Science Requirements The FGM shall measure DC and low frequency perturbations of the magnetic field  see performance requirements The FGM shall measure.

Slides:



Advertisements
Similar presentations
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
Advertisements

Op-Amp- An active circuit element designed to perform mathematical operations of addition, subtraction, multiplication, division, differentiation and.
Analog Sensing 101 WITH P Agenda  Analog Signal Characteristics  Common Problems with A/D Conversion  Clipping  Small Signals  Aliasing  Analog.
Interfacing Analog and Digital Circuits
PLC front-end Design Review Curtis Mayberry
Ganymede Lander Page 1 - Magnetometer Proposal -Moscow, Magnetic Field Measurement Onboard a Ganymede Lander Experiment Proposal Based on Experiences.
Satellite Construction Attitude Control and Determination System Attitude Control and Determination System Jan Hales, Martin Pedersen & Klaus Krogsgaard.
Magnetometer calibration and detection Robert Szewczyk, Alec Woo Nest Retreat June 17, 2002.
14/06/20151 MORE Requirements seen from ESA Pedro Pablos 1 st MORE Team Meeting 27 Febrero 2007.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Stability Workshop April , 2007 NSLS-II Electrical Systems G. Ganetis NSLS-II Electrical Systems NSLS-II.
Characteristics of Op-Amp &
Magnetic Field Instrument for the BepiColombo Planetary Orbiter
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
THEMIS-SCM THM – SCM – CDR – 08-April-2004 in Velizy
MERMAG-M/MGF MGF-OS MGF-IS MAST-MGF MAST-SC PWI-SC Credit : RISH, Kyoto Univ.
SIGMA-DELTA ADC SD16_A Sigma-Delta ADC Shruthi Sujendra.
PWI Meeting Kanazawa 25/03/2006 Active Measurement of Mercury’s Plasma, AM 2 P CENTRE NATIONAL DE LA RECHERCHE SCIENTIFIQUE Laboratoire de Physique et.
THEMIS Mission PDR/CAR 1 UCB, November 12-14, 2003 Search Coil Magnetometer (SCM) Mission PDR/CAR Alain Roux CETP-Velizy Co-i: O.Le Contel Technical Manager:
THEMIS Instrument CDR 1 UCB, April 19-20, 2004 Boom Electronics Board (BEB) Engineering Peer Review Apr. 20, 2004 Hilary Richard.
1 Successive Approximation Analog-to- Digital Conversion at Video Rates 指導教授 :汪輝明 學 生:陳柏宏.
THEMIS Instrument CDR 1 UCB, April 19-20, 2004 Boom Electronics Board (BEB) Engineering Peer Review Apr. 20, 2004 Hilary Richard.
THEMIS Instrument FM2/FM3 PERFGM 1 Teleconference 8/30/2005 THEMIS Instrument FM2/3 Pre-Environmental Review Fluxgate Magnetometer (FGM) Dr Ellen Taylor.
THEMIS SUITE PRE-ENVIRONMENTAL REVIEW 1 UCB May 2, 2005 THEMIS Pre-Environmental Review Instrument Verification Overview Ellen Taylor University of California.
Lander Experiment ROMAP
Solar Probe Plus Fluxgate Magnetometer QSR – Oct SPF MAG Quarterly Report – Oct 2014 The MAG EM1 (EQM) (board and frame at right) was successfully.
THEMIS INSTRUMENT CDR Peer ReviewSYSTEM- 1 UCB, April 19, 2004 TITLE: Test Flow RFA CODE: UCB-10 REQUESTED BY: Preble SPECIFIC REQUEST: We recommend that.
Themis Mission CDR FGM- 1 UCB, June FGM Hans-Ulrich Auster Institut für Geophysik und Meteorologie TU Braunschweig.
SWGTemplate- 1 UCB, Nov 15/16, 2006 THEMIS SCIENCE WORKING TEAM MEETING Search Coil Magnetometer (SCM) team Co-i: A. Roux, O. Le Contel Technical Manager(*):
Dec 1, FIELDS Top Level Requirements Review S. Harris (UCB)
1 BROOKHAVEN SCIENCE ASSOCIATES Power Supply Status George Ganetis Power Supply Status ASAC Review October 22-23, 2009.
BlackBox Sat Critical Design Review Colorado State University-Pueblo April 2, 2004 Greg Barela Jose Segovia Enrique Cornejo.
Magnetic Field Stability Measurements Joe DiMarco 23Oct07.
FGM peer CDR FGS - 1 Berlin, April 6, 2004 FGS Mechanical Design Hans-Ulrich Auster Institut für Geophysik und Meteorologie TU Braunschweig.
IDPU F1 Test Review FGM Fluxgate Magnetometer Michael Ludlam University of California - Berkeley.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
THEMIS Mission PDR/CAR 1 UCB, November 12-14, 2003 Instrument Design Fluxgate Magnetometer (FGM) Werner Magnes Institut fuer Weltraumforschung (IWF) Austrian.
Double Star Active Archive - DWP/STAFF 1 Double Star Active Archive STAFF/DWP Keith Yearby and Hugo Alleyne University of Sheffield Nicole Cornilleau-Wehrlin.
THEMIS-SCM SCM – OVERALL RESSOURCES – STATUS versus REQUIREMENTS ItemSpecificationStatus Sensor Bandwith Sensor Sensitivity Up to 4 kHz 1 pT/√Hz at 10.
Operational Amplifiers Chapter 10 Boylestad Electronic Devices and Circuit Theory.
CI Lecture Series Summer 2010 An Overview of IQ Modulation and Demodulation Techniques for Cavity LLRF Control.
Crashcourse Oscilloscope and Logic Analyzer By Christoph Zimmermann.
MECH 373 Instrumentation and Measurements
Mrs V.S.KharoteChavan,E&Tc,PC poly
FIELDS MEP PSR - MAGi, MAGo 002C_SPF_MEP_IPSR_MAG_Results
Solar Probe Plus – FIELDS Main Electronics Package
Chapter 10: Operational Amplifiers
A 12-bit low-power ADC for SKIROC
FGM CDR FGM Electronics (FGE) Ronald Kroth MAGSON GmbH Berlin Germany.
Electronic Devices Ninth Edition Floyd Chapter 13.
INSTRUMENT DATA PROCESSING UNIT (IDPU) REQUIREMENTS
ProtoDUNE SP – Slow control temperature readout setup test
Search Coil Magnetometer (SCM) CDR/Peer review CETP-Velizy
96-channel, 10-bit, 20 MSPS ADC board with Gb Ethernet optical output
MAGIC Interface Issues
INDUCTION MOTOR PROTECTION FOR SINGLE PHASING, OVERVOLTAGE AND OVER TEMPERATURE Submitted by:
Boom Electronics Board (BEB)
Institut für Geophysik und Meteorologie
Operational Description
THEMIS INSTRUMENT TRAINING
Mac Keiser and Alex Silbergleit
Digital Acquisition of Analog Signals – A Practical Guide
Instrument Considerations
Lesson 8: Analog Signal Conversion
Mac Keiser and Alex Silbergleit
Lock Acquisition Real and Simulated
Fundamentals of Data & Signals (Part II)
Beam Current Monitoring with ICT and BPM Electronics
Conversation between Analogue and Digital System
Turning photons into bits in the cold
Attitude Determination and Control Preliminary Design Review
Presentation transcript:

Science Requirements The FGM shall measure DC and low frequency perturbations of the magnetic field  see performance requirements The FGM shall measure time wave and structure propagation between probes The FGM shall provide information on plasma currents based on instantaneous magnetic field differences on two or more probes, separated by >0.2RE ? modelling requirements?

Performance Requirements The absolute stability of the FGM shall be less than 1nT The relative stability of the FGM shall be less than 0.1nT Sensor Characteristics: offset / time: < 0.1nT/h; < 1nT/year; (+ s/c) offset / temperature: < 0.1nT/°C scale value / temperature: 24ppm (0.8nT/°C at 32000nT) orthogonality / temperature: can be neglected

Performance Requirements The FGM resolution shall be less than 0.1nT The FGM science range shall exceed 0-1000nT FGM provides always 0.01nT resolution independently of the external field The maximum feedback field (range) is about 32000nT therefore three 24bit values will be sent to the IDPU 16 bit will be selected for transmission 10pT if B < 320nT 160pT if B > 2500nT 1.2nT if B > 20000nT

Performance Requirements The FGM noise level at 1Hz shall be less than 0.1nT Sensor noise is less than 10pT/sqrt(Hz) at 1Hz 26pT rms 91pT2/Hz : 9pT/Sqrt(Hz) pT2 pT additional “noise” will be generated by the differential nonlinearity of the 12 bit DAC’s (10% of LSB) <1000nT - 50pT(maximum), >1000nT - 1.5nT(maximum)

Performance Requirements The FGM frequency range shall exceed DC-1Hz primary data (FPGA1 -> FPGA2) are 128Hz mean values (128Hz data: 7.5ms measurement, 0.3ms feedback setting) further averaging will be done by FPGA2 and IDPU Problem: to find the right compromise between telemetry rate, aliasing errors, and spin period interferences. Equator-S: aliasing errors are not detected although bandwidth was to high. Cluster: ratio between spin period and data rate of 100 is sufficient.

Performance Requirements The FGM calibration shall ensure 1nT absolute accuracy Determination of 3 offsets and 9 elements of a matrix (scale values, non-orthogonality, sensor orientation) spin of satellite provides 8 of 12 offsets perpendicular to spin axis (2): < 0.1nT relation between scale values perp. to spin axis (1): < 10-4 non-orthogonality (3): < 5’’ orientation to spin axis (2): < 5’’ scale values are sufficient known from preflight calibr. orientation depends on mech. alignment of sensor (0.1-1°) spin axis offset is the problem (1nT by known physics)

Resource Requirements The FGM shall not exceed the allocated mass budget (70g) 36g sensor 30g-40g for the housing

Resource Requirements The FGM shall not exceed the allocated power budget (800mW) we need +5Vd & +2.5Vd (FPGA & DAC): 10mA +8Va (excitation & amplifiers): 40mA (30mA+10mA) - 8Va (amplifiers): 10mA +5Va (ADC): 15mA - 5Va (ADC): 15mA 600 mW if all voltages will be provided 800 mW if ADC will be provided by +/- 8V 1000 mW if only +/- 8V is available

Resource Requirements The FGM shall meet the following thermal requirement survival temperature range (no-op): –50°C to +65°C operating temperature range (op): –20°C to +40°C cold start: -50°C  tested for Rosetta and VEX design and manufacturing of thermal sensor cover is still tbd

Facilities Integration and Tests Midex Quality Reqiurements e-parts, see following list fabrication of sensor in BS (no cleanroom environment) calibration (no cleanroom environment) in Magnetsrode, Jeserigerhütten ... (outside of civilisation) calibration facilities for final tests in Graz, Berlin, BS, und Berkeley should be identical, stimulation by coil system to test ranging ... Schedule has to be reworked

e-parts: overview DAC: FPGA: Amplifier: ADC: Instr. Ampl.: bold - qualified red - preferred DAC IDPU Sensor ADC FPGA feedback sense excitation FPGA: 2 x 54SX32 1 x 54SX72 DAC: 6 x 8043 6 x 8143 Amplifier: 6 x LT1013 3 x LT1013 & 3 x AD648 ADC: 3 x AD6764 3 x AD7872 Instr. Ampl.: 3 x AD524 3 x AD625 Prec. Resistors.: Megatron MMQ / MMP Voltage Reference: 1 x LT1013 Driver: 1 x HS9-4424 1 x MIC4425 Line Regulators: LM117 & LM137

Contamination Requirement all instruments shall comply with the MC standard UCLA responsibility if necessary we can provide ESTEC software turntable to determine magnetic moments gradiometer mounted on a guide bar to estimate s/c field

FGM should be switched on before boom deployment operation operation during ... all science phases in the same mode all technically interesting phase (orbit change, eclipse) FGM should be switched on before boom deployment

IDPU requirements FGM software FGM hardware selection of 16bit, orbit controlled or auto-controlled despin onboard? relation to other experiments test data necessary? responsibility? FGM hardware clock / timing