Sectos NXB and NXBD.

Slides:



Advertisements
Similar presentations
L.T Circuit Breakers.
Advertisements

Medium-Voltage Switchgear - Then and Now -
Variable Frequency Drives Bypass Options
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
STAND ALONE CONTROL FOR TERMINALS
M iniature circuit breakers to UL 489
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
FIPTMV Medium Voltage Technology
Introduction To Programmable Logic Controllers
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
SF6 load-break switch-disconnector
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
Sales Training Outline 2006 Klaus Tum Product Manager NEW Circuit Breakers 35 Royal Road Flemington, NJ
MV SF6 circuit-breakers for secondary distribution
Multi-function apparatus for secondary distribution
Dry type transformers Zaragoza Accessories and options
WFR-12~24 Product presentation
1. Presentation Overview  Solar Industry Overview  Intro into Solar Photovoltaics  Types of PV Systems  Solar Product Offering –Solar Combiner Boxes.
Wiring Accessories Energy & Environment.
Chapter 3 Manual Starters.
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
Industrial Machine Control
Pole Mounted Switch Disconnector NPS
HASMUKH GOSWAMI COLLEGE OF ENGINEERING HASMUKH GOSWAMI COLLEGE OF ENGINEERING BRANCH :- ELECTRONICS & COMMUNICATION.
Frankfurt (Germany), 6-9 June 2011 V Ramesh – India – Session 1: Network components – 1096 Integrated Switching Devices (ISD) V.RAMESH ABB Limited, Nashik,
GEARMOTORS FOR INDUSTRIAL SECTIONAL DOORS GEARMOTORS FOR INDUSTRIAL SECTIONAL DOORS.
All rights reserved Gas-insulated Switchgear (GIS)
Your Connectivity Partner. Locations Main Office: High Tech Products Lallio, Italy USA Office: HTP Connectivity Parsippany, NJ.
Description of various components/sub-assemblies.
Medium Voltage Outdoor Apparatus Portfolio
SF6 load break fault make switches for overhead networks
Cooper Bussmann Overview. Overview 2 Electrical Electronics Transportation World leader in Electrical fuse technology Solid growth in emerging markets.
Basic study of a switch Unit 3.Lesson 3. A switch Purpose A switch is a mechanical device used to connect and disconnect a circuit at will Parts seen.
Disconnector Switches and Earth Switches
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
VIVOTEK Surveillance Cabinet Solution
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
ELECTRICAL INSTRUMENTS ( service and utilization )
AUTOMATIC CIRCUIT RECLOSER
Circuit Breakers CBI and ETA product offerings. Breaker Technologies - Hydraulic-Magnetic Not effected by ambient temperatures Possible to obtain any.
Push Button Station and Relay
VMCL ELECTRONIC DIVISION.
Sub Station.
EPOX PRODUCTS.
3AH5 Vacuum Circuit-Breaker For Standard Applications
SCADA for Remote Industrial Plant
UNIT 5 ELECTRICITY AND MAGNETISM
Asahi/America Electric Actuators Series 94.
SWITCHES W. C. “Buster” Hounshell Spring 2002.
Name, department/event, date
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Oil-tight MV fuse CEF-OT with TPC bushings
Engineering Project Cable Management.
ELECTRICAL POWER-II Electrical engineering sixth semester
Dave Mawdsley, DACS Member, Linux SIG January 16, 2013
Asahi/America Electric Actuators Series 94.
K1 Schematic Analysis and Pictorial Diagram
Utilizing the ring operation mode of MV distribution feeders
All rights reserved Gas-insulated Switchgear (GIS)
PQube® 3 Standard Pre-Wired Packages for quick and easy installation
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
FIRE ALARM DRILL 26 © Ted Smith 2017.
Presentation transcript:

Sectos NXB and NXBD

Sectos NXB Pole Mounted SF6 Insulated Switch 3-position (on-off-earth) or 2-position (on-off) Silicon rubber insulators, CD 620 mm 12-24 kV, 630 A, 20 kA 3 s Making capacity 50 /31,5 kA - main switch 3 /10 times - earthing switch 3/5 times Optional items - integrated motor - auxiliary contacts - current sensors Type Sectos NXB_

Sectos NXB 3-position (on-off-earth) or 2-position (on-off) Epoxy resin insulators, CD 500 mm 12-24 kV, 630 A, 20 kA3 s Making capacity 50/31.5 kA - main switch 3/10 times - earthing switch 3/ 5 times Optional items - integrated motor - auxiliary contacts - current sensors Type Sectos NXB_

Sectos NXB Over voltage protection arrester MWK Current sensor KOKU Lever for emergency operation by hook stick Bird caps together with covered jumpers (BLX)

Sectos NXB Climate independent Control plug-in cable Integrated motor mechanism for remote control Position indicator according to IEC 60129 standard

Sectos NXB Direct cable connection with Series 400 cable connectors Earth cable

Sectos NXBD 3-way switch Sectos NXBD, built of two NXB in the same housing Ideal for line branching Two switched ways + one tapped way Equal ratings with NXB Two motor-up mechanisms with a common control box Option for integrated CT:s

Sectos NXBD 3-way switch Sectos NXBD, Main circuit diagram

Sectos NXBD 3-way switch Sectos NXBD, branching from one cable to two overhead lines

Sectos NXBD, branching from cable to cable and overhead Sectos NXBD 3-way switch Sectos NXBD, branching from cable to cable and overhead

Sectos NXBD 3-way switch SECTOS NXBD24. Double switch-disconnector 2pcs. All 4 motors remote controlled from same DTU131 operating box using REC523 type of RTU Before

Installation of two pcs of NXB and one NXBD Sectos NXB and NXBD Installation of two pcs of NXB and one NXBD

Sectos NXB and NXBD Installation of two pcs of NXB and one NXBD One DTU 131 enclosure used for operating four disconnectors

Sectos NXB and NXBD Installation Sectos is complete, fully tested at the factory and ready to installation. It is compact and light weight making the installation easier and faster than ever before. All necessary accessories for installation and use are available from the well proven NPS product-line.

Sectos NXB and NXBD Motor operation of Sectos DTU-enclosure: REC523-unit (Digital and analog inputs from sensors and measuring transformers) communication unit heater 24 VDC battery 1…4 pcs contactor logic with local control push buttons and MCBs optional motor up operating device UEMC40K8 on Sectos NXB Distribution Terminal Unit (DTU) DTU 131 and 135

Sectos NXB and NXBD Motor operation of Sectos DTU-enclosure : RTU211-unit (Digital inputs only, no measuring) communication unit heater 24 VDC battery 1…4 pcs contactor logic with local control push buttons and MCBs optional motor up operating device UEMC40K8 on Sectos NXB Distribution Terminal Unit (DTU) DTU 131 and 135

Sectos Sectos switch disconnector NXB technology NXA technology NXB 12…24 kV (BIL max. 125 kV) 24…36 kV (BIL max. 170 kV) NXB technology NXA technology NXB NXBD NXA Motor up Manual Motor up Motor down Manual Conical epoxy bushings Outdoor epoxy bushings Conical epoxy bushings Direct cable Silicon insulators for overhead line Overhead line Direct cable Silicon insulators for overhead line