Setup for routine testing of SuperNEMO scintillators in Prague NEMO3 and SuperNEMO Collaboration Meeting in Prague Aivaras Žukauskas, Charles University in Prague 27.01.2009, Prague
NEMO3/SuperNEMO collaboration meeting, Prague Overview Motivation Black box XY table, main parameters Functionality test Scintillator's response vs irradiation position Summary and plans 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
NEMO3/SuperNEMO collaboration meeting, Prague Motivation Routine tests of big amount of scintillators should be shared among several laboratories Prague will participate in the tests Details of a testing procedure are not decided yet Some setups already exist (Bordeaux, Dubna, ...) Proposal of F.Piquemal for „multibox setup“ Plan – setup in IEAP CTU Prague Prototype setup in IPNP CU Prague 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
NEMO3/SuperNEMO collaboration meeting, Prague Black box Steel black box, 100 x 130 x 130 cm XY table easily fits inside enough space for testing bigger scintillators Aluminum bottom window 40x40 cm for electrons outcomming from spectrometer Supporting structure prepared to carry the XY table with spectrometer movable on wheels 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
XY table, main parameters Range (max.): 40x40 cm Step = 25 m Velocity: 38 cm/min Load: designed for 100 kg, tested: 35 kg Operating: serial port PC 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
NEMO3/SuperNEMO collaboration meeting, Prague Functionality test PMT Spectrometer amplifier PC X Y 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
Functionality test: arrangement PMT 3" Photonis XP5312 Scintillator 50x50x20 mm, teflon wrapping, Al mylar entrance Fixed Movable Al filter, 3 mm Pb collimator, 10mm, 45x80x80 mm XY movable 207Bi source, 160 kBq 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
Pb collimator with Al filter 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
Scintillator response vs irradiation position position scan Peak position, ADC Irradiated area 11.6 mm FWHM @ 1 MeV, % 91.5 88.6 85.5 20 mm 20 mm 11.8 13.8 14.1 87.3 88.7 91.9 12.7 11.5 13.9 90.6 92.5 89.9 13.7 11.9 12.5 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague
NEMO3/SuperNEMO collaboration meeting, Prague Summary and plans The prototype for routine scintillator tests is built and tested. XY table is functioning well with the load of 35 kg. We are prepared to read and analyze data (work is in progress). Prototype will be equipped with 90Sr/90Y source (spectrometer); New testing setup will be built at IEAP CTU based on our experience with the prototype, Bordeaux, Dubna, … 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague / 10
NEMO3/SuperNEMO collaboration meeting, Prague Backup slides 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague
NEMO3/SuperNEMO collaboration meeting, Prague PMT, electronics Photonis PMT XP5312B (3") XP3540B (5") Voltage splitter VD202K/01 ORTEC ScintiPack ADC – PC card 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague
NEMO3/SuperNEMO collaboration meeting, Prague Scintillators Polystyrene, Dubna 50x50x20 mm hexagon with diameter 100 mm, 20 mm thick 100 mm 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague
NEMO3/SuperNEMO collaboration meeting, Prague XY table, components GLEICH – Al desks 70x70x2 cm 70x30x2 cm 30x30x2 cm MICROCON 2x step motor 2x controller 1x power supply operating software HIWIN 4x rails, 700 mm 8x carts 2x screwed rods, 590 mm bearings etc. 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague
NEMO3/SuperNEMO collaboration meeting, Prague Black box Steel construction, 100 x 130 x 130 cm XY table easily fits inside a lot of space for testing bigger scintillators Supporting structure is able to carry the spectrometer and XY table is on wheels – enables to move the black box easily Thin aluminum bottom (xx mm) 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague
NEMO3/SuperNEMO collaboration meeting, Prague Double Gaussian fit 27.01.2009 NEMO3/SuperNEMO collaboration meeting, Prague