12.06.2017.

Slides:



Advertisements
Similar presentations
Museum Presentation Intermuseum Conservation Association.
Advertisements

TITAN Group …….Managing Site Build up for the telecom sector TICS Telecom Projects Consultancy Pvt. Ltd.
Course Material Overview of Process Safety Compliance with Standards
Disaster Planning What Supervisors Need to Know. Session Objectives You will be able to: Recognize the types of workplace disasters you may face Understand.
Developed by Western Iowa Tech Community College This material was produced under a grant (SH F-19) from the Occupational Safety and Health.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration U.S. Department of Transportation Pipeline and Hazardous Materials.
GENERAL DIRECTORATE FIRE SAFETY AND CIVIL PROTECTION
HAZ COM An employer must assemble information on the hazards of the chemicals they use. (Most will get this data from their chemical suppliers who are.
Helfried Rybin 1 AUTOMOBILENTWICKLUNG / ENGINEERING Safety Demands for Automotive Hydrogen Storage Systems Helfried Rybin.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Risk Consulting REVISION TO EN and CEA 4001 EFSN – MAY 2014.
N A managed approach to planning and controlling the implementation of complex application software. n A flexible tool kit, designed to support the Project.
CLINICAL ENGINEERING part(3) Dr. Dalia H. Elkamchouchi.
ABC Chemical Complex1 Maintenance of DOT Regulated Valves ABC Company ABC Chemical Complex Engineering Specification.
Mower Safety begins with the Operator!. TMLIRP Mower Safety2 The US Consumer Product Safety Commission has reported there are more than 60,000 injuries.
1 WELCOME TO Electrical Safety Arc Flash/Blast Injury Prevention Management/Supervisory Course.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Harold Winnie, CATS Manager (Central Region) Leak detection for.
Process Safety Management
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
Levels of safety Priorities for eliminating hazards in the workplace Eliminate the hazard through the machine design stage Apply safeguarding technology.
Means of Egress and Fire Protection
WHAT IS SYSTEM SAFETY? The field of safety analysis in which systems are evaluated using a number of different techniques to improve safety. There are.
Brussels, 4 June 2010 Introduction I. HOTREC – an umbrella II. HOTREC Fire safety Project.
Slide 7-1 UNIT 7 POST INCIDENT EVALUATION AND ANALYSIS.
What Is Smart Home It should use computers Integrate work, learning and living into home It should hide the technique and details of how it works.
By: Caleb Harris.  The main purpose of QA is to monitor programs to determine their effectiveness, and if they are ineffective, to implement appropriate.
HOUSTON, TEXAS1 Maintenance of DOT Regulated Valves ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
Accident Prevention Manual for Business & Industry: Engineering & Technology 13th edition National Safety Council Compiled by Dr. S.D. Allen Iske, Associate.
Household Hazardous Waste. Hazardous waste in our house?! We all use many solvents and solutions at home because they help with cleaning, polishing, painting,
Pressure Systems: Users Guide Introduction This guidance note summarises the key features of the Pressure Systems Safety Regulations (PSSR). Theses Regulations.
Fire Safety and Emergencies
New Aerial Lift Standards Getting Close To Completion
1 Regulatory Reform (Fire Safety) Order 2005: An Insurer’s View Mark Newton Property Technical Manager Royal & Sunalliance Insurance.
© BLR ® —Business & Legal Resources 1603 Disaster Planning What Supervisors Need to Know.
NFPA Codes and Standards Contents 01 Introduction Who is the NFPA Making of NFPA Code or Standard 02 Development Process The Codes and Standards.
PUBLIC HEARING PROCESS AND REVIEW FOR THE PROPOSED ADOPTION OF THE 2012 INTERNATIONAL CODES AND THE 2014 NATIONAL ELECTRICAL CODE.
April 28, 2016 Hockley Valley, Ontario
PERSONAL SAFETY INTERLOCKS External EHS Expert Panel Workshop
Emergency Stair Travel Devices used by Individuals with Disabilities
Safety Instrumented Systems
آشنايي با ضوابط خدمات پس از فروش
An Integrated Risk Management & Safety Program: IRMSP
NICET Fire Alarm Tech Level 1 Practice Test
Document 7/ Memorandum of Understanding (MOU)
Maintenance of DOT Regulated Valves
Applying Preventative Maintenance Practices
Safety Instrumented Systems
Flooding Walkdown Guidance
Projects Integrating Planning for Successful Occupancy, Operation, and Maintenance into your Capital Project.
EXTINGUISHER TRAINING Presented by: Dan Klimek Sisk & Company.
Emergency Electrical Power Supply for Buildings
M&E SYSTEM.
Maintenance Apart from safety, maintenance is needed to keep plant in an acceptable condition. Maintenance of this kind must be reviewed on an economic.
Chemical Safety and Security Plan
Risk Management and Mitigation
Safety and Accident Prevention
HIPAA Security Standards Final Rule
(name) (number) Hazard Analysis and Risk Assessment Operations
FACILITY DOCUMENT REVIEW TRAINING
VDMA-Database Machinery safety standards | Hilmar Schmieding.
PSS0 Design & Concept of Operations
installations and assemblies
Parker domnick hunter. Safety of Electrical and
ESHAC #8 Safety Readiness Review Thomas Hansson, ESH
Eltronic A/S Engineers 50 Engineers
Staying legal: Machinery Safety and Visibility
Council Orientation October 24, 2017
ABC Company ABC Chemical Complex Engineering Specification
Maintenance of DOT Regulated Valves
Presentation transcript:

12.06.2017

Requirements / Design / Operation DIN 14097 Firefighter Training Facilities a comparison of existing and New draft 12.06.2017

DIN 14097 = Firefighter Training Facilities General Information: DIN 14097 = Firefighter Training Facilities As per DIN rules and procedures each standard will be reviewed 5 years within the DIN committee If a standard no longer reflects the current state of technology, it is either revised or withdrawn. DIN committee appoints a working group to review Working group consist of fire fighters, engineers, HS-insurance, manufacturers 12.06.2017

General Information: DIN 14097 DIN 14097 is not a European Standard (CEN) nor International Standard (ISO) DIN 14097 is developed to allow architects, engineers, firefighters and administration to design, build and operate training facilities for firefighters and first responders Whenever DIN 14097 requirements are mentioned everyone knows what needs to be accomplished 12.06.2017

DIN 14097 Comparison DIN 14097 existing DIN 14097 new draft Parts: Part 1 General Requirements Part 2 Gas-Fuelled Simulation Devices Part 3 Wood-Fired Training Facillities Part 4 Firefighter Training Houses Parts: Part 1 General Requirements Part 2 Gas-Fuelled Simulation Devices Part 3 Wood-Fired Training Facillities Part 5 Liquid-Fuelled Simulation Devices 12.06.2017

DIN 14097 Comparison DIN 14097 existing DIN 14097 draft Part 1: Mainly related to a training building Very detailed building requirements Detailed requirements for the simulation equipment Operational requirements Acceptance and maintenance requirements Part 1: More generic with room for individual design Definition added: Training Facility Simulation Devices Simulation Objects Training Grounds Training Rooms Training Objects Clarification added 12.06.2017

DIN 14097 Comparison DIN 14097 existing DIN 14097 draft Part 1: Information for use of installation Part 1: Operational concept required Detailed requirements User Manual Emergency plan Warning notes Safety requirements 12.06.2017

DIN 14097 Comparison DIN 14097 existing DIN 14097 draft Part 2 Gas Fuelled: Explosion protection and prevention Part 2 Gas Fuelled: Explosion protection and prevention Now also requirements on installation / pipework (gas tight) Use of different gases Gas in liquid phase is not allowed in close training environments Testing of equipment In accordance with §15 / § 16 BetrSichV 12.06.2017

DIN 14097 Comparison DIN 14097 existing DIN 14097 draft Part 3 Wood-fired: Explosion protection and prevention No differentiation of systems Alarm Device Cable activiated Part 3 Wood-fired: Differentiation between Simulation without increasing pressure Simulation with significant increasing pressure Design should be cavity free! Berlin accident! Alarm device More simplified system 12.06.2017

DIN 14097 Comparison DIN 14097 existing DIN 14097 draft Part 4 Training houses: Part 4 NOT Existing: Part 4 is now partially integrated into part 1 12.06.2017

DIN 14097 Comparison DIN 14097 existing DIN 14097 draft Part 5 Not existing: Part 5 Liquid Fueled: New part! Definition of liquid fuels Only in outdoor areas Pressure fed only Owner is responsible for safety analysis 12.06.2017

Next Steps: DIN 14097 Draft presented to the DIN committee Draft (Yellow Print) will be presented to the public in July 2017 Presentation and discussion on objections scheduled for Q4 2017 Final version will be available early 2018 12.06.2017

Platform for a new Perspective! Questions? 12.06.2017