ABB i-bus® EIB / KNX Thermoelectric Valve Drive TSA/K , TSA/K 24

Slides:



Advertisements
Similar presentations
Electrical Sensing Devices. What are the basic functions of electrical control? u safety u convenience u comfort.
Advertisements

Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Fan Coil Unit Product Line-up. FCU Home Application Show.
STAND ALONE CONTROL FOR TERMINALS
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
BERKER KNX TOUCH SENSORS
11 Heating System Operation and Diagnosis.
Energy Efficiency with ABB i-bus® KNX
Danfoss thermal actuatorsDanfoss thermal actuators (Link) Heimeier thermal actuatorsHeimeier thermal actuators (Link) Dimming actuator for Sleeping Rooms.
EGD ELECTRICAL ELECTRICAL SYMBOLS.
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
2013 NATEF Task Area A-7 Heating, Ventilation, and A/C A. A/C System Diagnosis & Repair B. Refrigeration System Component D & R C. Heating, Ventilation.
ABB Signal Easy solutions
BUILDING MANAGEMENT SYSTEM
Temperature Control Loop
2010.
Applied Systems News FWEC*A Rudolf BARET HEISSIG.
1 HVACR317 - Refrigeration Operating Controls 1 Thermostats Operating Controls 1 Thermostats.
1 HVACR317 – Core for Refrigeration Operating Controls 1 Thermostats Operating Controls 1 Thermostats.
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
the compact air control solution
Electromechanical Relays Mechatronics ECE 5320 Assignment #1 Paul Smart.
E3 HVACR Controls and Devices
ABB i-bus® EIB Shutter Actuators
New Electric Actuators EA Type
ABB i-bus® KNX Fan Coil Actuator FCA/S
Fan Coil Actuator FCA/S 1.x.x.2
ABB STOTZ-KONTAKT GmbH Intrusion Detection Technology SSM/x SafeKey Switching Module 2011 | Slide 1.
Fan Coil Controller FC/S 1.1
G. Schlag / STO-GM / Novembre 2012
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX i-bus® Tool
Room Controller RC/A 8.1 Room Controller economic flexible modular.
Sensor presentation.
FCU Controller M/FCU
DALI-Gateway DG/S 8.1.
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
Text آشنایی بیشتر با کنترلر هوشمند زیمنس
ABB i-bus® KNX Valve Drive Actuator VAA/A
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
ABB i-bus® KNX Fan Coil-Actuator FCA/S 1.1M
ABB i-bus® KNX Room Solutions
Blower-/Fan Coil-Actuator
Universal Interface, 4-fold, FM, US/U 4.2
E3 HVACR Controls and Devices
ABB i-bus® EIB Electronic Switch Actuator, 4-fold
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
13.3 Using Heat.
Jörn Kruse / STO-G / Mai 2009 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX The „smaller“ Room Controller RC/A 4.2 © STO/G - Slide 1.
ABB i-bus® EIB / KNX Elektromotor Valve Drive ST/K 1.1
Electrical actuation systems
HBLT-wire Product Introduction September 21, 2018.
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
ABB i-bus® EIB / KNX USB Interface
EIB Power Supply, 160 mA SV/S
Electronic relay ER/U 1.1 contact TU/W 1.1 US/U 4.1 ER/U 1.1
Commissioning Power Supply NTI/Z
Universal Interface, 12-fold, FM US/U 12.2
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
Universal Dim Actuator UD/S
Total HVAC Control from anywhere Easy control that can save a fortune
ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1
Hardware integration and interfaces
Detailed information FOR INTERNAL USE ONLY! CUBE20.
Presentation transcript:

ABB i-bus® EIB / KNX Thermoelectric Valve Drive TSA/K 230. 1, TSA/K 24

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Content Application Device and Accessory Function Data Mounting / Demounting Control Ordering Details

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Application Opens and closes valves in HVAC systems, e.g.: Radiators Cooling Ceilings Floor Heatings Fan-Coil Units

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Device and Accessory Thermoelectric Valve Drive TSA/K - TSA/K 230.1 (230 V) - TSA/K 24.1 (24 V) Valve Adapter VA/Z for all common valves - VA/Z 10.1 - VA/Z 50.1 - VA/Z 78.1 - VA/Z 80.1

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Function The resistor-heated elastic element ① is heated and expands by applying the operating power The integrated ram ② performs the adjustment travel The adjustment travel (approx. 4 mm) is transformed to the valve lifter ③ The valve will be opened or closed. The function display ④ shows valve status ① ② ③ ④

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Data I Two versions: - TSA/K 230.1 (230 V AC) - TSA/K 24.1 (24 V AC/DC) Normally Closed (NC) Improved over voltage protection (2.5 KV) 360° mounting 100 % water protection (IP 54) Mounting and demounting without tools Pluggable connection cable (1 m) Demounting protection NEW! NEW!

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Data II First-Open function Enables heating operation even when the electric wiring is not yet complete ① Delivery state normally open ② First-Open function will be unlocked after applying the operating voltage (> 6 min.) ③ The Valve Drive is fully operable ① ABB ② ABB ③ ABB

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Data III Adjustment-control To control adjustment TSA/K VA/Z ① With the proper Valve Adapter the function display is approx. 0.5 mm extended (after First-Open function is unlocked) ② ③ False Valve Adapter Important: Chose Valve Adapter properly! ① ② ③

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Mounting ① Screw Valve Adapter VA/Z on valve base ② Snap-on TSA/K on Valve Adapter ③ Plug connection cable into TSA/K and remove demounting clip ① ② ③

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Demounting ① Remove connection cable ② Press demounting clip ③ Remove Valve Drive TSA/K ① ① ② ③

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Control With Room Thermostat and Electronic Switch Actuator ES/S ES/S Max. 3 TSA/K 24 V AC/DC 230 V AC RT BA/U

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Control With Room Thermostat, Universal Interface US/U and Electronic Relay ER/U US/U ER/U Max. 3 TSA/K 24 V AC/DC… 230 V AC RT BA/U

Thermoelectric Valve Drive TSA/K 230.1 / 24.1 Ordering Details Type Designation Order-No. TSA/K 230.1 Thermoelectric Valve Drive, 230 V 2CDG 120 007 R0011 TSA/K 24.1 Thermoelectric Valve Drive, 24 V 2CDG 120 008 R0011 Accessory VA/Z 10.1 Valve Adapter (M 30 x 1.5) for KaMo, Dumser, Chronatherm, Vescal 2CDG 120 009 R0011 VA/Z 50.1 Valve Adapter (M 30 x 1.5) for Reich Honeywell, Cazzaniga, Landis & Gyr., MNG 2CDG 120 010 R0011 VA/Z 78.1 Valve Adapter (Flange) for Danfoss RA 2CDG 120 011 R0011 VA/Z 80.1 Valve Adapter (M 30 x 1.5) for Herb, Heimeier, Onda, Schlösser (from 93), Oventrop 2CDG 120 012 R0011