«TENSY GROUP» Moscow, Russia

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

Beckett Energy Systems
PowerPoint ® Presentation Chapter 4 System Components and Configurations Components Electricity Sources System Configurations.
Uninterruptible Power Supply (UPS)
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
Rooftop Solar Systems Rooftop Solar System (Off-Grid) Reliance Solar Energy™, Ratnagiri.
Professor Sung-Yeul Park
Switched-Mode DC Power Supplies Five configurations –Flyback –Forward –Push-pull –Half Bridge –Full-Bridge Operate at high frequencies –Easy to filter.
Application of Power Electronics
NEW ARRIVAL POWER ELEKTRO MEGIC BOX POWER ELEKTRO ENGINEERING COMPANY (PVT) LIMITED.
IPS Rev 1.0 Ken Lutz University of California, Berkeley
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
POWER SUPPILES LECTURE 20.
GestEnergy48V Energy Autonomy.  How work during the day or with cloudy time The inverter supplie electric power, through the photovoltaic panels and.
POWER SEMICONDUCTOR SYSTEMS II Author: Ales Havel Phone number: 4287 Headquarters: E227 Web page:
Power Semiconductor Systems II
Freedom Combi Inverter
1 © Alexis Kwasinski, 2012 Introduction Field Excitation Q Synchronous generators Input: Mechanical power applied to the rotor shaft Field excitation to.
Off-Grid Power Using Enphase Micro-Inverters Off-grid inverter systems, using batteries, can be used to provide AC power when the grid is down. It is possible.
Renewable Energy as Priority
SUPR E-Harv Model Simulations Chuhong Duan ECE Department, University of Virginia 07/31/2012.
Lesson 9: Electrical Components
Performance modeling of a hybrid Diesel generator-Battery hybrid system Central University of Technology Energy Postgraduate Conference 2013.
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
Power Conditioners and Uninterruptible Power Supplies
Solar-Powered Fuel Stations
Power Quality Assessment on Wind Energy systems Presented By vivek kumar(pe610)
Motors and Generators.
650 VA Power Tree UPS 650VA 100% Stabilized Output Power
ENERGY: PHONE CHARGER Input, Output, Process, Feedback.
Basic Equipment and Schematic Reading. Objectives Learn the basic equipment that will be used in the Lab. Learn some of the basic symbols used on electrical.
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
LP Series 400V CE GE Consumer & Industrial September 2004.
Powered by the Sun, Sustainable through Quality. Who is Suncolect Suncolect provides Solar electricity solutions to entrepreneurs in small, medium and.
Switch Mode Power Supply(SMPS) BY: Arijit Acharya NETAJI SUBHASH ENGINEERING COLLEGE M.tech(P.S.) Roll No - 1.
Abbott Technologies Presents DC To AC Inverters. DC To AC Power Inverters change direct current (DC) to Alternating current (AC).
PRESENTED BY SUDHEESH.S PS-B-12. CONTENTS  INDTRODUCTION  WIND POWER EXTRACTION WITH BATTERIES  CONTROL SCHEME  SYSTEM PERFORMANCE  RESULTS  CONCLUSION.
Renewable Energy Systems David Buchla | Thomas Kissell | Thomas Floyd Copyright © 2015 by Pearson Education, Inc. All Rights Reserved Buchla, Kissell,
SIZING OF ENERGY STORAGE FOR MICROGRID
© ABB Group October 1, 2016 | Slide 1 DynaPeaQ ® SVC Light ® with Energy Storage FACTS.
DIGITAL MULTIMETER DMG
System types. System types System types Off-grid No grid available. Use battery as a buffer, buffering solar energy and/or energy coming from a genset.
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
UPS Training: The Online UPS
Uninterruptible Power Supply (UPS)
Chapter 3 Power Electronic Circuits
Eric A Lewis Enstore director
Rectifiers, Inverters & Motor Drives
A Project Review On POWER QUALITY IMPROVEMENT IN GRID USING STATECOM
What is ASEMR /ASKUE/ and the Need for Its Implementation
Switch-Mode DC-AC Inverters
Photovoltaic Systems Engineering Electronic Control Devices (ECDs)
Islamic University of Gaza
Fault detection Lecture (3).
Vita 83 Working Group proposal for Rugged packaging,
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
Power Semiconductor Systems II
Servo Motor Control Using Variable Frequency Drive
2500 R Midtown Sacramento Municipal Utility District
Photovoltaic Systems Engineering Session 10
Power Semiconductor Systems I
Year 9 Entry Level Computing
Power Semiconductor Systems II
Power Semiconductor Systems II
Stand-By Emergency Lighting Inverter
Indoor Off-Grid and Grid Lighting
Stand alone vs. interconnected
Power Conditioners and Uninterruptible Power Supplies
Introduction to Motor Drives
Presentation transcript:

«TENSY GROUP» Moscow, Russia Energy Storage System «TENSY GROUP» Moscow, Russia

Energy Storage System (hereinafter ESS) is a system of two-way inverters (converters DC battery voltage to AC voltage and back again) and the rechargeable battery pack. The system is constantly connected to the power grid to control the parameters of the mains voltage and synchronization with the grid. During peak-demand period when the load exceeds the rated capacity of the power grid, ESS begins to give the required energy to the grid (to the load). During off-peak period, batteries are charging. ESS also allows: to compensate for reactive power; to compensate for harmonics of the load current; to symmetrize phase voltage; to adjust the frequency of the power grid.

Modes of operation: Energy storage mode with batteries: Energy storage mode Mode of transfer of the electric power to the power grid Adding power mode Mode of autonomous power supply of loading without batteries: Mode of reactive power compensation Mode of compensation of load current harmonics Mode of balancing of interphase current

Energy storage mode ESS switches to the energy storage mode if there is no need for a power output. When the electrical parameters are within the working range, ESS charges the batteries. The operator sets the value of power that is consumed from the power grid .

Mode of transfer of the electric power to the power grid ESS goes to the mode of conversion DC to AC. AC voltage is synchronized in frequency, phase and instantaneous value of the voltage to the mains voltage. Output current of ESS is limited within specifications.

Adding power mode ESS switches to the mode of power supply of load without output of energy to the power grid. Battery DC voltage is converted into AC voltage which is synchronized in frequency, phase and instantaneous value of the voltage to the mains voltage. In this case the output current of ESS is limited by consumption of the current of load. In this mode, ESS measures the level of power consumed by the load. If it exceeds a predetermined threshold of consumption, ESS begins to add power corresponding to the difference between the predetermined threshold of consumption and consumed by the load.

Mode of autonomous power supply of load ESS switches to the mode of off-line power supply of load with unplugging. ESS control system makes control of battery voltage and turns off the power output at low battery voltage to prevent deep discharge of batteries. In this case load will be plugged back to the mains, and ESS will switches to energy savings mode (if different algorithm of work of ESS is not specified by the operator).

Mode of reactive power compensation ESS measures the mains voltage and the current consumed by the load and synthesizes such a form of output current that allows to compensate for the reactive component of power and suppress the higher harmonics of the load current. Stored in the batteries energy is not consumed. 1) voltage and current of load 2) voltage and current of load, and compensating current of ESS 4) Mains voltage and compensating power of ESS 3) voltage and current of load, and the resulting mains current

Mode of compensation of load current harmonics ESS measures the mains voltage and the current consumed by the load and synthesizes such a form of output current that allows to suppress the higher harmonics of the load current. Stored in the batteries energy is not consumed . 1) voltage and current of load 2) rated values of load current harmonics 3) desirable current of compensation 4) desirable and actual current of ESS 5) voltage and compensated current of main 6) Rated load current harmonics and the compensated current of main

Mode of balancing of interphase current When the load consumes a current from the power grid uneven, ESS switches to the balancing mode taking power from the underloaded phases and giving it to the overloaded phases. This Mode is exclusively due to the mains energy, without consuming of battery resources. Phase 1 is underloaded. Phase 2 and Phase 3 are overloaded Two-way inverter takes the current from Phase 2 and Phase 3 and gives it to Phase 1 Resulting current of phases

The combined operating modes of ESS are possible. Combined modes The combined operating modes of ESS are possible. Switching between modes is possible by using the algorithm in an automatic mode or by the operator's command or by the programmed schedule. It can be controlled from the ESS control console or remotely by using: Ethernet GSM-modem RS-232 ports USB Dry contact Wi-Fi.

Thanks for watching www.m-volt.ru