CRYOGENICS – strategy, unavailability root causes and limitations

Slides:



Advertisements
Similar presentations
Status of Cryogenics at point 4 following the power cut L. Tavian 20 August 2011.
Advertisements

Cryogenic system in P4: Possible options S. Claudet & U. Wagner LHC Workshop, “Chamonix XlV” January 2005 (Mostly for RF & beam scrubbing)
Going towards LHC Run2 CRYOGENICS 5 th Evian Workshop 2-4 June 2014 SESSION 4 - Systems 2 - Status and commissioning plans (HW perspective) Krzysztof Brodzinski.
Laurent Tavian Thanks to contribution and helpful discussions with M. Jimenez, V. Parma, F. Bertinelli, J.Ph. Tock, R. van weelderen, S. Claudet, A. Perin,
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
Large-capacity Helium refrigeration : from state-of-the-art towards FCC reference solutions Francois Millet – March 2015.
CRYOGENICS AND POWERING
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
Utilities 14 October 2008 Martin Nordby, Gordon Bowden.
Accelerators for ADS March 2014 CERN Approach for a reliable cryogenic system T. Junquera (ACS) *Work supported by the EU, FP7 MAX contract number.
Workshop Chamonix XIV Shortcuts during installation and commissioning: risk and benefit H. Gruehagen, G. Riddone on behalf of the AT/ACR group 18 January.
Introduction to LHC cryogenic system (layout, architecture) Preparation before cool-down (Purge, flushing) Transient operations to reach nominal operating.
1 Second LHC Splice Review Copper Stabilizer Continuity Measurement possible QC tool for consolidated splices H. Thiesen 28 November 2011 K. Brodzinski,
Cryogenics in SPS & LHC (2 K / 4.5 K) LHC-CC11, 14 November 2011 L. Tavian, CERN, TE-CRG With the contribution of N. Delruelle, G. Ferlin & B. Vullierme.
Cryogenic update before Fermilab meeting (and after the helium tank review) Coordination meeting 6 th May 2015 K. Brodzinski HiLumi-LHC-CC-Cryo-PPT-18_v1.
S. Claudet - 31st May 2007Power refrigeration for LHC Power refrigeration at 4.5K & 1.8K for the LHC S. Claudet, CERN AT-ACR.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
L. Serio COPING WITH TRANSIENTS L. SERIO CERN, Geneva (Switzerland)
Luigi Serio CRYOGENICS PERFORMANCE AND OPERATION L. Serio, on behalf of the LHC Cryogenics Operation and Cryogenics Performance Panel.
TE-CRG-OA Cryo availability for operation and scrubbing.
Cryogenics for crab cavities – SPS/LHC 2 nd HiLumi LHC meeting – Frascati (Italy) 15 November 2012 K. Brodzinski and L. Tavian on behalf of cryogenic team.
Heat loads and cryogenics L.Tavian, D. Delikaris CERN, Cryogenics Group, Technology Department Accelerators & Technology Sector Friday, October 15, 20101HE-LHC'10.
SM18 cryogenics infrastructure upgrade L. Serio TE-CRG.
MAGNET#1MAGNET#2MAGNET#3 SATELLITE VB#1 SATELLITE VB#2 SATELLITE VB#3 PRECOOLER#1PRECOOLER#2 DISTRIBUTION VALVE BOX DVB CP#1CP#3CP#2 BUFFER DEWAR LHe 5m.
D. Delikaris, TE-CRG, LSC 25th Meeting Page 2 October 18 th, 2013 LS1 Committee (LSC)- 25 th Meeting D. Delikaris, TE-CRG Cryogenics activities.
TE-CRG Activities D. Delikaris, TE-CRG.
Crab cavities – cryogenics for SPS and LHC LHC-CC13, 6 th LHC Crab Cavity Workshop – CERN, Geneva, Switzerland 9-11 December 2013 K. Brodzinski on behalf.
LHC CRYOGENICS – new experience of run with increased beam energy and intensity Krzysztof Brodzinski CERN, Geneva, Switzerland With contribution from:
Cryogenics Fault Tree A. Niemi & E. Rogova. Contents 1.Introduction of the current tree structure 2.Failure rates observed in 2015 failure data 3.Unsure.
Project X Workshop - Cryogenics1 Project X CRYOGENICS Arkadiy Klebaner.
5-year operation experience with the 1.8 K refrigeration units of the LHC cryogenic system G. Ferlin, CERN Technology department Presented at CEC 2015.
LHC Cryogenics From cool-down to 1st beams Serge Claudet (LHC Cryo OP), On behalf of cryo teams involved.
Bruno Vullierme Sept LHC-CC09 - 3rd LHC Crab Cavity Workshop Slide 1 CRAB CAVITY INTEGRATION CRYOGENICS INSTALLATION.
FCC Infrastructure & Operation Update on the cryogenics study Laurent Tavian CERN, TE-CRG 28 October 2015.
NIKHEF Annual Meeting, December 18, The LHC Project Status report to the NIKHEF annual meeting Jos Engelen Based on last week’s reports to CERN.
L. Tavian, TE/CRG, LSC Page 2 February 21 th, 2014 LS1 Committee (LSC) L. Tavian TE-CRG.
Crab Cavities SPS cryogenics – progress and requirements Fermilab visit at CERN 02 August 2013 Krzysztof Brodzinski (on behalf of CERN cryogenic team)
FCC Week 2016, Roma Cryogenics overview Laurent Tavian, CERN, ATS-DO On behalf of the FCC cryogenics study collaboration 14 April 2016.
TE-CRG Activities A. Perin, on behalf on the Cryogenics Group.
LHC Performance Workshop LS1 Session Cryogenic system: strategy to achieve nominal performance and reliable operation J. Bremer, K. Brodzinski, J. Casas,
ILC Cryogenics: Study of Emergency Action and Recovery - in progress -
Cryogenics storage and distribution
First operation of the XFEL linac with the 2K cryogenic system
Crab cavities Cryogenics progress for the SPS
M Chorowski, H Correia Rodrigues, D Delikaris, P Duda, C Haberstroh,
IT-4189 Supply and installation of a cryogenic distribution system
Innovative He cycle Francois Millet.
FCC Week 2017, Berlin Towards a conceptual design for FCC cryogenics
Update of cryogenic activities
SPS cryogenic proximity equipment and SM18 validation
S. Claudet, Daniel Berkowitz & A. Perin (TE-CRG)
LHC Performance Workshop (Chamonix 2016)
The LHC - Status Is COLD Is almost fully commissioned
OMP 15th May 2017 Krzysztof Brodzinski and Nicolas Bonetti
Dynamic simulations: a useful tool for cryogenic installations
Preparation of the activities for the LHC Long Shutdown 2
Keeping LHC cold during LS periods Preliminary proposal
Hollow e- lens, Cryogenic aspects
Daniel Berkowitz (TE-CRG)
Activities of the ME section during LS2 ( )
Overview & baseline of LS2 and roadmap for CRG
The HIE—ISOLDE Cryogenic System, its Infrastructure and Considerations for Phase 3 O. Pirotte (TE/CRG)
How does a cryogenic system cope with e-cloud induced heat load
The Fermi National Accelerator Laboratory is a U. S
Mathew C. Wright January 26, 2009
Summary post TCC#54_02Aug’18
Burst Disc Experiences at CEA Test Stand
Cryogenic management of the LHC Run 2 dynamic heat loads
Laurent Delprat CERN, Geneva, Switzerland
HL-LHC New MS optimisation WP9, Preliminary cost estimates
Presentation transcript:

CRYOGENICS – strategy, unavailability root causes and limitations 7th Evian Workshop 13-15 December 2016 Krzysztof Brodzinski on behalf of the cryogenic team With contribution from: S. Claudet, D. Delikaris, L. Delprat, G. Ferlin and E. Rogez

Outlook Introduction – strategy and cryogenic hardware configuration for Run2 Optimization activities on the beginning of 2016 Cryogenics availability – statistics Main unavailability root causes Statistics for main rotating machines Helium consumption Projection in the future EYETS main activities Proposal of operational scenario in 2017 and limitations Conclusions K.Brodzinski_7th Evian_2016.12.13

Introduction – strategy Cooling capacity of A and B are designed to cover nominal LHC operation with equal margins on LL and HL sectors. BUT: w/o dynamic load B has more capacity margin than A -> easier recoveries, B is more powerful for operation because of its design. Thanks to build-in interplant connections some special configurations were possible during Run1 and Run2 for problems mitigation, lower power consumption or optimize for availability and helium losses. Compressor station 4.5 K refrigerator 1.8 K pumping unit (cold compressor) Interconnection box new K.Brodzinski_7th Evian_2016.12.13

Cryo plants Run2 configuration He storage Compression Compression Refrigerator (economizer) Refrigerator (liquefier) A B 1.9 K circuit 1.9 K circuit 4.5 K circuit 4.5 K circuit Magnets supply Magnets supply Currently 1.9 K return flow is unbalanced affecting operational stability and performance of the refrigerators. To resolve the issue 3 valves design must be more precise to control the flow –> to be studied and approved –> modifications foreseen for LS2 (such operation was not foreseen originally) K.Brodzinski_ICEC26_2016.03.10

Global capacity optimization – sector 7-8 The lowest capacity margin was identified in 2015 at P2 (s2-3) and P8 (s7-8) – both cold boxes were optimized with fine tuning in March 2016. ARC EH total power – max. 9300 W Hcell power – max. 175 W Dynamic test P8 QRL line C pressure P7 QRL line C pressure Q6R7 EH power (137 W) Q6L8 EH power (115 W) CM signal 120 A Q6L8 3 losses Q6R7 EH power Q6L8 EH power ARC EH total power – max. 9300 W Hcell power – max. 175 W Dynamic test P8 QRL line C pressure P7 QRL line C pressure Q6R7 EH power Q6L8 EH power Level of cold box phase separator min. 55% CM signal 120 A Q6L8 3 losses ARC EH total power – max. 9300 W Hcell power – max. 175 W Dynamic test K.Brodzinski_LMC_2016.04.06

Global capacity optimization – sector 2-3 ARC EH total power – max. 10300 W Hcell power – max. 195 W P2 QRL line C pressure P3 QRL line C pressure Q6L3 EH power Q6R2 EH power Level of cold box phase separator min. 50% CM signal -/+ 2 kW -/+ 6 kW Q6R2 120 A Q6L3 He level We consider that all LHC cryoplants were aligned for BS heat load compensation in 2016 at level of 160 W/hc 120 A Q6L8 3 losses K.Brodzinski_LMC_2016.04.06

Availability – Cryo Maintain statistics Statistics for Run2 (2016) period from 25th March to 5th December 2016 K.Brodzinski_7th Evian_2016.12.13

Cryo Maintain statistics Time affected 2015 Total down time = 273 h 29 min Number of events 164 losses 19 losses 2016 Total down time = 79 h 25 min Main improvements (2016 vs 2015) come from: good feed-forward tuning for BS control, P2 and P8 cold boxes operational optimization for capacity, P8 cold box repairs (temporary with varnish applied on AL/SS transition, the transition will be replaced during EYETS), DFB level adjustment. Complementary remarks: More than 60% of time losses are related to two top contributors (PLC and cryo production plants). New PLC anti-crash firmware upgraded last YETS 2015/16 did not resolve the failure problems… New upgrade with PLC Schneider type 580 is planned to start in EYETS – more info from BE-ICS. K.Brodzinski_7th Evian_2016.12.13

4.5 K refrigerators – cryo causes RUN 1 RUN 2 3.5 TeV to 4 TeV 6.5 TeV 1x human factor, 2x PLCs 0.83 0.81 Failure rate 0.67 0.39 0.32 K.Brodzinski_7th Evian_2016.12.13

1.8 K pumping units – cryo causes RUN 1 RUN 2 6.5 TeV 3.5 TeV to 4 TeV 1x AMB CC, 1x mechanical failure WCS 2 1.8 Failure rate 1.6 1.5 0.5 K.Brodzinski_7th Evian_2016.12.13

Helium consumption and losses Run 1 Run 2 Progressive reduction of operational losses was obtained thanks to regular leak search. Increase of losses during technical stops/YETS – transients, purges, leak investigation and incidents. K.Brodzinski_7th Evian_2016.12.13

Beam screen – heat load in 2016 General limit including transfer of capacity dedicated to 1.9 K loop 116 Installed capacity Design capacity 85 *The graph shows raw value of the heat load seen by cryogenics. K.Brodzinski_7th Evian_2016.12.13

EYETS main activities Preparation and conditioning: P18 s1-2 – to be completely warmed up for 31L2 dipole replacement All other sectors* – to be emptied from LHe and conditioned with GHe at ~30 K *S3-4 and 4-5 – training quench by 15th December then empting Main repairs and consolidations: P8 QSRB cold box leak repairs – AL/SS transition to be replaced P4 and P6 QSCAs: installation of additional oil filtering coalescers PLCs: upgrade to new Schneider type 580 on 50 % of equipment (by EN-ICS) Replacement of active charcoal in 14 adsorbers – standard activity Installation of first prototypes of RFL valves (high failure rate – TUs availability) Updates of software and multiple other maintenance and repairs activities K.Brodzinski_7th Evian_2016.12.13

Warm up curve of sector 1–2 s1-2 warm up is progressing well as foreseen in the planning TT max TT avg TT min K.Brodzinski_7th Evian_2016.12.13

Run2 (2017) scenario and limitations For 2017 run we plan to apply the same configuration as in 2016 Generated heat load with dynamics as during 2016 can be fully compensated by the cryogenic system. However the below comments are to be considered: The limit to compensate for thermal load on BS circuit is 160 W/hc. During 2016 ITs 1.9 K cold mass suffered from not optimized dynamics of the cryogenics during collisions  special feed forward logic was developed, tested and applied for 2017 operation – no problems expected if heat load below 250 W/IT. Scaling exercise: (~200 W/IT during run of 2016 at 6.5 TeV and Lpeak =1.5e34  Lpeak could raise max to 1.75e34 to produce ~250 W/IT – value confirmed by test during TS2 K.Brodzinski_7th Evian_2016.12.13

Conclusions Thank you for your attention! Questions ? Cryogenic Run2 (2016) was a success with CM availability at 98.6 % (94.4 % including utilities and users losses affecting cryogenics). New configuration was applied and validated for P18/P2 cryo plants. Feed forward logic and main cold boxes optimization at P2 and P8 leaded to smooth operation of BS loops, however e-cloud thermal effect stayed above design values (average 1.5*design values for 4 sectors). Run2 (2017): referring to lesson learned in 2015 and 2016, cryogenics guaranties at least the same level of capacity as delivered until now. Correct dealing with any higher heat load is possible up to 160 W/hc for BS and 240 W/IT (max Lpeak =1.75e34 s-1 *cm-2). Injection of trains with 288 bunches will be next challenge which will require tuning of dynamic response of the cryogenics during injection and ramp. Thank you for your attention! Questions ? K.Brodzinski_7th Evian_2016.12.13

Back up – P4 specificity A B Upper cold box Upper cold box compressors compressors 30 K  low ρ*g*h 4.5 K  low ρ*g*h (it is heavy) Lower cold box 30 K 30 K RF at 4.5 K and 1.35 bara RF at 4.5 K and 1.45 bara It is better to boost plant A but it results in high pressure in cavity on side B. With boost of plant B all cavities can run at the same pressure but special equilibrium of capacities by thermal screen circuit must be put in place to mitigate unbalance between two cryoplants A and B (only possible in Linde plants – at P4 and P6)  recommended scenario for P4, no strong preference for P6. K.Brodzinski_7th Evian_2016.12.13