Inter-laboratory comparison exercise cpc calibration material: 2nd stage Focus on soot as harmonized calibration material for Automotive PN counters. Generators:

Slides:



Advertisements
Similar presentations
ASHRAE Round Robin 2011 Round Robin.
Advertisements

Documentation Control and Quality Control Presented by Shane Tyler and Gary Russell.
Calibration of an Infrared-based Automatic Counting System for Pedestrian Traffic Flow Data Collection Step 3: Calibration Models Calibration models were.
1 NCSLI Conference 2013 Inter-Laboratory Comparison Study Using Modular Instrumentation and Lessons Learned Author:Dimaries Nieves – National Instruments.
Institute for Energy and Transport B. Giechaskiel, G. Martini
RETROCOMMISSIONING AIR HANDLING SYSTEMS
Chamber background – brand new bag (first day of use)
1 Motivation Particles are generally regarded as one of the most serious indoor air quality concerns Increasing concern about ultrafine particles Very.
CPC Calibration – SI Traceability Hans-Georg Horn TSI GmbH, Aachen, Germany.
ISRAEL ELECTRIC CORP. METER TESTING LABORATORIES DEPARTMENT STANDARDS LABORATORY.
1 The Result of Japan’s Round Robin Engine Test: Measurement of PM and PN 3/30/2009 PMP Informal Meeting National Traffic Safety and Environmental Laboratory.
Repeatability and Reproducibility Analysis of the Round Robin Results.
WLTP DTP PM-PN Subgroup Activities, Progress & Future Plans 7 th DTP Meeting Bern 12 th – 14 th September 2011 Chris Parkin.
PMP Progress Report Activities since GRPE 58 Heavy Duty Validation testing Exercise completed in October Draft report and draft proposal to insert PN measurement.
$100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300.
$100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300.
Summary of the latest PMP related activities Giorgio Martini, Athanasios Mamakos* Institute for Energy and Transport Joint Research Centre * Southwest.
GRPE 71 ST SESSION PMP INFORMAL GROUP PROGRESS REPORT TO GRPE 8 Jan 2015 Informal document GRPE st GRPE, 8-12 June 2015,
1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1.
37 TH PMP MEETING Institute for Energy and Transport Joint Research Centre B. Giechaskiel, G. Martini 7 Oct 2015.
ASCOS planning meeting, 8 th April 2008 IAC ETH Single Particle Chemical Characterization and Measurements of Cloud Condensation Nuclei Berko Sierau, Maria.
Joint Research Centre the European Commission's in-house science service JRC Science Hub: ec.europa.eu/jrc 38th UNECE IWG PMP MEETING Exhaust emissions.
Quality Management & Operations Support Branch Quality Assurance Section Presented By: Webster Tasat.
© 2009, TSI Incorporated PMP PNC Calibration Recent Experiences Hans-Georg Horn TSI GmbH, Particle Instruments PMP Meeting, London, 30 March 2009.
RDE PN-PEMS programme Progress Update F. Riccobono, B. Giechaskiel, P. Bonnel STU, IET, JRC, European Commission.
LNG Mass Flow Standard Improving the “kilogram” for LNG Dushyant Parkhi Flow Engineer VSL.
The Traceability of Conductivity Meter and Cell Calibration in the Low Conductivity Ranges Jun Bautista, Director, Genzyme Metrology Genzyme Corporation,
Calibrating DC Current Shunts: Techniques and Uncertainties Jay Klevens, Ohm-Labs, Inc. © 2011.
Challenges Evolving from ASHRAE 52.2 Test Method
PN-Calibration Issues
PMP IWG Progress Report
PMP IWG Progress Report
Technical justifications for accreditation
Excellent Healthcare Service: A structured approach through ISO Accredited Biomedical Laboratory 17 February 2016 Presented: Roziah Abdul Latiff.
Part 3 LABTQ /LABNET. Technical experience with testing ECO design parameters 20 years of Round Robin test on boilers and collaboration in LABNET/LABTQ.
43rd PMP-Meeting Rosa Delgado IDIADA 15/03/ /03/2017 TITLE
PMP IWG Progress Report
PMP IWG Progress Report
APEC Workshop Renewable energy
20 years of Round Robin test on boilers
Particle Measurement Programme - Report
Institute for Energy and Transport B. Giechaskiel, G. Martini
Preliminary results of the OEMs HDV PN-PEMS validation study
76th UNECE GRPE session PMP IWG Progress Report
76th UNECE GRPE session PMP IWG Progress Report
Exhaust Emissions Light Duty-PMP-2017/2018 Sub23nm Round Robin
Light Duty-PMP-2017/2018 Sub23nm Round Robin
PMP IWG Progress Report
Systems Design Review : Heart Pump and Circulatory System
Additional evaluations at AVL
HD ENGINE RAW PN MEASUREMENT
WLTP DTP PM-PN Subgroup Activities, Progress & Future Plans
Tim Hewison1 (1) EUMETSAT
Software Engineering Lecture #14.
Exhaust Emissions Light Duty-PMP-2017/2018 Sub23nm Round Robin
LDV Real Driving Emissions: - Drafting of physical PEMS protocol –
PMP sub-group on CPC calibration
Inter-Laboratory Comparison Exercise CPC CALIBRATION
Variability in 52.2 Testing
PMP – PN sub 23nm Route to transfer from ‘in case of urgent need’ into planned delivery into regulations PMP-48 Presentation from Technical Secretary.
PN-PEMS Progress update
Supplemental Test for Determination of CO2 Emissions under Regional Conditions Results from Telco Oct. 30th, 2014 (Iddo, Markus, Helge, Andreas)
PN Counting from Raw Exhaust via Fixed Dilution and PMP Round Robin Project JRC and ACEA.
Current status All European laboratories (except 3rd JRC measurement) have conducted their measurements Equipment finally returned to JRC US, Japanese.
Proposed actions for gtr development
Reporting QA Measures to EBAS – and a Word on Flagging
50th Particle Measurement Programme Informal Working Group Meeting
ACEA and JRC PMP meeting 7/11/2018
PNC and VPR Validation PMP Meeting 30th March 2009
Presentation transcript:

Inter-laboratory comparison exercise cpc calibration material: 2nd stage Focus on soot as harmonized calibration material for Automotive PN counters. Generators: Various miniCAST & Palas DNP Goal: The calibration uncertainty of “best practice” soot calibration Apply Lessons Learned from first round: Focus on Counting Efficiency Validate DMA Traveling flow meter Less tests Only two CPCs: 1 reference, 1 device under test Standardized data collection Terres: CPC Calibration Round Robin | Proposal of second stage | 2017-05-22

Inter-laboratory comparison exercise cpc calibration material: 2nd stage Basic procedure: Calibration of circulated EE CPC (D50=23nm) against circulated reference CPC (D50=10nm) with in-house CAST/Palas soot generator Counting efficiency curve, focus on 23nm and 41nm. Possible extras: 10/15/70nm same set-up variance (at BMW) Circulated devices (possible provider): Reference CPC (D50: 10nm) (TSI?) Engine Exhaust (EE) CPC (D50: 23nm) (BMW?) PSL vaporizer + traceable PSL particles to check DMA (PTB?) Flow meter (BMW?) Laptop + data collection software “XERO” (Amium?) Temperature/pressure/humidity sensor (connected to laptop) (Amium?) Circulated reference Circulated device under test Terres: CPC Calibration Round Robin | Proposal of second stage | 2017-05-22