Lessons from MODIS Calibration and Characterization

Slides:



Advertisements
Similar presentations
Radiometric Calibration Stuart F. Biggar, U of AZ Kurtis J. Thome, U of AZ Simon J. Hook, JPL.
Advertisements

Evaluating Calibration of MODIS Thermal Emissive Bands Using Infrared Atmospheric Sounding Interferometer Measurements Yonghong Li a, Aisheng Wu a, Xiaoxiong.
Summary of Terra and Aqua MODIS Long-term Performance Jack Xiong 1, Brian Wenny 2, Sri Madhaven 2, Amit Angal 3, William Barnes 4, and Vincent Salomonson.
Aqua MODIS Cold FPA Performance and Operation MODIS Characterization Support Team (MCST) April 25, 2012.
VIIRS Reflective Solar On-orbit Calibration and Performance Jack Xiong and Jim Butler Code 618.0, NASA/GSFC, Greenbelt, MD CLARREO SDT Meeting, NASA.
Page 1 Study of Sensor Inter-calibration Using CLARREO Jack Xiong, Jim Butler, and Steve Platnick NASA/GSFC, Greenbelt, MD with contributions from.
MCST – MODLAND Eric F. Vermote –MODLAND representative.
Pre-launch Characterization of the CERES Flight Model 5 (FM5) Instrument on NPP S. Thomas a, K. J. Priestley b, M. Shankar a, N. P. Smith a, M. G. Timcoe.
Scanner Characteristics
1 Calibration Adjustments for the MODIS Aqua 2015 Ocean Color Reprocessing Gerhard Meister, NASA Code 616 OBPG (Ocean Biology Processing Group) 5/18/2015.
Cross Validation of Thermal Infrared Remotely Sensed Data In-Flight Using Automated Validation Sites © 2010 California Institute of Technology. Government.
SeaDAS Training ~ NASA Ocean Biology Processing Group 1 Introduction to ocean color satellite calibration NASA Ocean Biology Processing Group Goddard Space.
SNPP VIIRS On-Orbit Calibration for Ocean Color Applications MODIS / VIIRS Science Team Meeting May 2015 Gene Eplee, Kevin Turpie, Gerhard Meister, and.
NASA, CGMS-41, July 2013 Coordination Group for Meteorological Satellites - CGMS Calibration/validation of Operational Instruments at NASA Langley Research.
Center for Satellite Applications and Research (STAR) Review 09 – 11 March 2010 Image: MODIS Land Group, NASA GSFC March 2000 Image: MODIS Land Group,
Residual correlations in the solar diffuser measurements of the MODIS Aqua ocean color bands to the sun yaw angle Presentation for SPIE meeting, August.
MODIS Aqua SDSM Gerhard Meister, presentation to CalVal, 2006.
ISPRS Gulfport Calibration Workshop December 3, 2003
MODIS Collection 6 MCST Proposed Changes to L1B. Page 2 Introduction MODIS Collection History –Collection 5 – Feb present –Collection 4 – Jan.
Implementation and Processing outline Processing Framework of VIIRS instrument monitoring System Processing Framework of VIIRS EV data Monitoring SD/SDSM.
Robert Wolfe NASA Goddard Space Flight Center Code 614.5, Greenbelt, MD Robert Wolfe NASA Goddard Space Flight Center Code 614.5,
VIIRS Product Evaluation at the Ocean PEATE Frederick S. Patt Gene C. Feldman IGARSS 2010 July 27, 2010.
MODIS Preprocessing (before L1B) Changes over the Last Year (and looking forward) Chris Moeller and others CIMSS; Univ. Wisconsin July 13, 2004 Thanks.
Polarization analysis in MODIS Gerhard Meister, Ewa Kwiatkowska, Bryan Franz, Chuck McClain Ocean Biology Processing Group 18 June 2008 Polarization Technology.
MODIS-Terra cross-calibration for ocean color bands Ewa Kwiatkowska Bryan Franz, Gerhard Meister, Gene Eplee OBPG 30 January 2008.
Use of the Moon as a calibration reference for NPP VIIRS Frederick S. Patt, Robert E. Eplee, Robert A. Barnes, Gerhard Meister(*) and James J. Butler NASA.
Collect 5 Calibration Issues Chris Moeller and others Univ. Wisconsin March 22, 2005.
Japan Meteorological Agency, June 2016 Coordination Group for Meteorological Satellites - CGMS Non-Meteorological Application for Himawari-8 Presented.
Page 1 NPOESS Preparatory Project (NPP) VIIRS Calibration Maneuvers May 15, 2008 Ocean PEATE Team.
MODIS-Terra cross-calibration for ocean color bands Ewa Kwiatkowska Bryan Franz, Gerhard Meister Ocean Biology Processing Group 13 May 2008 MODIS Science.
NASA NPP-SDS VCST NPP VIIRS On-Orbit Calibration Using the Moon J. Fulbright a, Z. Wang a, and X. Xiong b a SSAI (formerly with Sigma Space), Greenbelt,
2015 GSICS Annual Meeting, Deli India March 16~20, 2015 Xiuqing Hu National Satellite Meteorological Center, CMA Yupeng Wang, Wei Fang Changchun Institute.
ICVS Calibration and Processing Flow on S-NPP VIIRS 8/11/2016 Taeyoung (Jason) Choi, Ninghai Sun, Fuzhong Weng, Wanchun Chen, Lori Brown Page | 1 NOAA.
NOAA VIIRS Team GIRO Implementation 8/30/2016 Taeyoung (Jason) Choi, Xi Shao, Changyong Cao, Fuzhong Weng For Lunar Calibration Web Meeting.
Aqua-MODIS and VIIRS DCC calibration
CLARREO Pathfinder - Overview
PLEIADES Lunar Observations Sophie Lachérade, Bertrand Fougnie
MsWG (Apr 22, 2015) Recent L1B LUT delivery since April 8, 2015
Paper under review for JGR-Atmospheres …
NOAA VIIRS Team GIRO Implementation Updates
Aisheng Wua, Jack Xiongb & Changyong Caoc  
VIS/NIR reference instrument requirements
Extending DCC to other bands and DCC ray-matching
MODIS and VIIRS Reflective Solar Bands Calibration Methodologies and
The ROLO Lunar Calibration System Description and Current Status
GOES-16 ABI Lunar Data Preparation to GIRO
An Overview of MODIS Reflective Solar Bands Calibration and Performance Jack Xiong NASA / GSFC GRWG Web Meeting on Reference Instruments and Their Traceability.
NOAA Report on Satellite Data Calibration and Validation – Satellite Anomalies Presented to CGMS-43 Working Group 2 session, agenda item 3 Author: Weng.
Aqua MODIS Reflective Solar Bands (RSB)
Using SCIAMACHY to calibrate GEO imagers
AIRS (Atmospheric Infrared Sounder) Instrument Characteristics
Calibration and Performance MODIS Characterization Support Team (MCST)
MODIS Lunar Calibration Data Preparation and Results for GIRO Testing
MODIS Characterization and Support Team Presented By Truman Wilson
Using the Moon for Sensor Calibration Inter- comparisons
Characterizing DCC as invariant calibration target
Status of MODIS and VIIRS Reflective Solar Calibration
VIS/NIR sub-group discussion
Annual GSICS Calibration Report for {Agency}
S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS) Lunar Calibration using GSICS Implementation of the ROLO model (GIRO) for Reflective Solar Bands.
MODIS L1B Data Product Uncertainty Index Jack Xiong (Xiaoxiong
Launch and On-orbit Checkout
Current Status of ROLO and Future Development
Consistent calibration of VIRR onboard FY-3A to FY-3C
Strawman Plan for Inter-Calibration of Solar Channels
Spectral Correction for Inter-comparion between VIIRS and MODIS TEB
Shanghai Institute of Technical Physics , Chinese Academy of Science
GSICS Annual Meeting March 06, 2019 Frascati, Italy
goes-16/17 abi lunar calibration
Andrew Heidinger JPSS Cloud Team Lead
Presentation transcript:

Lessons from MODIS Calibration and Characterization Xiaoxiong (Jack) Xiong NASA Goddard Space Flight Center (GSFC) Acknowledgements: MODIS Characterization Support Team (MCST) NPP Instrument Calibration Support Team/Element (NICST/E) GSICS Joint Research and Data Working Group Meeting, NSMC, CMA, Beijing, China (March 5-8, 2012)

Examples presented at AMS 92nd Annual Meeting, New Orleans, LA, 2012 Outline Introduction MODIS Calibration and Characterization Pre-launch and on-orbit Performance Overview Lessons Terra MODIS to Aqua MODIS MODIS to other sensors (e.g. VIIRS, ABI) Summary Examples presented at AMS 92nd Annual Meeting, New Orleans, LA, 2012 Paper: 18SATMET 5B.4 Page 2

Introduction Moderate Resolution Imaging Spectroradiometer (MODIS) Developed based on the requirements from the science community for the NASA’s EOS missions Designed with improvements over heritage sensors, such as AVHRR, CZCS, HIRS, and Landsat TM Built by Raytheon Santa Barbara Remote Sensing (SBRS) Managed and operated by NASA GSFC NPP VIIRS built with strong heritage to MODIS Benefits from Lessons Design and performance Science applications Schedule and cost AMS in Jan 2012 CALCON in Aug 2012 Page 3

MODIS Calibration and Characterization MODIS Calibration Program or Approach Pre-launch Project and Science Team CVWG (Calibration and Validation Working Group) Sensor Vendor Government Led Calibration Support Team On-orbit Science Team Disciplinary Cal/Val scientists MsWG (MODIS sensor Working Group) Page 4

Pre-launch Calibration and Characterization Solar Reflective Regions Radiometric Calibration source: SIS-100 (NIST traceable) at multiple radiance levels (lamp configurations) Calibration parameters: gain, nonlinearity, SNR, dynamic range, gain dependence on the instrument temperatures Three instrument temperatures for thermal vacuum test Primary and redundant electronics Solar diffuser BRDF calibration (NIST traceable) Others (all system level) Spectral: relative spectral response (RSR) Spatial: pointing, band-to-band registration (BBR) Response versus scan angle (RVS) Polarization sensitivity “Similar” calibration activities thermal emissive calibration Page 5

On-orbit Operation and Calibration SRCA: Radiometric: monthly Spatial: bi-monthly Spectral: quarterly SD/SDSM: Weekly to tri-weekly Solar Diffuser SRCA SDSM Blackbody Scan Mirror Space View BB: quarterly Spacecraft maneuvers: Yaw (SD BRF, VF) Roll (Moon) Pitch (only applied to Terra) Moon: monthly (nighttime orbits) 0-20o spacecraft roll maneuvers 55o phase angle Page 6

Performance Overview Sensor and OBC Operation and Performance Instrument and focal plane Blackbody and solar diffuser Radiometric Reflective solar bands Thermal Emissive bands Spatial BBR in along-scan and along track directions Spectral Reflective spectral response (CW, BW) Page 7

Instrument Temperatures Terra MODIS: less than 3.5 K increase over 12 years Aqua MODIS: less than 2.0 K increase over 9 years Similar trends for the VIS and NIR FPA temperatures Page 8

Cold Focal Plane Assembly (FPA) Temperatures Terra MODIS: SMIR LWIR Aqua MODIS: SMIR LWIR Small increase of CFPA temperatures in recent years (0.4K) No impact on TEB scan-by-scan calibration Page 9

Blackbody Temperatures (nominal operation) Terra MODIS: less than 30 mK increase over 12 years B-Side Aqua MODIS: extremely stable On-board BB used for Thermal Emissive Bands (TEB) calibration Page 10

Solar Diffuser (SD) Degradation Larger degradation at shorter l Increased SD degradation due to SD door fixed at “open” Terra MODIS Further reduction of Aqua MODIS SD calibration frequency to be considered Aqua MODIS On-board SD used for Reflective Solar Bands (RSB) calibration Page 11

Reflective Solar Band Responses (VIS) Band Averaged, Mirror Side 1 Larger changes at shorter l Terra MODIS Terra/Aqua difference, wavelength, AOI and mirror side dependent Page 12

Lessons Calibration team (e.g. MCST), in support of science team and project, needs to work closely with instrument vendor (e.g., SBRS) pre-launch calibration and characterization Calibration team needs to work closely with science team Early post-launch performance assessment Vicarious calibration and validation effort Calibration effort needs to be sustained over the entire mission Track and correct sensor on-orbit changes or degradation, especially as instrument gets “older” Documentation and test data records Operation Concept Document (OCD), ATBD, User Guide Test data/reports, technical memos, conference /journal papers Page 13

Lessons Pre-launch Calibration On-orbit Calibration Perform a complete/comprehensive set of calibration and characterization (different levels and phases) Eliminate “undesirable features” if possible, otherwise, fully characterize them Test as it flies (End-to-End test) On-orbit Calibration Calibrate with different approaches and methodologies (OBC and ground targets, calibration inter-comparisons) Establish, review, and update sensor operation and calibration procedures Expect the “unexpected” Calibrate, calibrate, and calibrate, … Page 14

Lessons Terra MODIS to Aqua MODIS MODIS to NPP VIIRS Eliminated PC optical leak Reduced SWIR thermal leak and electronic crosstalk Performed TEB response versus scan-angle (RVS) characterization MODIS to NPP VIIRS Improved SD attenuation screen (block earthshine) Improved SDSM design (eliminated design error in MODIS SDSM) Performed SD screen and SDSM screen transmission characterization Experimented with the E2E RSB calibration Improved polarization characterization Test data analysis tools and calibration methodologies Page 15

No PC optical leak in Aqua MODIS PC Bands Optical Leak Terra B35 Before correction After correction Aqua B35 No PC optical leak in Aqua MODIS Page 16

Comparison of Terra and Aqua MODIS Surface Reflectance Product Bands 1, 2, 3 (RGB) Band 7 (2.1mm) Aerosol Optical Depth Terra MODIS Aqua MODIS Smaller Xtalk, More Effective Correction, and Better Performance in A-MODIS Page 17

TEB RVS Characterization (Terra versus Aqua MODIS) Terra (South Pacific 2000073.0730) 1 2 Pre-launch RVS On-orbit RVS Area 1 Area 2 Area 1 Area 2 Aqua (Baja, CA 2002194.2050) 3 4 1 2 Pre-launch RVS Area 1 Area 2 Area 3 Area 4 Page 18

Improved Design of VIIRS SDSM Large ripples in MODIS SDSM Sun View responses were due to a design error MODIS SDSM design error was eliminated in VIIRS (thus better performance) MODIS SDSM SD View Responses VIIRS SDSM SD View Responses Page 19

VIIRS/MODIS SNO Reflectance Trends (2011-11-21 to 2012-01-16) VIIRS and MODIS reflectance ratio trends are derived from a number of SNO events (MODIS C5 LUT with VIIRS LUT V1.5.5.0) VIIRS VIS/NIR spectral response degradations (%) over the trending period (relative to Aqua MODIS) I1 I2 M1 M2 -2.3 -13.5 1.8 1.7 M3 M4 M5 M7 1.0 -0.9 -3.3 -14.0 Normalized VIIRS-to-MODIS reflectance ratios VIIRS NIR degradation (especially in M7, I2, M6, and M5) Methodologies and tools developed for MODIS supported VIIRS NIR degradation anomaly investigations Page 20

Summary An overview of MODIS operation and calibration Calibration activities Examples of instrument performance Lessons from MODIS calibration Dedicated Calibration Team Sustained calibration effort Comprehensive pre-launch and continuous on-orbit calibration Importance of documentation and data records Benefits from MODIS lessons to future sensors Improved design with better overall performance Calibration experience (methodologies and tools) Calibration results (reference) Page 21

Instrument Performance Summary (1) Both instruments continue to operate normally Changes of instrument and warm FPA temperatures are less than 3.5K for Terra MODIS over 11 years; less than 2K for Aqua MODIS over 9 years Terra MODIS cold FPA temperatures remain stably controlled at 83K Gradual decrease of Aqua MODIS cooler margin has led to small increase (up to 0.30K), orbit-to-orbit and seasonal variations of its cold FPA temperatures A workshop on Aqua MODIS CFPA performance and operation was held on May 7, 2010 (decision reached to maintain current operational configuration unless there is an evidence that the current CFPA performance has a negative impact on science data product quality) All on-board calibrators continue to provide key design functions BB temperatures remain extremely stable for both Terra and Aqua MODIS, short- and long-term Terra MODIS SD door has permanently fixed at the “open” position since July 2, 2003, which has led to increased SD degradation rates Page 22

Instrument Performance Summary (2) Radiometric (36 spectral bands with 490 individual detectors) There are no new noisy and inoperable detectors since last STM 45 noisy detectors (30 from pre-launch; 35 at launch) and no inoperable detectors for Terra MODIS 6 noisy detectors (2 from pre-launch; 3 at launch) and 15 inoperable detectors (13 in band 6) for Aqua MODIS Spectral (VIS/NIR bands only) Changes in center wavelengths and bandwidths are less than 0.5 and 1.0 nm, respectively, for most spectral bands (only a few exceptions) Spatial (all bands) On-orbit band-to-band registrations (BBR) have been stable for both Terra and Aqua MODIS Large BBR offsets in Aqua MODIS between cold FPA and warm FPA band pairs (a known problem since pre-launch) Page 23