RD50 Workshop June 2016, Torino, Italy

Slides:



Advertisements
Similar presentations
of Single-Type-Column 3D silicon detectors
Advertisements

Micron detector testing in Liverpool G. Casse – O. Lodge Laboratory, University of Liverpool.
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
New approach to simulate radiation damage to single-crystal diamonds with SILVACO TCAD Florian Kassel, Moritz Guthoff, Anne Dabrowski, Wim de Boer.
May 14, 2015Pavel Řezníček, IPNP Charles University, Prague1 Tests of ATLAS strip detector modules: beam, source, G4 simulations.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 technical workshop 03/17/ 2010 Jefferson lab Update on.
Paul Sellin, Radiation Imaging Group Charge Drift in partially-depleted epitaxial GaAs detectors P.J. Sellin, H. El-Abbassi, S. Rath Department of Physics.
Ultra-Fast Silicon Detector 1 This report is a summary of what was shown at IEEE. Nicolo Cartiglia, INFN, Torino - UFSD - Timing Workshop CERN 2014 Nicolo.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
TOF at 10ps with SiGe BJT Amplifiers
TCT+, eTCT and I-DLTS measurement setups at the CERN SSD Lab
Techniques for determination of deep level trap parameters in irradiated silicon detectors AUTHOR: Irena Dolenc ADVISOR: prof. dr. Vladimir Cindro.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
M. Bruzzi et al. Thermal donors in MCz Si, Trento Meeting Rd50 February 28, 2005 Mara Bruzzi, D. Menichelli, M. Scaringella INFN Florence, University of.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
Effect of Metal Overhang on Electric Field for Pixel Sensors Kavita Lalwani, Geetika Jain, Ranjeet Dalal, Kirti Ranjan & Ashutosh Bhardwaj Department of.
Time Resolution of Thin LGADs Results from the Nov 2014 Beam Test at CERN Improvement in hand: Sensor Capacitance Measurements with  Front TCT 1 Hartmut.
Evaluation of electron and hole detrapping in irradiated silicon sensors Markus Gabrysch 1, Mara Bruzzi 2, Michael Moll 1, Nicola Pacifico 3, Irena Dolenc.
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
June 22, 2009 P. Colas - Analysis meeting 1 D. Attié, P. Colas, M. Dixit, Yun-Ha Shin (Carleton and Saclay) Analysis of Micromegas Large Prototype data.
Ultra-Fast Silicon Detector 1 Aide memoire: we are exploring the possibility of using silicon detectors with moderate gain to achieve ~ 20 ps time resolution.
1 Nicolo Cartiglia, INFN, Torino - RD50 - Santander, 2015 Timing performance of LGAD-UFSD 1.New results from the last CNM LGAD runs 2.A proposal for LGAD.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
SIAM M. Despeisse / 29 th January Toward a Gigatracker Front-end - Performance of the NINO LCO and HCO Matthieu Despeisse F. Osmic, S. Tiuraniemi,
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
Simulations of Hadron Irradiation Effects for Si Sensors Using Effective Bulk Damage Model A. Bhardwaj 1, H. Neugebauer 2, R. Dalal 1, M. Moll 2, Geetika.
Ljubljiana, 29/02/2012 G.-F. Dalla Betta Surface effects in double-sided silicon 3D sensors fabricated at FBK at FBK Gian-Franco Dalla Betta a, M. Povoli.
Celso Figueiredo26/10/2015 Characterization and optimization of silicon sensors for intense radiation fields Traineeship project within the PH-DT-DD section.
Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Status.
21th RD50 Workshop, CERN, 14th – 16th November 2012 Charge carrier detrapping in irradiated silicon sensors after microsecond laser pulses Markus Gabrysch.
PH-DT-DD Meeting – PH-DT-DD: SSD-Solid State Detectors The team today (CERN & visitors): R&D: Development of radiation tolerant silicon detectors.
Charge Multiplication Properties in Highly Irradiated Thin Epitaxial Silicon Diodes Jörn Lange, Julian Becker, Eckhart Fretwurst, Robert Klanner, Gunnar.
Claudio Piemonte Firenze, oct RESMDD 04 Simulation, design, and manufacturing tests of single-type column 3D silicon detectors Claudio Piemonte.
10/25/2007Nick Sinev, ALCPG07, FNAL, October Simulation of charge collection in chronopixel device Nick Sinev, University of Oregon.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Double Electric field Peak Simulation of Irradiated Detectors Using Silvaco Ashutosh Bhardwaj, Kirti Ranjan, Ranjeet Singh*, Ram K. Shivpuri Center for.
A novel two-dimensional microstrip sensor for charge division readout D. Bassignana, M. Lozano, G. Pellegrini CNM-IMB (CSIC) M. Fernández, R. Jaramillo,
Timing capabilities of Ultra-Fast Silicon Detector 1 A parameterization of time resolution A program to calculate Time resolution UFSD Timing capabilities.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Investigation of the effects of thickness, pitch and manufacturer on charge multiplication properties of highly irradiated n-in-p FZ silicon strips A.
June T-CAD Simulations of 3D Microstrip detectors a) Richard Bates b) J.P. Balbuena,C. Fleta, G. Pellegrini, M. Lozano c) U. Parzefall, M. Kohler,
E-TCT measurements with laser beam directed parallel to strips Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Mikuž 1,2,
TCT measurements of HV-CMOS test structures irradiated with neutrons I. Mandić 1, G. Kramberger 1, V. Cindro 1, A. Gorišek 1, B. Hiti 1, M. Mikuž 1,2,
TPA-TCT A novel Transient-Current-Technique based on the Two Photon Absorption process 25th RD50 CERN P. Castro 1, M. Fernández 1, J. González.
Ultra-Fast Silicon Detector 1 This report is a summary of what was shown at IEEE. Nicolo Cartiglia, INFN, Torino - UFSD - RD50 CERN 2014 Nicolo Cartiglia.
1 Radiation hardness of neutron irradiated HVCMOSv3 Christian Gallrapp, Michael Moll CERN PH-DT-SSD Marcos Fernandez Garcia IFCA-Universidad de Cantabria.
3D Simulation Studies of Irradiated BNL One-Sided Dual-column 3D Silicon Detector up to 1x1016 neq/cm2 Zheng Li1 and Tanja Palviainen2 1Brookhaven National.
Rint Simulations & Comparison with Measurements
Radiation damage studies in LGAD detectors from recent CNM and FBK run
Radiation Damage TCAD Analysis of Low Gain Avalanche Detectors
Characterization and modelling of signal dynamics in 3D-DDTC detectors
First production of Ultra-Fast Silicon Detectors at FBK
Charge collection studies with irradiated CMOS detectors
Radiation Damage TCAD Analysis of Low Gain Avalanche Detectors
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Sep th Hiroshima Xi’an Test-beam evaluation of newly developed n+-in-p planar pixel sensors aiming for use in high radiation environment.
Position Sensitive TCT Measurements with 3D-stc detectors
HG-Cal Simulation using Silvaco TCAD tool at Delhi University Chakresh Jain, Geetika Jain, Ranjeet Dalal, Ashutosh Bhardwaj, Kirti Ranjan CMS simulation.
GLAST LAT tracker signal simulation and trigger timing study
Modeling Vacancy-Interstitial Clusters and Their Effect on Carrier Transport in Silicon E. Žąsinas, J. Vaitkus, E. Gaubas, Vilnius University Institute.
Hartmut F.-W. Sadrozinski, UFSD, 28th RD50 Meeting
TCAD Simulation of Geometry Variation under HPK campaign
Simulation of signal in irradiated silicon detectors
Peter Kodyš, Zdeněk Doležal, Jan Brož,
Semiconductor Detectors
Beam Test Results for the CMS Forward Pixel Detector
Enhanced Lateral Drift (ELAD) sensors
Status of CCD Vertex Detector R&D for GLC
Aras Papadelis NIKHEF Vertex 2005, Nikko, Japan
Gain measurements of Chromium GEM foils
Presentation transcript:

RD50 Workshop June 2016, Torino, Italy Silicon sensors with internal gain: Optimizing for charged particle fast timing Characterization of Deep Diffused APDs (non-irradiated) devices from RMD Ashutosh Bhardwaj (Delhi), Ranjeet Dalal1 (Delhi), Marco Fernandez Garcia (Santander), Geetika Jain (Delhi), Changuo Lu (Princeton), Michael Moll (CERN), Kirti Ranjan (Delhi), Sofia Otero Ugobono (CERN), Sebastian White (Princeton, CERN) OUTLINE: Concept of Deep Diffused APDs (“Hyperfast Detectors”) First measurements: Study on homogeneity of response Simulation of charged particle fast timing Outlook

Concept of Deep Diffused APD Deep Diffused APD from RMD (Radiation Monitoring Devices Inc.) n-type NTD-doped silicon from Topsil Grooving wafer Deep diffusion of p-type dopants Gallium used as dopant Etching of surface layer [2006, McClish et al., IEEE TNS, 53, 3049 ] [2004, McClish et al., IEEE TNS] M.Moll, RD50 Workshop, 7.6.2016, Torino

Charge Multiplication and Gain Deep Diffused APDs Amplification deep inside the bulk of the sensor Requires high voltage (1700-1800V) Delivers high gain and fast response time [2015, N.Cartiglia, DESY seminar] Comparison: Reach-through APD; LGAD TCAD Simulations Doping profile based on measured data (literature) used to simulate E-Field M.Moll, RD50 Workshop, 7.6.2016, Torino

Motivation: Time resolution References to previous work By SAMPIC team and S.White [D.Brenton et al., Elba conference 2015] RMD Mesh-APD VCSEL, 980nm; Amplifier: Wenteq, 50dB (316) gain SAMPIC system (Sampling rate = 6.4 GSample/s ) ~ 1 MIP ~ 15ps More details on previous work and collaboration working on the subject : S.White, CERN Detector Seminar, 25.09.2015 [ https://indico.cern.ch/event/439571/ ] M.Moll, RD50 Workshop, 7.6.2016, Torino

Homogeneity of response (Charge) Homogeneity scan on 2 RMD devices 2mm x 2mm RMD Deep Diffused APDs TCT with IR (1064 nm) pulsed laser - integration of pulse over 25ns Sample 01 [mounted not planar to PCB] 1700 V 1750 V 1800 V Sample 02 1700 V 1750 V Note: Different amplifier setting for sample 01 and 02 (arb. Charge values given) M.Moll, RD50 Workshop, 7.6.2016, Torino

“Charge collection” outside active area Signal observed outside active are of device 1700 V – IR laser The glue around the sensor causes the laser to reflect and enter the APD, thus explaining the charge collection observed outside the sensor. Signal disappears when Glue covered with tape M.Moll, RD50 Workshop, 7.6.2016, Torino

Pulse shapes IR laser pulses Red laser pulses (front illumination); “electron injection” Measurements: 10-1800V (10V steps) Sample 01 Sample 02 Sample 01 Sample 02 M.Moll, RD50 Workshop, 7.6.2016, Torino

APD with mesh for readout Proposed configuration for fast timing Deep Depleted APD with mesh readout (“Hyperfast Detectors”) [White at al. ] 2 Kapton layer thicknesses tested (2 and 5 mil, i.e. 51 and 127 mm) IR and Red laser scans performed at -1776V Mesh: connected to amplifier -1776 V GND Low resolution scan (100mm) High resolution scan (100mm) 15 μm 57 μm 49 μm Irradiation and further test to be done. M.Moll, RD50 Workshop, 7.6.2016, Torino

TCAD simulations (Silvaco) Device: Deep Diffused APD 200 mm thick APD (p-in-n) represented in simulator by 1x1x200 µm3 volume Error function deep diffused p-doping profile; bulk n-doping: 1.4 x 1014 cm-3 Junction at depth of 57 mm TCT with three different laser wavelength (670nm, 980nm, 1060nm) External circuit (Bias T) implemented for transient simulation Carrier lifetime set to 100ms; Charge integration for gain plots: 20ns Increasing bias: field extending towards n-side p+ n ~15µm on front side not depleted M.Moll, RD50 Workshop, 7.6.2016, Torino

TCT simulation TCT (front side illumination) [670nm, 980nm, 1060nm] Very fast initial peak for all wavelengths due to drift component of current For charge created in depleted layer Large (and slow) diffusion component for 670nm almost all charge deposited in un-depleted layer on front side (needs diffusion) M.Moll, RD50 Workshop, 7.6.2016, Torino

Dependence on bulk doping TCT simulation TCT (front side illumination) Very strong dependence on applied voltage and bulk doping concentration! Simulation predicts pulse length of 2-3ns Measurements showed slightly larger pulse length (approx. 4ns) Voltage dependence Dependence on bulk doping M.Moll, RD50 Workshop, 7.6.2016, Torino

TCT simulation Gain predictions Gain defined as: Signal with impact ionization / signal without impact ionization (It’s a simulation ) Higher bulk doping results in higher gain less depleted volume with higher E-Field Highest gain for lowest wavelength (higher fraction of generated carriers undergo amplification) 200mm APD thickness 200mm APD thickness M.Moll, RD50 Workshop, 7.6.2016, Torino

TCT simulation preliminary preliminary Simulated gain versus measured gain Gain for measured data (IR, red laser) defined as integrated signal / <integrated signal (1000V)> preliminary preliminary Simulation reproduces data trend (gain vs. voltage) quite well Need to normalize simulation data and measured data in same way Test measurements at 480nm provide a signal while the simulation with the present TCAD device model would give no signal at all for 480nm: Indication that the surface layer to the front is thinner than in the model, which however for the infrared laser measurements/simulations has no impact. M.Moll, RD50 Workshop, 7.6.2016, Torino

Simulation: Edge-TCT configuration Simulation parameters: Laser 1060nm, beam width 1 µm, 1ps risetime Depth position 1µm to 170µm (5 µm step) Junction depth: 57mm; Bulk doping (n-type): 1.4e14cm-3 5 mm 170 mm M.Moll, RD50 Workshop, 7.6.2016, Torino

Simulating energy-loss fluctuations Calculations based on two simulations: TCAD edge-TCT simulation provides wave forms for charges generated for every 5 mm slice of the detector. Bichsel charged particle energy straggling calculations Theory and Fortran code by H.Bichsel [Bichsel, Straggling in thin silicon detectors, 1988,Rev. Mod. Phys. 60, 663 ] Provides probability density function for a slice of 5 mm silicon 1 GeV muon, 5mm silicon [PDF provided by Su Dong, Stanford, USA] Histogram based on PDF PDF Voltage: 1800 V 16 positions (16 slices) Deposited Charge [KeV/5mm silicon] M.Moll, RD50 Workshop, 7.6.2016, Torino

Simulating energy-loss fluctuations Note that the Bichsel PDF for thin sensors is not a Landau Distribution ! For 5 mm Silicon & 1 GeV muon Histogram from Landau [PDF provided by Su Dong, Stanford, USA] 1 GeV muon, 5mm silicon based on [[Bichsel, 988,Rev. Mod. Phys. 60, 663 ] Landau fitted to Bichsel PDF Bichsel PDF Deposited Charge [KeV/5mm silicon] M.Moll, RD50 Workshop, 7.6.2016, Torino

Simulating energy-loss fluctuations Comparison of test beam data versus simulation [pulse heights distribution] Full size sensors 1 GeV muon preliminary 6 GeV pions, test-beam 2015 M.Moll, RD50 Workshop, 7.6.2016, Torino

Simulating energy-loss fluctuations Comparison of test beam data versus simulation [pulse heights distribution] 1 GeV muon preliminary 6 GeV pions, test-beam 2015 M.Moll, RD50 Workshop, 7.6.2016, Torino

Simulating energy-loss fluctuations Comparison of results [Prelimary] Comparing the different PDFs (Landau and Bichsel) result in significantly different time jitter Landau: 47 ps Bichsel: 30 ps Conclusion: Comparison with test-beam data needed. preliminary preliminary M.Moll, RD50 Workshop, 7.6.2016, Torino

Test beam ongoing Sunday 5.6.2016 Sensors with Sampic readout installed …. data for next RD50 1. Signal trace @ 1800V and 50 dB preamp with MCP-PMT signal 2. Setup showing both the Si telescope on right and the SAMPIC on the left M.Moll, RD50 Workshop, 7.6.2016, Torino

Conclusions and Outlook Previous works showed excellent timing performance ~15ps First measurements on Deep Diffused APDs performed at CERN SSD Some in homogeneities (up to factor 2) for collected charge seen over active surface ToDo: Perform same scan for time jitter Wider multiplication zone then in LGAD/standard APD devices Increased multiplication zone with high bias leads to the good timing performance ToDo: Understand optimum configuration of deep diffusion vs. bulk doping First simulation study on time jitter arising from energy-loss fluctuations performed using TCAD wave forms (e-TCT) and Bichsel or Landau PDFs Bichsel distribution vs. Landau distribution results in less time jitter All results obtained on non-irradiated devices Need to perform irradiation tests to study feasibility for high radiation environments! M.Moll, RD50 Workshop, 7.6.2016, Torino

Comparison: LGAD – DD APD TCAD simulation LGAD structure (with peak p-well doping of 9.75e16 cm-3, see R.Dalal last RD50) and thickness of 150 µm is used for simulation APD structure of 200 µm is used (depletion width ~ 140 µm) TCT signal evolution of APD and LGAD is compared TCT peak for LGAD is peaking after 1.8 ns (for example see blue curve for 1500V) TCT signal peak for APD is peaking after ~ 0.9 ns after laser fire Electrons from bulk have to move to front side p-well region for charge multiplication but in APD charge multiplication is happening around junction region. M.Moll, RD50 Workshop, 7.6.2016, Torino

E field for different bias E-field as function of bias With increase in bias, Depletion region mainly expand in backside bulk Should not expect much improvement with bias for front diffusion component ! No multiplication beyond about 100 micron depth (this number depends on bias) M.Moll, RD50 Workshop, 7.6.2016, Torino