Rotation Target R and D of ILC E-driven source

Slides:



Advertisements
Similar presentations
CO2 cooling for FPCCD Vertex Detector Yasuhiro Sugimoto KEK 1.
Advertisements

Overview of 300 Hz Conventional e + Source for ILC Truly Conventional Collaboration ANL, IHEP, Hiroshima U, U of Tokyo, KEK, DESY, U of Hamburg NIM A672.
Status of KEK production July 11, 2008 at SLAC KEK T. Higo et al., Accelerator div. T. Takatomi et al., Mech. Eng. Center.
Tungsten wire & VISAR Goran Skoro 24 October 2008.
Status of T2K Target 2 nd Oxford-Princeton High-Power Target Workshop 6-7 th November 2008 Mike Fitton RAL.
WP2: Detector development Summary G. Pugliese INFN - Politecnico of Bari.
Radiation Cooling of the ILC positron target LCWS 2014, Belgrade, Serbia 7 th October 2014 Sabine Riemann, DESY, Peter Sievers, CERN/ESS, Andriy Ushakov,
Vacuum system in the main Linacs C. Garion CERN/TE/VSC CLIC09 workshop, October.
9-cell Nb cavity seminar Dec.01, 2009 Facilities for 9-cell Nb cavities.
1 T2K Beam Operation Summary (earthquake recovery and beamline survey) NBI 2012 T. Ishii (KEK) for the T2K beam group.
Cavity status; recent KEK activities : Hayano (1) STF CM-1 cavities are; MHI-014: 3-rd VT:36MV/m (finished) MHI-015: 3-rd VT: > 18.4MV/m.
Design of electrostatic septum for slow extraction from J-PARC main ring 2005, March 2nd ICFA septa workshop 2005 Acc. Lab., KEK M. Tomizawa, Y. Arakaki,
Malte HildebrandtDC Status Report, Dear MEG Committee,PSI, April 14 th 2009 this is the first report concerning the drift chamber status as.
1 Positron Target R&D at KEK Plan and Status AD&I Meeting 2009/8/27 KEK Hybrid Target Test at KEKB Linac Liquid Lead Target Test at ATF Linac Window Test.
STF EP, VT commissioning by FNAL AES001 H. Hayano, KEK
The Fate of the Universe
Conventional e + Source Rotation Target R/D T. Omori (KEK) ANL, IHEP, Hiroshima U, U of Tokyo, KEK, DESY, U of Hamburg, CERN 3-Sep-2015 POSIPOL 2015, Cockcroft.
Key luminosity issues of the positron source Wei Gai.
Positron Source General Update M. Kuriki(Hiroshima U./KEK) ALCW2015, April 2015,Tsukuba/Tokyo, Japan.
Date processing and conversion Please use speaker notes for additional information!
HEC strange signals 1 09 Feb 2012 E.Ladygin Status of HEC spikes study in Protvino E.Ladygin, M.Kazarinov, A.Kozelov.
ATF2 Accelerator Status and Plans for JFY 2014 runs N. Terunuma, KEK.
A Report from PosiPol2015 to AD&I meeting (10 Sep. 2015) Masao KURIKI (Hiroshima University)
Conventional e + Source Rotation Target R/D T. Omori (KEK) ANL, IHEP, Hiroshima U, U of Tokyo, KEK, DESY, U of Hamburg, CERN 3-Nov-2015 LCWS 2015, The.
F.Staufenbiel / EuCARD 2 / Heat load and stress studies of the ILC collimator G. Moortgat-Pick 1;2 S. Riemann 2, F. Staufenbiel 2, A. Ushakov.
Target studies for the ILC 300 Hz conventional e + source 29-May-2013 ECFA LC Workshop at DESY T. Omori Target study team: K. Yokoya (KEK), J. Urakawa.
T2K Remote Handling T. Sekiguchi (KEK) on behalf of Tada (KEK) 2012/11/10.
Rotating Vacuum Seal Learning from Experiences of SLC and NLC T. Omori (KEK), with many thanks to Marc-san 28 March 2010, ILC10&LCWS10 at Beijing.
Simulation of heat load at JHF decay pipe and beam dump KEK Yoshinari Hayato.
MHI#16 号機の2回目の EP2  Process log  Status of working  Monitor data during EP & Rinsing process  Comparison of EP2 Period : 2011/5/10 ~ 5/16 Process :
Present status of production target and Room design Takashi Hashimoto, IBS/RISP 2015, February.
MHI#19 号機の1回目の EP2  Process log  Condition of EP2 & Rinsing process  Status of working  Monitor data during EP & Rinsing process Period : 2012/2/17~
Methane Update and Run Plan Ben Jones. Configuration 8 inch PMT with TPB plate - 8” from alpha source - Now includes magnetic shield - 2 inch PMT without.
Design for a 2 MW graphite target for a neutrino beam Jim Hylen Accelerator Physics and Technology Workshop for Project X November 12-13, 2007.
SF6 contamination by air in the Pelletron Recycler Departmental Meeting November 5, 2008 A. Shemyakin.
0 Ion Beam Facilities at KOMAC Chan Young Lee on behalf of KOMAC Chan Young Lee on behalf of KOMAC ICABU2014, November 12~14,
325 MHz Superconducting Spoke Cavity Coupler status. T. Khabiboulline Power Coupler design for Superconducting Spoke cavities. Originally.
2007/09/17 SLAC IRENG07 1 Comment on IR Vacuum system Y. Suetsugu Pumping System without in-situ baking at z < L*
Summary of STF-EP facility at KEK.
Masao KURIKI (Hiroshima University)
Performance test of KAGRA cryostat at site
POSIPOL 2016 at LAL/Paris, Sept Peter Sievers-CERN
2016/12/6 Yasuhiro R&D status of a gas-compressor based 2-phase CO2 cooling system for FPCCD vertex detector 2016/12/6 Yasuhiro Sugimoto.
A Positron Target Concept for the ILC
CW couplers; KEK injector couplers Eiji Kako (KEK, Japan)
Cryogenic behavior of the cryogenic system
Olathe South ACT Timeline
Chamber Dynamic Response Modeling
Pair-Production Target
Rotation Target R and D of ILC E-driven source
Performance test of KAGRA cryostat at site
S0 Status report from KEK
The SABRE Crystals Frank Calaprice.
Third Workshop on GEMs for CMS
Target and Horn status report
Replacement of coupler and recovery of cavity for BEPCII
COSMO Priority Project ”Quantitative Precipitation Forecasts”
Toward the final design of a TPC for the ILD detector
Beam Dump outline work plan (UK perspective)
Ageing workshop - N.Tuning
TPC Paul Colas Technical meeting, Lyon.
IBBelle: Status Commissioning at MPP Transport to KEK
Summary for the Sources working group
FY 2019 Close Schedule Bi-Weekly Payroll governs close schedule
Lithium lens and window tests
CFS consideration on the Main Dump and around
Advanced Research Electron Accelerator Laboratory
Cavity-Compton Regular Meeting design report summary
CNGS horn / reflector in 2005: The story of the glass ring insulator
Cryogenic behavior of the magnet
Presentation transcript:

Rotation Target R and D of ILC E-driven source ferromagnetic fluid seal air vacuum T. Omori (KEK), 26-October-2017 LCWS 2017 October 23-27, 2017, Convention Center, Strasbourg, France

Target Positron Electron W-Re 16mm thick. 5 m/s tangential speed rotation (225 rpm, 0.5m diameter) in vacuum. Water cooling through channel. Vacuum seal with ferro-fluid.

Vacuum Test of the Prototpe

Prototype of the Rotation Target (E-driven) Central Part hollow shaft motor baring ferrofluid seal vacuum chamber disk • d= 500 mm • wait ~ 70 kg • no water channel finished in FY2015

Central Part Prototype Vacuum Test Feb/2017 Vacuum chamber Ion pump 100 litter/sec Central part prototype Central Part Prototype: Funded by KEK Vacuum Test: Funded mostly by Hiroshima Univ.

Central Part Prototype Vacuum Test Facts and What happened (1) • Ion pump 100 litter/sec. • Rotation at 225 rpm (design value). • We started the experiment on February 9th.

Central Part Prototype Vacuum Test Log (Pressure) [Pa] 9/Feb 16/Feb 23/Feb   2/Mar 9/Mar 16/Mar 23/Mar Date 225 rpm (design value) 1x10-5 3x10-6 4x10-6 2x10-5 5x10-6 The test started on February 9th with continuous rotation at 225 rpm 3x10-6 Pa The vacuum test started on February 9th with continuous rotation at 225 rpm (design value). The vacuum level seems to be reasonable in comparison with the expectation. The vacuum level is as good as the ILC TDR requirement. It seems promising. But the prototype has no disk. We will make further study.

Central Part Prototype Vacuum Test 225 rpm February/13 – March/28 Pressure [Pa] x10-6 Note: Linear scale Date 13/Feb 23/Feb 5/Mar 15/Mar 25/Mar 4/Apr 3x10-6 Pa 7 7 6 6 5 5 4 4 3 3 225 rpm

Central Part Prototype Vacuum Test Facts and What happened (1) • Ion pump 100 litter/sec. • Rotation at 225 rpm (design value). • We started the experiment on February 9th. • Vacuum level went good monotonically. • And reached ~ 3x10-6 Pa at the end of March.

Central Part Prototype Vacuum Test Small spikes (x1.5 – x 2) were obsreved March/28 – May/09 225 rpm 9 x2 April 10th 7 Pressure [Pa] x10-6 Note: Linear scale x1.5 5 4x10-6 Pa 3x10-6 Pa 3 1 28/Mar 7/Apr 17/Apr 27/Apr 7/May 17/May Date 225 rpm

Central Part Prototype Vacuum Test Facts and What happened (1) • Ion pump 100 litter/sec. • Rotation at 225 rpm (value). • We started the experiment on February 9th. • Vacuum level went good monotonically. • And reached ~ 3x10-6 Pa at the end of March. • Vacuum level was stable at ~ 3x10-6 until April 10th. • Then, we observed small spikes. - Height of a spike ~x1.5.

Vacuum Test: ILC Rotation Target Facts and Concerns at the Prototype Vacuum 3x10-6 Pa (measurement results) Keep good vacuum over five months Sikes Vacuum level slowly went worse. Concerns Sikes Aging Contamination of the accelerator tube

Estimation in ILC e+ source system *Data measured by the central part prototype (experiment) Vacuum 3x10-6 Pa (mesurement results) Vacumm pump used 100 L/s (=100x10-3 m3/sec)(Ion pump) *Leak rate (calculated from the above) (3x10-6 Pa) x (100x10-3 m3/sec) = 3x10-7 Pa m3/sec *Estimate expected vacuum levels and gas flows at 1st acc-tube in ILC e+ source system by using the leak rate.

The Model Aperture D=16 mm Vacuum Pump 400 L/sec FC Acc. tube(L=1.1 m, Airis 60 mm) Gap 5 mm Target disk Central part of the target Target vacuum chamb Ferrofluid Seal Unit Gas Source 3x10-7 Pa m3/sec Gap 5 mm Vacuum Pump   1000 L/sec

The Model Conductance 11.6 L/s Aperture D=16 mm Vacuum Pump 400 L/sec FC Acc. tube(L=1.1 m, Airis 60 mm) Conductance 23.7 L/s Gap 5 mm Target disk Central part of the target Target vacuum chamb Ferrofluid Seal Unit Gas Source 3x10-7 Pa m3/sec Gap 5 mm Vacuum Pump   1000 L/sec Conductance 306 L/s

The Results Vacuum Pump 400 L/sec FC Acc. tube(L=1.1 m, Airis 60 mm) gas flow 0.09x10-7 Pa m3/s (2.3x1012molecules/s) 4x10-7 Pa 2.4x10-8 Pa Target disk Central part of the target Target vacuum chamb Ferrofluid Seal Unit Gas Source 3x10-7 Pa m3/sec 1.2x10-6 Pa gas flow 2.91x10-7 Pa m3/s Vacuum Pump   1000 L/sec 2.9x10-7 Pa

Estimation in ILC e+ source system *Data measured by the central part prototype (experiment) Vacuum 3x10-6 Pa (mesurement results) Vacumm pump used 100 L/s (=100x10-3 m3/sec)(Ion pump) *Leak rate (calculated from the above) (3x10-6 Pa) x (100x10-3 m3/sec) = 3x10-7 Pa m3/sec *Estimate expected vacuum levels and gas flows by using the leak rate *Estimate contamination by the ferrofluid. Assumption: All "leak" is due to evaporation of the fluid. We assume the worst case. In reality, there are three possible causes for the "leak".    (a) evaporation of the seal fluid.   (b) air leak via the seal   (c) Degassing from the surface

Absorption of the gas on the surface (Cu) of the accelerator tube Gas flow in the accelerator tube (see the previous page) 2.29x 1012 molecules s-1 Cu atom surface density (1/m2) 1.19 x 1012 m-2 Total inner surface area of the accelerator tube 1.09 m2 Gas absorption rate on the surface α Note: We assume all gas comes to the accelerator tube are absorbed on the surface. -> We assume the worst case. Gas removal rate from the surface β Ea=100 keV activation energy ν = 1013 frequency factor β = 3.85x10-5

Absorption of the gas on the surface (Cu) of the accelerator tube Covering rate η :Differencial Eq. and the Solution: Answer Covering rate at Equilibrium   η(t=∞) = 2.7x10-3 ( 0.27% ) Days to reach equilibrium   1/β = 110 days Conclusion The covering is far smaller than single molecule layer (Covering rate 0.27%) Note: The answer and the conclusion are based on the assumption that the measured "leak" rate is fully due to the evaporation of the seal fluid. But this is NOT true. The evaporation is only a very small part of the "leak". The actual situation should be much better.

Evaporation of the Fluid? The dominant cause of the "leak" is NOT the evaporation. *Evidence 1: • If the leak rate "3x10-7 Pa m3/sec" (measured value) is dominantly caused by the evaporation, the evaporation speed is estimated to be 1.2 x 10-10 mol./sec • Since very small amount of the fluid (less than ml ) is used in the prototype, if evaporation proceeds at the rate all the fluid gone in two months. • However, the seal keeps good vacuum over five months. - -> The evaporation speed is much more slower than the estimated vale.

We Opened the prototype and made observation July 19th

Evaporation of the Fluid? The dominant cause of the "leak" is NOT the evaporation. *Evidence 2: • We opened the chamber of the prototype on 19th July. And observed inside by eyes. • No damage of the fluid was observed by eyes. Even small amount of disappearance of the fluid was observed. If there is evaporation, we will see powders of dried fluid. • Before the opening, we expected to see the powders at some stages of the seal (seal has 20 stages in total) near the vacuum. But we observed healthy fluid even at the inner most stage.

Evaporation of the Fluid? The dominant cause of the "leak" is NOT the evaporation. *Evidence 1: • Data: Residual Gas Analyzer (RGA w/multiplyer) Log 1 18 28 32 40 44 69 • If the fluid (macromolecule) is evaporated, it is expected to observe the fragments of the macromolecules of the fluid. • However NO such objects were observed at high mass rang in the RGA data.

Contamination by the ferrofluid? Conclusion: (1) Estimation with worst case assumption (#) shows that covering by the fluid is 0.27% #All "leak" measured in the test is due to evaporation of the fluid. (2) The assumption is NOT true. We did not observe an indication of the evaporation. (3) We do not worry about the contamination by the ferrofluid. (4) It seams that the "leak" is mostly leak of the air. Continuous leak of air may cause contamination?

Reinstallation of the Seal Unit (1) We opened the chamber 19th July. (2) The seal unit was sent back to the company (RIGAKU). The company checked the unit, washed the unit, and applied fresh ferrofluid. (3) We reinstalled the unit on 31st July.

July 31st: We reinstalled the seal unit and closed the chamber again

July 31st: We reinstalled the seal unit and closed the chamber again

July 31st: We reinstalled the seal unit and closed the chamber again

Reinstallation of the seal unit    31st July AM:reinstallation, pumping(turbo), baking start           PM: baking 2nd Aug. AM:stop baking 4th Aug. Evening: all instruments stop • KEK scheduled power shut down:5th-6th Aug. • 8th Aug. Moring: pumping(turbo) restart Evening: baking start • 8th Aug. PC(Windows XP) for RGA Broken • 9th Aug. Air Conditioner in the room Broken • 10th Aug 16:31 Baking stop        19:15 pumping start by the ion pump  • KEK Summer Holidays: 11th(Fri), 12nd(Sat), 13rd(Sun), 14th(Mon), 15th(Tue), 16th(Wed), Aug. 17:36 restart rotation

Vacuum Test: After reinstallation Aug/12 17:36 Rotation restart 10 8 6 Pressure [Pa] x10-6 Note: Linear scale 4 2 11 05:55 11, 15:55 12, 01:55 12, 11:55 12, 21:55 0 rpm 225 rpm Aug/12 17:36 Rotation restart

Facts, obstacles, and concerns • Reinstallation of the seal unit: 31st July • KEK scheduled power shut down:5th-6th, Aug. • Air-conditioner of the room broken: 9th Aug. - NOT scheduled. - New air-conditioner was installed in the middle of September. - Experiment after the reinstallation was performed in no good environment • PC for RGA readot broken: 8th Aug. - NOT scheduled. - Old PC (Windows XP) for old RGA • KEK Summer Holidays:11th-16th, Aug. • We observed spikes again in the operation after the reinstallation.

Spikes • We observed spikes again in the operation after the reinstallation. • Spikes appeared immediately after restart of operation. cf. Spikes appeared after 3 months of operation in the first experiment in Febuary-July). • In the first experiment, we suspected the aging of the ferrofluid was the cause of the spikes. But in the second experiment we observed spikes immediately. • Quality control is the cause?.

Quality Control? (1) The seal unit was carried from the company to KEK with no protection to atmoshere in mid- summer in Japan. Maybe the ferrofluid absorbed water in the atmosphere? (2) Maybe reinstallation work in KEK (NOT in the company) caused an issue in the quality control?

New Tests Planned • The new test of the prototype. • The new test of the ferrofluid. • Re-reinstall the seal unit.

New Tests of Prototype is Planned We are planning to introduce the gas flow at the air side of the rotation seal. Purpose: (1) Track the cause of "leak". • Is it leak from outside? • The "leak" comes from inside the fluid, for example water contamination of the fluid? We are going to make Ar gas flow. (2) Control the environment at outside of the seal. Preparation: We covered openings by rubber plates. First Test: We will start the test at the begging of November with Ar gas follow.

New Tests of Prototype is Planned Gas flow at the air side Preparation: Cover openings by rubber plates before covering after covering

New Tests of Ferrofluid Planned Advanced Radiation Research In Past: November 2014 TEST was done: Radiation Tolerance Takasaki Advanced Radiation Research Institute, JAEA The seal dosed 4.7 MGy (3 ILC year) is examined. Rotation : 0-600 rpm. No leak was found. GOOD! But, viscosity increased, and we don't know the cause. (We have guess) Near Future: December 2017 Liquid chromatograph analysis of the fluid before and after irradiation is planed. 10-Nov-2014

TEST: Radiation Tolerance In Past TEST: Radiation Tolerance November 2014 More systematic study for CN oil FY2014 Dose [MGy] Viscosity Viscosity as a function of dose 4.7 MGy The seal dosed 4.7 MGy (3 ILC year) is examined with Ar purged chamber. Rotation : 0-600 rpm. No leak was found.

Facts and Near Future Plan • Reinstallation of the seal unit: 31st July • KEK scheduled power shut down:5th-6th, Aug. • Air-conditioner of the room broken: 9th Aug. • PC for RGA readout broken: 8th Aug. • KEK Summer Holidays:11th-16th, Aug. • We observed spikes again in the operation after the reinstallation. • New air-conditioner installed: Mid. Sep. • RGA broken: 12nd Oct. • RGA resumed somehow: 16th Oct. • Ar-gas flow: End of Oct. – Begging of Nov. • New radiation test of ferrofluid: Middle of Dec.

Summary

Summary (1) Up to today • Long term test was performed (Feb. 9th – July 19th). • 3-5x10-6 Pa is kept with 225 rpm rotation with 100 l/s ion pump. • The vacuum level is the same as expected. • It seams promising. • Vacuum levels and gas flows at 1st acc-tube is estimated. It is promising too. • However we still have some concerns. - Spikes. - Aging? of the ferrofluid. - Quality contorol. • We were/are suffered from many broken equipments. Most of them are old, except the target prototype.

Summary (2) Near future • Introduce the gas flow at the air side of the rotation seal. First, Ar-gas: It will start end of Oct. or Beginning of Nov. • Liquid chromatograph analysis of the fluid before and after irradiation: It will be done Mid. of Dec. • Re-reinstallation of the seal unit is planned.

Backups

R/D of the Slow Rotation Target of the Conventional e+ Source Today’s Talk R/D of the Slow Rotation Target of the Conventional e+ Source for ILC • Target R/D (1): Heat&Stress Simulations, and Radiation Test • Target R/D (2): Vacuum Test of the Prototype • Summary

Heat&Stress Simulations and Radiation Test

Simulation : target stress and cooling Pulse#02 225rpm Pulse beam analysis: step 2 20 trains (pulses) in 63 ms Temp.Max.; 356.0℃ Max-Stress (Von-Mises): 470 MPa Stress: OK Cooling: OK Max-Stress is as same as that of SLC target. SLC target worked in 3-4 years. Number of hit / Year.mm NILC = NSLC/10  Fatigue: ILC is 10 times better than SLC Nb = 2600 Simulated by Rigaku Cooling water: 60 l /min

Conventional (E-driven): Target T. Omori

Central Part Prototype Vacuum Test Small spikes (x1.5 – x 2) were obsreved March/28 – May/09 225 rpm 9 x2 April 10th 7 Pressure [Pa] x10-6 Note: Linear scale x1.5 5 4x10-6 Pa 3x10-6 Pa 3 1 28/Mar 7/Apr 17/Apr 27/Apr 7/May 17/May Date 225 rpm

Central Part Prototype Vacuum Test Close-up of the small spikes 225 rpm 2 hours 3.5x10-6 Pa x1.5 1 3 5 7 9 Pressure [Pa] x10-6 Note: Linear scale Apr/21, 7:46 – Apr/22, 03:46 225 rpm

Central Part Prototype Vacuum Test Enhancement of the Water Cooling Channel Before Enhancement OUT IN

Central Part Prototype Vacuum Test Enhancement of the Water Cooling Channel Before Enhancement OUT IN Rotating Water Seal and Inside the Shaft are cooled

Central Part Prototype Vacuum Test Enhancement of the Water Cooling Channel After Enhancement IN OUT IN OUT IN OUT

Central Part Prototype Vacuum Test Enhancement of the Water Cooling Channel After Enhancement IN OUT IN OUT IN OUT Rotating Water Seal, Inside the Shaft, Motor, and Near Ferrofuild Seal are cooled

Central Part Prototype Vacuum Test We added thermocouple at near the ferrofluid seal

Central Part Prototype Vacuum Test Enhancement of the Water Cooling Channel After Enhancement