Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Schematic of PFBR SGDHR system
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Schematic of the model AHX
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Computational domain for the porous body model
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Flow chart depicting the sequence of calculations in the porous body model
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Numerically predicted mean sodium temperature along the tube length at each pass location at sodium flow rate = 33 kg/s, air flow rate = 31.2 kg/s, and sodium inlet temperature = 494 °C
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Numerically predicted air temperatures along the tube length at each pass location at sodium flow rate = 33 kg/s, air flow rate = 31.2 kg/s, and sodium inlet temperature = 494 °C
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Effect of varying sodium flow rate on the power removed by the AHX at air flow rate = 31.2 kg/s and sodium inlet temperature = 494 °C
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Effect of sodium flow rate on the outlet sodium temperature of the AHX at air flow rate = 31.2 kg/s and sodium inlet temperature = 494 °C
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Effect of varying sodium flow rate on the outlet air temperature of the AHX at air flow rate = 31.2 kg/s and sodium inlet temperature = 494 °C
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Effect of variation of AHX sodium inlet temperature on the outlet sodium temperature at air flow rate = 31.2 kg/s and sodium flow rate = 33 kg/s
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Effect of variation of AHX inlet sodium temperature on the power removed by the AHX at air flow rate = 31.2 kg/s and sodium flow rate = 33 kg/s
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Effect of air flow rate on the AHX outlet air and sodium temperatures at sodium inlet temperature = 494 °C and sodium flow rate = 33 kg/s
Date of download: 11/4/2017 Copyright © ASME. All rights reserved. From: Porous Body Model Based Parametric Study for Sodium to Air Heat Exchanger Used in Fast Reactors J. Thermal Sci. Eng. Appl. 2015;8(1):011010-011010-8. doi:10.1115/1.4030730 Figure Legend: Effect of air flow rate on the power removed by AHX at sodium inlet temperature = 494 °C and sodium flow rate = 33 kg/s