower pressures. Not all ions are ejected with dipole excitation of 1.2V at pressures over 0.3mTorr. They will be ejected at the boundary of stability contributing to “ghost” peaks. In further simulations He pressure of 0.1mTorr was used. Fourier Transform analysis of Ion Vibrations (Frequency Shift Correction). Phase Space Analysis of ion motion (Attractive Cycles). In order to reveal the mechanism of field adjustment the ion motion at the point of ejection was investigated. Ejection of 1562Da ions happens at 33ms from the beginning of frequency scan with present simulation settings. Period of square wave at 33ms was calculated to be 2.8224ms. Secular frequency of ions can be calculated using Fourier transform method [4] depending on amplitude of ion vibrations in Z direction. Results of such calculations with and without FAE voltage are presented in fig. 7. Investigation of ion motion in a phase space (z,vz) further reveals the dynamics of resonance ejection scan. Motion of a single ion 1562Da was simulated for a long time (16.000 cycles) without dipole excitation and random collisions. Weak damping was introduced in order to reduce kinetic energy of vibrations slowly without modifications to the phase-space structure. Ion position was sampled in the middle of negative pulse on the ring electrode and plotted in configuration space (z,vz). Results are presented in fig.9 a,b. Fig.7. Frequency shift in the ion trap with holes Fig.8. Field Adjusting potential Fig.9 Phase space motion of ion at conditions of best resolution in DIT. A) Small amplitude of vibrations. B) Big amplitude of vibrations. A. B. Small and medium vibrations High amplitude vibrations: Negative frequency shift due to holes Map: 1V +1200V 0V It was found that ion with small amplitude of vibrations gradually loose energy and approach the middle of the trap (fig.9.A). In contrast ion with big amplitude appears to be “trapped” in a regions of phase space that correspond to a stable nonlinear motion (fig.9.B). Frequency of ion vibrations in such state exactly equals to ¼ of the RF frequency. Ion can not escape from this state unless trapping conditions will change (RF period or FAE voltage). Existence of these regions was confirmed by simulations of resonance ejection scan for a triplet of ions with masses 1561Da, 1562Da and 1563Da (500 ions of each mass) Results are presented in fig.10. It follows that in the ion trap with holes the secular frequency of ions shifts to lower values at high amplitude of ion vibrations when ion approaches hole regions (see red line in fig.7). The shift can be as big as several percent. Due to this ejection of ions is delayed and resolving power is poor because ion fall out of resonance with excitation field just on the verge of ejection. Simulations show that ion approaches hole region many times prior to ejection. Oscillation of ion with high amplitude in presence of buffer gas results in heating of the internal degrees of freedom and subsequent fragmentation. Fragments become immediately unstable in RF field and hit detector. In this case, peak position depends on ion fragility. Ions of the same mass-to-charge ratio but different collision cross-section appear at slightly different position in a spectrum. This phenomena is know as “chemical mass shifts” [5] and all commercial ion traps have deliberately distorted geometry in order to avoid this problem. In a DIT a method of field adjusting was used to overcome this effect. Positive voltage from FAE penetrates into the volume of the ion trap like shown on fig.8. DC field modifies the shape of the potential well so as to produce frequency shift to higher values (positive frequency shift) when ions approach hole regions. Although the negative frequency shift can not be removed completely, appropriate voltage on FAE provides conditions of high-quality resonance all the way to ejection hole (see blue line on fig.7). As a result ions are ejected almost simultaneously and mass spectra features high resolution and negligible chemical shifts. Thus FAE appears as a general new method of achieving high resolution spectra in ion traps with theoretical geometry and inevitable distortions from ejection holes and slits. A. 31.7ms beginning of ejection for 1561Da ions B. 32.0ms ejection of 1562Da ions. C. 32.4ms – end of ejection for 1561Da ions D. 33ms – ejection of 1562Da ions. Ions on the verge of ejection Ions trapped in a cycle One can see from fig. 10.D, that some ions of 1561Da appear to be trapped near the regions of nonlinear stability after ejection of the main group. These ions will contribute to the noise floor in the spectrum or they will produce “ghost” peaks. Existence of nonlinear cycles is specific for resonance ejection at ¼ frequency of the RF and it follows that this is not the best solution for resonance ejection scan in a nonlinear ion traps. Better result can be achieved at higher ejection q values. References. Conclusions [1] Li Ding, M. Sudakov, F. Brancha, R. Giles and S. Kumashiro, A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources, J. of Mass Spectrometry, vol.39, p.471-484, 2004 [2] Li Ding, M. Sudakov and S. Kumashiro, A Simulation study of the digital ion trap mass spectrometer, Int. J. of Mass Spectrometry, v.221, No.2, pp.117-139, 2003 [3] J.H. Parks and J Szoke, Simulation of Collisional Relaxation of Trapped ion Clouds in presence of Space Charge Effects, J. Chem. Phys., v. !03, pp.1422-1439, 1995 [4] M.Sudakov and S.Kumashiro, Theory and Simulations of Resonance Excitation in Nonlinear and Pure Quadrupole Traps. Part II., 16 Int. MS Conference, Edinburgh, September 1-5, 2003 [5] W. Plass, H. Li and R.G.Cooks, Theory, simulation and measurement of chemical mass shifts in RF quadrupole ion traps, Int. J. of Mass Spectrometry, v.228, pp.237-267, 2003 A Simulation model of a Digital Ion trap was developed with the use of SIMION potential arrays, Square Wave RF with possibility of frequency scan, Pulsed dipole excitation at ¼of the main trapping frequency, and accurate Monte-Carlo modelling of ion-buffer collisions using hard-sphere approximation. Resonance ejection of 1562Da ions using frequency scan under digital control was optimised for best resolution. Experiment on DIT prototype shows good agreement with simulation. Ion motion under conditions of best resolution was investigated using Fourier Transform and Phase Space analysis. It was found that Field Adjusting is a general method to correct for negative frequency shift in ion traps with holes. Areas of stable nonlinear vibrtions (cycles) in phase space were observed at high amplitude of vibration at optimum conditions for resolution. Cycles correspond to ion vibration with frequency exactly equal to ¼ of the main trapping frequency. Existence of attractive cycles was found to be unfavourable for resonance ejection scan. The use of resonance ejection at higher q values (higher resonance frequencies) is proposed.