X-ray CCD with low noise charge injection.

Slides:



Advertisements
Similar presentations
Activity 1 : Introduction to CCDs.
Advertisements

Radiation damage in silicon sensors
1 Konstantin Stefanov, CCLRC Rutherford Appleton Laboratory LCFI Status Report: Sensors for the ILC Konstantin Stefanov CCLRC Rutherford Appleton Laboratory.
Cable Properties Properties of the nerve, axon, cell body and dendrite affect the distance and speed of membrane potential Passive conduction properties.
EPIC Calibration Meeting, K. Dennerl VILSPA/Spain, 2003 Mar Temporal variation of the energy response determined with the internal calibration source.
X-ray Imaging Spectrometers (XIS) of Astro-E2 Hironori Matsumoto (Kyoto University) and the XIS team 1. Overview Astro-E2 is the fifth Japanese X-ray Astronomy.
3D simulations of device performance for 3D-Trench electrode detector Jianwei Chen a,b, Hao Ding a,b, Zheng Li a,b,c, *, Shaoan Yan a,b a Xiangtan University,
Development of an Active Pixel Sensor Vertex Detector H. Matis, F. Bieser, G. Rai, F. Retiere, S. Wurzel, H. Wieman, E. Yamamato, LBNL S. Kleinfelder,
CHARGE COUPLING TRUE CDS PIXEL PROCESSING True CDS CMOS pixel noise data 2.8 e- CMOS photon transfer.
Standalone VeloPix Simulation Jianchun Wang 4/30/10.
Department of Physics VERTEX 2002 – Hawaii, 3-7 Nov Outline: Introduction ISE simulation of non-irradiated and irradiated devices Non-homogeneous.
06/02/2008CCDs1 Charge Coupled Device M.Umar Javed M.Umar Javed.
Photomultiplier Tube m = k 8–19 dynodes (9-10 is most common).
1 Fall 2004 Physics 3 Tu-Th Section Claudio Campagnari Lecture 15: 18 Nov Web page:
Charge-Coupled Device (CCD)
1/23/ Proton Radiation Damage in High- Resistivity n-Type Silicon CCDs C. Bebek, D. Groom, S. Holland, A. Karcher, W. Kolbe, J. Lee, M. Levi, N.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
XIS FM sensors cal. report Hiroshi Nakajima XIS
Measurement and Simulation of the Variation in Proton-Induced Energy Deposition in Large Silicon Diode Arrays Christina L. Howe 1, Robert A. Weller 1,
CCD Detectors CCD=“charge coupled device” Readout method:
Performances of the COROT CCDs for high accuracy photometry Pernelle Bernardi and the CCD team From Meudon : Tristan Buey, Vincent Lapeyrere, Régis Schmidt,
1 Digital Active Pixel Array (DAPA) for Vertex and Tracking Silicon Systems PROJECT G.Bashindzhagyan 1, N.Korotkova 1, R.Roeder 2, Chr.Schmidt 3, N.Sinev.
Jim Brau, Amsterdam, April 2, Nikolai Sinev and Jim Brau University of Oregon April 2, 2003 Radiation Damage Studies of Vertex Detector CCDs First.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Specifications & motivation 2  Lowering integration time would significantly reduce background  Lowering power would significantly reduce material budget.
1 Investigation into properties of neutron and electron irradiated CCD By Nick Sinev University of Oregon Jim Brau, Jan Strube, Olya Igonkina, Nick Sinev.
3/16/04mwb, sek, MIT/CSR MIT XIS Status 16 March 2004 Overview: TCE board rebuild status Back-illuminated CCD performance & status (Slightly) improved.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
TIPS - Oct 13, 2005 M. Sirianni Temperature change for ACS CCDs: initial study on scientific performance M. Sirianni, T. Wheeler, C.Cox, M. Mutchler, A.
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 2 Paul Dauncey Imperial College London.
SIAM M. Despeisse / 29 th January Toward a Gigatracker Front-end - Performance of the NINO LCO and HCO Matthieu Despeisse F. Osmic, S. Tiuraniemi,
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
SPIE Astronomical Instrumentation June 26, 2008 Physics of reverse annealing in high- resistivity ACIS Chandra CCDs Catherine E. Grant (MIT) Bev LaMarr,
CMOS MAPS with pixel level sparsification and time stamping capabilities for applications at the ILC Gianluca Traversi 1,2
CMOS Sensors WP1-3 PPRP meeting 29 Oct 2008, Armagh.
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
General detectors. CCDs Charge Coupled Devices invented in the 1970s Sensitive to light from optical to X-rays In practice, best use in optical and X-rays.
3 May 2007 Suzaku Users mwb MIT/MKI XIS Update Mark Bautz, MIT Kavli Institute XIS-2 Anomaly Contamination.
The onboard calibration for the spaced-row charge injection of the Suzaku XIS Hideki Uchiyama, Yoshiaki Hyodo, Hiroya Yamaguchi, Hideyuki Mori, Takeshi.
10/25/2007Nick Sinev, ALCPG07, FNAL, October Simulation of charge collection in chronopixel device Nick Sinev, University of Oregon.
Astro-E2 X-ray Imaging Spectrometer Status, Performance and Calibration Astro-E2 Users’ Group 14 February 2005 Mark Bautz, MIT CSR.
Application of a Charge Transfer Model to Space Telescope Data Paul Bristow Dec’03
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Topic Report Photodetector and CCD
Clear Performance and Demonstration of a novel Clear Concept for DEPFET Active Pixel Sensors Stefan Rummel Max-Planck-Institut für Physik – Halbleiterlabor.
1 Topic Report Photodetector and CCD Tuan-Shu Ho.
ASICs1 Drain Current Digitizer Chip (DCD) Status and Future Plans.
Budker INP V.Aulchenko1,2, L.Shekhtman1,2, V.Zhulanov1,2
Fully Depleted Low Power CMOS Detectors
HEC I chip design Short summary (J.Bán).
Revision CHAPTER 6.
Mitigating CTE losses: Charge Injection and Pre/Post Flash
Introduction Euclid Mission Weak Lensing Radiation damage
First Testbeam results
HV-MAPS Designs and Results I
Charge Coupled Device Advantages
T. Nuns, C. Inguimbert, S. Soonckindt - ONERA- DPhIEE
Trap Pumping Method Importance of inter-phase trapping
SCIENTIFIC CMOS PIXELS
Yasuhiro Sugimoto KEK 17 R&D status of FPCCD VTX Yasuhiro Sugimoto KEK 17
Vertex Detector Overview Prototypes R&D Plans Summary.
Turning photons into bits in the cold
Energy Response of the X-ray Imaging Spectrometer (XIS) on Suzaku
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
TCAD Simulation and test setup For CMOS Pixel Sensor based on a 0
Semiconductor Detectors
More Quantum Mechanics
Beam Test Results for the CMS Forward Pixel Detector
Computed Tomography (C.T)
IN5350 – CMOS Image Sensor Design
Presentation transcript:

X-ray CCD with low noise charge injection. Gregory Prigozhin, Barry Burke1, Marshall Bautz, Steve Kissel, Beverly LaMarr MIT Kavli Institute for Astrophysics and Space Research 1MIT Lincoln Laboratory

Outline: Motivation for adding an input structure. Device architecture, input structure, its operation. Input structure performance, measurement details and results. Applications of the input structure at low signal levels: quick CTI and column nonuniformity estimation, CTI improvement, calibration of charge-volume relation, charge pumping. Conclusions

Charge injection in CCID-41 1. After long discussions we chose serial injection because it provides excellent uniformity (but is slow). 2. In timing diagram the difference with usual fill-and-spill is that the input gate is clocked to maintain the voltage difference and prevent charge flow back into the diode.

Signal and noise as function of gate voltage. ASTRO-E2 electronics controls IG offset with a DAC. The smallest step is 3.8 mV, full span 0.98 V, corresponding to a maximum of ~4000 e-. At very low signal input node capacitance, 0.43 fF is much smaller than determined by S3 area. Due to 2D effects charge occupies very small region under the gate. When it expands, it reaches chan-stop boundaries, and capacitance goes up. Shape of the noise curve is very similar to theoretical prediction of sqrt(kTC/2), but values are higher. The reason for discrepancy not clear.

“Evaporation” of electrons from the potential well

Injection pattern for CTI improvement Charge injection pattern is programmable. “Grid” pattern reduces charge transfer losses due to radiation damage: Charge is injected in each column of every 54th row. Injected charge (temporarily) fills radiation-induced traps. Filled traps will not degrade charge transfer inefficiency. Result is better spectral resolution. Charge moves right during injection Input Register Charge moves down during readout Rows filled by charge injection

Energy resolution of irradiated proton irradiated chip Before irradiation: FWHM=132 eV After irradiation without injection: FWHM=210 eV

Energy resolution after irradiation with charge injection Before irradiation: FWHM=132 eV After irradiation with charge injection: FWHM=144 eV

Measuring charge loss in a column using charge injection. If a train of 8 rows is injected, the first one loses charge to empty traps. The following rows can serve as a reference, thus charge loss can be measured. The result is compared to the loss determined with Fe55 X-rays. Charge injection measurement needs just a few frames. X-ray measurement needs thousands. It also does not require a calibration source.

A train of 8 rows filled with charge, image averaged over 15 frames. Scatter in the first row determined by number of traps in a column is significantly larger than scatter in the following rows determined by injection noise.

Measurement of charge-volume relationship Charge loss is proportional to the number of traps in the volume V occupied by the charge packet. Thus, measuring loss as a function of charge Q is equivalent to measuring V(Q) dependence. This function is important in modeling CTI as a function of signal. The result (V ~ Q 0.51) is really close to square root dependence at Q >180electrons

CCID-41 in the ASTRO-E2 detector assembly. Frame transfer 1024x1024 array Has 4 output readout nodes Readout noise below 2 electrons rms at 42 kHz Charge injection capability Depletion depth approximately 65 microns

Conclusion We have implemented a charge injection structure for injecting miniscule charge packets (hundreds and even tens of electrons) with a capacitance of 0.43 fF. It has very low noise, about 6 electrons at signal level below 1000 electrons. Using certain patterns of charge injection we were able to significantly improve energy resolution of proton irradiated CCD. Charge injection allows to calibrate column-to-column CTI nonuniformities very efficiently. It is an extremely valuable tool for conducting many experiments, like measuring charge-volume relationship or charge pumping.