SLAC National Accelerator Laboratory

Slides:



Advertisements
Similar presentations
Breakdown Rate Dependence on Gradient and Pulse Heating in Single Cell Cavities and TD18 Faya Wang, Chris Nantista and Chris Adolphsen May 1, 2010.
Advertisements

Single-Cell Standing Wave Structures: Design
CLIC08 workshop Structure production: CERN activities and Master Schedule G. Riddone, W. Wuensch, R. Zennaro, Contributions from C. Achard, S. Atieh, V.
Single cell standing wave tests data analysis Jiaru Shi Sep 27, 2011 LCWS11, Granada, Spain.
Research and Development for Ultra High Gradient Accelerator Structures at SLAC S. Tantawi For the SLAC team and collaborators.
PETS components and waveguide connections CLIC Workshop 2007 David Carrillo.
Interim Design Amy Eckerle Andrew Whittington Philip Witherspoon Team 16.
Development of an X-band Dielectric PETS C. Jing, Euclid Techlabs / ANL HG Workshop, May
Report from KEK High gradient study results from Nextef (+ other related activities) LCWS2011, Granada Sep. 27, 2011 T. Higo.
Effects of External Magnetic Fields on the operation of an RF Cavity D. Stratakis, J. C. Gallardo, and R. B. Palmer Brookhaven National Laboratory 1 RF.
Injector RF Design Review November 3, 2004 John Schmerge, SLAC LCLS RF Gun Thermal Analysis John Schmerge, SLAC November 3,
1 X-band Single Cell and T18_SLAC_2 Test Results at NLCTA Faya Wang Chris Adolphsen Jul
Dual Mode Cavity for Testing Effects of RF Magnetic field on Breakdown Properties A. Dian Yeremian, Valery Dolgashev, Sami Tantawi SLAC National Accelerator.
Design of Standing-Wave Accelerator Structure
R&D For Accelerating Structures H. Padamsee. TESLA Niobium, one meter length, rf = 1.3 GHz Copper, 53 cm, rf = 11.4 GHz.
Alessandro Cappelletti for CTF3 collaboration 5 th May 2010 RESULTS OF BEAM BASED RF POWER PRODUCTION IN CTF3.
High power RF capabilities From Two 50 MW Klystrons Variable iris Variable Delay line length through variable mode converter Gate Valves Two experimental.
W. Wuensch, rf development meeting Considerations on running normal conducting cavities cold.
HIGH RF POWER TESTING FOR THE CLIC PETS International Workshop on Linear Colliders 20 th October 2010 Alessandro Cappelletti for the CLIC team with.
201 MHz and 805 MHz Cavity Developments in MUCOOL Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory Nufact 2002 Workshop, London,
Particle-in-Cell Modeling of Rf Breakdown in Accelerating Structures and Waveguides Valery Dolgashev, SLAC National Accelerator Laboratory Breakdown physics.
201 MHz NC RF Cavity R&D for Muon Cooling Channels
日米協力 US/Japan cooperation Research of High Gradient Acceleration Technology for Future Accelerators progress report New proposal 7.
J. Haimson and B. Mecklenburg Haimson Research Corporation FG02-05ER84362 Work performed under the auspices of the U.S. Department of Energy SBIR Grant.
Materials Testing With a High-Q RF Cavity Sami Tantawi, Christopher Nantista, Valery Dolgashev, Gordon Bowden, Ricky Campisi, T. Tajima, and P. Kneisel.
Clustered Surface RF Production Scheme Chris Adolphsen Chris Nantista SLAC.
L-band (1.3 GHz) 5-Cell SW Cavity High Power Test Results Faya Wang, Chris Adolphsen SLAC National Accelerator Laboratory
1.3GHz Input Coupler for ILC
CLARA Gun Cavity Optimisation NVEC 05/06/2014 P. Goudket G. Burt, L. Cowie, J. McKenzie, B. Militsyn.
Test plan for SPL short cryomodule O. Brunner, W. Weingarten WW 1SPL cryo-module meeting 19 October 2010.
PBG Structure Experiments, AAC 2008 Photonic Bandgap Accelerator Experiments Roark A. Marsh, Michael A. Shapiro, Richard J. Temkin Massachusetts Institute.
Measurements of the X-ray/pump laser pulse timing Valery Dolgashev, David Fritz, Yiping Feng, Gordon Bowden SLAC 48th ICFA Advanced Beam Dynamics Workshop.
1 Al Moretti, APC, Fermilab MAP- Winter Meeting February 28 - March 4, 2011 TJNAF Newport News, VA.
The CLIC accelerating structure development program Walter Wuensch CARE05 23 November 2005.
The NLC RF Pulse Compression and High Power RF Transport Systems Sami G. Tantawi, G.Bowden, K.Fant, Z.D.Farkas, W.R.Fowkes J.Irwin, N.M.Kroll, Z.H.Li,
BEAMLINE HOM ABSORBER O. Nezhevenko, S. Nagaitsev, N. Solyak, V. Yakovlev Fermi National Laboratory December 11, 2007 Wake Fest 07 - ILC wakefield workshop.
Status of high gradient experiments at Nextef Kazue Yokoyama, Toshiyasu Higo, Yasuo Higashi, Shuji Matsumoto, Shigeki Fukuda Accelerator Laboratory, KEK.
KCS Main Waveguide Testing Chris Adolphsen Chris Nantista and Faya Wang LCWS12 Arlington, Texas October 25, 2012.
High-gradient rf constraints W. Wuensch X-band workshop
HLRF R&D Towards the TDR Christopher Nantista ML-SCRF Webex meeting June 29, 2011.
The US High Gradient Collaboration Vision for Research and Development on Ultra High Gradient Accelerator Structures Sami Tantawi, SLAC ( on behalf of.
Preparation procedure and RF processining of cERL-ML power coupler at KEK Hiroshi Sakai, Takaaki Furuya, Masato Sato, Kenji Shinoe, Kensei Umemori, Kazuhiro.
Study of Dielectric Loaded RF Cavity MAP MEETING - S EPTEMBER 23, 2011J ESSICA C ENNI.
Update on PETS experiments (Igor for the CLIC collaboration)
Update on SLAC experiments with High Gradient Accelerators and RF Components M.Franzi, V.A. Dolgashev, S. Tantawi June 6, 2016.
Superconducting Materials Testing With a High-Q Copper RF Cavity Sami Tantawi, Valery Dolgashev, Gordon Bowden, James Lewandowski, Christopher Nantista.
High Power Crab Cavity Testing Ben Woolley HG2016 Argonne National Lab. 8 th June 2016.
Advancements on RF systems D. Alesini (LNF-INFN) Quinto Meeting Generale Collaborazione LI2FE, Frascati 15-16/03/2011.
325 MHz Superconducting Spoke Cavity Coupler status. T. Khabiboulline Power Coupler design for Superconducting Spoke cavities. Originally.
Test Accelerating Structures Designs, Objectives and Critical Issues
Present and possible future schemes for hadron therapy linacs Alberto Degiovanni for the ADAM team HG2017 Workshop , Valencia.
Status and perspectives on X band structures at INFN-LNF
WP5 Elliptical cavities
NC Accelerator Structures
Application of the moderate peak power (6 MW) X-band klystron’s cluster for the CLIC accelerating structures testing program. I. Syratchev.
Review of rf structure test results
SPARC RF gun status by P. Musumeci Review committee
High Efficiency X-band Klystron Design Study
Recent high-gradient testing results from the CLIC XBoxes
CW Operation of XFEL Modules
CW accelerating module test progress at DESY
Dual mode bph 30 bph TMF TMR TMF TMR TEF TER.
CEPC Main Ring Cavity Design with HOM Couplers
Progress in the design of a damped an
H. Xu, M. A. Shapiro, R. J. Temkin
Cryomodules Challenges for PERLE
5th X-Band Structure Collaboration Meeting
T18_VG2.4_Disk_#2 processing summary
Accelerator Physics Particle Acceleration
Field-Emission mapping measurement on Copper Surface
Presentation transcript:

SLAC National Accelerator Laboratory Update on SLAC High-gradient Experiments with Cryogenic Normal-Conducting Cavities Valery Dolgashev, Alex Cahill, Stephen Weathersby, Andy Haase, Chuck Yoneda, Sami Tantawi SLAC National Accelerator Laboratory International Workshop on Breakdown Science and High Gradient Technology (HG2017) 13-16 June 2017, Instituto de Física Corpuscular (CSIC-University of Valencia), Valencia, Spain

11.4 GHz, Standing Wave-Structure 1C-SW-A5.65-T4.6-Cu-Frascati-#2 SLAC-KEK-INFN

Outline Motivation High Power test of 1C-SW-T2.75-A2.0-Cryo-Cu-#2 Understanding of dynamic Qo Breakdown rates at 45K

Single Cell SW and short TW Accelerating Structures Goals Study rf breakdown in practical accelerating structures: dependence on circuit parameters, materials, cell shapes and surface processing techniques Difficulties Full scale structures are long, complex, and expensive Solution Single cell standing wave (SW) structures with properties close to that of full scale structures Short traveling wave (TW) structures Reusable couplers We want to predict breakdown behavior for practical structures

Reusable coupler: TM01 Mode Launcher Pearson’s RF flange Cutaway view of the mode launcher Two mode launchers Surface electric fields in the mode launcher Emax= 49 MV/m for 100 MW S. Tantawi, C. Nantista

Current “state of the art” We practically can predict performance of heat-treated soft copper structures from drawings. We found peak pulse heating to be good predictor of breakdown rate in simple, disk-loaded-waveguide type geometries. We found “modified Poynting vector” to be a practical predictor of breakdown rate in more complex geometries. Motivated by correlation of peak pulse heating and breakdown rate we study hard cooper alloys and methods of building structures out of them. We found hard Cu and hard CuAg have better performance then soft heat-treated copper. As for now, hard CuAg had record performance for room temperature structures. We study clad metal and multi-layered structures and their construction methods. Idea is to study materials with designed properties. We started looking at process of initial conditioning: In 3 CuAg experiments (1 soft and 2 hard) we observed unusual conditioning: breakdown performance on initial stages of conditioning was better than at final stage. Note that at this final stage the performance is better then in common soft-copper structures. We study new methods of breakdown diagnostics and autopsy, specifically on ion-beam-milling and X-ray microscopy. We started looking at breakdown physics at 100 GHz frequencies and above We study breakdown in cryo normal conducting structures

Normal Conducting Cryogenic Structure We conjecture that the breakdown rate is linked to movements of crystal defects induced by periodic stress. Pulse heating creating some or, possibly major part of this stress. So, by decreasing crystal mobility and increasing yield stress we will reduce the breakdown rate for the same gradient. We want to do this by cooling a cavity to to 4…100 K. Pros: Resistivity decreased thus reducing rf power required to sustain the gradient. Thermal conductivity increases and thermal expansion decreases thus decreasing stress due to pulse surface heating Mobility of the crystals decreased, yield stress increases. Vacuum pumping between breakdowns is improved. Cons: Since the cavity acts as a cryogenic vacuum pump any vacuum leak or other source of gasses could contaminate high field surfaces. Due to reduced cooling efficiency at low temperature, overall efficiency of the system decreased and makes high repetition-rate operation problematic.

Precision Measurements of Metal Properties at Low Temperatures: Sami’s TE0 dome cavity Flat copper samples of varying purity and grain size. Goes down to ~3K. E H Sample R=0.95” Sami Tantawi, Jiquan Guo

Results for X-Band TE Dome Cavity Cu samples The copper samples were 6N and 7N purity with large and small grain sizes. One 7N sample was etched Notice that there is very small difference over a large range of samples Model for Q0 given by Reuter & Sondheimer (Proc. R. Soc. A. 1948) 7N Cu etched 7N Cu large grain sample 2 7N Cu large grain sample 1 7N Cu small grain 6N Cu Y. Higashi (KEK, OIST), Jiquan Guo, Sami Tantawi

1C-SW-T2.75-A2.0-Cryo-Cu, 11.3925 GHz 10 MW rf input (lossy 2nd order driven calculation) Maximum electric field 686 MV/m (SLANS 678 MV/m ) Maximum magnetic field 992.5 kA/m (SLANS 993.2 kA/m) Slightly over coupled with beta= 1.00488 Coupler-cell on-axis field is ~4% high vs. end-cell field, Peak field on axis 605.7 MV/m (SLANS 605.7 MV/m) F=11.3925 GHz (SLANS 11.9340 GHz) V.A. Dolgashev, SLAC, 14 March 2011

Design Qo, coupling and gradient vs. temperature Designed to be critically coupled at 96.15 K

Cryo structure setup with rf vacuum isolated from cryo vacuum cold head dark-current monitor brazed-in metal foil accelerating structure rf flange with crashed metal gasket stainless steel TM01 waveguide Cryostat assembly

Beadpull of 1C-SW-T2.75-A2.0-Cryo-Cu-#2 Power In Measured on-axis field profile Beadpull setup

forward fit reflected Fitting measured signals by changing Qo MV/m Eacc, T [arb. units.] Qloaded = 7200 Qloaded = 7961

Obtaining Qloaded from decay of downmixed reflected signal Amplitude of reflected signal Phase of reflected signal, raw data forward reflected dark current Qloaded = 7531 is consistent with fit of peak-power meter signals V.A. Dolgashev, SLAC, 18:22, 23 February 2015

Assuming design dependence of Qo vs Assuming design dependence of Qo vs. frequency, estimated temperature for Qo=15000 is 155 K while sensor shows 45 K Qo=15000@159K V.A. Dolgashev, SLAC, 23 February 2015

Performance of normal conducting cryo structure at 45 K assuming constant Qo from fitting of the power signals, not from temperature sensor, first breakdowns Cu@45K Hard CuAg#3 Hard CuAg#3 Soft Cu Soft Cu Hard Cu Hard Cu Hard CuAg#1 Hard CuAg#1 Cu@45K For the breakdown probability 10-3 .. 10-4 1/pulse/m cryo structure clearly outperforms record data from hard CuAg obtained in initial stages of conditioning. CuAg on final stages of conditioning very similar to hard Cu.

To find accelerating gradient, we need to understand the discrepancy between Qo measured by network analyzer and extracted from high power signals Method: Re-measure the cavity with a network-analyzer after processing Improved diagnostics and perform low- and High power measurements using klystron rf pulse

Results of Low Power Measurements Performed After High Power Test, 1C-SW-A2.75-T2.0-cryo-cu-SLAC-#2: Qo of accelerating structure is lower then Qo of dome cavity, but the difference is not as dramatic as expected from high power data Design Q0 Design Qe Measured Exp Qe Exp Q0 Design Design Qtot Exp Qtot Design parameters versus measured Matt Franzi, Jim Lewandowski

Q0 is Different for Different Modes in Processed 1C-SW-A2. 75-T2 Q0 is Different for Different Modes in Processed 1C-SW-A2.75-T2.0-Cryo-Cu-SLAC-#2 Model Prediction Q0 values in cryo cavity compared to copper in TE dome cavity and analytic value for max Q0 value We noticed that the increase in Q0 with temperature varies between the three modes (0, π, π/2) of the Cryo Cavity. We hypothesize this is due to damage from high power experiments: the π mode has highest field in center cell and has lowest Q0, π/2 has nearly no field in center cell and has the highest Q0 Design π π/2 π Data from above plot normalized to Q0 value at 250K to illuminate trends Model Prediction Design π π/2 π Matt Franzi, Jim Lewandowski

Study of Dynamic Qo Using Klystron RF Pulse We improved accuracy and dynamic range of rf diagnostics. With this improved diagnostics, we systematically measured Qo at both low- and high klystron power vs. temperature, repetition rate, pulse length, pulse shape, dark current. We build a circuit model of whole rf network, from klystron to cavity to understand its behavior. We build a circuit cavity model with Qo changing during the pulse. We fit the rf and dark current signals with this model using dramatic dependence of the dark current on surface fields as a field probe. We re-processed the rf breakdown data using this new model to find accelerating gradient.

Low power data matches constant Q0 circuit model; high power disagreement Model doesn’t match the measurement Model Measurement Measurement Measurement Measurement Model Model Low Power At low power the rf signals measured and calculated with a linear circuit model match. At higher power they clearly different. The example is for cavity temperature of 25 K, 10 Hz repetition rate, and shaped pulse with 500 ns flat part. A.Cahill et al., “Quality Factor in High Power Tests of Cryogenic Copper Accelerating Cavities” NAPAC 16

Calculating Accelerating Gradient With Time-Dependent Q0 Q0 and ω0, the resonant frequency, are allowed to vary during the rf pulse. The differential equation describing the electric field: Magnitude and rate of the Q0 decay is chosen to match the measured dark current and rf signals.

Processing History of 1C-SW-A2.75-T2.0-cryo-cu-SLAC-#2 Zoom in of the data used to calculate rf breakdown statistics Gradient calculated with nonlinear model A. Cahill et al., “Ultra High Gradient Breakdown Rates in X-Band Cryogenic Normal Conducting Rf Accelerating Cavities,” IPAC 17

Example Pulse From Breakdown Rate Measurement Shaped pulse with 150 ns flat part. Cavity temperature is 45 K. Average power during flat part of the pulse: 7.6 MW. Qo decreases from 30,400 to 19,700. Accelerating Gradient: 247 MV/m for linear model and 237 MV/m for model with dynamically changing Qo. Linear model Input Nonlinear model Reflected Measured RF power vs. time Dark current signal vs. time

Breakdown Rate Results using model with dynamic Qo to calculate the gradient, for first breakdowns Cu@45K Cu@45K Hard CuAg#3 Hard CuAg#3 Soft Cu Soft Cu Hard Cu Hard Cu Hard CuAg#1 Hard CuAg#1 Breakdown rate vs. gradient and peak surface electric for first rf breakdowns, 1C-A2.75-T2.0 structures, shaped rf pulse with 150 ns flat part A. Cahill et al., “Ultra High Gradient Breakdown Rates in X-Band Cryogenic Normal Conducting Rf Accelerating Cavities,” IPAC 17

Summary Results of systematic study of Qo change in cryogenic accelerating cavity confirmed very high accelerating gradients. As for now, these are accelerating cavities with best high gradient performance. The major part of Qo change is consistent with beam loading due to dark currents. It is possible that the other mechanisms of rf losses (say resistivity increase with temperature) are also present, but the strong dependence of dark current from surface fields, likely dominates.