Anatomy of Contemporary CTO Guidewires and Selection Criteria

Slides:



Advertisements
Similar presentations
The language of CTO interventions – what it all means
Advertisements

Basic principles of the procedure Frijo Jose A
Large Taper Files. Engine-driven files Hand-Using Large Taper Files.
Aortic dissection: current percutaneous options Advanced Angioplasty BSET Jan 2008.
Balloons and Wires Adam B. Greenbaum, MD Associate Director, Cardiac Cath Lab Henry Ford Heart and Vascular Institute No relationships to disclose in relation.
Subtitle Text Here Zylon Medical Devices Smaller Is Better Supported by NIH SBIR PHASE II Grant # 5 R44 H
W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Not only a peripheral stent available in Renal sizes...
W e m a k e i d e a s c o m e a l i v e For internal use only Covering all your needs for Fem-Pop Interventions.
Guide wires in CTO PCI Dr.C.G.Bahuleyan, MD,DM, FRCP(UK), FSCAI
2 Introduction Drug-eluting stents have defined a new era in the successful treatment of coronary artery disease However, like any therapy, DES results.
Electrophysiology Diagnostic Catheter Family
Featuring CTO Complex-PCI by Trans-radial Approach CTO Case review 5 French TRI CTO of right coronary artery -5 F Launcher guiding Catheter (right Judkins.
Retrograde approach for the Recanalizaiton of Coronary CTO: Preliminary Experience of Single Centre Lei Ge, Juying Qian, Xuebo Liu, Qin Qing, Junbo Ge.
The First Affiliated Hospital of Harbin Medical University
Using a deflectable tipped Catheter to treat previously inaccessible lesions Helen Routledge Interventional Fellow Institut Cardiovasculaire Paris Sud.
Dedicated Bifurcation Stent Technology: Implications for Everyday Practice Jens Flensted Lassen MD, PH.D., FESC The Heart Centre, Rigshospitalet University.
Chronic Total Occlusions
Basic PCI Equipment: Guide Catheters, Guide Wires and Balloons
Date of download: 6/2/2016 Copyright © The American College of Cardiology. All rights reserved. From: Retrograde Techniques and the Impact of Operator.
SCAI Interventional Cardiology Fall Fellows Course 2012 Selection and Use of Basic Equipment : Guiding Catheters, Wires and Balloons John S. Douglas Jr,
The Effect of FFR Wire Design on Function
Antegrade Femoral Artery Access
Michael J. Cowley, MD, MSCAI
COMET A truly innovative system to ease FFR
The Endocross Enabler-P: First in-Human Results
A new technique of IVUS guided CTO PCI
G. Capretti, M. Carlino, A. Colombo, L. Azzalini
Product Specifications
Management of Aortic and Aortoiliac Stenoses and Occlusions
CAROTID STENTING: Step-by-Step Technique
Transradial Intervention: Complex Case Review Yes, They Can Be Done!
Intraluminal Coronary Reentry Bridgepoint Medical CTO Crossing Systems
Direct Flow Medical Experience with a Conformable, Repositionable, Retrievable, Percutaneous Aortic Valve Reginald Low MD University of California,Davis.
Wire Externalization, Snaring and Removal
Abbott Vascular Bifurcation Program
Showa University Fujigaoka Hospital
Dr. Bradley Strauss CIHR Team in Vascular Occlusive Disease
Advanced CTO Techniques:
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Masahiko Ochiai MD, FACC, FESC, FSCAI
The Spectrum of Guidewires Available to Recanalize CTO and How to Choose the Wire/Device Hybrid CTO PCI 2011 Craig A. Thompson, M.D., MMSc. Director, Invasive.
MCV Campus Ginger Edwards.
Prairie Cardiovascular Consultants
The Spectrum of Guide Wires Available to Recanalize CTOs:
Crossing SFA-Popliteal Artery CTO’s
A Fixed Guidewire Stent Delivery System
CTO Perspectives: When not to Start, and When to Stop and Try Again
Craig A. Thompson, M.D., MMSc.
DES Bioabsorbable and DCB Technologies
Crossing CTOs via Planned Dissection: LaST (Limited Antegrade Subintimal Tracking): from knuckle wire to Bridgepoint Craig A. Thompson, M.D., MMSc. Director,
Guidewires Market Outlook
CTO Wires Trends in Guidewire Selection in Refractory Cases
Subintimal Tracking and Reentry for CTO STAR Method
Crossing CTOs via Planned Dissection: LaST (Limited Antegrade Subintimal Tracking): from knuckle wire to Bridgepoint Craig A. Thompson, M.D., MMSc. Director,
A Step-by-Step Description of the Retrograde
The Hybrid approach to CTO PCI
Essesntials for CTO Recanalization
Newer methods to Facilitate the Retrograde Approach
Fig. 2. Revascularization for CTO in RCA
The FDA’s View on CTO-PCI Devices
Shigeru SAITO, MD, FACC Kamakura & Sapporo, JAPAN
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Guidewires Market
CRT 2012 Primer for Endovascular Interventions
Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design 
Area of a rectangle Tuesday, 05 February 2019 Definition:
Tatsuya Nakama, Yoshisato Shibata, Kenji Ogata, Nehiro Kuriyama 
Essentials of Good Pain Care: A Team-Based Approach
Presentation transcript:

Anatomy of Contemporary CTO Guidewires and Selection Criteria Patrick L. Whitlow, MD Director, Interventional Cardiology Cleveland Clinic

Disclosure of Financial Interests Research support : Abbott Vascular, Edwards LifeSciences Consultant: ICON, Frantz Medical Stockholder: Medtronics, Inc.

HI-TORQUE® and ASAHI® Guide Wires HI-TORQUE® BMW Guide Wires ASAHI® Guide Wires

ASAHI TruTorq™ Technology SINGLE-JOINT Stainless Steel Platinum JOINT-LESS Platinum TruTorq™ Technology incorporates a proprietary method of fusing the stainless steel to the platinum spring coils for a joint-less transition.

Fielder FC  Unit ; (mm) Urethan + Hydrophilic Polymer Coat ; 200 0.014Inch PTFE Coat It’s difficult to have tactile feelings from a polymer jacket wire such as Fiedler FC! Ochiai

HI-TORQUE WHISPER® MS & WHISPER® ES Polymer cover with transitionless core designed for deliverability and distal access in tortuous anatomy

HI-TORQUE PILOT® 50 Full Polymer cover with Hydrocoat hydrophilic coating for designed for lesion access Tip coils provide soft, shapeable tip and tactile feedback Marker Band Modified RESPONSEASE™ parabolic technology, designed for torque response and control while providing additional support1 .

Pilot Wires Plastic jacketed hydrophilic coating with progressively more aggressive tip strength Pilot 50 < 1 gm Pilot 150 3 gm Pilot 200 4.5 gm Available in 190( DOCable) or 300 cm lengths

Fielder FC 10

Shaping of the Wire Tip 1mm Fielder FC Fielder SION SION blue XT XT-R ULTIMATE blos3

Collateral Engagement Wire Use a Workhorse wire that has good tip-shape retention and reasonable support to track the support device into an angulated segment without a long leading edge into the collateral. Whisper MS, Runthrough, BMW, ProWater, Pilot 50, etc

Collateral Crossing Wires Usually choose a Polymer Jacket Wire with a soft but Shapeable ~1 gm Tip that is not tapered Fielder FC Pilot 50 ( RunThrough, Whisper) If extremely tortuous, consider a Fielder XT -- or Sion/ Sion Blue in the near future

Sion and Sion Blue Actone Actone Unit ; (mm) Hydrophilic Polymer Coat 0.014Inch Rope Actone PTFE Coat Silicon Coat Hydrophilic Polymer Coat 0.014Inch Rope Actone PTFE Coat

Lesion Crossing Wires Frequently chosen in an escalating strategy of soft/ safe tip first moving up to more powerful tips with more risk of dissection/ exit I. Fielder XT ( Whisper, Pilot 50, RunThrough) II. Pilot 200 Or CrossBoss III. Knuckle Wire (Fielder XT>> Pilot 200) IV. Confianza Pro 12 ( or some operators prefer 9 gm) ( Mir. Bros, Progress, ProVia)

ASAHI® MIRACLEBROS® Family – Straight Tip Guide Wires Characteristics: 11 cm of Radiopacity Joint-Less Technology Increasing Tip Loads 3g-12g Designed for challenging lesions Increasing Support with increased Tip Stiffness Hydrophobic Coating for tactile feedback and smooth device interaction

ASAHI CONFIANZA Pro® – Tapered Tip Guide Wires Tapered Tip Designed for Lesion Crossability ASAHI CONFIANZA PRO® 9 .009” Hydrophobic Coating 19.9 cm Hydrophilic Coating 1 mm Hydrophobic Coating Characteristics: Tip Load – 9.3g / 12.4g Tapered Tip – 0.009” 20 cm Radiopacitiy Joint-Less Technology Hybrid Coating ASAHI CONFIANZA PRO ® 12 .009” Hydrophobic Coating 19.9 cm Hydrophilic Coating 1 mm Hydrophobic Coating

HI-TORQUE PROGRESSTM Guide Wires Features INTERMEDIATE POLYMER COVER with HYDROPHILIC COATING : Designed to maximize wire maneuverability while in the lesion HYDROPHOBIC COATING: facilitates device movement over the proximal section of the wire TAPERED TIP: 0.012”, 0.0105”, 0.009”: 5mm EXPOSED TIP COILS: Uncoated for “true” tactile feel in the lesion CORE-TO-TIP STAINLESS STEEL: High tensile strength core material and transition less parabolic core eliminates prolapse points and minimizes kinking, delivering reliable steering and control Product Overview: The HI-TORQUE PROGRESS Family of Coronary Guide Wires is the next generation Chronically Stenosed Lesion (CSL) 0.014” wires. HT PROGRESS is a set of five guide wires, designed with a tapered tip and a variety of tip stiffness, for treatment of CSL’s. The wire features uncovered tip coils on the first 5mm of the tip, and a hydrophilic polymer sleeve that extends 29.5cm proximal to the uncovered tip. 3 cm radiopaque coils r

IMPORTANT CONCEPT: Penetration Power 40,80,120,140T,200T Tip Stiffness = 4.0g Tip Diameter 0.012” Tip Stiffness Area of GW Tip Note: drawing not to scale Area of GW Tip r Penetration Power: The wire HT PROGRESS 40, 80, 120, 140T and 200T, number is a calculation that defines the wires Penetration Power (tip stiffness in grams divided by the area of the guide wire tip), to assist physicians in choosing the most appropriate guide wire.  For example, if the HT PROGRESS 40 does not cross the lesion, the physician can choose HT PROGRESS 80, confidently knowing the wire has 2x the amount of Penetration Power as the HT PROGRESS 40. Why Penetration Power? – it’s the complete measurement of the guide wire (Tip Stiffness and the Area of the GW Tip) 20

HI-TORQUE PROGRESS Family of Guide Wires Photos 0.012” HT PROGRESSTM 40 / 80 / 120 0.009” & 0.0105” HT PROGRESS TM 140 / 200 Photos property of Abbott Vascular and on file

Penetration Power Calculations Guide Wire  Manufacturer Tip Stiffness (Load) (g) Tip Diameter Penetration Power (Tip Load/Area of Tip) (kg/in2) Fielder XT Asahi 1.2g 0.009” 19 CROSSWIRE Terumo 4.2g 0.014” 27 MiracleBros 3 3.9g 0.0125” 32 Persuader 3 Medtronic 5.1g 33 MiracleBros 4.5 4.4g 36 Shinobi Cordis 6.8g 44 Shinobi Plus 7.0g 45 CROSSWIRE NT 7.5g 49 Persuader 6 8.0g 52 MiracleBros 6 8.8g 72 Persuader 9 9.1g 0.011” 96 MiracleBros 12 13.0g 106 Confianza Pro 9 9.3g 146 Confianza Pro 12 12.4g 195 Tests performed by and data on file at Abbott Vascular

Externalization Wires Need a long wire with reasonable support and pushability, usually with a polymer coating or jacket Viperwire Advance 335 cm peripheral wire Pilot 200 300 cm Fielder FC 300 cm RotaWire Floppy 325 cm esp. with RotaGlide Solution