Image quality and Performance Characteristics

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Instruments for Radiation Detection and Measurement Lab # 4.
NUCP 2371 Radiation Measurements II
Formation Characteristics
IMAGE QUALITY.
Chapter 8 Planar Scintigaraphy
Basic Principles of X-ray Source Detection Or Who Stole All Our Photons?.....
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
1. 2  Ray Imaging u Inject a pharmaceutical labelled with a radioactive nuclide  Detect where  -rays are coming from u Local concentration in patient.
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Imaging Part 3.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods
Gamma Camera Technology
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Quality Control.
Image Quality Radiographic Resolution.
Fundamental Limits of Positron Emission Tomography
M. Alnafea1*, K. Wells1, N.M. Spyrou1 & M. Guy2
Chapter 3: Image Restoration Introduction. Image restoration methods are used to improve the appearance of an image by applying a restoration process.
Factors affecting CT image RAD
Digital Imaging. Digital image - definition Image = “a two-dimensional function, f(x,y), where x and y are spatial coordinates, and the amplitude of f.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter.
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
Nuclear Medicine Principles & Technology_I
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
X-ray SNR in 3 steps. I ∆I. X-ray transmission SNR Review Let N = average number of transmitted x-rays N = N 0 exp [ - ∫  dz ] Emission and transmission.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
CAT scanners and gamma cameras Unit 16 Waves. Learning objectives Describe how CAT scanners can produce a much more detailed image than conventional X-rays.
The requirements of Ideal pulse-type counter :  1 Every particle entering the detector should produce a pulse at the exit of the counter,
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Physics & Instrumentation I
Chapter-4 Single-Photon emission computed tomography (SPECT)
Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types.
Nuclear Medicine Introduction
PET Imaging Positron Emission Tomography
Chapter-5 Positron emission tomography (PET)
Gamma Camera Technology
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Spatial Resolution and minimum detection
Nuclear Medicine Physics
Chapters 21 & 22.
Impact of Obesity on Medical Imaging and Image-Guided Intervention
FINAL YEAR PROJECT 4SSCZ
Image quality and Performance Characteristics
Rad Tech 265.
NANO 230 Micro/NanoFabrication
Unit V: Introduction to Gamma Camera
Lecture 1: Development of the Analog Gamma Camera
Chapter 8: Generic performance measures
Application of Nuclear Physics
Pulse Processing Chapter No. 17
CLRS 321 Nuclear Medicine Physics & Instrumentation I
Nuclear Medicine Physics & Instrumentation I
Gamma-Gamma Correlations in Na-22
General Properties of Radiation
General Properties of Radiation
Nuclear Medicine Physics & Instrumentation I
Chapter No. 10 General description of electronic units used in radiation measurements. viewpoint of ‘ input-output'-i.e., the input and output signals.
Resident Physics Lectures
Function and Structure in
Gamma Camera Ilker Ozsahin Oct
Product moment correlation
Assist. Prof. Dr. Ilker Ozsahin Oct
I  Linear and Logical Pulse II  Instruments Standard Ch 17 GK I  Linear and Logical Pulse II  Instruments Standard III  Application.
Presentation transcript:

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Basic Methods for characterizing and evaluating image quality The first by means of physical characteristics that can be quantitatively measured or calculated for the image and image system Spatial resolution Contrast Noise Contrast-to-noise ratio (CNR) The second by means of observer performance studies using images obtained with different imaging systems or under different imaging conditions

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Image contrast refers to differences in intensity in parts of the image corresponding to different levels of radioactive uptake in the patient. A general definition of contrast is that it is the ratio of signal change of an object of interest, such as lesion, relative to the signal level in surrounding parts of the image.

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast In nuclear medicine, a major component of image contrast is determined by the properties of the radiopharmaceutical. It is desirable to use an agent having the highest lesion-to-background uptake or concentration ratio. The major factor affects contrast is added background counting rates that are superimposed more or less uniformly over the activity distribution of interest.

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Background counting rates can arise from a number of sources: Septal penetration is avoided by using a collimator that is appropriately designed for the radionuclide of interest Inadequately shielded radiation sources elsewhere in the image environment Scattered radiation  scattered radiation can be minimized by pulse-height analysis, however, the system cannot reject all scatter ??

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Background counting rates can arise from a number of sources:

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Background counting rates can arise from a number of sources:

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Background counting rates can arise from a number of sources:

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Background counting rates can arise from a number of sources: Talk about the FWHM

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Background counting rates can arise from a number of sources: An important contributor to background radiation in conventional planar imaging is radioactivity above and below the object of interest image contrast improved in SPECT because it permits imaging of an activities in overlying and underlying structures. Tomographic techniques offer significant improvements for the detection of low-contrast lesions.

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 2. Contrast Background counting rates can arise from a number of sources:

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Basic Methods for characterizing and evaluating image quality The first by means of physical characteristics that can be quantitatively measured or calculated for the image and image system Spatial resolution Contrast Noise Contrast-to-noise ratio (CNR) The second by means of observer performance studies using images obtained with different imaging systems or under different imaging conditions

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 3. Noise Random noise (Statistical noise, Quantum mottle) Structured noise

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 3. Noise Ransom noise, statistical noise or quantum mottle It refers to the mottled appearance of nuclear medicine images caused by random statistical variations in counting rate. It is very important factor in NM imaging and present everywhere in NM image. Even when the size of an object is larger than the limiting spatial resolution of the image, statistical noise can impair detectability, especially if the object has low contrast. Talk about the FWHM

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 3. Noise Random noise (Statistical noise, Quantum mottle) Structured noise

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 3. Noise Structured noise It refers to nonrandom variations in counting rate that are superimposed on and interfere with perception of the object structures of interest. Some types of structured noise arise from the radionuclide distribution itself. For example, in planar imaging, uptake in the ribs may be superimposed over the image of the heart. Structured noise also can arise from imaging system artifacts (nonuniformities) Talk about the FWHM

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Basic Methods for characterizing and evaluating image quality The first by means of physical characteristics that can be quantitatively measured or calculated for the image and image system Spatial resolution Contrast Noise Contrast-to-noise ratio (CNR) The second by means of observer performance studies using images obtained with different imaging systems or under different imaging conditions

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 4. Contrast-to-noise ratio (CNR) The critical parameter for detectability is the CNR of the object in the image. To detect a lesion or other object in an image, the observer must be able to distinguish between the lesion or object and noise-generated contrast patterns in background areas of the same size in the image. The ratio of lesion-contrast to noise-contrast is the CNR

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using physical characteristics 4. Contrast-to-noise ratio (CNR) A substantial amount of research has been conducted to find the best way to calculate the CNR. One of the idea is that, in order to be detectable, an object’s CNR must exceed 3-5. this factor is known as the Rose criterion, after the individual who did basic studies on this subject. However, the actual value depends on object shape, edge sharpness, viewing distance, observer experience, ……..etc

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Basic Methods for characterizing and evaluating image quality The first by means of physical characteristics that can be quantitatively measured or calculated for the image and image system Spatial resolution Contrast Noise Contrast-to-noise ratio (CNR) The second by means of observer performance studies using images obtained with different imaging systems or under different imaging conditions Discussion group

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Evaluating image quality using observer performance studies Example (Receiver operating characteristic (ROC))

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics Important points in chapter 3 (chapter 14 and 15 from the book) Part-1 Part-2 Gamma camera performance characteristics Image quality of gamma camera

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Spatial resolution Detection efficiency Energy resolution Performance at high counting rate

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Detection efficiency The trade-off in gamma cameras is between detection efficiency (which improves with thicker crystals) and resolution (which improve with thinner crystals). The gamma camera is designed to provide acceptable detection efficiency while maintaining high resolution in the range of a certain energy range (100-200 KeV).

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Detection efficiency

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Detection efficiency

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Energy resolution Because the Compton-scattered photons have lower energy, it is possible to discriminate against them using the pulse-height analysis. The energy resolution of the detector determines the efficiency with which this can be accomplished. Energy resolution depends largely on statistical fluctuations in the number of light photons collected from a scintillation event  thus, a good light collection efficiency is a prerequisite for good energy resolution.

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Performance at high counting rate At high counting rates, there is increased likelihood of recording two events at the same time. This effect is known as the pulse pile-up. Pulse pile-up has two undesirable effects on gamma camera performance Counting losses Image distortion

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Performance at high counting rate Counting losses Counting losses cause inaccurate counting rates to be recorded at higher counting rates, because of the dead time. The dead time is the time that the gamma camera stop processing the second detected count while its busy processing the first one. Dead time losses are not serious in most static imaging studies, but they can be important in certain high-counting-rate applications. Dead time corrections can be applied.

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Performance at high counting rate Counting losses One approach for shortening camera dead time is by the use of a certain electronic circuits that hold a pulse from one circuit component until the next circuit in the pulse-processing sequence is ready to receive it. Another approach, is by slow down the rate at which the camera can handle individual event.

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Performance at high counting rate At high counting rates, there is increased likelihood of recording two events at the same time. This effect is known as the pulse pile-up. Pulse pile-up has two undesirable effects on gamma camera performance Counting losses Image distortion

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Performance at high counting rate Image distortion

Image quality and Performance Characteristics Chapter-3 The Gamma Camera Image quality and Performance Characteristics The gamma camera : Performance characteristics The major factors that determine gamma camera performance Performance at high counting rate Image distortion