Automation of Solid Phase Extraction Column Chromatographic Cleanup

Slides:



Advertisements
Similar presentations
Chem. 231 – 3/4 Lecture. Announcements I Set 1 Lab Reports –Both Lab Reports due 3/13 –Only one of the lab reports needs to be detailed, the other can.
Advertisements

Advantages to Automating the 1664 Method Joe Boyd March 28, 2012.
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
ENVIRONMENTAL ANALYSIS I. Solid Phase Extraction sorbent configurations – layered phases.
Caffeine as a Surrogate for Cocaine in an HPLC Forensic Experiment Ray A. Gross Jr, Indravadan Shah and Muhamed Jasarevic Department of Physical Sciences.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Chromatography.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Prabh Jassal SUPA Che113 Forensics Ms. Tolentino.
Chromatography Dr.Tawfeq A. Al-Howiriny Associate Professor
Chapter 6 - Chromatography
High Performance Liquid Chromatography
Chromatography Chapter 6.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
Separation Science Differences in IMFs can be used to separate chemical substances for further analysis. Differences in IMFs can be used to separate chemical.
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
General methods for flash chromatography using disposable columns Special report Marlon Vincent V. Duro McK group meeting July 6, 2015.
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
Developing a Method for Measuring Amlodipine Levels in Cat Plasma By:Preston Bull Advisors: Mike Gallagher, Dr. Webster.
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
Lecture 7 Chromatography Intro!.
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
HPLC – High Performance Liquid Chromatography
Chapter 29 Supercritical Fluid Chromatography and Extraction.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
Chem. 231 – 2/11 Lecture.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
HPLC.
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
CHROMATOGRAPHY.
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Chem. 133 – 5/2 Lecture.
LU 3: Separation Technique (P2)
Chromatography- TLC & HPLC
High Performance Liquid Chromatography (HPLC)
LC-MS/MS Analysis of Tetracycline antibiotics in Honey using Advance UHPLC-EVOQ™ SIMA LAB PVT LTD.
Automation of Sample Preparation for Trace Analysis Haibin Wan
Chem. 31 – 11/1 Lecture.
HPLC.
High Performance Liquid Chromatography (HPLC)
Solid Phase Extraction Optimization Experiment
AssayMAP Bravo for Automated Sample Preparation
Organic Instrumentation
Dnyanasadhana College, Thane. Department of Chemistry M. Sc
Supercritical Fluid Chromatography and Extraction
Extraction Procedure (2)
Extraction Procedure (2)
HPLC.
An Introduction to Chromatographic Separations
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
VAPOUR PHASE CHROMATOGRAPHY
What is chromatography?
Chromatography Daheeya Alenazi.
CHROMATOGRAPHY Chromatography : It is a physical method of separation in which the components to be separated are distributed between two phases, one.
Introduction to the NGC Chromatographic System
M.S COLLEGE OF ARTS, SCIENCE, COMMERCE AND B.M.S
GAS CHROMATOGRAPHY.
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
High performance liquid chromatography (HPLC)
Presentation transcript:

Automation of Solid Phase Extraction Column Chromatographic Cleanup and Column Chromatographic Cleanup Haibin Wan PromoChrom Technologies Ltd. The term SPE was heard 20 years ago. Yet column chromatography is a more general term and old technique. At beginning SPE was refer to water LLE the organic layer is bonded to silica gel. Later cartridges packed with silica, florisil also called SPE. So now if you use big column, it is column chromatography. If you use prepacked cartridges, you are doing SPE. PromoChrom Technologies www.promochrom.com

Problems with Manual Operation Unstable flow rate affects reproducibility and throughput. Not convenient for multi step elution. Labor intensive. SPE of water sample Limited flow rate depending on the achievable vacuum and the resistance of the cartridge. The flow could stop due to particle and large molecules from samples. We know when you are doing column chromatography, it cannot get dry out. Or the flow will be uneven. Elution of trapped analytes. Vacuum may be applied depending on the flow of solvent. PromoChrom Technologies www.promochrom.com

Advantages of Automated operation Reduce exposure of operators to hazardous solvents. Release chemists and technicians from tedious and labor intensive work. Improve reproducibility and avoid human error. Enable multiple step elution for complex sample cleanup. PromoChrom Technologies www.promochrom.com

Approaches for Automation Off line approach Automate the procedures in manual operations On line approach Integrate SPE with instrumental determination PromoChrom Technologies www.promochrom.com

PromoChrom Technologies www.promochrom.com SPE-01 Plus Cleanup Station For offline automation of SPE and column chromatography Designed for pesticides and drug residues in food samples waste Process 9 samples Up to 5 elution solvents Collect 2 fractions for each sample PromoChrom Technologies www.promochrom.com

Computer free and easy operation Step 1, edit method (only necessary for new method) Step 2, pick samples and method Step 3, press start button PromoChrom Technologies www.promochrom.com

An example of method for SPE-01 Plus Action Flow rate Volume Elute with 1 16 10 1 Elute with 2 2 Add sample 4 5 3 Elute with 3 Collect to 1 25 Eluent 1, acetone; eluent 2, hexane; eluent 3, hexane +5% acetone. Column, Florisil. This method is for analysis of pyrethroid pesticides in tea. The Florisil column is first conditioned with acetone and followed with hexane. The concentrated extract is added to the column. It is then first eluted with hexane to remove interference. The targeted components are eluted using solvent 3 and collected for GC-ECD analysis. PromoChrom Technologies www.promochrom.com

PromoChrom Technologies www.promochrom.com Elution pattern of 5 pyrethroid insecticides on column packed with 3 gram flowrisil (fenpropathrin, cyhalothrin, cypermethrin, fenvalerate, deltamethrin) Data provided by Tea Research Institute, Chinese Academy of Agric. Sci. Flow rate=6 mL/min Flow rate=18 mL/min Volume (mL) 0 5 10 15 20 25 Volume (mL) 0 5 10 15 20 25 PromoChrom Technologies www.promochrom.com

PromoChrom Technologies www.promochrom.com Elution pattern of 5 pyrethroid insecticides on column packed with 3 gram flowrisil (fenpropathrin, cyhalothrin, cypermethrin, fenvalerate, deltamethrin) (Continued) As shown in previous slide, there is no significant change in elution pattern when flow rate is increased from 6 mL/min to 18 mL/min. Much faster elution can be achieved using the automated SPE. PromoChrom Technologies www.promochrom.com

PromoChrom Technologies www.promochrom.com Comparison of SPE-01 plus with other automated SPE SPE-01 plus is specially designed for analysis of pesticide and drug residues in food samples. Most other automated SPE instruments are designed for clinical samples. The two applications have different requirements in sample volume, elution steps, and fraction handling. SPE-01 plus use valves for liquid handling. Other automated SPE instruments use XYZ motion control. SPE-01 plus has lower cost and better reliability. The valve design enables SPE-01 plus to use different type of SPE columns, such as self packed florisil column, whereas other automated SPE need to use expensive adapters and can only handle commonly used dimension of SPE. SPE-01 plus does not need computer. Its small size saves the expensive lab space and makes it easy to be placed in a fume hood. PromoChrom Technologies www.promochrom.com

PromoChrom Technologies www.promochrom.com SPE-03 4-Channel SPE System for Water Samples Process 4 samples simultaneously Separated line for water and organic waste Blow dry function Detection and smart handling of blockage Computer free Small foot print The major difference with SPE-01 plus is in number of pumps. SPE-03 has four pumps and SPE-01 plus has only one. PromoChrom Technologies www.promochrom.com

A comparison between manual and automated SPE Tap water spiked with 9 triazole pesticides (三唑类农药) at 1 ppb level was extracted using both vacuum manifold and SPE-03. Data provided by Xiamen Powertech Technologies Ltd. PromoChrom Technologies www.promochrom.com

PromoChrom Technologies www.promochrom.com Online SPE - Integrate SPE with HPLC Analysis Two approaches: 1. One sample per SPE column approach. Easy to develop robust method. High cost. 2. Single SPE column approach One SPE column for multiple samples. Much less expensive. Suitable for clean samples. For dirty samples, finding reusable SPE column is the key for success application. PromoChrom Technologies www.promochrom.com

Online SPE from PromoChrom Waste Ports 1-4 for solvents LC pump Syringe pump Ports 5-14 for samples Components from online SPE Detector The online SPE looks after sample injection and elution of SPE column. The HPLC does not need a secondary pump and sampler. This is the online SPE system with the lowest cost. PromoChrom Technologies www.promochrom.com

Online SPE Control Software Real time display of flow path and instrument status; Overlapped injection to save time in sample loading Step run function for easy method development; Use method and sequence for analysis, similar concept as Agilent Chemstation; Easy integration with any HPLC; Diagnosis tool for trouble shooting. PromoChrom Technologies www.promochrom.com

Direct Analysis of PAH in Tap Water at ppt level HPLC conditions: Mobile phase, methanol + water (90:10); Flow rate, 1.5 mL/min; Column, PromSil C18 4.6x250 mm; Detection, 252 nm, Agilent G1314A VWD ; Stop time, 8 minutes. Online SPE procedures: Elute with 2 mL methanol at 6 mL/min; Elute with 3 mL water + methanol (95:5, ) at 6 mL/min; Load up to 40 mL sample; Inject sample to HPLC column; Start HPLC analysis. SPE column, Trap N, 4.6 x 10 mm. PromoChrom Technologies www.promochrom.com

Direct Analysis of PAH in Tap Water at ppt level Phenanthrene in tap water at 50 ppt; sample volume, 40 mL. Estimated quantitation limit 5 ppt Phenanthrene in tap water at 5 ppb; sample volume, 40 mL. PromoChrom Technologies www.promochrom.com

Direct Analysis of PAH in Tap Water at ppt level Repeatability (peak area mAU) Repeat 5 ppb (20 mL) 0.1 ppb (20 mL)* 0.01 ppb (40 mL)* 1 1273 39.9 26.5 2 1249 37.0 26.0 3 1239 38.4 27.3 Average 1254 26.6 CV% 1.4 3.8 2.5 *As the tap water has 0.04 ppb phenanthrene, the 0.01 level should be 0.05 ppb. PromoChrom Technologies www.promochrom.com

Comparison Between Offline and Online Approach Items Offline SPE Online SPE Analysis time Over 1 hours per sample. This includes extraction of 1 liter water sample, concentrate to 1 mL, and use 10-20 uL for HPLC analysis (equivalent to 10-20 mL water sample). Over 90% of processed sample is not used. 15 minutes per sample. All of 20-40 mL sample is injected to HPLC column. The SPE procedures are carried out while the HPLC is analyzing previous sample. Material cost One SPE column per sample (US$1.5-2), 20-30 mL methanol for conditioning and elution. One SPE column for 50-100 samples, US$0.5-1 for 1 sample; 2 mL methanol for each sample. Data quality RSD above 5% at sub ppb level RSD <5% even at 50 ppt. This is due to simplified and automated procedures. Suitable application Semi volatile pollutants in water, in which determination is by GC or GC-MS Chemicals that can be analyzed by HPLC or LC MS PromoChrom Technologies www.promochrom.com

PromoChrom Technologies www.promochrom.com Thank You PromoChrom Technologies www.promochrom.com