Visual Aid.

Slides:



Advertisements
Similar presentations
How to import and edit video clips in Windows Movie Maker
Advertisements

Computer Basics Hit List of Items to Talk About ● What and when to use left, right, middle, double and triple click? What and when to use left, right,
Microsoft Office XP Microsoft Excel
Microsoft Excel. Click on “Start,” then “Microsoft Office Excel.”
 Use the Left and Right arrow keys or the Page Up and Page Down keys to move between the pages. You can also click on the pages to move forward.  To.
HIBBs is a program of the Global Health Informatics Partnership PETE HANKE & JESSICA COTE INDIANA UNIVERSITY – PURDUE UNIVERSITY – INDIANAPOLIS SCHOOL.
EPOCH 1000 File Management Data Logging and Reporting
Copyright ⓒ VATECH Global Co., Ltd. All rights reserved EasyStartGuide Please refer to the included User Manual for more detailed functions on EzDent-i.
>To add a component via Page Editor, go to the View tab and check the Designing checkbox to enter Designing mode. >Next, simply click the Component button.
Spreadsheet A spreadsheet is the computer equivalent of a paper ledger sheet. It consists of a grid made from columns and rows. It is an environment that.
InteractiveMedia’s Imagine Software Platform When user clicks on the Imagine desktop icon or installed app. This is the first thing the user will see full.
Wimba Presenters Guide North Dakota University System 2009.
GISMO/GEBndPlan Overview Geographic Information System Mapping Object.
Excel Screen Slide 1 Column Row Cell Formula bar Column heading Row heading Worksheet tab.
Accutome A-scan Plus Connect ® Visual Aid
1 Excel Lesson 2 Organizing the Worksheet & Formulas Microsoft Office 2010 Introductory Pasewark & Pasewark.
When the program is first started a wizard will start to setup your Lemming App. Enter your company name and owner in the fields designated “Company Name”
When the program is first started a wizard will start to setup your Lemming App. Enter your company name and owner in the fields designated “Company Name”
Chapter 5 Working with Multiple Worksheets and Workbooks Microsoft Excel 2013.
Distribution Statement A: Unlimited Distribution Introduction to Microsoft PPT.
Learning With Computers I (Level Green) ©2012 Cengage Learning. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly.
Avon Community School Corporation. INTEGRADE PROPOWERTEACHER  Multi-step functions  Limited in features  Not web-based  Must export grades  Must.
Adobe Illustrator CS Design Professional WITH ILLUSTRATOR GETTING STARTED.
Chapter 8 Using Document Collaboration, Integration, and Charting Tools Microsoft Word 2013.
Training Guide for Residents
Multi camera.
ECDL ECDL is an important building block, equipping you with the digital skills needed to progress to further education and employment. ECDL teaches you.
Word Lesson 1 Microsoft Word Basics
Word Lesson 1 Word Basics
Practical Office 2007 Chapter 2
Computer Fundamentals 1
Audacity Presented by Carrie Walter
Microsoft Excel.
Microsoft Access 2007 – Level 2
Microsoft Access 2007 – Level 1
WORKSHOP 2 VALVETRAIN MECHANISM
WORKSHOP 2 VALVETRAIN MECHANISM
Microsoft Outlook By: Phuong Nguyen.
About SharePoint Server 2007 My Sites
Microsoft Word 2016 Lesson 4 Prepared 2/13/11.
Comprehend. Create. Communicate. Achieve More.
Central Document Library Quick Reference User Guide View User Guide
Microsoft Excel 2007 – Level 1
Basic editing Word 2016.
Creating a Worksheet and an Embedded Chart
Microsoft Excel All editions of Microsoft office.
NOTES for S1. Start by drawing a LINE. Move MOUSE POINTER (MP) over INSERT TAB of TOP MENU and Left.
NORMA Lab. 2 Revision: Unary and Binary Fact Types Ternary Fact Types
Basic Editing Lesson 2.
بسم الله الرحمن الرحيم.
European Computer Driving Licence
Chapter 2 Creating a Research Paper with References and Sources
Introduction to PowerPoint
POWER POINT WHY HAVE WE USE THIS PROGRAM? TO SHOW YOUR STUDY..
Shelly Cashman: Microsoft Word 2016
ICT Spreadsheets Lesson 1: Introduction to Spreadsheets
Using the QGIS Layout Manager to create
Word Lesson 1 Word Basics
Welcome to WebCRD.
Microsoft Excel 2007 – Level 1
Autodesk Inventor Tips and Tricks for New Users
Shelly Cashman: Microsoft Excel 2016
Microsoft PowerPoint 2010 Lesson 2.
Lesson 1 – PowerPoint Essentials
University of Warith AL-Anbiya’a
HIBBs is a program of the Global Health Informatics Partnership Learning the Basics of Microsoft Word 2019 and Microsoft office support TFN
Lab 08 Introduction to Spreadsheets MS Excel
Exploring iMovie iMovie sits at the center of the iLife suite, integrating iTunes, iPhoto, and iDVD to help create professional-looking films with music,
Welcome To Microsoft Word 2016
Presentation transcript:

Visual Aid

Table of Contents A-Scan Mode …………………………………Page 3 B-Scan Mode …………………………………Page 15 UBM ………………………………..……………Page 23 Pachymeter.……………………..……………Page 31

Accutome 4Sight: A-Scan

Probe Position Insert probe through the hole on the top of the immersion shell. Do not push the probe past the scored line. Gently twist the screw on the side of the shell, locking the probe into position. Do not over tighten. Note: It is important that the probe does not pass the etched line in the immersion shell. If the probe is placed too far into the shell, you risk missing part of the cornea spike. 2. 1.

A-Scan New Exam To begin a new exam, click the New Patient button and fill in the appropriate fields for patient information. Once the appropriate fields have been filled, select the A-Scan icon. A-Scan Icon Patient Info New Patient Button

Measurement Screen and IOL Calculation Modes After entering the measurement screen, make sure all desired settings are selected, such as capture mode, immersion/contact, eye type, OD/OS, and Gain. There are two control tabs used to navigate between Measurement and IOL Calculation Modes. Measurement Screen and IOL Calculation Modes Gain Capture Mode Eye Type Contact/ Immersion

Scan Alignment Proper scan alignment: All spikes must be present and reach top of screen. Cornea Back Of Lens Sclera Front of Lens Retina

Scan Alignment The most common errors are a weakened posterior lens or retina spike. If these spikes are weakened or do not reach the top of the screen, a slight adjustment to the immersion shell or patient fixation is needed. Posterior Lens Retina

Scan Alignment A missing sclera spike indicates the probe is aimed into the optic nerve. If getting an optic nerve shot, the shell should be adjusted inferior and temporally. An optic nerve scan where the sclera spike is not present will produce an erroneously long measurement. Sclera

Gain Increasing the gain amplifies the echoes on the display screen. More gain is required for denser cataracts. When gain is too high, the scan becomes oversaturated resulting in a shorter than actual axial length. To increase the gain, simply turn the knob on the screen with the mouse. Default gain should be around 67 dB. Psuedophakic eyes will need the gain to be turned down to reduce noise produced from the intraocular lens. Gain Knob

Gates Gates are used by the software to detect and identify the different spikes in the waveform used to make the measurement. The gates are the dotted lines on the screen, and the markers (red triangles on the base line) mark the identified spike and point of measurement. In order to adjust the gates, simply “click and drag” the gate to the appropriate position– the red marker will move accordingly.

Reports Print Settings Snapshot Report Save Edit Selecting Report under the measurement tab, will generate a 2 page A-Scan report. One page for OD, one for OS. This report will show all 5 scan waveforms for each eye.

IOL Calculation Select the IOL Calculation tab to enter the calculation screen Switch between different lens groups Add, Edit, or Delete Lenses/Lens Groups AXL – Axial Length, K1, K2, and Post-Op target Select desired formula for calculation Select report to generate a 1 page calculations printout

Sample of IOL Calculations Report

Accutome 4Sight: B-Scan

B-Scan New Exam To begin a new exam, click the New Patient button and fill in the appropriate fields for patient information. When starting a B-Scan exam, make sure appropriate sequence is selected. Once the appropriate fields have been filled, select the B-Scan icon. Patient Information B-Scan Icon New Patient Button B-Scan/UBM Sequences

Probe Alignment Accutome logo indicates direction of probe oscillation and the top of the screen Start/Stop Button

Scan Screen Select eye OD/OS Orientation dial used to label probe position (optional). Zoom Adjust gain while scanning Zoom Reset A-Vector Take multiple video loops of different positions Comment Cine Buffer shows a progress bar when probe is running

Scan Screen Measure Tab: 6 lines, 2 area, and 2 angle calipers with 2 arrows Play, Pause, and review the selected view frame by frame. Snapshot Report Print Save Edit Settings

Reporting Once all snapshots are taken, select the Report icon.

Reporting Report Options: Preview - brings up the report page as it will look with selected snapshots. Save - saves the report in the folder designated in Setup: General. Review - brings up a list of all of the reports saved for the selected patient. Print – prints the selected scan. Export to DICOM - the selected report exports to the DICOM location designated in Setup: General/ DICOM Servers Report Options Your snapshots will appear at the top of the screen. Hold down the “Ctrl or Shift key” on your keyboard and click on the snapshots you wish to include in your report. Once selected, click “Preview”.

Image Options View Selected Icon - brings up a larger version of the selected snapshot. Delete Selected Images – deletes selected snapshots. Export Selected to DICOM – send the selected image to the DICOM location designated in Setup: General / DICOM Servers. Done - will bring you back to the scan window. Done Icon Image Options

Accutome 4Sight: UBM

Accutome logo indicates direction of probe oscillation Probe Alignment Accutome logo indicates direction of probe oscillation Start/Stop Button

UBM New Exam To begin a new exam click the New Patient button and fill in the appropriate fields for patient information. When starting a UBM exam, make sure appropriate Sequence is selected. Once the appropriate fields have been filled, select the UBM icon to begin the UBM mode. Patient Information New Patient Button UBM Icon B-Scan/UBM Sequences

Scan Screen Select eye OD/OS Orientation dial used to label probe position (optional). Zoom Adjust gain while scanning Zoom Reset A-Vector Take multiple video loops of different positions Comment UBM Focal Guide Cine Buffer shows a progress bar when probe is running

Scan Screen Measure Tab: 6 lines, 2 area, and 2 angle calipers with 2 arrows Play, Pause, and review the selected view frame by frame. Snapshot Report Print Save Edit Settings

Reporting Once all snapshots are taken, select the Report icon. Selecting this button brings up a screen showing small versions of all of the snapshots which are stored for the patient selected. Report Icon

Reporting Report Options: Preview - brings up the report page as it will look with selected snapshots. Save - saves the report in the folder designated in Setup: General. Review - brings up a list of all of the reports saved for the selected patient. Print – prints the selected scan. Export to DICOM - the selected report exports to the DICOM location designated in Setup: General/ DICOM Servers Report Options Your snapshots will appear at the top of the screen. Hold down the “Ctrl or Shift key” on your keyboard and click on the snapshots you wish to include in your report. Once selected, click “Preview”.

Image Options View Selected Icon - brings up a larger version of the selected snapshot. Delete Selected Images – deletes selected snapshots. Export Selected to DICOM – send the selected image to the DICOM location designated in Setup: General / DICOM Servers. Done - will bring you back to the scan window. Done Icon Image Options

Accutome 4Sight: Pachymeter

Pachymetry New Exam To begin a new exam, click the New Patient button and fill in the appropriate fields for patient information. Once the appropriate fields have been filled, select the Pachymetry icon. Patient Information New Patient Button Pachymeter Icon

Measurement Screen Place probe on the eye in the location selected on the screen. The flat portion of the probe tip should be perpendicular and completely in contact with the patient’s cornea (not at an angle). Measurements will not be obtained unless the probe is in complete contact with the cornea. Select the eye OD/OS and the scan location on the cornea Start Reading will begin the scan

Measurement Screen Once you have captured 9 measurements, you may review those measurements in the chart on the right of the screen. Repeat process on different locations of the cornea or on fellow eye Select Save to save all scans After Save, Select Report icon. Selecting this will generate a Pachymetry Report. Report Save

Sample Pachymetry Report All Regions scanned will display on the report giving all nine measurements and the average for that location. Entering a Measured IOP will then calculate an adjusted IOP based on the pachymetry measurements.

Notes _______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________