Yuzhe Liu1,2, Lian Chen1,2, Futian Liang1,3, Feng Li1,2, Ge Jin1,2

Slides:



Advertisements
Similar presentations
Constructing an Analog Digital Converter (ADC) to Measure Neutron Depolarization in Deuterium Aung Kyaw Sint and Dr. Alexander Komives CsI scintillator.
Advertisements

Analog-to-Digital Converter (ADC) And
Figure 5. Histogram of the decay constant. Black curves: raw histograms; Blue curve: Gaussian fit to the histogram from the 20GS/s waveform; Red curve:
A scalable DAQ system using the DRS4 sampling chip H.Friederich 1, G.Davatz 1, U.Hartmann 2, A.Howard 1, H.Meyer 1, D.Murer 1, S.Ritt 2, N.Schlumpf 2 1.
Harbin Institute of Technology (Weihai) 1 Chapter 2 Channel Measurement and simulation  2.1 Introduction  Experimental and simulation techniques  The.
EE 198 B Senior Design Project. Spectrum Analyzer.
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Engineering 1040: Mechanisms & Electric Circuits Winter 2015 Analog & Digital Signals Analog to Digital Conversion (ADC)

FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
The Readout Electronics for Upgrading of BESIII End-capTOF Chunyan Yin University of Science and Technology of China University of Science and Technology.
Communications Systems. 1Analogue modulation: time domain (waveforms), frequency domain (spectra), amplitude modulation (am), frequency modulation (fm),
Instructor: Evgeniy Kuksin Preformed by: Ziv Landesberg Duration: 1 semester.
QuarkNet and Cosmic Ray Muon Flux Experiments Florida Academy of Sciences Spring Conference 2009 Alfred Menendez and Michael Abercrombie with Dr. Marcus.
Digital Voltmeter (DVM)
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
The requirements of Ideal pulse-type counter :  1 Every particle entering the detector should produce a pulse at the exit of the counter,
A Multi-Threshold Method for TOF-PET Signal Processing Heejong Kim 1, Chien-Min Kao 1, Qingguo Xie 1, Chin-Tu Chen 1, Octavia Biris 2, Jialin Lin 2, Fukun.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
RT 2009, 15 th May 2009 Pulse Pile-up Recovery Using Model-Based Signal Processing. Paul. A.B. Scoullar, Southern Innovation, Australia. Prof. Rob J. Evans.
 A) Pulse Height Spectroscopy  Identify the equipment such as detector, electronics modules and NIM.
Lecture Notes / PPT UNIT III
For more course tutorials visit ECET 310 Entire Course (Devry) For more course tutorials visit ECET 310 Week 1 Homework.
FOR MORE CLASSES VISIT  ECET 310 Week 1 Homework 1_1  ECET 310 Week 1 Homework 1_2  ECET 310 Week 2 Assignment Homework 2_1.
 13 Readout Electronics A First Look 28-Jan-2004.
ECET 310 Entire Course For more classes visit ECET 310 Week 1 Homework 1_1 ECET 310 Week 1 Homework 1_2 ECET 310 Week 2 Assignment.
A SEMINAR TOPIC ON LANDMINE DETECTION USING IMPULSE GROUND PENETRATING RADAR A SEMINAR TOPIC ON LANDMINE DETECTION USING IMPULSE GROUND PENETRATING RADAR.
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Mrs V.S.KharoteChavan,E&Tc,PC poly
The dynamic range extension system for the LHAASO-WCDA experiment
Transient Waveform Recording Utilizing TARGET7 ASIC
Content: Distortion at electronic loads
EKT124 Digital Electronics 1 Introduction to Digital Electronics
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
A 2 Gsps Waveform Digitizer ASIC in CMOS 180 nm Technology
Jinfan Chang Experimental Physics Center , IHEP Feb 18 , 2011
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
QuarkNet and Cosmic Ray Muon Flux Experiments
Principles of Instrumental Analysis
Shubin Liu, Binxiang Qi, Siyuan Ma, Zhongtao Shen, Guangyuan Yuan,
Telemetry Principles Zankhana Mehta.
L. Ratti, M. Manghisoni Università degli Studi di Pavia INFN Pavia
Natural CMO+HPGe experiment
A Readout Electronics System for GEM Detectors
Outline 1. Introduction & Overview 2. The experiment result 3. Future
Introduction What is an oscilloscope?.
Data Acquisition System for Gamma-Gamma Physics at KLOE
Data transmission and telemetry
Development and Test of Simultaneous Power Analysis System for Three-Phase and Four-Wire Power System Hun Oh1, In Ho Ryu2 and Jeong-Chay Jeon3* 1Department.
Shanshui Yang1, Li Liu1, Xi Jiang1, Li Wang1, Weifang Liu2
Measurements of digital signals with spectrum analyzers
A Low Power Readout ASIC for Time Projection Chambers in 65nm CMOS
ELECTRON SPIN RESONANCE Dylan Prendergast Advanced Lab, Fall 2007
Nickel Concentration Measurement in Water Sample using BGO detector
Neutron Detection with MoNA LISA
Multichannel Pulse Analysis
Multichannel Pulse Analysis
BESIII EMC electronics
Measurements of digital signals with spectrum analyzers
Chapter No. 10 General description of electronic units used in radiation measurements. viewpoint of ‘ input-output'-i.e., the input and output signals.
Digital instrumentation – Unit 1
Analog and Digital Instruments
A Multi-Threshold Method for TOF-PET Signal Processing
Digital Fundamentals Floyd Chapter 1 Tenth Edition
Data Acquisition (DAQ)
DIGITAL ELECTRONICS, MICROPROCESSORS, AND COMPUTERS
1.5.4 The High-Voltage Power Supply : The high-voltage power supply (HVPS) provides a positive or negative voltage necessary for.
DAQ and visualization software
Presentation transcript:

High Counting-rate Data Acquisition System for the Applications of PGNAA Yuzhe Liu1,2, Lian Chen1,2, Futian Liang1,3, Feng Li1,2, Ge Jin1,2 1.Modern Physics Department, University of Science and Technology of China, Hefei, Anhui, 230026 2.State Key Laboratory of Technologies of Particle Detection and Electronics 3. National Laboratory for Physical Sciences at the Microscale The shaping circuit transforms the impulse signal outputted by the PMT into a quasi Gauss pulse, in order to improve the SNR and reduce the effect on energy resolution of the electric noise. This system uses a 14 bits high speed FADC circuit, which has a sample rates of up to 250 MSPS. Furthermore, the analog-to-digital converting, peek seeking and multi-channel analysis are operated as a pipeline. Prompt Gamma-ray Neutron Activation Analysis (PGNAA) technique is a non-destructive nuclear analysis technique for the determination of elements. As an on-line and in situ inspection method, the PGNAA technique need to acquire an accurate spectral information in a relatively short measurement time. That demands a high counting rate and little counting loss of the data acquisition system. Fig.1 Block Diagram of PGNAA Readout System.

Electronic Tests a b c d Fig.2 The signal outputted by the shaping circuit, a 5MHz, b 6MHz, c 7MHz, d 8MHz. The highest counting rate is consistent with the frequency of the signal generator when the pulses becoming connected together. As is shown in Fig. 2, the highest counting rate reaches 8Mc/s. The standard deviation of liner fitting of non-linearity test is 1.23mV, while the relative error is lower than ±1.5%, which is lower than ±0.5% in the middle and high channel range. In order to conform that the DAQ system can achieve a highest counting rate of 5Mc/s, an electronic test of counting rate is implemented with an Agilent 33250A signal generator as signal source and Tektronix MDO3032 Oscilloscope to observe the output pulses. The test result shows the system is well to meet the accuracy requirements. And the non-linearity can be improved roughly an order of magnitude using a sliding pulse generator Fig.3 The linearity (left) and the relative error (right) test of the readout system.

Experimental Results The output signals of PMT is shaped by the front electronic circuit. Then the voltage signals outputted from the front electronic circuit are transmitted to both the DAQ system and the ORTEC LanBase commercial multi-channel analyzer. The energy spectrum acquired by both analyzer are shown below. Fig.4 The sketch map of the energy spectrum acquiring experiment Hydrogen Peak Resolution 8.9% : 9.3% Counting Rate 40.5K/s :37.4K/s Dead Time <1% : 14.7% An energy spectrum of aqueous solution is record in another experiment in low fidelity environment The aqueous solution of urea and sucrose is filled in the barrel tank which has a neutron tube through the bottom horizontal. There are a He3 detector and a scaler monitoring the neutron flux of the tube. The BGO detector and PMT transfer the gamma ray into electric pulse, which is shaped by the front electronic circuit. The output pulses of front electronic circuit are transmitted to both the DAQ system and the ORTEC LanBase commercial multi-channel analyzer. The energy spectrum of both analyzer are shown in Fig.5 & 6 Fig.5 The energy spectrum acquired by PGNAA DAQ. Fig.6 The energy spectrum acquired by ORTEC LanBase The result of this experiment indicates that the PGNAA DAQ system can achieve a higher counting rate with much less dead time and guarantees a good accuracy in the same condition.

Poster Introduction Shaping Principle Experimental Results System Design Electronic Test