Analisis Sistem Kendali Industri

Slides:



Advertisements
Similar presentations
EEEB443 Control & Drives Controlled Rectifier DC Drives By
Advertisements

Kazi Md. Shahiduzzaman Lecturer, EEE,NUB
Chapter 2 AC to DC CONVERSION (RECTIFIER)
ECE Electric Drives Topic 6: Voltage-Fed Converters Spring 2004.
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
ECE Electric Drives Topic 7: Pulse Width Modulation
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Three Phase Controlled Rectifiers
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
Copyright by UNIT-IV INVERTERS 4/16/2017 Copyright by
PHASE CONTROLLED CONVERTERS
ECE Electric Drives Topic 17: Wound-Field Synchronous
ECE Electric Drives Topic 11: Slip-Recovery Drives for
ECE Electric Drives Topic 10: Cycloconverters.
Fundamentals of Power Electronics 1 Chapter 19: Resonant Conversion Chapter 19 Resonant Conversion Introduction 19.1Sinusoidal analysis of resonant converters.
Power Electronics Chapter 6 AC to AC Converters ( AC Controllers and Frequency Converters )
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
LECTURE 9 INTRO TO POWER ELECTRONICS
Fundamentals of Electric Circuits Chapter 11
Chapter 4 AC to AC Converters
Introduction AC voltage controllers are thyristor based devices which convert fixed alternating voltage directly to variable alternating voltage without.
ECE Electric Drives Topic 10: Cycloconverters Spring 2004.
Alternating Current Circuits
ELECTRICAL CIRCUIT ET 201 Define and explain characteristics of sinusoidal wave, phase relationships and phase shifting.
Fundamentals of Electric Circuits Chapter 11
Topic 8: Simulation of Voltage-Fed Converters for AC Drives Spring 2004 ECE Electric Drives.
LECTURE 25 Controlled Rectifiers Dr. Rostamkolai
EE1301/POWER ELECTRONICS AC voltage controller and cycloconverter
Controlled Rectifiers (Line Commutated AC to DC converters)
LECTURE 26 Controlled Rectifiers Dr. Rostamkolai ECE 452 Power Electronics 1.
Rectifier A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which.
Bridge Rectifier Circuit with Working Operation and Their Types.
Full Wave Rectifier Circuit with Working Theory
C.K.PITHAWALLA COLLEGE OF ENGINEERING & TECHNOLOGY.-SURAT Prepared By: Brijesh Patel Viresh Dadia Fazal Ghanchi Vahora
PHASE CONTROLLED CONVERTERS
UNIT 4: SYNCHRONOUS MOTOR DRIVES
Full Wave Rectifier NavigationTutorial: 6 of 8 The Full Wave Rectifier In the previous Power Diodes tutorial we discussed ways of reducing the ripple or.
UNIT III DC Choppers.
Half-wave Rectifier.
Rectifiers, Inverters & Motor Drives
PHASE CONTROLLED CONVERTERS
Electronic Devices & Circuits
Sinusoidal Excitation of Circuits
Electric Machine Induction Motor
Induction motor control
AC to DC Converters Outline 2.1 Single-phase controlled rectifier
Converter principles and modelling
UNIT 4 CONTROLLED RECTIFIERS
DC- AC CONVERTER-INVERTER
APPLICATIONS Reference: Textbook-Chapter 6,8 & 9 'Power Electronics',C
Sinusoidal Waveform Phasor Method.
DC Choppers 1 MH1032/brsr/A.Y /pe/DC CHOPPERS
Power Electronic Drives - DC to AC converter / Inverter
Dr John Fletcher Thyristor Rectifiers Dr John Fletcher
UNIT-8 INVERTERS 11/27/2018.
Diode Rectifiers Chapter 5.
Switch-Mode DC-AC Inverters
Thyristor Converters Chapter 6
AC voltage controller and cycloconverter
ECE131 BASIC ELECTRICAL & ELECTRONICS ENGG
DC-DC Switch-Mode Converters
Thyristor Converters Chapter 6
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Diode rectifiers (uncontrolled rectifiers)
Alternating Current Circuits
C H A P T E R 11 A.C. Fundamentals.
Rectifiers. Introductions of rectifiers: IN PARTICLE ACCELERATORS, ELECTRONS OR OTHER CHARGED PARTICLES ARE FORCED TO MOVE ALONG ORBITS OR TRAJECTORIES.
INVERTERS. What is an Inverter? A static device that converts DC power into AC power at desired output voltage and frequency is called an Inverter. Applications.
Power Electronics Unit IV Prof. V. N. Bhonge
Presentation transcript:

Analisis Sistem Kendali Industri Cycloconverters

Introduction Cycloconverters directly convert ac signals of one frequency (usually line frequency) to ac signals of variable frequency. These variable frequency ac signals can then be used to directly control the speed of ac motors. Thyristor-based cycloconverters are typically used in low speed, high power (multi-MW) applications for driving induction and wound field synchronous motors.

Phase-Controlled Cycloconverters The basic principle of cycloconversion is illustrated by the single phase-to-single phase converter shown below.

Phase-Controlled Cycloconverters (cont’d) A positive center-tap thyristor converter is connected in anti-parallel with a negative converter of the same type. This allows current/voltage of either polarity to be controlled in the load. The waveforms are shown on the next slide.

Phase-Controlled Cycloconverters (cont’d)

Phase-Controlled Cycloconverters (cont’d) An integral half-cycle output wave is created which has a fundamental frequency f0=(1/n) fi where n is the number of input half-cycles per half-cycle of the output. The thyristor firing angle can be set to control the fundamental component of the output signal. Step-up frequency conversion can be achieved by alternately switching high frequency switching devices (e.g. IGBTs, instead of thyristors) between positive and negative limits at high frequency to generate carrier-frequency modulated output.

Phase-Controlled Cycloconverters (cont’d) 3 to single phase conversion can be achieved using either of the dual converter circuit topologies shown below:

Phase-Controlled Cycloconverters (cont’d) A Thevenin equivalent circuit for the dual converter is shown below:

Phase-Controlled Cycloconverters (cont’d) The input and output voltages are adjusted to be equal and the load current can flow in either direction. Thus, where Vd0 is the dc output voltage of each converter at zero firing angle and p and N are the input and output firing angles. For a 3 half-wave converter Vd0 =0.675VL and Vd0 = 1.35VL for the bridge converter (VL is the rms line voltage).

Phase-Controlled Cycloconverters (cont’d) Voltage-tracking between the input and output voltages is achieved by setting the sum of the firing angles to . Positive or negative voltage polarity can be achieved as shown below:

Phase-Controlled Cycloconverters (cont’d) A 3 to 3 cycloconverter can be implemented using 18 thyristors as shown below:

Phase-Controlled Cycloconverters (cont’d) Each phase group functions as a dual converter but the firing angle of each group is modulated sinusoidally with 2/3 phase angle shift -> 3 balanced voltage at the motor terminal. An inter-group reactor (IGR) is connected to each phase to restrict circulating current.

Phase-Controlled Cycloconverters (cont’d) An output phase wave is achieved by sinusoidal modulation of the thyristor firing angles.

Phase-Controlled Cycloconverters (cont’d) A variable voltage, variable frequency motor drive signal can be achieved by adjusting the modulation depth and output frequency of the converter. The synthesized output voltage wave contains complex harmonics which can be adequately filtered out by the machine’s leakage inductance.

Phase-Controlled Cycloconverters (cont’d) A 3 to 3 bridge cycloconverter (widely used in multi-MW applications) can be implemented using 36 thyristors as shown below:

Phase-Controlled Cycloconverters (cont’d) The output phase voltage v0 can be written as: where V0 is the rms output voltage and 0 is the output angular frequency. We can also write: where the modulation factor, mf is given by:

Phase-Controlled Cycloconverters (cont’d) From these equations, we can write: and Thus for zero output voltage, mf=0 and P= N= /2. For max. phase voltage, mf=1 => P=0, N= . See below figure for P and N values for mf=0.5 and 1.

Phase-Controlled Cycloconverters (cont’d) The phase group of a cycloconverter can be operated in two modes: 1) Circulating current mode 2) Non-circulating current (blocking) mode In the circulating current mode, the current continuously circulates between the +ve and -ve converters. Although the fundamental output voltage waves of the individual converters are equal, the harmonics will cause potential difference which will result in short-circuits without an IGR.

Phase-Controlled Cycloconverters (cont’d) The equivalent circuit of a phase group with an IGR is shown below. The inclusion of an IGR leads to self-induced circulating current as illustrated in the next slide.

Phase-Controlled Cycloconverters (cont’d)

Phase-Controlled Cycloconverters (cont’d) At t=0, +ve load current is taken by the +ve converter only (iP=i0). From 0->/2, rising +ve load current will create a +ve voltage drop (vL=Ldi0/dt) in the primary winding of the IGR. This creates a -ve voltage drop in the secondary winding of the IGR -> DN reverse biased.  no current flow in the -ve converter. At /2, i0 peaks at Im-> vL=0. After this vL tends to reverse polarity inducing current in the -ve converter. Voltage across IGR becomes clamped to 0 -> self-induced circulation current between +ve and -ve converters.

Phase-Controlled Cycloconverters (cont’d) The +ve and -ve converter currents can be expressed as: The self-induced circulating current is simply iP-iN. In practice, the waves will not be pure sine waves but include a ripple current. Practical waveforms are shown on the next slide.

Phase-Controlled Cycloconverters (cont’d)

Phase-Controlled Cycloconverters (cont’d) Advantages of circulating current mode of operation, over blocking mode include: Output phase voltage wave has lower harmonic content than in blocking mode. Output frequency range is higher. Control is simple. Disadvantages Bulky IGR increases cost and losses. Circulating current increases losses in thyristors. Over-design increases cost.

Phase-Controlled Cycloconverters (cont’d) In the blocking mode of operation, no IGR is used and only one converter is conducting at any time. Zero current crossing detection can be used to select +ve or -ve converter conduction as shown below:

Phase-Controlled Cycloconverters (cont’d) Since the cycloconverter is usually connected directly to a motor, the harmonics from the converter will induce torque pulsations and machine heating resulting in increased machine losses. Also, since the cycloconverter is essentially a matrix of switches without energy storage (neglecting IGR) Pin=Pout . Thus distortions in the output voltage waveform reflect back into the line input. See text for a discussion of the load voltage and line harmonics.

Phase-Controlled Cycloconverters (cont’d) A major disadvantage of cycloconverters is poor DPF (displacement power factor). To calculate DPF, consider a phase group of an 18-thyristor cycloconverter shown below.

Phase-Controlled Cycloconverters (cont’d) Assume the +ve converter is operating in continuous conduction and is connected to a high inductance load and assume that the cycloconverter is operating at low frequency. Segments of the output current and voltage waves are as shown below:

Phase-Controlled Cycloconverters (cont’d) The Fourier series of the line current is given by: where i0 is the load current and  is the supply frequency. The current wave has a dc component and a fundamental component with a lagging phase angle, P.

Phase-Controlled Cycloconverters (cont’d) Since the supply’s active and reactive power components are contributed only by the fundamental current, the instantaneous active Pi’ and reactive power Qi’ for the positive converter is given by: where Vs =rms line voltage.

Phase-Controlled Cycloconverters (cont’d) These equations can be rewritten as: If the firing angle is constant, the converter acts as a rectifier and Vd=Vd0cosP and i0=Id. In a cycloconverter P and i0 vary sinusoidally and so Pi’ and Qi’ are also modulated. We need to average these parameters to determine loading on the source.

Phase-Controlled Cycloconverters (cont’d)

Phase-Controlled Cycloconverters (cont’d) The expression for the average reactive power contributed by the line, Qi, is given by: where = load power factor angle. Performing the integration above yields: where P0, Q0 are the real and reactive output power per phase, respectively.

Phase-Controlled Cycloconverters (cont’d) P0 and Q0 are given by: and Since the real output power = real input power, we can write: The input DPF can be expressed as: DPF = cosi =

Phase-Controlled Cycloconverters (cont’d)  DPF = = where tan = Q0/Pi (=Q0/P0)

Phase-Controlled Cycloconverters (cont’d) This equation for DPF applies when additional phase groups are added or if a 36-thyristor implementation is considered. mf=1 was assumed in this derivation. For mf 1: The maximum value of line DPF is 0.843.

Phase-Controlled Cycloconverters (cont’d) See Bose text pp. 180-184 for methods to improve DPF.

Phase-Controlled Cycloconverters (cont’d) The control of a cycloconverter is very complex. A typical variable speed constant frequency (VCSF) system is shown below:

Phase-Controlled Cycloconverters (cont’d) Generator bus with regulated voltage but variable frequency (1333-2666 Hz) is fed to the cycloconverter phase groups. (A generator speed variation of 2:1 is assumed). The dual converter in each phase group uses a low-pass filter to generate a sinusoidal signal.  modulator receives biased cosine waves from generator bus voltage and sinusoidal control signal voltages to generate thyristor firing angles.

Phase-Controlled Cycloconverters (cont’d) 3 sinusoidal control signals are generated through the vector rotator. The feedback voltage Vs is generated from the output phase voltages.

Phase-Controlled Cycloconverters (cont’d) Details of  modulator are shown below:

Matrix Converters These types of cycloconverters use high-frequency, self-controlled ac switches (e.g. IGBTs). A 3 to 3 converter is shown below:

Matrix Converters (cont’d) A matrix of nine switches where any input phase can be connected to any output phase. The switches are controlled by PWM to fabricate an output fundamental voltage whose amplitude and frequency can be varied to control an ac motor. The output waveform synthesis is shown on the next slide.

Matrix Converters (cont’d)

Matrix Converters (cont’d) Matrix converters offer the advantage over thyristor cycloconverters of being able to produce unity PF line current. However, compared to PWM voltage-fed converters, the parts count is significantly higher.

High-Frequency Cycloconverters See Bose text pp. 186-189