Qiuli Yu, Jay Teixeira, and Ed Geer

Slides:



Advertisements
Similar presentations
New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
Advertisements

Understanding Electrical TransmissionDemonstration D1 A Guide to the National Grid Transmission Model Demonstration D1 Power losses in transmission.
Presented to PGDTF February 11, 2015
Announcements Be reading Chapter 6. HW 3 is due now.
Parameter Scaling Most filter designs are given in a normalised form, i.e. for a cut-off frequency of 1 rad/s. To transform for an arbitrary frequency,
Problem #2-8 A 480 – 120 V, 60 Hz transformer has its high voltage winding connected to a 460 V system, and its low voltage winding connected to a 24/32.8°Ω.
Lesson 37 AC Generators II
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Power Triangle.
Example 1 A 9375 kVA, 13,800 kV, 60 Hz, two pole, Y-connected synchronous generator is delivering rated current at rated voltage and unity PF. Find the.
Power System Modeling of GMD Impacts Thomas J. Overbye University of Illinois at Urbana-Champaign April 7, 2015.
Development of a Real-Time GIC Simulator D. H. BOTELER 1, R. PIRJOLA 2, J. PARMELEE 1, S. SOUKSALY 1 1 Geomagnetic Laboratory, Natural Resources Canada.
Integration of Geomagnetic Disturbance (GMD) Modeling into the Power Flow Thomas J. Overbye Fox Family Professor of Electrical and Computer Engineering.
1 TSP Nodal Engagement Market Participant Call ERCOT August 04, 2010.
1 ECE 3336 Introduction to Circuits & Electronics Set #16 Transformers Fall 2011, TUE&TH 4-5:30 pm Dr. Wanda Wosik.
Author Vilcahuaman.Melendez Country PE Session V – Block 2 – Question 23 Barcelona May THREE-PHASE DISTRIBUTION POWER FLOW WITH A GEOGRAPHIC.
RARF Frequently Asked Questions from Resource Entities Ed Geer RARF Workshop III 8/29/2013.
Learning Objectives: What is a Transformer? How is a current induced in the secondary coil? Is there a relationship between the number of coils and the.
Announcements Homework #4 is due now Homework 5 is due on Oct 4
SPWG SHORT CIRCUIT CASE BUILDING AND DEVELOPMENT July 17, 2014 Qiuli Yu and Jay Teixeira ERCOT.
Status Update: Using NMMS for Building SSWG Cases Wes Woitt CenterPoint Energy 2010 SSWG Chair.
PSS/E RAW File Format for appending to case
Elec467 Power Machines & Transformers Electric Machines by Hubert, Chapter 12 Topic: Self-excited and compound generators, load distribution.
3/17/2014 PHYS , Dr. Andrew Brandt 1 PHYS 1442 – Section 004 Lecture #15 Monday March 17, 2014 Dr. Andrew Brandt Chapter 21 Generator Transformer.
BASIC ELECTRICAL TECHNOLOGY DET 211/3 Chapter 6: Single Phase Transformer (Continued)
Optimal Power Flow- Basic Requirements For Real Life.
ELEC 3105 Basic EM and Power Engineering Rotating DC Motor PART 2 Electrical.
Material for 10/23/2015 PGDTF Meeting Michael Juricek.
Chapter 14 Physics A First Course Electricity. Electricity Electrical Systems 14.1 Series Circuits 14.2 Parallel Circuits 14.3 Electrical Power, AC, and.
Transformer The working principle of a transformer
Lecture 04Electro Mechanical System1 Ideal Transformer  An ideal transformer  Transformer has no losses and core is infinitely permeable  All fluxes.
ELECTRICAL MACHINE DET 204/3 JIMIRAFIZI BIN JAMIL Transformer CHAPTER 1.
Status Update to ROS: Using NMMS for Building SSWG Cases Wes Woitt CenterPoint Energy 2010 SSWG Chair.
ERCOT PUBLIC 3/25/ RTP Inputs and Assumptions March 25, 2014.
POWER CIRCUIT & ELECTROMAGNETICS EET 221 Transformer.
Data Requirements For Calculating Geomagnetically Induced Currents ROS Meeting March 3, 2016 Michael Juricek PGDTF Chairman 1.
Data Requirements For Calculating Geomagnetically Induced Currents PGDTF Meeting March 21, 2016 Michael Juricek PGDTF Chairman 1.
Siemens PTI GIC Data File Contents Presented to PGDTF February 11, 2015.
6. Unregulated Power Supply Design
Question 1 a.Find the magnitude of phase voltage and current b.Find the average power to each phase and the total load. c.Determine the reactive power.
Chapter 13 Ideal Transformers
Nodal Planning Go Live Austin, TX February 3, 2011
Planning Geomagnetic Disturbance Task Force (PGDTF) Update to the ROS
Chapter 13 Ideal Transformers
GIC System Model Workshop
Planning Geomagnetic Disturbance Task Force (PGDTF) Meeting Material
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
Ideal Transformers Chapter Objectives:
Lesson 34: AC Generators II
ELEC 3105 Basic E&M and Power Engineering
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Electric Machine Transformers
GIC Analysis using PSS®E
ECE 476 POWER SYSTEM ANALYSIS
PSS®E Update for WECC Good morning, welcome to psse presentation for the UGM I’m glenn pietrow, PSSE product manager and GUI developer Currently manage.
Design of Electric Power Systems and Utilities
Load Flow Studies Eng. Edvan Moyo BEng, MEng, MBA
Energy Conversion and Transport George G. Karady & Keith Holbert
Ch. 13 – Ideal Transformers
Exercise 8 Power systems.
Accurate Fault Location Using Modeling and Simulation
Lecture No 8.
Utilisation of Electrical Energy
Source Transformation
Exercise 8 Power systems.
PSS®E Update for WECC Good morning, welcome to psse presentation for the UGM I’m glenn pietrow, PSSE product manager and GUI developer Currently manage.
Chapter 14.
M. Kezunovic (P.I.) S. S. Luo D. Ristanovic Texas A&M University
PRACTICAL TRANSFORMER
Example Example 1: An electric lamp is rated 110 W, 200 V. When the lamp is operated at its rated power and voltage, calculate a) the current flowing through.
Presentation transcript:

Qiuli Yu, Jay Teixeira, and Ed Geer PGDTF MEETING – Mar 2016 GIC Model Development Qiuli Yu, Jay Teixeira, and Ed Geer ERCOT March 21, 2016

TOPICS Draft GIC Model Development Issues With Draft GIC Model Introduction Input Data Output Data Issues With Draft GIC Model PSSE V34 vs. V33 Default Data vs. Real Data

Draft GIC Model Development Introduction GIC model is an dependent on ERCOT network model base case Use SSWG 15DSA_2015_SUM1_TPIT_Final_02242015 as base case This base case is for summer peak load The GIC input file has to be run above the SSWG base case GIC input/output are based on PSSE v33 GIC module GIC input file has been run using PSSE v33, which has the minimum data requirement Use the same PSSE version as for SSWG base case development

Draft GIC Model Development Input Data for V33 Substation Data Geographic coordinates, not geomagnetic coordinates Don’t have real substation grounding resistance data, assuming all 0.1 Ω Bus – Substation Mapping Data Bus numbers are assigned in SSWG base case development Over 100 buses are missing assigned substations in SSWG Substation numbers are created arbitrarily but can be fixed to a NMMS ID Will keep the substation number the same for future GIC models BUSNUMBER SUBNUMBER 1 3292 2 1986 4 1883 5 3380 6 1843

Draft GIC Model Development Input Data for V33 Transformer Data Default data extracted from PSSE GIC Module Most VECGRPs are missing in SSWG base case CORE and KFACTOR data don’t exist in SSWG base case I J K CIRCUIT WRI WRJ WRK GICBDI GICBDJ GICBDK VECGRP CORE KFACTOR 36 35 '1 ' 0.1321 0.5285 'YNyn0 ' 48 47 0.1816 0.7264 92 91 0.0614 0.2457 131 130 133 132 0.123 0.4542 202 203 0.4431 1.6368

Draft GIC Model Development Input Data for V33 Transformer Data

Draft GIC Model Development Output Data The output was calculated based on Uniform electric field = 8.00 V/km Orientation: 45 ̊Northeast Select all six outputs:

Draft GIC Model Development Output Data Output summary and Branch induced DC voltages

Draft GIC Model Development Output Data Bus and Substation ground bus DC Voltages

Draft GIC Model Development Output Data GIC flow in Non-Transformer Branches, flowing from From Bus to To Bus

Draft GIC Model Development Output Data GIC flow in Shunts and 2-W Transformer, flowing from Bus to Neutral

Draft GIC Model Development Output Data GIC flow in 3-W Transformer and 3-W Auto Transformers

Draft GIC Model Development Output Data GIC flow in Substation Ground

Draft GIC Model Development Output Data 2-W Transformer Reactive Power Loss

Draft GIC Model Development Output Data Transformer Reactive Power Loss Summary

Issues With Draft GIC Model PSSE V34 vs. V33: Earth Model (EARTHMDL) in Substation Data Section

Issues With Draft GIC Model PSSE V34 vs. V33: Winding Grounding DC Impedances (GRDWRI, GRDWRJ, and GRDWRK) and Transformer Model (TMODEL) in Transformer Data Section

Issues With Draft GIC Model PSSE V34 vs. V33: Bus Fixed Shunt Data Section

Issues With Draft GIC Model PSSE V34 vs. V33: Branch Data Section

Issues With Draft GIC Model Default Data vs. Real Data: Substation Grounding DC Resistance Transformer Winding Grounding DC Resistances Bus Fixed Shunt Grounding DC Resistances Bus Fixed Shunt DC Resistances Transformer Core Number Transformer Kfactor Most real data need to be manually entered into the GIC input file!

Questions or Comments?