Laboratory evaluation of LASIK flap parameters created with 2 femtosecond lasers ASCRS, San Diego 2011 Chatzilaou, Georgios, MD¹ A. John Kanellopoulos,

Slides:



Advertisements
Similar presentations
بسم الله الرحمن الرحیم LDV. Femto-LASIK Basir Eye Center Dr. Ahmad Shojaei
Advertisements

Case report The features of the femtosecond laser system flap creation process on the eye after radial keratotomy. O.F. Ziiatdinova, L. N. Safiullina Eye.
Evaluation of Enhancement Rates following Hyperopic LASIK with Femtosecond versus Microkeratome Assisted Flap Creation Raj Rajpara, BS * Richard M. Awdeh,
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
Intraoperative Aberrometry Mark Packer, MD, FACS Clinical Associate Professor Oregon Health & Sciences University.
Laser Bridge AK: Laser Bridge AK: Novel Architecture for Laser Astigmatic Keratotomy Comparison and Validation of Patient-Specific Computational Modeling.
Evaluation of a new technique for the preparation of endothelial grafts for Descemet’s membrane endothelial keratoplasty (DMEK) World Cornea Congress VII.
Clinical evaluation of foldable acrylic phakic IOL (fP) implantation ASCRS, San Diego, 2011 A.John Kanellopoulos, MD Professor NYU Medical School, NY Director,
Prospective, Randomized Comparison of Fellow Eyes Undergoing SBK with Use of Brimonidine 0.025%, Naphazoline 0.025% with Pheniramine 0.3%, or Artificial.
Topography-Guided Photorefractive Keratectomy for Irregular Astigmatism following Penetrating Keratoplasty Johnson Tan, MBBS MRCSEd (Ophth) FRCSEd (Ophth)
US Trends in Refractive Surgery: 2012 ASCRS Survey
Comparison of Orbscan and Ultrasound Pachymetry Measurements Faik Orucov, MD, Abraham Solomon, MD,Ziv Caspi, David Landau, MD, Eyal Strassman, MD, and.
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
INTRA OPERATIVE ONLINE PACHY METRY –A SAFETY TOOL Dr. KUMAR J DOCTOR DOCTOR EYE INSTITUTE MUMBAIINDIA NO FINANCIAL INTEREST.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Prof. A. John Kanellopoulos, MD 1 Long-term Safety and Efficacy of High-Fluence Collagen Crosslinking of the Vehicle Cornea in.
Comparison of flap thickness results using M2 130 micron flap and one use plus 100 micron flap Ahmed El-Massry M.D. Ophthalmology Department Alexandria.
Evaluation of Safety and Effectiveness of Multizone Laser Vision Correction in Presbyopic Patients ASCRS 2010 Paul Van Saarloos PhD – CustomVis, employee.
ASCRS 08 Changes Of Higher Order Aberrations After Excimer Laser Treatment For Moderate Myopia by Means of Preoperative Wavefront Aberration Levels using.
Author: Roger F. Steinert, M.D. Dr. Steinert is a paid Medical Monitor for ReVision Optics.
Custom Flap Formation: Advantages of Elliptical Flaps for LASIK Patients Custom Flap Formation: Advantages of Elliptical Flaps for LASIK Patients Henry.
March 2011 Bascom Palmer Eye Institute University of Miami Elaine Wu, M.D. Ana Paula Canto, M.D. William Culbertson, M.D. Sonia Yoo, M.D. Financial disclosure:
Effect of CXL on FS laser Channel Creation for ICR in KC Tamer M. El-Raggal, MD, PhD, FRCSEd Associate Professor of Ophthalmology Ain Shams University,
Highlights of the 2008 ASCRS member practice style survey David Leaming MD Survey Sponsors ( *Financial Disclosure ) Alcon Surgical AMO Bausch & Lomb.
Natalie Stanciu, MD Richard M. Awdeh, MD Takeshi Ide, MD Sonia Yoo, MD Bascom Palmer Eye Institute ASCRS 2009: San Francisco.
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR, Kerry D Solomon, MD Magill research center for vision correction Storm Eye Institute Medical University.
Refractive Accuracy of LASIK Using the IntraLase and Zyoptix BACKGROUND Wavefront guided customized lasik procedures are designed to correct both lower.
Descemet-Stripping Automated Endothelial Keratoplasty Grafts Prepared from Endothelial Side Using a 500 kHz Femtosecond Laser: Six-Month Outcomes Jesper.
A New Technique for Precise, Predictable SBK Surgery Using the B&L Zyoptix XP Microkeratome David R. Shapiro, MD Shapiro Laser Eye Center Ventura, California.
Factors which Influence Accommodative Amplitude in Crystalens HD Patients Uday Devgan, MD, FACS Devgan Eye Surgery, Los Angeles, CA FINANCIAL DISCLOSURES:
Wound Architecture and Wound Healing after Torsional and Longitudinal Phaco in a Rabbit Model Carolina Eyecare Physicians, LLC Research Assistant Professor.
Retrospective Comparison of Flap Complications in LASIK Using Hansatome Mechanical Microkeratome and Femtosecond Laser Majid Moshirfar, MD Jeffrey P Gardiner,
Study of Flap Thickness Precision with a Femtosecond Laser Shinagawa LASIK Center Tatsuya Yonekawa,MSc ; Minoru Tomita,MD.PhD ; Youhei Iida,CE ; Yuko Inada,CE.
Effect of an irregular anterior surface on a lamellar femtosecond laser cut Robert E. Fintelmann, MD Michele M. Bloomer, MD Bennie H. Jeng, MD Authors.
Jay Fiore MD, Eric Donnenfeld MD, Hank Perry MD, Dana Morschauser OD
Faik Orucov*, MD, Joseph Frucht-Pery, MD, David Landau, MD, Eyal Strassman, MD, Abraham Solomon, MD Clinical outcome of thin corneas after laser in situ.
Augenabteilung am St. Franziskus Hospital Münster Lasik Flap Thickness using the Zyoptix XP Microkeratome Susanne Stottmeister, Suphi Taneri * * Travel.
US Trends in Refractive Surgery: 2011 ASCRS Survey Richard J. Duffey, MD David Leaming, MD Chicago: April 21, 2012.
James S. Lewis, MD I have no financial interest in the subject matter of this poster Mathematical Analysis of 150- Degree Femtosecond Reverse Bevel ASCRS.
Case report No financial interest The features of the Femtosecond Laser system flap creation process on the eye after radial keratotomy O.F. Ziiatdinova,
Comparison of Varying the Ablation Diameter in LASIK and LASEK:The Effects on Anterior Chamber Depth (ACD) and Regression at 3 months Minoru Tomita, MD,
Corneal Endothelial Cell Changes After LASIK Using a Femtosecond Laser Minoru Tomita, MD, PhD, Masaru Aoyama, MD, Minoru Tomita, MD, PhD, Masaru Aoyama,
Postoperative Uncorrected Visual Acuity (UCVA) versus Preoperative Best Corrected Visual Acuity (BCVA) with the WaveLight Refractive Suite (Excimer EX500.
Comparison of two differents ultrasound mode in BMICS technique : Pulse and Continuous US Danielle DEIDIER M.D. Clinique Saint Vincent Toulon - France.
Initial clinical experience with the FS200 Femto and EX500 excimer lasers for LASIK ASCRS, San Diego 2011 A.John Kanellopoulos, MD Professor NYU Medical.
Safety of Flap Lift Enhancements after IntraLase Lasik Lewis R Groden, MD (1,2) Lewis R Groden, MD (1,2) Sunir Joshi, MD (1) Sunir Joshi, MD (1) 1 Department.
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
Evaluation of Topography-guided LASIK and Simultaneous Collagen Cross-linking in the Management of Post-LASIK Ectasia Diana Ng, MD1 Anastasios John Kanellopoulos,
Quality of life outcomes with the WaveLight Refractive Suite (Excimer EX500 and Femtosecond FS200 lasers) Arthur Cummings MD1, Mathias Maus MD2, Dan.
Femtosecond Laser Good, Bad & Ugly
Measurement of 60 kHz Femtosecond LASIK Flaps with Anterior Segment Ocular Coherence Tomography & Ultrasonic Subtraction Pachymetry Edward E. Manche, MD.
Prophylactic collagen cross-linking (pCXL) in high risk (HR) LASIK
Incidence of Diffuse Lamellar Keratitis After LASIK with 15 KHz, 30 KHz and 60 KHz IntraLase Femtosecond Laser Flap Creation Carly Guss, BA,1 Christina.
EPI-LASIK using the Zyoptix XP EPI Separator Suphi Taneri
Clinical outcome of thin corneas after laser in situ keratomileusis
University of Ulsan College of Medicine
No financial interest for all authors
Asociación Para Evitar La Ceguera En México
Three-Year Follow-up after LASIK in Eye with Extremely Thin Corneal Bed Hidemasa Torii, MD, Kazuno Negishi, MD, Murat Dogru, MD, Takefumi Yamaguchi, MD,
Comparison of topography-guided (TGL) to standard LASIK (SL) for hyperopia. How important is adjustment for angle kappa? ASCRS 08 A. John Kanellopoulos,
Preoperative Distribution of Higher Order Aberrations in Patients Undergoing LASIK Perry S. Binder, MS MD.
First 10 Cases with 150 kHz Intralase Enabled Keratoplasty (IEK) Compared to Standard Penetrating Keratoplasty (PK) Christopher L. Blanton, M.D. Financial.
Optical Coherence Pachymetry with the ESIRIS DOCTOR EYE INSTITUTE
Dr Haralabos Eleftheriadis, M.D Ultralase Clinic Bristol UK
Mohamed Abdelrahman Awadalla,FRCS Magrabi Eye Hospital Cairo - Egypt
Novel Cornea OCT (cOCT) findings in early and long term follow up of collagen cross-linking (CXL) for keratoconus (KCN) ASCRS, Boston 2010  John Kanellopoulos,
PERRY S. BINDER, MS MD* San Diego, California
John C. Hwang, MD MBA Edward S. Harkness Eye Institute
University of California, San Diego Shiley Eye Center
Shorter Duration, Higher Ultraviolet A Irradiation (UVA) Fluence Collagen Cross-linking (CCL) for Keratoconus (KCN) Frank A. Killian, MD and A. John Kanellopoulos,
Presentation transcript:

Laboratory evaluation of LASIK flap parameters created with 2 femtosecond lasers ASCRS, San Diego 2011 Chatzilaou, Georgios, MD¹ A. John Kanellopoulos, MD² Professor NYU Medical School, NY Director, Laservision.gr Institute, Athens, Greece Financial Interest: None¹ Travel Reimbursement from Alcon, USA, Wavelight, Bausch and Lomb² Kanellopoulos, MD www.brilliantvision.com

Kanellopoulos, MD www.brilliantvision.com Purpose The laboratory evaluation of LASIK flap of a novel femtosecond laser versus our standard. FS60 FS 200 Kanellopoulos, MD www.brilliantvision.com

Kanellopoulos, MD www.brilliantvision.com Methods 20 cadaver corneas, underwent LASIK flap creation Group A(10 corneas)with the Wavelight, Ultraflap 150kHz and Group B (10 corneas) with the INTRALASE FS60 Peri-operatively the flap diameter (FD), hinge length (HL) , total cornea and flap pachymetry(tP & fP), and flap creation interval were measured. Following tissue fixation, light microscopy sections were calculated for: peripheral, para-central and central thickness, intra-flap thickness variability (IFTV), diameter, hinge length and overall interface quality. Kanellopoulos, MD www.brilliantvision.com

Comparison of simultaneous use Kanellopoulos, MD www.brilliantvision.com

Kanellopoulos, MD www.brilliantvision.com Results Group A: In mean values: fP: 110 microns +/- 5μm, IFTV: (+/- 5)μm. FD: 8.2 mm, HL: 3.55 mm +/- 0.34, creation time 15 seconds Group B: In mean values: fP: 115 +/-5μm(intended: 110), IFTV: (+/-5)μm, FD: 8.1 mm(intended: 8), HL: 3.25mm +/-0.24, creation time 17 seconds Kanellopoulos, MD www.brilliantvision.com

Kanellopoulos, MD www.brilliantvision.com Conclusions This study suggests highly reproducible flap parameters with both platforms. Further clinical studies may validate these data. Kanellopoulos, MD www.brilliantvision.com

Kanellopoulos, MD www.brilliantvision.com Thank you www.brilliantvision.com Kanellopoulos, MD www.brilliantvision.com