Fig. 3. Bland-Altman plots of CAC scores between TNC image and MDW (A), MDC (B), MSI (C) images. Mean CAC score from TNC image and VNC images is plotted.

Slides:



Advertisements
Similar presentations
May 12-15, 2011 (red) May 6-11, 2011 (light red) Permanent Water (blue)
Advertisements

STRETCHES AND SHEARS.
Continuous Noninvasive Hemoglobin Measurement Is Useful in Patients Undergoing Double-Jaw Surgery  Sung-Hoon Kim, MD, Jae Moon Choi, MD, PhD, Hyun Jeong.
Feasibility of wall stress analysis of abdominal aortic aneurysms using three- dimensional ultrasound  Annette M. Kok, MSc, V. Lai Nguyen, MD, Lambert.
Fig. 2. Concept of fractional flow reserve
Fig. 1. Luminal A type breast cancer of 37-year-old woman. A
Fig. 2. Triple negative type breast cancer of 37-year-old woman. A
Fig. 7. Suspicious lymph nodes (CT features). A
Fig. 1. Lung-RADS categories rearranged by Korean Imaging Study Group for Lung Cancer according to nodule type, size, and interval change. Solid (A), part-solid.
Fig year-old male is shown, who previously was surgically treated for large aortic aneurysm with aorto-iliac graft. A-D. Multiplanar reconstruction.
Fig. 1. (A) Non-contrast CT (calcium score scan) showing no calcification in the right coronary artery (arrow). (B) First-phase contrast-enhanced CT showing.
Fig. 3. A 78-year-old male with chronic total occlusion in the proximal left anterior coronary artery (LAD) and procedure by retrograde wire crossing technique.
Fig. 2. Bland-Altman plots of albumin concentrations from Albumin in Urine/CSF FS (DiASys) testing on a BioMajesty JCA-BM6010/C analyzer. (A) Comparison.
Fig. 1. T2* relaxation time mapping from 55-year-old woman with ductal carcinoma in situ. A. Sagittal contrast-enhanced T1-weighted image shows heterogeneous.
Fig. 5. Receiver operating characteristic curve analyses showing diagnostic accuracy of ADC value for differentiating between bland and malignant PVT.Area.
Zhi-hui Hou et al. JIMG 2012;5:
Investigating the Effects of Motion Streaks on pQCT-Derived Leg Muscle Density and Its Association With Fractures  Adrian C.H. Chan, Jonathan D. Adachi,
Volume 153, Issue 5, Pages (May 2018)
Five algorithms that calculate cardiac output from the arterial waveform: a comparison with Doppler ultrasound  J. Zhang, L.A.H. Critchley, L. Huang 
Fig. 1. HCC in 56-year-old man. A
Transcultural Adaptation and Psychometric Properties of a Spanish-Language Version of Physical Activity Instruments for Patients With Fibromyalgia  Diego.
Comparison of cardiac outputs during major surgery using the Deltex CardioQ oesophageal Doppler monitor and the Novametrix-Respironics NICO: A prospective.
Feasibility of wall stress analysis of abdominal aortic aneurysms using three- dimensional ultrasound  Annette M. Kok, MSc, V. Lai Nguyen, MD, Lambert.
Evaluation of a Wearable Body Monitoring Device During Treadmill Walking and Jogging in Patients With Fibromyalgia Syndrome  Diego Munguía-Izquierdo,
Comparison of haemoglobin measurement methods in the operating theatre
Fig year-old female with meningioma next to falx cerebri. A
Figure 2 Association between coronary artery disease polygenic risk score and the presence of migraine Results are given as odds ratios with 95% confidence.
Bland-Altman plot comparing average steps/day over a 7-day period for the Fitbit tracker and ActiGraph accelerometer. Bland-Altman plot comparing average.
Bland-Altman plots comparing step counts over a 2 min walk test for the Fitbit tracker, ActiGraph accelerometer and visual count by a physiotherapist.
In vivo validation of cardiac spiral computed tomography using retrospective gating  Jörg Albers, MD, Jan M Boese, PhD, Christian F Vahl, MD, Siegfried.
Fig. 2. HCC in 82-year-old man with chronic hepatitis C. A-C
Fig. 5. Contrast-enhanced axial chest virtual monoenergetic dual-energy CT imaging. A. Three round regions of interest are placed in left atrium, back.
Iron and noncontrast magnetic resonance T2
(A) Correlation between SPWV and VPWV, dashed line = line of unity solid line = regression line (B) Bland-Altman plot of agreement between SPWV and VPWV.
François Vermeulen, Marijke Proesmans, Mieke Boon, Kris De Boeck 
Fig. 3. Contrast-enhanced chest volume-rendered CT images with cropped posterior chest wall to unveil cardiovascular structures. A, B. Compared with volume-rendered.
Fig. 8. Indeterminate lymph nodes. A, B
Naoki Watanabe et al. BTS 2017;2:
Fig. 4. Korean Thyroid Imaging Reporting and Data System 3 (low suspicion). None of nodules have any suspicious US features such as microcalcification,
Incremental Shuttle Walking Test: A Reproducible and Valid Test to Evaluate Exercise Tolerance in Adults With Noncystic Fibrosis Bronchiectasis  Anderson.
The accuracy of computed tomography central luminal line measurements in quantifying stent graft migration  Andrew England, MSc, Marta García-Fiñana,
Henri L. Hurkmans, PhD, Johannes B. Bussmann, PhD, Eric Benda, PT 
Virtual noncontrast images yield high diagnostic performance (AUC 0
Catherine M. Capio, MSc, Cindy H. Sit, PhD, Bruce Abernethy, PhD 
Reliability of the Clinical Outcome Variables Scale When Administered Via Telephone to Assess Mobility in People With Spinal Cord Injury  Ruth N. Barker,
Measuring continuity of care: psychometric properties of the Nijmegen Continuity Questionnaire by Annemarie A Uijen, Henk J Schers, François G Schellevis,
Linear Inequalities in Two Variables
P. Persson, O. Stenqvist, S. Lundin  British Journal of Anaesthesia 
Left panel: Correlation between left superficial femoral artery (SFA) transcutaneous partial oxygen pressure (PO2) index (horizontal axis) and the simultaneously.
Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting  Carlos H. Timaran, MD, Eric B.
Pulmonary blood volume measured by contrast enhanced ultrasound: a comparison with transpulmonary thermodilution  I.H.F. Herold, M.A. Soliman Hamad, H.C.
Bivariate plots of mean total scratches and mean total pits for natural grazers. Bivariate plots of mean total scratches and mean total pits for natural.
Bland-Altman plots for intra and inter observer variability for the assessment of total Agatston score for patients with a calcium score less than 1000.
Fig. 5. Korean Thyroid Imaging Reporting and Data System 2 (benign). A
Fig. 3. Korean Thyroid Imaging Reporting and Data System 4 (intermediate suspicion). A. Solid hypoechoic nodule without suspicious US features. Diagnosis:
Fig. 4 Device accuracy results (n = 32 users).
Bland-Altman plots showing intraobserver variability of sTBF measurements for observers 1 (A and C) and 2 (B and D) with maximum (A and B) and average.
Agreement of Mediastinal Lymph Node Size Between Computed Tomography and Endobronchial Ultrasonography: A Study of 617 Patients  Sahajal Dhooria, MD,
Fig. 4. Case with discrepancy between myocardial perfusion imaging and fractional flow reserve. A. 72-year-old woman with stable angina who underwent myocardial.
Bland and Altman plot for comparison of the difference between the score based on the kinematic variables recorded from the photogrammetric system outputs.
Bland-Altman plots of preferred – alternate method versus mean of the preferred and alternate methods for (A) residual volume (RV) for the obstructive.
Fig. 1. TBSS analysis of FA maps
Heat map of microRNA microarray expression from the four groups of patients. Heat map of microRNA microarray expression from the four groups of patients.
Fig. 4. Occludin and ZO-1 decrease in cortex of aged SHRs. A
Fig. 3 Plumage brightness (PC1) for each sex in relation to morphological, ecological, and behavioral traits. Plumage brightness (PC1) for each sex in.
Fig. 2. Korean Thyroid Imaging Reporting and Data System 5 (high suspicion). A. Solid hypoechoic nodule with microcalcifications. B. Solid hypoechoic nodule.
Bland-Altman analyses between cardiac MDCT and echocardiographic measurements of the index of maximum left atrial volume before (A) and after (B) PTSMA.
Bland-Altman plot of arterial and central venous blood Pco2 showing the regression line (solid line) and the 95% limits of agreement of −12.3 to 4.8 mmHg.
Fig. 4. Bland-Altman plots for assessment of agreement of fat-signal fraction (FF) between MR spectroscopy (MRS) and mapping image measurements. Bland-Altman.
(A) Individual participant data points plotting YPAQ-derived MVPA versus accelerometer-derived MVPA. (B) Bland-Altman plot with mean bias and 95% limits.
Presentation transcript:

Fig. 3. Bland-Altman plots of CAC scores between TNC image and MDW (A), MDC (B), MSI (C) images. Mean CAC score from TNC image and VNC images is plotted against difference between two methods. solid blue line = mean difference (bias) between two measurements, dashed green lines = 95% confidence intervals for that difference, dashed red lines = limits of agreement between two measurements. CAC = coronary artery calcium, MDC = material density iodine-calcium pair, MDW = material density iodine-water pair, MSI = material suppressed iodine, TNC = true noncontrast-enhanced, VNC = virtual noncontrast-enhanced Fig. 3. Bland-Altman plots of CAC scores between TNC image and MDW (A), MDC (B), MSI (C) images. Mean CAC score from TNC image and VNC images is plotted against difference between two methods. solid blue line = mean difference (bias) between two measurements, dashed green lines = 95% confidence intervals for that difference, dashed red lines = limits of agreement . . . Korean J Radiol. 2016 May-Jun;17(3):321-329. http://dx.doi.org/10.3348/kjr.2016.17.3.321