LP Feedwater Heater Tube Failure Point Beach Nuclear Plant

Slides:



Advertisements
Similar presentations
Power Uprate Lessons Learned Point Beach Nuclear Plant 2011 Units 1 & 2 Kelly Oetting BOP System Engineer FSRUG 2012 Conference January 23-26, 2012.
Advertisements

Analysis of heat exchangers: Use of the log mean temperature Difference LMTD Method: Q= (m cp ∆T) h = (m cp ∆T) c Q= U A F∆T lm A=N װ DL ∆ T lm = ∆T l.
TROUBLESHOOTING. 5WSS TROUBLESHOOTING ERROR CODEFAULTY INDICATION E1ROOM SENSOR CONTACT LOOSE E2INDOOR COIL SENSOR CONTACT LOOSE E3WATER OUTLET SENSOR.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
MAINTENANCE DEPARTMENT Presented by: John Argabright, Maint. Supervisor Muskingum River Plant APP Site Visit October 30 – November 4, 2006.
HATCH UNIT 1 CONDENSER HOTWELL DAMAGE & LONG CYCLE CLEANUP VALVE LEAKAGE FORCED OUTAGES JAN 2013 & OCT 2013.
DRIP DISPERSAL SYSTEMS Problems and Solutions. Flow Equalization Surges in the ATU during peak loading are a major cause of filter clogging in a drip.
Shell and Tube Heat Exchanger October 7, 2003 Cycle 2 Group 1A Frank Fadenholz Jennifer Fadenholz Christian Woods Angel Taylor.
GNI0003H PP1 Loop Trainer. GNI0003H PP2 Reason for Study Because the Loop Trainer gives instructors the capability to control water flow, pressure and.
2008 User Conference& Technology Fair South Texas Project Feed Reg Valve Positioner Replacement.
ACADs (08-006) Covered Keywords Pressurized Water Reactor (PWR), Boiling Water Reactor (BWR), primary loop, reactivity, reactivity control, reactivity.
Advanced Maintenance Provider  Aeration Equipment …
"AIR COOLER" Heat Exchanger
1 Heat Exchangers. Standards of Conduct in Training 2.
Walter G Bischoff Brunswick station Duke Energy
MIS 5241 Three Mile Island What Happened, What Worked, What Didn’t.
Dakota Nickerson, Kyle Pflueger, Adam Leschber, Andrew Dahlke M.E. Undergrad 1.
Dakota Nickerson, Kyle Pflueger, Adam Leschber, Andrew Dahlke M.E. Undergrad 1.
Feedwater Heater Heat Transfer Richard Galati Brent Smith Justin Pierce.
SGFP Lube Oil Systems & Maintenance – Part 2
2 July Turbine Condensate System
A Train of Closed Feed Water Heaters A Trade off between Irreversibility and Reliability !!! P M V Subbarao Professor Mechanical Engineering Department.
NEIL Requirements for Testing of FWH Electrical Equipment and AOV’s.
Feedwater Systems Reliability Users Group Annual Meeting January 20-23, 2014 Feedwater Pump Thrust Bearing Failure Presented By: Kurt J. Weis Rotating.
Oil Pressure Problems What to look for.
ACADs (08-006) Covered Keywords Description Supporting Material
ICE PLUG MONITORING SYSTEM Ice plug is an efficient method of providing isolation on liquid filled (water, heavy water) pipes to perform maintenance and.
Introduction: True North Consulting, LLC Phone (970)
Cyclohexane Production Unit
Quantifying Cycle Isolation Losses and Integration with On Line Systems Feedwater System Reliability Users Group 2015 Meeting San Antonio Ken Porter Rich.
Floating Head Heat Exchanger
FSRUG Presentation – January 2014 Tennessee Valley Authority Browns Ferry Nuclear Plant Unit 3 Reactor Feed Water (FW) Clean Up Piping Break.
Feedwater System Reliability Users Group – 2012 Meeting Power Uprates & Feedwater Heaters 1.
“Fix Tube Sheet” Heat Exchanger
Energy Seminar Emerson Process Management June 22/23, 2010.
Engineering Internship at the Schuyler Beef Plant Jade Titus Cargill Meat Solutions Schuyler, NE.
MSR Effects Upon Secondary Cycle. ## # 666 Heater Drain Pump Main Steam Main Turbine #6 FWH MSR #5 FWH #4 FWH MOV Drain Tank Manual Valve AOV Note: Most.
TEAM GEOMELT. The Team Jacob Speelman (ME) Caleb Rottman (EE) RICO Ledy (ME) Eric Geerlings (CE)
MFW Pump Discharge Check Valve OE Follow Up Dominion North Anna Power Station Gary W. Liffick FW System Engineer FSRUG, Feb 21-24, 2011.
Cryo AIP Muon Campus AIP Review Arkadiy Klebaner January 23, 2012.
Harris Plant – Loss of Main Feed Pump Lube Oil INPO ICES # HNP Root Cause Evaluation
Nuclear Power Plant Orientation
Page 1 Petten 27 – Feb ALFRED and ELFR Secondary System and Plant Layout.
FSRUG Feedwater Systems Reliability Users Group (Jan 2013) San Antonio, TX SGFP Lube Oil Systems & Maintenance – No Problems Presenter: Art Washburn, P.E.
I & C.
BOILER MOUNTINGS & ACCESSORIES
Series Loop Concept Adv Dis.
Heat Technologies Dana Albers. Heating Systems Definition: a device or system for supplying heat, central heating, to a building Heater Heating system.
5/15/ meeting. -21 work days to shutdown -31 calandar days to shutdown -Today is May 15 th all Jobs are supposed to be entered in the work list.
Temperature Test Allows monitoring of temperature changes.
Review Questions Chapter 5
How to Draw a Systems Diagram
AUTOMOTIVE COOLING SYSTEMS
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
Heat Exchangers and Condensers
PHOTO GALLERY Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 7th edition by Yunus A. Çengel and Michael A. Boles.
AN INTEGRAL PWR, “CAREM”, IS BEING DEVELOPED BY CNEA, ARGENTINA
Cryogenic behavior of the cryogenic system
Thermodynamics Cycles.
Water in Oil – Feedwater Pump Point Beach Nuclear Plant
Which Parts Get Affected Due to a Bad Radiator
A Train of Closed Feed Water Heaters
PRODUCTS (POWER PLANT)
PINGP Unit 1 & Unit 2 MUR 2010 Lessons Learned
Floating Head Heat Exchanger
1) 1.1) 1.2) Another relation for critical flux.
Leveraging Glass Panel Simulator Usage
Cryogenic behavior of the magnet
UPPSALA UNIVERSITY_GERSEMI PROJECT
INTRODUCTION ALAQUA is a US corporation. We manufacture process equipment. Our engineers have over 20 years experience in the engineering of sanitary and.
Presentation transcript:

LP Feedwater Heater Tube Failure Point Beach Nuclear Plant Kelly Oetting System Engineer FSRUG 2015 Conference January 26-29, 2015

2011 Power Uprate Westinghouse 2 – Loop PWR, Unit 1 1970, Unit 2 1972 17% 545 MWe to 637 MWe (1540 MWth to 1800 MWth) Unit 2 – 120 Days (3/1/11 - 6/19/11) Unit 1 – 75 Days (10/3/11 – 12/17/11) Approximately 35 Major Modifications for Each Unit New FWHs 5 Stages, Two Trains (4 LP & 1 HP FWH/Train)

New #1 & #2 Duplex LP FWH

FWH Design Change Details Before EPU After EPU #1 & #2 LP FWHs Westinghouse (shell) Southwest Eng. (tube bundle) Yuba Length 41 ft 9 in 49 ft Diameter 68 in 79.25 in Heat Transfer #1 147,500,000 Btu/hr 141,100,000 Btu/hr Heat Transfer #2 116,700,000 Btu/hr 126,600,000 Btu/hr

#2 FWH Tube Failures April 2014 - #1&#2 Drain valves started opening more May 2014 - #1&#2 Dump Valve started to open Step change down in #2 drain temperature Monitored until October 2014 Refueling outage Found 6 tubes leaking in #2 FWH 2 tubes sheared off Stabilizers installed in 14 tubes 16 tubes plugged

Motor Bearing Housing Sightglass

Potential Causes Water level too low – knee test never performed Drain piping and/or drain valve sized too small

Actions Raised level in all #1, #2, and #3 FWHs Will be pursuing a study of the drain piping.