New AGA Devices PDA II, Vascular Plug IV, Membranous VSD and and Left Atrial Appendage Occluder Dr. John M. Lasala MD PhD Director Interventional Cardiology.

Slides:



Advertisements
Similar presentations
Transcatheter LAA Occlusion
Advertisements

VSD Case Discussion. Patient Data 23 y/o female 23 y/o female Underline Disease: Underline Disease: 1. Large VSD 2. Pulmonary hypertension, secondary.
Acyanotic Heart Disease PRECIOUS PEDERSEN INTRODUCTION Left to right shunting lesions, increased pulmonary blood flow The blood is shunted through.
Congenital Heart Disease Cheston M. Berlin, Jr., M.D. Department of Pediatrics.
Indicated for Arterial and Venous Embolizations in the Peripheral Vasculature April, 2004.
Amplatzer® Septal Occluder
Disclosure Information Devices for ASD&PFO Closure: Amplatzer Devices As a faculty member for this program, I disclose the following relationships with.
Update of Transcatheter Closure of Ventricular Septal Defect in China Yong-wen Qin Department of Cardiology, Changhai Hospital, Second Military Medical.
Acyanotic Congenital Heart Disease
Indications for intervention of ASD and VSD
Jonas D. Del Rosario, MD, FPCC Clinical Associate Professor UP College of Medicine.
Pulmonary Atresia and Intact Ventricular Septum
Atrial Septal Defect Closure
Current Status and Prospect of Interventional Congenital Heart Disease
Congenital heart disease
Transcatheter ASD closure, sans X-rays Peter Ewert MD Robert Beekman MD.
C ASE REPORT FOR V. GRADE STUDENTS Cardiology Dr. Kemény Viktória.
Date of download: 5/28/2016 Copyright © The American College of Cardiology. All rights reserved. From: Pediatric Cardiac Interventions J Am Coll Cardiol.
H. Amoozgar, MD Professor of pediatric cardiology Shiraz University of Medical Sciences, Shiraz, Iran TRANSCATHETER CLOSURE OF LARGE CORONARY-CAMERAL FISTULAE.
Chris Burke, MD. What is the Ductus Arteriosus? Ductus Arteriosus  Allows blood from RV to bypass fetal lungs  Between the main PA (or proximal left.
Congenital Heart Disease
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: Imaging the Left Atrial Appendage Prior to, During,
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: Closure of Atrial Septal Defects With the Amplatzer.
Date of download: 6/22/2016 Copyright © The American College of Cardiology. All rights reserved. From: Management of coronary artery fistulae: Patient.
Date of download: 9/18/2016 Copyright © The American College of Cardiology. All rights reserved. From: Further experience with transcatheter closure of.
VSD post TAVR: Mechanisms, Presentation and Management
Complex ASD Closures John M
Post-FDA Approval, Initial US Clinical Experience with Watchman Left Atrial Appendage Closure for Stroke Prevention in Atrial Fibrillation Vivek Y. Reddy.
PERCUTANEOUS PULMONARY VALVE REPLACEMENT:
Issues and Current Situations in the Development of Endovascular Treatment Devices for Pediatric Cardiology in the US – US Industry Dan Gutfinger, MD,
LAAC: What Does the Post Marketing Data Tell Us?
Prof. Dr. med. H. R. Figulla Director at the University Hospital Jena
Post-FDA Approval, Initial US Clinical Experience with Watchman Left Atrial Appendage Closure for Stroke Prevention in Atrial Fibrillation Vivek Y. Reddy.
Aimee K. Armstrong, MD, FACC, FSCAI
Challenging Case Presentation For Structural Heart Disease Program
Successful Removal of Entrapped and Kinked Catheter during Right Transradial Cardiac Catheterization by Snaring and Unwinding the Catheter via Femoral.
Mitralign Program Update
Special Hospital for surgical diseases “Filip Vtori”, Skopje
Successful retrieval of embolized atrial septal defect and patent foramen ovale closure device using novel coronary wire trap (CWT) technique. Alireza.
Clinical Presentation
Endurant: A New Generation Endograft
A Novel “Stent-On-A-Wire”Ultra Low Profile Stent Delivery System
Objectives 1-To discuss V.S.D.
Percutaneous Closure of a Coronary Fistula
CRT Washington, D.C. February 23, 2010 Tim A. Fischell, M.D. FACC
A Fixed Guidewire Stent Delivery System
A Primer of LAA Closure: and Pattern Recognition
Patrick Redmond MD Interventional Radiology Fellow BIDMC
CONGENITAL HEART DISEASES II
Recanilization of Central Venous Total Occlusions
A Primer of LAA Closure: and Pattern Recognition
Fractional Flow Reserve Workshop
Transcatheter closure of postinfarction ventricular septal rupture
Patent Ductus Arteriosus Occlusion Device
Nat. Rev. Cardiol. doi: /nrcardio
Venous System Interventions for Device Implantation
Operative Techniques for Repair of Muscular Ventricular Septal Defects
Left atrial appendage closure: A new technique for clinical practice
Minimally invasive transthoracic device closure of isolated ventricular septal defects without cardiopulmonary bypass: Long-term follow-up results  Quansheng.
Transcatheter closure of postinfarction ventricular septal rupture
Balu Vaidyanathan, Sumantha Sekhar Padhi, Ananthen KS, BRJ Kannan,
Impact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysms  Michael L. Marin, MD, Richard E. Parsons,
(A-B) the Coherex WaveCrest LAA occlusion system is the latest development in LAA occlusion devices. (A-B) the Coherex WaveCrest LAA occlusion system is.
Karim A. Diab, MD, Ziyad M. Hijazi, MD, Qi-Ling Cao, MD, Emile A
Hidehiko Hara et al. JIMG 2008;1:92-93
Heart Failure Dr Elspeth Brown Consultant Paediatric Cardiologist
Surgical closure of apical ventricular septal defects through a right ventricular apical infundibulotomy  Giovanni Stellin, MD, Massimo Padalino, MD,
Device-specific CT-based LAA occluder size selection.
Evaluation of a novel device for left atrial appendage exclusion: The second-generation atrial exclusion device  Keiji Kamohara, MD, Kiyotaka Fukamachi,
(A-B) the ACP device consists of a lobe and a disk connected by a short, flexible waist. (A-B) the ACP device consists of a lobe and a disk connected by.
Presentation transcript:

New AGA Devices PDA II, Vascular Plug IV, Membranous VSD and and Left Atrial Appendage Occluder Dr. John M. Lasala MD PhD Director Interventional Cardiology and Cardiac Cath Barnes-Jewish Hospital Professor of Medicine Washington University St. Louis, Missouri

Conflict of Interest Speaker and Proctor AGA Medical/ St Jude Medical Note: Some Products in this presentation are not FDA Approved

Patient complained of chest pain and dyspnea LAD to RV Fistula Patient complained of chest pain and dyspnea CT Scan noted Fistula

LAO Cranial Projection Note enlarged hypocontractile RV

Forming the AV Loop Choice Floppy Wire through Cook Miraflex Catheter placed in PA and captured with 25 mm Gooseneck Snare and externalized through right IJ

Positionment of Delivery Catheter “Cut Down” 100 cm JR4 Catheter or 55cm Renal Catheter advanced over AV loop into LAD

Deployment of 8mm Amplatzer Vascular Plug II Measurements are often Estimates!

Redeployment Using10 mm Vascular Plug II . Note all three discs are exposed

Final Position of Vascular Plug Note slow flow in LAD Without Shunt Will need to keep on ASA and Coumadin Revaluate in 6 months with CT Scan for Regression

Devices for Peripheral Vascular Occlusion AMPLATZER® Vascular Plug 4

Devices for Peripheral Vascular Occlusion AMPLATZER® Vascular Plug 4 AGA Medical Corporation Device description Dual-lobe, dual-layer Nitinol mesh with a floppy delivery wire tip for targeted delivery in distal and tortuous anatomy Delivery system 0.035 Diagnostic Cath 4Fr Device size 5 sizes from 4mm to 8mm Product Approval and Indication CE Mark Jul 2009 – Peripheral Vascular Occlusion

Gastroduodenal Artery Embolization with AVP 4 before Selective Internal Radiation Therapy Courtesy Thomas Kroencke (DE)

PDA Very common defect. True incidence unknown since many PDAs are silent Indications for closure include evidence of LV or LA enlargement or the presence of a heart murmur consistent with the PDA Treatment of “silent” PDAs controversial

PDA < approx 2 mm diameter may be closed with coil occlusion

Amplatzer duct occluder used for PDAs > 2 mm diameter PDA device occlusion Amplatzer duct occluder used for PDAs > 2 mm diameter

Amplatzer duct occluder First generation device must be delivered from pulmonary side

Amplatzer duct occluder

Devices for Closure of Structural Heart Defects AMPLATZER® Duct Occluder II

AMPLATZER® Duct Occluder II AGA Medical Corporation Device description Low-profile, self-expanding double braided nitinol device with two retention discs, central lobe. The symmetric design allows delivery from either arterial or venous approach. Delivery system 4Fr or 5 Fr TorqVue Low Profile Catheter Device size 8 sizes – 3, 4, 5, 6 mm waist each in 4 and 6 mm length Product Approval and Indication CE Mark Jan 2008 for PDA U.S. Trial Jan 2008 for PDA

Devices for Closure of Structural Heart Defects AMPLATZER® Duct Occluder II Additional Sizes

AMPLATZER® Duct Occluder II Additional Sizes AGA Medical Corporation Device description Low-profile, self-expanding single-layer braided Nitinol device with two flat retention discs, central lobe, and micro end-screw designed to for less protrusion into the Aorta or Pulmonary Artery Delivery system 4Fr TorqVue Low Profile Catheter Device size 9 sizes – 3, 4, 5 mm waist each in 2, 4, 6 mm length Product Approval and Indication CE Mark Jan 2011 – Patent Ductus Arteriosus

ADO II AS Implantation

Congenital VSDs VSDs are the most common form of congenital heart disease Approx 20% of pts with CHD have a VSD as the solitary lesion Echo studies demonstrate an incidence of 5-50/1000 newborns Adult cardiologists mostly deal with post-MI VSDs

Congenital VSDs Ventricular septum viewed from the RV is divided into the inlet (I), outlet (O), and trabecular portions (T) Anatomic locations of VSDs include outlet (a), membranous (c), muscular(d,e,g), and inlet (f)

Congenital VSDs Inlet and outlet type VSDs are not currently amenable to transcatheter closure Muscular defects can be closed with either the Amplatzer muscular VSD occluder or the cardioseal device Membranous VSDs can be closed with the Amplatzer membranous VSD device but this is not currently approved in the US

VSD Types 1 – outflow portion of RV spontaneous closure uncommon 2 – perimembranous - most common – 80% 3 – inlet VSD in lower RV near TV, often in Down syndrome 4 – muscular, 20% of VSDs in infants, spontaneous closure is common Warnes CA, et. al. VSD. ACC/AHA 2008 guidelines for the management of adults with congenital heart disease. J Am Coll Cardiol 2008;52(23):e173-78.

Amplatzer Muscular VSD Device 6-8 Fr delivery sheath for MVSD 9-10 Fr delivery sheath for PIVSD

Amplatzer MVSD Implantation LV angiogram Selection of appropriate sized device based on TTE, TEE, & angiograms Crossing of VSD and externalization of wire

Amplatzer MVSD Implantation Removal of wire Passage of device from transjugular of femoral venous approach

Amplatzer MVSD Implantation Release of device from delivery system Follow up angiogram

Devices for Closure of Structural Heart Defects AMPLATZER® Membranous VSD 2

AMPLATZER® Membranous VSD 2 AGA Medical Corporation Device description Dual-layer braided Nitinol device with central waist, LV sail/wing-shaped disc, & RV circular disc designed to provided minimal force on the adjacent tissues while maintaining stability & closure Delivery system TorqVue 4 Delivery System (6-9 Fr) Pusher (6/7 & 8/9 Fr) Device size 18 sizes 9 waist diameters: 4-10,12,14mm Each available in rim lengths: 1mm & 3mm Product Approval and Indication CE Mark Anticipated Q2 2011 – Membranous VSD

Implantation Video

Left Atrial Appendage Closure

Ubiquitous anatomy

Watchman Endocardial fourth generation

Coherex

AMPLATZER Cardiac Plug (polyester material and thread not visible) PROXIMAL Disc Proximal Screw attachment Marker band Central waist Lobe Platinum thread Distal Screw attachment Marker band Stabilizing wire DISTAL

AMPLATZER® Cardiac Plug CE Mark 2008 Implants ongoing WW EU Registry First Patient Enrolled 8/2009 20 Sites Sample size of >200 US IDE Feasibility study initiated in Q3/2010 After completion of feasibility Pivotal phase of trial to begin

Thrombus in the LAA

AMPLATZER® Cardiac Plug

AMPLATZER® Cardiac Plug Device Description Transcatheter self-expanding device intended for use in preventing thrombus embolization from the left atrial appendage Delivery System TorqVue® 45° x 45° Delivery Sheath: 9, 10 and 13 Fr. Sizes Device Size Eight sizes: 16 – 30 mm in 2 mm increment; Disc Dia. 4 or 6 mm > Lobe Dia.; Covering 18 – 28 mm LAA Orifice Product Approval and Indication CE Mark since Q4 2008 U.S. Clinical Feasibility Trial Q2 2010

ACP Implantation -Fluoroscopy

ACP Implantation - TEE

Conclusions 1. The newest Line of AGA products include upgrades of the vascular plug and ductal occluder and the introduction of the membranous VSD and cardiac LAA plug 2. None of these products are currently avavilable in the US but have ongoing European experience. 3. For now US physicians will have to make do with earlier generations. 4. The Cardiac LAA occluder hopes to begin randomized evaluation next year