The n_TOF Facility Today

Slides:



Advertisements
Similar presentations
Engineering Department EN Cooling and Ventilation issues 1 FUTURE EXPLOITATION OF THE EAST AREA EN-CV Michel OBRECHT.
Advertisements

Managed by UT-Battelle for the Department of Energy Review of NFMCC Studies 1 and 2: Target Support Facilities V.B. Graves Meeting on High Power Targets.
16.Feb.2005MC meeting, LBNL1 CERN infrastructure A.Fabich, CERN AB-ATB All information available at
Bapetco NORM Control Case Study IDENTIFY ASSESS CONTROL & RECOVERY.
Remote manipulations / diagnostics in radioactive areas and handling of radioactive material Workshop, Geneva, Switzerland 6 th May 2013 THE REPLACEMENT.
2013 NATEF Task Area A-7 Heating, Ventilation, and A/C A. A/C System Diagnosis & Repair B. Refrigeration System Component D & R C. Heating, Ventilation.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
REPORT VISIT SAPHYMO Dorothea Pfeiffer GIF++ Project Meeting
What need to be done to restart n_TOF (in 2007?) 4 Short description of the Facility 4 Old Target removal in the provisional Storage place (Service Gallery).
Radiation Test Facilities G. Spiezia. Engineering Department ENEN Radiation tests facilities  Radiation test in the accelerator sector  External facilities.
WP2 Superbeam Work Breakdown Structure Version 2 Chris Densham (after Marco Zito version 1 )
General RP guidelines for CENF CENF secondary beam study group H. Vincke07/05/
1 Safety Issues for the n-TOF target Thomas OTTO, Radiation Protection Group, SC-RP, CERN.
PSB dump: proposal of a new design EN – STI technical meeting on Booster dumps Friday 11 May 2012 BE Auditorium Prevessin Alba SARRIÓ MARTÍNEZ.
1 Target Station Design Dan Wilcox High Power Targets Group, Rutherford Appleton Laboratory EuroNu Annual Meeting 2012.
Towards a modified n_TOF Facility and Increased Radiation Safety Towards a modified n_TOF Facility and Increased Radiation Safety ATC/ABOC Days, 21 st.
N_TOF Technical Report INTC, CERN 21 May 2007 P. Cennini AB-ATB n_TOF Technical Coordinator Status of the old Target Removal Status of the old Target Removal.
Paolo Guglielmini - TS / CV LHCb Install Meeting - 20/04/2005 LHCb Install Meeting 20/04/05 TS / CV / Detector Cooling Installations.
Beam line Experiment area SC magnet Pion production target
Status of the new Target Design n_TOF Collaboration meeting, Paris 4-5 December 2006 P. Cennini AB-ATB Status of the old Target Removal Status of the old.
ISOLDE Activities for LS2 Richard Catherall EN-STI ISOLDE Technical Coordinator.
1 Target Station Design for Neutrino Superbeams Dan Wilcox High Power Targets Group, Rutherford Appleton Laboratory NBI 2012, CERN.
Workshop Chamonix XV27-January-2006 DivonneMassimiliano Ferro-Luzzi 1 State of LHCb for the Sector Test  Overview  Agreement  Status of –VELO –exit.
Beam loads & dump concepts T. Kramer, B. Goddard, M. Benedikt, Hel. Vincke.
First radiological estimates for the HIRADMAT project H. Vincke and N. Conan 1.
Radiation Protection aspects for SHIP Doris Forkel-Wirth, Stefan Roesler, Helmut Vincke, Heinz Vincke CERN Radiation Protection Group 1 st SHIP workshop,
7 November 2003 Status of CNGS NBI presented by K. Elsener 1 Status of CNGS Konrad Elsener CERN – Accelerators+Beams Division.
EAR2 Beam Line Report on the Status C. Weiss EAR2 Beam Line - Report on the Status1.
N_TOF commissioning INTC-P-249 Spokespersons: J.L.Tain, V.Vlachoudis Contactperson: V.Vlachoudis th Nov 2009 for the n_TOF collaboration.
Risk Analysis P. Cennini AB-ATB on behalf of the n_TOF Team  Procedure  Documents in preparation  Conclusions Second n_TOF External Panel Review, CERN,
Status Report by the n_TOF Technical Coordinator P. Cennini AB-ATB on behalf of the n_TOF Team  The n_TOF Facility  Where are we standing  Resume of.
YETS activities in n_TOF O. Aberle, S. Montesano (EN/STI)
NToF - Radiation Protection M. Brugger, P. Cennini, A. Ferrari, E. Lebbos, V. Vlachoudis CERN AB/ATB/EET.
EUROnu Costing Workshop May 2011 Beta-Beam Costing Exercise Elena Wildner, CERN 25/05/11 1 EUROnu Costing Workshop, CERN May 2011.
E. BERTHOUMIEUX ON BEHALF THE N_TOF COLLABORATION 2011 n_TOF facility status.
Horst Breuker Review Oct ELENA Safety and Radio Protection ELENA TDR : Chapter 6; Safety Files in preparation; Descriptive, Demonstrative (Risk.
Horst Breuker ADUC Jan Safety and Radio Protection, Consequences for the Experiments ELENA TDR : Chapter 6; Safety Files in preparation; Descriptive,
1 Cryogenic Design and the 4 He Evaporative Purifier David G. Haase, et al., North Carolina State University.
CERN Jan 2006 Specific safety Issues for 2006 compared to 2004 P. Cennini AB Safety Requirement in case the Installation activities are going on.
Characterization of the nTOF Radioactive Waste M. Brugger, P. Cennini, A. Ferrari, V. Vlachoudis CERN AB/ATB/EET.
BENE/EURISOL-DS Joint Meeting, CERN, SwitzerlandFebruary 22, Progress in the Liquid Mercury Multi-MW Target Design Studies Y. Kadi On behalf of.
LIEBE Target Design Review. Schedule This comment is no longer valid as the schedule has been postponed and the beam permit will be requested for Q
SECONDARY BEAM HANDLING AND INFRASTRUCTURE DESIGN STATUS BRUNO FERAL (CERN/EN) DIAMANTO SMARGIANAKI (CERN/EN) Project Leader: I.Efthymiopoulos (Cern/EN)
Update on the ESS monolith design Rikard Linander Monolith and Handling Group ESS Target Division TAC 10, Lund, Nov 5,
Safety - Lessons learnt from the design, commissioning and operation of the HIE-ISOLDE cryomodules Safety overview ESS 8 June 2016 AP.Bernardes/EN on behalf.
Task # 3 Task # kW Target Station Layout proposal Presented by L.Bruno CERN AB Experimental Areas, Targets and Secondary Beams Group.
The target handling concept of the pbar- separator at FAIR M. Helmecke, V. Gostishchev, R. Hettinger, K. Knie 6th High Power Targetry Workshop Oxford.
Status of the FAIR pbar target: Target handling study (M. Helmecke)
CV Activities for PSB-LIU POPS-B (new MPS for the PSB-LIU) B 245 PSB Demi water cooling plant Stefano Moccia, EN-CV Meeting 07/03/16.
Target Systems and Monolith Design Update Rikard Linander Group Leader Monolith and Handling April 2, 2014.
Long-Baseline Neutrino Facility LBNF News and brief overview of Beamline plans for the next few months Vaia Papadimitriou Beamline Technical Board Meeting.
The ESS Target Station Eric Pitcher Head of Target Division February 19, 2016.
V. Raginel, D. Kleiven, D. Wollmann CERN TE-MPE 2HiRadMat Technical Board - 30 March 2016.
New nTOF target: Design Issues
Demineralised water cooling system
News and Introduction from CERN June 15th, 2005
Heating and radiological
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
Proposal TDIS-TZM WP14 TDIS jaw validation testing
Components for the Machine-Interface Regions
David Montanari / Johan Bremer Jun 11, 2015 Rev. 1
News and brief overview of Beamline plans for the next few months
Radiation protection of Linac4 M. Silari Radiation Protection Group
Target and Horn status report
N-TOF EAR2 - Vertical beam design & construction - Irradiation facility proposal S. Girod EN-EA.
M. Calviani, A. Ferrari (EN/STI), P. Sala (INFN)
HiRadMat Test Facility
Overview of the TARGET Monolith Rough Vacuum
n_TOF Target #3 Production Readiness Review History of Target #3 options and baselining M. Calviani (EN-STI) n_TOF.
n_TOF Target #3 Baseline Design
Presentation transcript:

The n_TOF Facility Today Presented by P. Cennini n_TOF Technical Coordinator Facility overview Status of the main components of the Facility What has to be done to restart the Facility Operation Resources and budget n_TOF External Panel Review, CERN 14-15 June 2007

Main components of the Facility: The proton Line Present status: partially modified to host the MERIT Experiment What need to be done: re-installation of the beam line (resources and budget already allocated)

Main components of the Facility: The Target Area

Main components of the Facility: The Target Area protons Shaft Present status: inaccessible

Main components of the Facility: The Target Area marble neutrons Present status: inaccessible

Main components of the Facility: Air Ventilation in the Target Area History: After the 2001 run an additional shielding (B+C) has been put around the TOF tube to reduce the air activation. Following this actions the reduction expected by the FLUKA simulation (~ factor 10 for 7Be) has been achieved. A forced ventilation with filters and a system to monitor the release in the atmosphere has been requested by SC-RP. (see T. Otto presentation) Present status: Simulations done (see M. Brugger presentation) Design study done (J. Inigo-Golfin presentation) What need to be done: installation of the ventilation system with the monitoring of emissions in the atmosphere.

The Target Area What need to be done Remote Inspection of the pool through the shaft Depending on the results of this intervention two scenarios are envisaged: No signs of deep corrosion of the cooling circuit are detected. In this case the use of the existing cooling circuit could be envisaged and no actions are needed in this area. The inspections are revealing a deep corrosion of the pool or other problems. In this case the dismantling of the shielding around the target and in the first 20 m of the TOF tube is needed. Taking in account the ambient radioactivity and activation, this operation, requiring the direct handling of the shielding elements, should be carefully evaluated in terms of received doses.

Main components of the Facility: The Target Dimensions: 80  80  60 cm3 Pure Lead: 4 t Stainless steal supporting structure Present status: the target is in the Pool at the bottom of the shaft What need to be done: target replacement

The New Target Design Motivation & Design Options Why a new Target for n_TOF? (see T. Otto presentation) To avoid the water cooling contamination due to the direct contact between the lead and the cooling water. Two lines could be investigated: Cladded Target cooled with the existing cooling system Completely New design (tungsten, tantalum, air cooling, …) This approach eventually needs the dismantling of the shielding in then_TOF tunnel Considering: The activation of the shielding around the Target Area. The time needed to remove and reinstall the shielding (6 months). The “cost” of the received dose to do this operation (ALARA). The “Gained Experience” with the old lead Target The solution of a cladded target has been investigated first. The decision on the solution to be adopted strongly depends on the status of the irradiated target and the corrosion or contamination of the cooling circuit.

Design Options (investigated up to now) Cladded lead Target Neutron Flux: unchanged Target material: lead  Target cladding: aluminum alloy, stainless steal or zircalloy.  Target cooling: water (existing system)  Target dimension: ~ 100 liters, ~1.3 tons (cylindrical shape) Moderation: water / heavy water / borated water (exchangeable)  Useful n-beam diameter at the exit of the target: 40 cm  Orthogonal flight-path: foreseen 2.2 MeV  flash: optimized (10 %), by Moderator replacement. Target permanent Disposal: this aspect is integral part of the design.

The New Target: What need to be done Verification of the design options based on lead by making the visual inspection of the old target and the analysis of a sample to learn from the gained experience after 5 years of run (~ 6 x1019 protons on target). Finalization of the Design Study. Several solutions have been investigated in the framework of a new target similar to the old one water cooled by the existing system. (see Y. Kadi presentation) Conclude the Simulations: neutron flux, energy deposition, decommissioning . Write-up of the Safety File Activation and Dose-rate Simulations in view of the Permanent Disposal (in progress, see M. Brugger presentation)

Main components of the Facility: Target Handling Structure The Target must be moved from TT2-A to the Depository in the Service Gallery. This operation is done through the Shaft by using the Hoist System. A system using several video cameras is used for the remote control. Present status: Hoist system certified for the handling of loads up to 5 tons.

Main components of the Facility: Access to the Target Seen from the bottom Seen from the top Present status: shaft activated and eventually contaminated (bottom part).

Main components of the Facility: Target Handling

Target Handling Status Shielding in the Shaft: removed Direct measurement of the dose rate: done (~15 mSv/h max) Simulations of the Target activation and dose mapping: done (results in agreement with the measurement see M. Brugger presentation) Risk analysis for the Target removal (EDMS 771843): done Target removal Operating Procedure (EDMS 774982): done Target removal dose rate estimation (EDMS 774982): done “Un-sticking” test to verify the possibility to remove the target : done Exceptional procedure for the target recovery in case of jamming of the hoist system (EDMS 787079): proposal accepted by AB, under discussion with TS (see I. Ruehl presentation)

Target Handling What need to be done Envisaged Solutions: Use of the existing Hoist System implementing the required safety measures to recovery the target in case of jamming of the crane. Installation of a new Crane with improved reliability (double motorization). This solution has been already investigated. An offer in the framework of the “Contrat de maintenance Equipement de Levage et de Transport” is available. Expected budget: 350 kCHF Expected time for the delivery and installation: 5 months + 4 months for the market survey. (see I. Ruehl presentation) The main problem concerning the Target removal is the risk of jamming of the Hoist System during the operation Due to the target activation and contamination , the infrastructure and the procedure for the Target recovering in case of jamming of the Hoist System must be envisaged also for a system equipped with double motorization.

Main components of the Facility: Cooling Circuit Heat exchanger Pool Secondary loop water volume < 1 m3 Double pumps Remotely interchangeable Water level detection Filters Hydraulic circuit constituted of a heat exchanger and two independent loops: Primary loop connected to the PS demineralized water cooling circuit Secondary loop connected to the target “pool”. This loop is not pressurized. Continuous water demineralization and filtering Remote monitoring of all the parameters via SCADA. Safety measures Water level detection in the pool connected to the interlock chain Water retention measures implemented under the pool and the pumping station. Water detection in the retention vessel under the pool Radiation monitoring near the filtering system.

Main components of the Facility: Cooling Circuit- The Water Tank Target access Volume: ~140 l Material: Aluminum alloy Wall Thickness: 10 mm Water circulating at atmospheric pressure Water Retention Vessel Present status: inaccessible

Main components of the Facility: Cooling Circuit- The Window Useful diameter: 80 cm Material: Aluminum alloy Thickness: 1.6 mm Reinforced Monolithic construction Aluminum seal

Main components of the Facility: Cooling Circuit Draining pump Cooling Station Water Retention Vessel

Cooling Circuit History and Present Status The circuit was working without any problem during the four years runs. Normal maintenance performed during the shut-downs. Before the 2004 run, the filter was replaced (normal maintenance) During the 2004 run, the circuit was dried after removal of the water injecting compressed air during several days. This operation was intended to prepare the filling with heavy water (solution abandoned). After restarting an abnormal radioactivity in the filter was detected (see T. Otto presentation) In September 2005, the filtering elements have been replaced and a system for a quick exchange has been implemented (ODM 1120935). During this intervention the filter saturation was observed. Recently an inquiry to determine the contamination of the cooling circuit piping is in progress. Present Status: The secondary loop is empty since more than one year

Cooling Circuit What need to be done Concerning the specifications of the system the answer is YES, but The status of the Cooling basin and the connection piping to the Heat Exchanger must be evaluated after the removal of the old target. (see M. Brugger presentation) Two scenario are possible: Cleaning of the system by using standard procedures available at CERN (see J. Inigo-Golfin presentation) Replacement of the system. In this case the removal of the shielding around the target and in the tunnel must be envisaged. According with the information from TS, this solution is demanding a budget of ~ 100 kCHF, 6 months work and 1.5 FTEs. The expected received dose rate for this intervention is ~3 mSv Open question: could the existing cooling circuit be used for the cooling of the new target?

Main components of the Facility: The Vacuum Tube Four primary pumps are providing a vacuum < 1mbar Two pumps are in the primary area All the seals are metallic Valves Vacuum Pumps Experimental Area Safety: the Access Door to the Experimental Area is in the interlock chain. Accessing the area the Valves are automatically closed. Present Status: Vacuum ready to be restarted (normal maintenance)

Main components of the Facility: The Collimation The neutron beam size can be optimized for capture or fission measurement The collimation is done by two elements: Collimator 1 with fixed dimension at a distance of ~ 140 m from the target Collimator 2 with two possible openings located at ~ 5 m before the Experimental Area The nominal beam sizes are: Ø = 2.5 cm for capture, Ø = 8 cm for fission Present Status: Ready

Main components of the Facility: The Experimental Area EXA The EXA could be configured for two different measurement: Measurement of fission reactions by using various detectors (Ionization chambers FIC or PPAC) Measurement of capture reactions by using the Total Absorption Calorimeter or C6D6 scintillators. Set-up for fission measurement Set-up for capture measurement (TAC)

Experimental Area History and Status After the 2001, 2002 and 2003 runs, following a detailed simulation, the upgrade of the EXA has been done to minimize the risk of fire. Implemented measures: removal of the gas system for PPACS, removal of the DAQ modules, installation of a protective fire wall. Present Status: The Total Absorption Calorimeter is installed

Experimental Area Constraints The measurement of radioactive samples in the Experimental Area is subjected to the following restriction: (see T. Otto presentation) This rule is not presenting a serious limitation in case of capture measurement with the Total Absorption Calorimeter. For fission measurements, requiring the use of unsealed targets (PPAC and FICs), the detectors should be housed in a “class A-like” container. This infrastructure is provided by the laboratory installing the equipment. Radioactive targets with activities exceeding 1 LA must be housed in a container certified ISO2919. What need to be done: no actions expected for the Facility restart.

Main components of the Facility: The Temporary Target Depository The Temporary Target Depository, located at the end of the Service Gallery, is accessible with the existing Hoist System. The old target will be stored in this place waiting the agreement with PSI for the final disposal. (see T. Otto presentation) Present Status: Ready to receive the activated target What need to be done: no actions expected for the Facility restart.

Summary Actions needed for the restart of the Facility: Finalization of the design for the Ventilation System Removal of the old target Analysis of the samples taken on the old target (bulk, support) Visual inspection and sample analysis to define the level of contamination and corrosion of the pool and the cooling circuit pipes. Depending on the analysis results and inspections: Finalization of the new target design including the Cooling System (physics simulations, thermal and fatigue simulations, decommissioning) Preparation of the Safety File for the Facility Description. Operation resources after restarting: Technical coordination, engineering support to the institutions, vacuum maintenance, cooling system maintenance: 1 FTE/year Operation budget after restarting: 30 kCHF/year