HEMATOLOGY WHAT IT IS : Study & measurement of individual elements of Blood. WHAT IT’S COMPOSED OF. SHOW SLIDES FROM PERIPHERAL BLOOD TUTOR CD OR USE PLATE.
BLOOD PRACTICAL RBC, WBC, HB & PCV.
Analytic Phase of Laboratory Testing
Automating Result Verification
Complete Blood Count ( CBC). Complete Blood Count ( CBC)
MLAB 1415: Hematology Micros 60.
Introduction to Instruments
Automated CBC Parameters Quality Control
Automated Hematology Cell Counters
Tool removed during cycle Fault #2 Conditions for setting Tool cocked prox switch goes open during cycle AND force on load cell drops below limit in fault.
Simple Accurate Reliable Economical. M Series Platforms 16 Parameter, 3 Part Differential Systems  Open Tube Sampling  Closed Sampling  Automated Sampling.
Electrical Impedance and Colorimetric Measurements Joanna Ellis, MLS(ASCP)
Automated Hematology Cell Counters
Automation in hematology Until Slide 23
-Automation blood count -Red and White blood count and differential count (Manual blood count) Prepared by: Mona alharbi Experiment:
The Complete Blood Count
Quality Assurance / Quality Control
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
-Automation blood count -Red and White blood count and differential count (Manual blood count) Experiment:
Objectives 1. Methods used to measure the different hematological values, and compare it with the normal values. 2. The calculation of RBC indices, their.
A compact 5-diff solution
Agile - affordable - accurate. Hematology, is the part of internal medicine, that is concerned with the study of blood, the blood-forming organs, and.
Analyticon Biotechnologies AG
Clinical Haematology & Cell Counting
CLS 541-Advanced Medical Haematology M. sc. Program Lab-2-
Automated CBC Parameters Quality Control
Automation in haematology
Automated CBC Parameters
Automated CBC Parameters
Complete Blood Count.
THE BASIS OF HEMATOLOGICAL DIAGNOSTICS Marustchak M.I.
Clinical pathology: Complete Blood count
Microscope parts:.
Microhematocrit Determination. Microhematocrit Hematocrit — Test that provides a health care worker with an estimate of the patient’s red cell volume.
Preparing a Blood Smear. Samples for Hematology Capillary blood and venous blood can be used for hematology tests. Capillary blood is beneficial if a.
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
HAEMATOLOGY LINE A.C.KAROBIA
Quality Management in Hematology Laboratory.
Flags, Codes and Messages on the COULTER® LH 750/755
Blood Testing. Learning Objective  To identify the types of tests performed on blood  To explain why these tests are useful  To discover the normal.
Heamatology The diagnosis, treatment, and prevention of diseases of the blood and bone marrow as well as of the (blood clotting) and vascular systems.
NORMA ICON. INTRODUCTION - ICON Point of care ready Small footprint Smallest sample volume and lowest reagent consumption in the world Microfluidic components.
Freestyle Precision Pro
Electrical Impedance and Colorimetric Measurements
Automatic Electronic Blood Cell Counting
ABX Pentra DF 120 Flexible hematology platform For internal use only
Other Hematological Procedures
Unit #6 - Basic Quality Control for the Clinical Laboratory
Automated Hematology Cell Counters
EVALUATION OF HEMOCHROMA POC Hb READER
International Operations
(待機画面) © 2007 HORIBA, Ltd. All rights reserved..
PENTRA 60 C +.
Product specification
Patient A.
پراكندگي تالاسمي در جهان بيماري تالاسمي در سراسر جهان و در همه نژادها ديده مي‌شود ولي شيوع آن در نواحي مديترانه (ايتاليا, يونان , قبرس)‌خاورميانه (ايران,
Process control in Hematology section
Supplementary Figure S7
Digital Chart Recorder Operation
MEK-6400 series Technical seminar
CELL-DYN 1700/1800 Software Training Simulation
Quality Control Lecture 3
Piccolo Xpress™ Moderately Complex Training Demonstration
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Complete Blood Count (CBC)
Checkpoint kinase 1 is essential for fetal and adult hematopoiesis
Presentation transcript:

Micros 60 & Quality Control MLAB 1415: Hematology Micros 60 & Quality Control

CBC Quality Control Commercial Controls: 3 levels (low, normal, high) Values stored in instrument computer Levey-Jennings graph generated and stored for each parameter Mode to Mode QC: Most automated hematology instruments have a primary and secondary mode of sample aspiration. Controls must be run on BOTH and correlate. Primary=Automated or Closed Secondary=Manual or Open Delta Checks When the Laboratory Information System (LIS) and the instrument are interfaced (connected) delta checks are conducted by the LIS on select parameters. Current values compared to most previous result Differences greater than the limits set within the LIS are flagged

Micros 60 3-part differential Sample size= 10µL Environment Indoor only Level work station Avoid direct exposure to sunlight Proper ventilation 60-90oF Linearity (AMR) WBC (103/mm3): 0-100 RBC (106/mm3): 0-8.0 Hgb (g/dL): 2.0-27 Hct (%): 1.8-82.3 Plt (103/mm3): 25-4990

Linearity (Reportable Range/ AMR) Instruments are calibrated for each analyte with a range that is clinically relevant. With concentrations above or below the reportable range or Linearity range, the result does not correspond with the calibration curve in linear fashion. Results outside of linearity are NOT acceptable. Linearity ranges vary by instrument. Example: Parameter Coulter STKS Advia WBC 0.0 -99.9 X 103 /µL 0.02-400 X 103 /µL

Parameters Parameters Measurements/Calculations WBC/RBC/PLT Hgb Hct MCV MCH MCHC RDW Platelet MPV Lym # Lym% Mono # Mono% Gra# Gra% WBC/RBC/PLT Impedance change HGB Spectrophotometry LYM%/MON%/GRA% Calculations MCV, MCH,MCHC,RDW,MPV,LYM#, MON#, GRA#

Automation Specs Principle of operation: The counting principle used for the red blood cells, white blood cells and platelets is based on the variations in impedance generated by the passage of cells through a calibrated aperture. Number of samples which can be analyzed per hour: 60 Number of tests performed on this analyzer: 1 Quality control: Three levels run each day of patient testing, or following instrument repair, reagent lot change, or when indicated. Calibration: Shift in control values, replacement of instrument parts, reagent number change, or when indicated Preventative maintenance: Daily: start up and shut down, general cleaning Acceptable samples: whole blood from an EDTA tube ran within 4 hours of collection Limitations: Lipemia, cold agglutinins, high WBC’s

Equipment 8 Main parts Electrical supply Electronic board Dilution pneumatics Control panel with keyboard and LCD screen Reagent compartment Printer Smart card reader Bar code reader (optional)

Reagents Waste Diluent Cleaner LYSE: potassium cyanide ABX minidil: sodium hydroxide/azide Determines and differenciates blood cells Cleaner ABX miniclean: enzymatic detergent Cleans system LYSE: potassium cyanide ABX Alphalyse: Lyses RBCs, releasing hemoglobin and WBCs. WBCs are counted by impedance. Waste

Distribution curves WBC RBC Plt

Daily Start Up Turn on instrument, once on, the start-up will begin automatically Instrument is performing a cleaning and rinsing cycle: detergent in the chamber is rinsed with diluent Cycle lasts about 130 seconds At cycle completion, background values will be displayed. These values must be less than the below: WBC < 0.3 x 103/mm3 RBC < 0.02 x 106/mm3 Hgb < 0.0 g/dL Plt < 10x 103/ mm3 If the values are not within this range, another cycle will begin. If still not in range, the Micros will do another start-up. After 3 failed cycles, it will give a “start-up failed” message. Troubleshooting will now start.

Daily start-up con’t Run a primer sample Perform QC and evaluate Complete maintenance sheet If all QC in, can continue with patient samples.

Running a Patient Press the ID button on the key pad Manually enter the ID. Use the up and down arrows to enter alphabetical characters. Please Enter after each entry.

Shutdown Hit the Stand by key, wait 1 minute Switch off instrument and printer. When the shutdown hit is pressed, the Micros 60 performs a complete cleaning with the Miniclean and puts the system into a Standby mode. Once this process is complete, the instrument can be switched off.