Haiwell PLC Modules Introduce

Slides:



Advertisements
Similar presentations
Supervisory Control & Data Acquisition DAQ Networking.
Advertisements

ZXM10 EISU Training.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Setup Guide - Profibus communication AC141x with Step 7 V5.5 English
Show Controller——DMX Module 48 Channel——SB-DN-48DMX 512 Channel——SB-DN-512DMX Configuration of Show Control ler ( DMX Module ) 240 Channel——SB-DN-240DMX.
Advantages of using R.PC.R Software Now that you know some of the advantage let’s take a look at the software … Reliable and Comprehensive Reporting Recording.
SCADA and Telemetry Presented By:.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Specview 32 Release 2.5 Enhancements
Analog Discovery Arbitrary Function Generator for Windows 7 by Mr
Turbine Crane CRANES TURBINE NEA39. Turbine Crane PLANT STATUS! PV Daily Status Report.
CHAPTER 2: TYPES OF CONTROLLER
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
Getting to Know Your Computer Your File System Applications What’s running on your machine Its own devices Networking.
LIGO-G9900XX-00-M LIGO II1 Why are we here and what are we trying to accomplish? The existing system of cross connects based on terminal blocks and discrete.
SEMINAR ON P.L.C. SUBMITTED BY HRIDAY MUKHERJEE AMIT DEBNATH SOMNATH SHIL
Modem. Introduction: A modem [Modulator -Demodulator] is a device. Data communication means transmitting digital information form one computer to other.
SIX-NET Documentation SIX-NET Documentation (SCL) (SCL)
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
LAN Connections.
Instructor Materials Chapter 8 Configuring Cisco Devices
CMV-NET Chigo VRF Network Centralized Control System
Configure the intercom IP
6 CHAPTER PLC Programming. 6 CHAPTER PLC Programming.
Gateway HDL-MBUS01IP.431.
ILife App.
Advanced Configuration
Monitoring systems COMET types MS55 & MS6
Lab 1: Using NIOS II processor for code execution on FPGA
Chapter 5.
I/O SYSTEMS MANAGEMENT Krishna Kumar Ahirwar ( )
Chapter 2: Configure a Network Operating System
MODEMS (Converts analog signals to digital and vice-versa)
Always Connected introduces Tigo SMART 3.0 This guide is interactive!
SCADA for Remote Industrial Plant
Microcontroller Applications
Wireless 4 Buttons Touch Panel
DT80 range Modbus capability
How SCADA Systems Work?.
Wireless 3 Buttons Touch Panel
Chapter 10 © 2011, The McGraw-Hill Companies, Inc.
Crouzet touch Quick start.
Chapter 6: Network Layer
IRQ, DMA and I/O Ports - Introduction -
Zigbee Networks Using Xbee Modules
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Setup Of 4050 EIP To Control LOGIX PLC
Identifying SLC 500™ System Components
Siemens Step 7 Project with Controllere in 7 Steps: Step 1
Programmable Logic Controllers (PLCs) An Overview.
IP-AK2 Access Control Solution
HMI CP Range General Presentation.
Introduction to Microprocessors and Microcontrollers
Chapter 2: Configure a Network Operating System
MCS-Connect Change all frames to windows
Haiwell PLC Modules Introduce
PAVIRO - Introduction Security Systems
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Windows Tutorial 9 Maintaining Hardware and Software
Lecture 8: Modems (Converts analog signals to digital and vice-versa) 1nd semester By: Adal ALashban.
How to install HP printer using IP address? How to install HP printer using IP address? Call
Total HVAC Control from anywhere Easy control that can save a fortune
Switching & Controlling LoB
Introduction to Arduinos
724 Temperature Calibrator
GasGard 100 Control System
How to install and manage exchange server 2010 OP Saklani.
Presentation transcript:

Haiwell PLC Modules Introduce

Modules Ethernet+RS485Modules RS485 Modules Extension Modules 5 Types Expansion Modules Digital Modules Analog Modules Temperature & Humidity Modules Functional Modules Communication Modules

Expansion Modules connection modes Haiwell Modules-2 kinds of connection modes Modules can be directly hung behind the host PLC to achieve expansion, with the parallel port connection. Single host PLC can be expanded up to 7 modules in maximum (of which up to 3 communication modules)

Expansion Modules connection modes As remote modules, Haiwell modules exchange data with host PLC by 485 network communication mode to achieve expansion, with the communication line connection. One communication port can be expanded with multiple modules

DT-Digital Temperature & Humidity Modules Haiwell digital temperature & humidity modules have 2 kinds of models: H04DT、H32DT,they can be used as expansion modules for any host PLC. The H32DT temperature expansion module with RS485 communication port, can be used as a remote IO module; H04DT can measure temperature and humidity.

H04DT-Temperature & Humidity Module H04DT module supports 4-channel DS18B20 temperature sensor、RW1820 temperature sensor、DS1990 sensor and SHT1X/SHT7X temperature-humidity sensor, with the function of measuring temperature and humidity simultaneously. It can be used to accurately measure the temperature and humidity within the range of 200 meters, and the collecting values of temperature and humidity are without error. Moroever, H04DT can be used as an expansion module for any host PLC, with conversion accuracy of 9-12 bits. The following we will introduce the expansion mode that expansion modulescan be hung directly behind the host PLC to achieve expansion, for example, one host PLC can be expanded with one H04DT module.

H04DT-Temperature & Humidity Module Terminal wiring diagram Product wiring diagram

H04DT Module hardware configuration Select the “PLC hardware configuration” to add the module Select the “PLC hardware configuration” to add the module Right-click in the blank to add the required modules

H04DT Module hardware configuration select the signal type of you want to configure choose the conversion accuracy zero correction

For example, we connect channel 1 of H04DT to a DS18B20 sensor and channel 3 to a SHT10 sensor. After downloading the configuration of H04DT into the PLC, from the monitoring program we can see that the channels of AI0 and AI2 have real-time display values. The temperature datas are returned by the two sensors. You can directly use the two registers of AI0 and AI2. Use the component status table to view Use the monitoring window to view

We have access to a temperature and humidity sensor SHT10, but we only read the temperature in the AI2, then how to read the humidity measured by SHT10? For this special case, we need to use the FROM instruction to read the humidity value which is inside the register of SHT10. Let's take a brief look at the FROM instruction

EN - Enable:FROM will be executed when getting power, usually communication instructions should always keep the state of power supply. slot - Module position number:The position number of module located behind the PLC. CR - CR register be read:The register address which we want to read. N - Number of CR be read:The register number which we want to read ENO - Enable output:Instruction execution condition. OUT- Return start componet:The read back data stored into the register..

Use FROM to read the humidity value of the SHT10 sensor H04DT is the first module behind the host plc, so fill 1 in the slot According to the parameter information of module, the CR number of the humidity register of channel 3 is 22 Read the humidity value and store it in V100, humidity value: 30% Read 1 register The above demo is the usage method that expansion module H04DT connects with host PLC by the parallel line.

H32DT-Temperature Module The digital temperature module of H32DT which supports 32-channel DS18B20 temperature sensor, RW1820 temperature sensor, DS1990 sensor is built-in RS485 communication port which can support remote function and be used as a remote IO module; It is widely used in coal mining, tunnels, refrigeration, libraries, archives and other multi-point temperature measurement environment and other environmental testing system. For a better understanding about how to set the parameters when the modules are used as remote IO, the following we will take one H32DT as the remote IO module, to show the expansion mode and configuration parameters of remote modules.

H32DT-Temperature Module Terminal wiring diagram Product wiring diagram

Module hardware configuration First, connect the expansion module H32DT to the PC by 485 cable, then open the programming software and find the remote module online option in the menu, finally make a remote module online, the default communication parameter for the module is 19200 N 8 2. select the tool menu - remote module, or directly click on the shortcut icon of remote module button into the remote module interface

Remote module interface Ethernet module cloud function Module online Regular functions Support the setting parameter of remote module import and export Restore defaults and help menu

Remote module interface Click the “online” button Pop-up online window Set the communication parameters, the module default 19200 N 8 2 RTU then click the “online” button to find the module

After the success of online, we can see the module parameter values which we can read and modify. Communication Parameter Area Moudles Name Data Monitoring Area

Module station number setting Set the remote module station number (also called station address, communication address) via the 4-bit DIP switch on the hardware. Legal station number is 1 ~ 254 (0 is broadcast address). 4-bit DIP switch can be used to express the decimal number 1 to 15 (binary number from 0001 to 1111), through the DIP switch to modify the station number as follow: If the hard address expressed by the 4-bit DIP switch is not available or the module does not have a DIP switch, you can set the station number via the programming software. After online with the module, you can modify the module station number in "Address" of " Communication parameter " column, then click " Parameter download" to change the module station number.

then click the parameter download You can modify the communication parameters in the communication parameter column. For example, if you want to change the station address to 8, then directly enter the address 8 Pop-up “download the parameter finished” indicates that parameters have been modified successfully.

Sensors configuration export When the H32DT module is actually access with the sensors, we can see the serial number of actual access sensors. After using more sensors in the field and the positions have been fixed, you can save the configuration table by export, so that the positions of sensors and the registers are kept corresponding to facilitate on-site maintenance.

Click the “Export” button to pop up the export window Select the path to save and click “Save”

Sensor configuration import If you need to import the configuration table into the temperature module, click the “Import” button, find the configuration file to be imported, then click “Open”.

Wireless Communication Modules PC2ZB H01ZB

H01ZB Module & PC2ZB Module Product introduction PC2ZB:It is a type of wireless communication expansion module that used on PC side. Through this PC2ZB, HaiwellHappy 、HMI、intelligent gateway and other host computers can achieve online and read-write in wireless mode with the host PLC which is extended with H01ZB. H01ZB: It is a type of wireless communication expansion module that used between host PLCS. The host PLC that extends the module can use the MODR / MODW instruction to implement wireless read- write communication. Product features The first five digit 1~5 of DIP switch are used for setting network ID. The sixth digit of DIP switch is coordinator/router switch, when toggling ON, this module is coordinator, the other modules in the same network can only be OFF as router. It can be easily set up networking by setting different network ID. Automatic relay can be done without manual intervention.

H02PW-Programmable Power Module Haiwell H02PW Module which can be used as an expansion module for any host PLC, has 2-channel power supply output, supporting the output of constant current、constant voltage and PWM, supporting the measurement of loop current and voltage. H02PW programmable power module can be widely used in coil products detection.

First, connect the expansion module H02PW to the PC, then open the programming software and find the remote module online option in the menu, finally make the H02PW module online, enter the remote module interface. setting parameters of channel duty cycle Channel 2: voltage\current setting values Channel 1: voltage\current setting values Channel 2: voltage\current actual value Channel 1: voltage\current actual value

Haiwell better future with you