Estimating the Formation Rates of Heavy Metal Polyatomic Species in Plutonium Analyses with an HR-MC-ICP-MS with a Desolvating Nebulizer Alex Mitroshkov,

Slides:



Advertisements
Similar presentations
Calibration Techniques
Advertisements

The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
A TRACEABILITY TOOL FOR ELEMENTAL SOLUTION STANDARDS Gregory C. Turk NIST.
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Introduction The use of qNMR for purity measurement has been steadily growing in recent years. The assessment of the purity of calibration materials and.
AAS and FES (Ch 9, 7th e, WMDS)
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
World Health Organization
Detection of Copper in Wastewater Seth Holm Chem4101 December 2009.
Development of a TOF Version of the Desktop MiniSIMS Design & Applications A.J. Eccles, B. Cliff, C. Jones, N. Long, P. Vohralik Millbrook Instruments.
Uranium Medical Research Centre The Analysis of Uranium Isotopes Abundance and Ratios in the Civilian Population of Eastern Afghanistan.
1 FDA Survey of Lead in Pharmaceuticals John F. Kauffman, PhD R&D Team Leader CDER, Division of Pharmaceutical Analysis ACPS-CP Meeting July 22,2008.
BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS.
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
Printed by Monitoring Metals Hypersensitivity by Measuring Chromium, Cobalt and Molybdenum in Whole Blood Elzbieta (Ela) Bakowska,
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Analytical chemistry MLAB 243 Level 4 Lecture time: every WED 8 -10
* CORRESPONDING AUTHOR Use of High Resolution Mass Spectrometry (HRMS) to Solve Severe Issues Due to Isotopic Distribution in Regulated Bioanalysis Richard.
2007 Measurement Technology Workshop September 11, 2007 EPA Update on the Development of Alternative Reference Methods for Mercury and Testing Equipment.
A=193 Mass Chain evaluation: A summary IAEA-ICTP Workshop on Nuclear Structure and Decay Data: Theory and Evaluation, Trieste, Italy November
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
Calculating and Interpreting Error in AS Chemistry Click on the speaker icon on the right to hear the sound file You will need to be able to here the.
Effect of Sample Introduction on ICP-MS Detection of Nonmetal Analytes in a Simulated HPLC Matrix Adam E. Dill and Jon W. Carnahan Department of Chemistry.
00J ppt Rapid Extraction Methods for the Process Laboratory S. L. Maxwell, III V. D. Jones S. T. Nichols J. Satkowski M. A. Bernard Westinghouse.
Quality Assurance How do you know your results are correct? How confident are you?
Destructive Analyses Techniques for Safeguards Mary L. Adamic June 30, 2009 INL/CON
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Eliminating Molecular Interferences in ICP-MS for the Simplest Method Development Dr. Torsten Lindemann.
BAM IDepartment for Analytical Chemistry; Reference Materials Berlin, November 2006, 1 © H. Kipphardt, BAM I.1 Characterisation of High Purity Metals as.
MAPEP and the Role of the Cognizant Radiochemist in the Analytical Laboratory P.C. Temple Warwick, PhD RESL Office of Nuclear Energy U.S. Department of.
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
Control Charts and Trend Analysis for ISO 17025
University of Koblenz-Landau, Germany
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Indranil Sen, Wei Zou, Ryszard Gajek, Jianwen She*
Multi-Analyte LC-MS/MS Methods – Best Practice.
IMPACT SAMR Cover Sheet
An in-depth look at trace metallic impurity determination by ICP-OES
T. Higgs May 25, 2017 AESA Stack Testing Seminar
M. Fernández, E. Conde, A.I. Barrado Department of Technology
Lisa Edwards Sr. Program Manager LLW Forum April 13-14, 2016
Additional Operating Chemistry Considerations
Environmental Analytical Laboratory Sierra Nevada Research Institute
The XRF determination of sulphur in iron oxide.
Discussion and Conclusions
Andrew Kampfschulte & Rob Lievense September 16, 2015
GERDA meeting Dubna 27-29/06/2005
Making Physical Measurements
Sources of the PM10 aerosol in Flanders, Belgium, and re-evaluation of the contribution from wood burning Willy Maenhaut1,2, Reinhilde Vermeylen2, Magda.
Forecasting the Future using Diverse Social Media Sources
Visualizing Spatiotemporal Embeddings Demo
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Lexical: Words vs. Characters Syntactic and Stylistic
Deceptive News Prediction Clickbait Score Inference
Determining elemental mercury in soils by selective volatilization
The Analysis of Soils and Waters in Accordance with U. S
Quantifying Deception Propagation on Social Networks
ICP-MS ICP – Inductively Coupled Plasma MS – Mass Spectrometry
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Chapter 5 Quality Assurance and Calibration Methods
Why Use Them? By: Marcy Bolek – Alloway
Choice of Methods and Instruments
Nuclear Power Regulatory Overview
Environmental Laboratory Certification Program (ELCP)
Calculating Uncertainties Using Data from precision & bias experiments
Radiochemical Methods
M. Kezunovic (P.I.) S. S. Luo D. Ristanovic Texas A&M University
Practical Solutions Analysis of Variance
Presentation transcript:

Estimating the Formation Rates of Heavy Metal Polyatomic Species in Plutonium Analyses with an HR-MC-ICP-MS with a Desolvating Nebulizer Alex Mitroshkov, Khris Olsen, and May-Lin Thomas Overview When analyzing for low concentrations of Pu at the femtogram levels found in samples associated with environmental and nuclear processes, interferences in the analyzed solution from heavy metal (HM) interaction in the plasma may cause a false positive detection of Pu in the samples. Even the most modern, high resolution multicollector ICP-MS (HR-MC-ICP-MS) systems are not capable of separating Pu isotopes from polyatomic interferences (PIs), such as 208PbNOH, 207PbO2, and 204Pb35C at the 239Pu mass range. The formation of PIs were previously investigated using a quadroupole single detector ICP-MS1 and found the modern desolvating nebulizers (e.g. APEX and Aridus II) significantly reduce the formation of PIs, which could interfere with the Pu measurements compared to similar analysis using a wet plasma nebulizer system. In order to assess the impact of heavy metal most likely to affect our measurements for Pu we conducted a study using state-of-the-art instrumentation for Pu measurements. Objective The objective of this study is to evaluate the effects of the presence of 5d and 6p heavy metal on the measurement of plutonium isotopes in solution samples associated with environmental and nuclear processes. Specific tasks were to determine: The formation rates of PI from 12 heavy metals ranging from Hafnium to Bismuth on 239Pu, 240Pu, 241Pu, 242Pu, and 244Pu isotopes Determine the concentration of HMs in selected number of samples associated with actual nuclear processes. Method This study implements the use of a HR-MC-ICP-MS equipped, with a desolvating nebulizer. The specifics of the instrumentation and standards used are listed below. NU Plasma HR Multicollector ICP-MS (NU Instruments, United Kingdom) equipped with 11 Faraday cups and 3 ion counters as detectors, An Autosampler ASX-112FR and Desolvating Nebulizer Aridus II (both CETAC, Omaha, Nebraska) were used for sample introduction. The analytical conditions were optimized for Pu analyses. The Quick Wash attachment was used for quick washout of Pu and heavy metals from the system after every analytical run. CRM137 plutonium standard was used for system calibrations at a concentration of 2.52 ppt. 244Pu was used as a Instrument Dilution spiking solution at ~2.5 pg/mL. Heavy metal solutions of Pb, Bi, Hf, W, Hg, Au, Re, Pt, Ta, Os, Ir, and Tl at 200 ppb in 4% HCl (Ultra Scientific, Rhode Island) were uses for calibration Because of the low concentration of Pu in the samples, only ion counters were used with the three-cycle method for analyses of Pu and polyatomic species. There are three steps in Pu isotopic ratio measurement by the HR-MC-ICP-MS: Calibrate the instrument by measurements of background or “zeroes” Calibrate ion counter gains and mass bias factor (MBiasF) Conduct sample analysis Each sample is divided into two fractions; non-tracered and tracered (with 244Pu added). Each fraction was analyzed separately. The first sample analyzed in the analytical sequence was the non-tracered sample followed by the sample containing the 244Pu spike. Results The tables below present results for the formation rates of interfering species for the 12 heavy metal Conclusions Our experiments demonstrate: The implementation of desolvating nebulizer coupled with the HR-MC-ICP- MS significantly reduces the formation of heavy metals molecular ions of which could interfere with the measurements of plutonium isotopic ratios. Although some of the data derived from this research are close to previously reported data, especially for Pb[1, 2, 3], in general they are significantly lower (by 2 to 3 orders of magnitude) for most elements, especially for Hg. Concentrations of heavy metals measured in most samples from nuclear facilities were far from being able to significantly affect the Pu isotopic ratios measurements. The measured formation rates of PIs allow for estimating their contribution to the Pu results and potentially for making corrections on those results, once the heavy metal concentrations have been determined. Such an approach was used before[1]. The separation procedure used for the removal of heavy metals from the Pu fraction was effective at removing potential interferences which could effect the 239Pu and 240Pu values. However, there still could be effects on the measurement of 241Pu and 242Pu. NOTE: Print this poster file at 200% SCALE to result in a physical print measuring 72” wide x 42” tall. All type size notations shown above are based on the final printed size of the poster. • Contact Digital Duplicating (375-2969, http://digitalduplicating.pnl.gov) to order poster printing and finishing services for your completed poster design. • Remember to have your poster cleared for public display/distribution through the ERICA Information Release system (http://erica.pnl.gov). • Sidebar “About PNNL” box is considered optional, and can be removed if space is needed for technical content. PIs Caused by the Presence of Rhenium, Calculated for Selected Samples Comparison of Formation Rates In [1] the rate for PbO2 is given for 208Pb16O2, which is an obvious misprint. The ion 239 is produced by 207Pb16O2. In [2] the data are taken from the chart with multiple points.   239, Formation Rate 199Hg40Ar 191Ir16O3 207Pb16O2 This research 1.07E-08 8.90E-08 1.69E-09 Pointurier at al [1] 6.00E-06 3.10E-06 2.20E-08 Pointurier at al [2] 8.0E-06 - 7.0E-05 1.0E-07 -6.0E-06 1.0E-09 -5.0E-07 Magara et al [3] 3.00E-08  References: [1] Fabien Pointurier, Philippe Hemet, and Amelie Hubert. J. Anal. At. Spectrom., 2008, 23, 94-102. [2] Fabien Pointurier, Amelie Hubert, Anne-Laure Faure, Philippe Hemet, and Anne-Claire Pottin, J. Anal. At. Spectrom., 2011, 26, 1474-1480. [3] Masaaki Magara, S. Ichimura, M. Takahasi, S. Kurosawa, Y. Saito, F. Esaka, K. Yasuda, S. Sakurai, K. Watanabe, and S. Usuada. “Study on Interference of Polyatomic Ions in Isotope Ratio Measurement of Actinides by ICP-MS”, poster presented at Winter Conference on Plasma Spectrochemistry, Fort Lauderdale, Florida, January 5-10, 2004. NU Plasma HR Multicollector ICP-MS Reproduced with permission from NU Instruments, United Kingdom For more information, contact: Alexander Mitroshkov Pacific Northwest National Laboratory, P.O. Box 999, MS-IN K3-62, Richland, WA 99352 (509) 371-7113, alex.mitroshkov@pnnl.gov PNNL-SA-#####