HD SIGNAL CONDITIONER SERIES

Slides:



Advertisements
Similar presentations
MEGATRON. Privately owned shares company founded at The company is engaged in manufacturing Measu- rement, Monitoring and Control equipment. Megatron's.
Advertisements

Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
1 ■ RTD INPUT 2 or 3 wire RTD ’ S input sensing : 2mA DC(pt) MODEL & SUFFIX CODE HD-GPMA MODEL ORDERING INFORMATION Specify code number and variables *
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
1 5A 200A 6600V HOW TO DETERMINE LIE WATTAGE... WATT The standard voltage rating is 110V, the standard current rating is 5A, the transducer range is 1000W.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
Troubleshoot The AC Circuitry
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Controller Wiring.
Common Equipment 2 : DC power Supply Common Equipment 2 : DC power Supply ---MODEL LPS-305 Motech.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
1 INPUT & OUTPUT ■ INPUT * Voltage Side ( PT side ) Operational range : 0-110% Permissible over range : 150% for 10 seconds 120% continuously * Current.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
1 Chang Shuan Eletronics Co., Ltd
Controls and Electrical Preferred Technologies Steve Pavis PH-DT-DI CERN Advel Power Supplies and ABB Circuit Breakers.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
Product Specification of Power Supply Unit Specification TitleSMP Global’s Savvy 42S Revision Ver. 02A 06/SEPTEMBER/2005 Page 1/22 Buyer Name Model Name.
Merkmale SITRANS T Automation and Drives Process Instrumentation and Analytics Common Technical Data (1) Technical Data (2) Features Block Diagram Housings.
1 SPECIFICATION Power : DC 24V ± 5% Input Signal : RS – 485 SERIAL Display: 4 DIGIT LED (H:10.16mm) Address Selection : POWER TO INPUT Isolation: POWER.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Remote AI (Add 6 inputs/units, Max 48 inputs/recorder) VM7000A RS-485(Max 1200m) Remote AI (Max: 6 units) Recorder 12 CH Remote AI 6CH x 6units TTL: 48.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
1 Chang Shuan Electronics Co., Ltd
Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
7 Programmable DC Power Supply EPS Series ■ Features & Benefits * Linear type power supply * Easy to control voltage & current with jog shuttle * 4-Digit.
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
SITRANS T3K PA Field Instruments Process Instrumentation and Analytics Technical Data (1) Technical Data (2) Features Block Diagram SITRANS T3K PA Head.
Power Electronics and Switch Mode Power Supply
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
WavePak DC/DC Isolator / Converter. Essential facts Scalable I/O ranges “Lite” version of Wave PRO DC/DC Selectable Active or Passive input 24Vdc to power.
SPECIFICATION FOR APPROVAL ( PB-FREE APPLICATION ) CUSTOMER:BERESEE Co., Ltd ITEM: POWER SUPPLY UNIT (for 37” ~ 42 ” HD MNT) DESCRIPTION:260W BUILT-IN.
SPD II 1 for LV Power (AC/DC)
Automatic Door System Sliding Operator SD-60A2 Specification 1.
CHAPTER 6 VOLTAGE REGULATOR Tulus Ikhsan Nasution.
HD POWER TRANSDUCER SERIES
ABB i-bus® KNX Valve Drive Actuator VAA/A
음향 시스템 사양서 POWER SUPLY WITH 3.5 PHOENIX CONNECTOR AMX: PSN6.5
HD POWER TRANSDUCER SERIES VOLT-DEMAND TRANSDUCER
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
General wiring drawing /
Intelligent controller with Microprocessor Incorporated NPS6220
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
Newton-500 Series CAS Corporation CAS Marketing Team.
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
HD POWER TRANSDUCER SERIES
HD POWER TRANSDUCER SERIES
POWER AMPLIFIERS E 5:4 LAB.GRUPPEN NAME MODEL 제조사 General
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
HVI HIPOT TEST SET Pft sERIES.
Analog Room Command Module
NSA-7000 Stylish flush mount Network Sensors
User Manual 1 2a 2b A. Introduction This product is a battery-powered, true-rms, auto-ranging digital multimeter.
MicroLogix Packaged Controllers
Chapter 6: Voltage Regulator
Customer Presentation
Customer Presentation
HD POWER TRANSDUCER SERIES
HD SIGNAL CONDITIONER SERIES
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
easYgen-3000XT Series Training
TAL227 PARALLEL BEAM LOAD CELL
Lecture 2 Electrical and Electronics Circuits. After you study, and apply ideas in this Lecture, you will: Understand differences among resistance, capacitance,
Presentation transcript:

HD SIGNAL CONDITIONER SERIES RTD TRANSMITTER MODEL HD-RTD MODEL & SUFFIX CODE SELECTION MODEL HD-RTD Input signal Output1 signal GENERAL SPECIFICATIONS Output2 signal Construction : plug-in Connection : M3.5 screw terminals Housing material : flame-resistant resin (black) Isolation : input to output to power (non-isolated between I/O) LCD meter : indicating input; 0.1% increments Overrange output : approx. -10 - +120% at 1 - 5V Front adjustments : zero and span ; 5% Burnout protection : upscale standard; downscale optional Linearization : standard Availability as Output1 N:None Display A:Percent B:Input signal C:Output signal O:Others N:None INPUT & OUTPUT INPUT : 2- or 3-wire RTDs Maximum leadwire resistance : 200 per wire (3-wire) Sensing current : 2mA (Pt) Temperature range Power X:110V AC Y:220V AC Z:24V DC O:Others ORDERING INFORMATION Specify code number and variables. Code number : ex) HD-RTD-4AANY Temperature range (e.g. 0 - 500℃) Special input and output ranges : code:0 A : -10 ~ 20mA V : 0 ~ 15V

(INPUT to OUTPUT to GROUND) DC Current : 0 - 20mA DC Minimum span : 1mA Zero suppression/elevation : max. 1.5 times span Load resistance Output Load Resistance 4 - 20mA : 750 ( maximum) 2 - 10mA : 1500 1 - 5mA : 3000 0 - 20mA : 750 0 - 16mA : 900 0 - 10mA : 1500 0 - 1mA : 15k DC Voltage : -10 - +12V DC Minimum span : 5mV Load resistance : output drive 10mA maximum; 5mA for negative voltage output; at 0.5V Output Load Resistance 0 - 10mV : 10k ( minimum) 0 - 100mV : 100k 0 - 1V : 100 0 - 10V : 1000 0 - 5V : 500 1 - 5V : 500 INSTALLATION Power input AC : rating 10%, 50/60 2 Hz, approx. 2VA DC : rating 10% , or 85 - 150V for 110V rating (ripple 10% p-p max.) approx. 2W (80mA at 24V) Operating temperature : -5 to +60℃ (23 to 140℉) Operating humidity : 30 to 90% RH (non-condensing) Mounting : surface or DIN rail Dimensions : W50  H80  D123 mm See General Spec. Sheet Page B-1. Weight : Terminal assignment : See General Spec. Sheet Page B-1. PERFORMANCE in percentage of span Accuracy : 0.2% Temp. coefficient : 0.015%/℃ (0.008%/℉) Ripple : 0.25% p-p max. (100/120Hz) Response time : 0.4(400ms) seconds (0 - 90%) approx. 25 milliseconds with option Burnout response : 10 seconds Line voltage effect : 0.1% over voltage range Insulation resistance : 100MΩ with 500V DC Dielectric strength : 1500V AC @1 minute (RB : input or output to power to ground) (RBS : input to output to power to ground) Common mode voltage : 30V RMS (CSA) Surge withstand Voltage : 1.2/50sec, 5KV (INPUT to OUTPUT to GROUND) SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM