Standards Changes that will Affect Signal Receiving Centres in Canada

Slides:



Advertisements
Similar presentations
D-Link Assist Introduction Neil Patel October 2010.
Advertisements

OVERVIEW TEAM5 SOFTWARE The TEAM5 software manages personnel and test data for personal ESD grounding devices. Test and personnel data may be viewed/reported.
Tel: Unique Home Security Systems Security Supplies Captures Boards Digital Video Recorders Power Line Communication Wireless Solutions.
May 2012 Dave Mertz, Deputy Fire Marshal Hanford Fire Department.
Compliance on Demand. Introduction ComplianceKeeper is a web-based Licensing and Learning Management System (LLMS), that allows users to manage all Company,
Alarming The Insurance Company The perspective from the Risk Insurance Industry; The most common problems we see, and recommendations to overcome them.
© 2001 National Burglar & Fire Alarm Association Chapter 10 The Central Station –24 hour /7day Operation –Receive Signals –Process Signals –React.
1 INTRUSION ALARM TECHNOLOGY LOCAL VS. MONITORING.
FIRE ALARM SYSTEMS AND FUNDAMENTALS
Network security policy: best practices
Chapter 14: Inspection and Maintenance
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N 1 Network Operating Committee (NOC) June 12 th, 2014.
ENP Study Group Disaster Planning Session #6 BROUGHT TO YOU BY: THE FLORIDA NENA EDUCATION COMMITTEE.
Source One Network Solutions with Corporate Headquarters based in Fitchburg, Wisconsin specializes in providing multi- location clients, with nationwide.
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
Company Profile ► Our Expertise Here at SIEMSTECH we have a passion for designing and implementing integrated, network-centric technology solutions across.
Current Job Components Information Technology Department Network Systems Administration Telecommunications Database Design and Administration.
Corporate Information Systems Delivery of Infrastructure IT Services.
© 2006 Avaya Inc. All rights reserved. Avaya Services Michael Dundon Business Development Manager.
This presentation is part of a larger program that includes hand outs with checks lists and user instruction tips. If you do not have these materials they.
1. There are different assistant software tools and methods that help in managing the network in different things such as: 1. Special management programs.
© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Confidential. For Channel Partners only. Do not distribute. C
Scott Butson District Technology Manager. Provide professional to all district staff Professional development has been provided on a regular basis to.
© 2010 Oracle Corporation – Proprietary and Confidential.
Firefighter III Module C Communications (4-4) Identify the policy and procedures concerning the ordering and transmitting of multiple alarms.
Chapter2 Networking Fundamentals
Grid Operations Centre LCG SLAs and Site Audits Trevor Daniels, John Gordon GDB 8 Mar 2004.
Fire Alarm Verification CAN/ULC-S561-03
Physical Security at Data Center: A survey. Objective of the Survey  1. To identify the current physical security in data centre.  2.To analyse the.
SAP MDG (Master Data Governance) online training Online | classroom| Corporate Training | certifications | placements| support CONTACT US: MAGNIFIC TRAINING.
Engineered Security Systems, Inc. Access Control Systems CCTV Systems Asset Protection Systems Fire Alarm Systems Laptop Protection Systems Burglar Alarm.
MyLoneWorkers A Lone Worker system.
WIRELESS FIRE DETECTION
Safeguarding CDI - compliance with DFARS
ClubRunner and Rotary International Database Integration
Carbon Monoxide Detection: Code and Legislation Updates
Chapter 7. Identifying Assets and Activities to Be Protected
Chapter 19: Network Management
ICON Signals Event Alert Notification Platform Overview March 28, 2017
NERC Published Lessons Learned Summary
An Introduction to Attendance on Demand
1+1 Ethernet Failover & Network Protection Switches
FIRE ALARM TRANSMISSION METHODS “NFPA ”
Managing the Delivery of Information Services
NICET Fire Alarm Tech Level 1 Practice Test
DS3 Fail-over Protection Switch
Control system network security issues and recommendations
The Company Initial Orientation Training for:
NERC CIP Implementation – Lessons Learned and Path Forward
CORPORATE PROFILE JUNE 2016
Audit Plan Michelangelo Collura, Folake Stella Alabede, Felice Walden, Matthew Zimmerman.
A Better Choice For COMPANY NAME
Need for VPN As a business grows, it might expand to multiple shops or offices across the country and around the world. the people working in those locations.
AIM Armstrong’s Intelligent Monitoring Training presentation.
Wavestore Integrates… Paxton Net2 Access Control
The E-Rate Program Eligible Services Fall 2011 Applicant Trainings.
Wavestore Integrates…
Business Continuity Planning
Theresa (Tess) Espejo Project Manager, ULC Standards September 7, 2018
AGA Distribution Best Practices Program Control Room Management
What is the UL QFCP? FCIA Webinar Presenters:
Project Information Management Jiwei Ma
REMOTE POWER MONITORING OF MARINE SITES
ClubRunner and Rotary International Database Integration
Data Centre Environment
VIDEO REMOTE INTERPRETING
Bella Vista Fire Department Procedures on Sprinkled Buildings
Project Certification Planning Phase August 27, 2014
Presentation transcript:

Standards Changes that will Affect Signal Receiving Centres in Canada Alan Cavers Engineering Manager Underwriters Laboratories of Canada October 17, 2017

Agenda ULC Standards under review CAN/ULC-S301 Changes Redundant Site requirement Hosted Central Station Managed Video Services CAN/ULC-S561 Managed Facilities Voice Networks Web Certificates and Alarm Hub ULC Standards

Standards Affecting Signal Receiving Centres- Under Review CAN/ULC-S301 – STANDARD FOR SIGNAL RECEIVING CENTRES CONFIGURATIONS and OPERATIONS (NEW) - New Edition to be released early to mid 2018 CAN/ULC-S561 - STANDARD FOR INSTALLATION AND SERVICES FOR FIRE SIGNAL RECEIVING CENTRES AND SYSTEMS (NEW) - New Edition to be released early to mid 2018 Important : Harmonization of the Construction Sections  

CAN/ULC- S301 – New Edition Key points to note: Proposed Harmonization with S561 on the Construction Relaxation on the Fire Separation Expanded Section on Station Automation - Remote Access Requirements Hosted Central Station Managed Video Services Redundant Site Requirement

Fire Separation Requirements Present Requirement: Required 2 hour fire separation for the Signal Receiving Centre. Relaxation of this requirement: 1 hour fire separation in a fully sprinklered building.

Remote Access Requirements Allow remote access at different levels under controlled conditions such as: No access to alarm operation or handling of signal from intrusion systems outside operations area. Will allow data entry outside operations area. Will allow dealers to create and configure new accounts. Allow Technicians to put systems on/off tests remotely and view history. No remote arming and disarming of alarm panels outside operations area.

CAN/ULC-S301 – Redundant Site Requirement A physical location that is able to provide all of the essential functions of a signal receiving centre should an automated signal receiving centre become unable to process signals. Requirement: A minimum of two Signal Receiving Centres shall be provided in compliance with the applicable requirements of the Standard. Proposed Timeframe: 5 years from the published date of this Edition

Redundant Site Requirement – How to Achieve? Signal Receiving Centre builds a new site. Utilize a different Signal Receiving Centre as a fail over point. Utilize the services of Alarm Monitoring Software provider. Hosted Central Station

Hosted Central Station Services Central Station Automation as a Service + = to a business and its public customers

Hosted Central Station Services- Canada Canada will use CAN/ULC-S301 as the base document with additional requirements for Redundancy. Note: In Canada these facilities are known as Signal Receiving Centres. Provides guidance and clarification of responsibilities for Hosting partner and the public facing Signal Receiving operating company Hosting provider held to same basic requirements as a Signal receiving Centre. If independent data centers used for hardware & infrastructure, ULC audits the data centers on same frequency as any Signal receiving Centre. Certification of a Hosted provider allows ULC to work directly with the Host and eliminate relevant issues from audits of the public facing Signal Receiving operating company.

Hosted Central Station Services CAN/ULC-S301 - Proposed Proposition Automation System Servers & database maintained in redundant data centers Signal Receiving Centre operators log into service via VPN Customers can only access there own information Automation Software shall be capable of separating end users. Customers/alarm service subscribers experience no difference in service Benefits: Signal Receiving Centre don’t need to: Invest and keep reinvesting in IT hardware Patch operating systems & automation system software Maintain IT technical expertise on above Administer cyber-security details on automation systems

Managed Video Services MANAGED VIDEO SIGNAL RECEIVING CENTRE (MVSRC) - The portion, or portions of a building, occupied by a video monitoring service company that encompasses the Centre Operations Area and the facilities essential to the operation of monitoring, processing, and disposition video signals. (Managed Video Signal Receiving Centre may be used interchangeably with Signal Receiving Centre, SRC)

Managed Video Services A Managed Video Services monitoring station receives, assesses, acts upon, and retains video images received from protected properties as defined in an agreement between the company operating the monitoring station and subscribers of the monitoring services. Early times for the technology & service Technology allows huge variety of services Categorization of extents of protection or grades of service very difficult Industry suggested 3 general “types” Triggered Events – site activation Scheduled Events- Specific time viewing Live View Service- medium to long term monitoring. Other Services – As per CAN/ULC-S316 – CCTV Standard Certificate Allow for maximum flexibility Characterize the “type(s)” of service Refer to subscriber agreement for details UL/ULC audit staff confirm/verify service delivered per service agreement

CAN/ULC- S561 – New Edition Key points to note: Proposed Harmonization with S561 on the Construction Relaxation on the Fire Separation – Same as S301 Expanded Section on Station Automation – Same as S301 Remote Access Requirements- Same as S301 Hosted Central Station- Same As S301 Redundant Site Requirement – Same as S301

Fire Monitoring in Canada Why is this important for Alarm Companies to know about Signals to the Fire Department? If it is not ULC Certified why do I have to follow the rules? Do I have to issue a ULC Certificate on all Fire Monitoring Installations? Are there two sets of rules for fire monitoring?

Standard System in Canada for Fire Alarm System- Example National Building Code- defines who needs a fire alarm system and/or a fire monitoring system. National Building Code – gives reference to the installation of the fire alarm system – CAN/ULC-S524 and the Signals to the Fire Department- CAN/ULC-S561. Required for Occupancy National Building Code – gives reference on how the fire alarm system is to be Verified prior to occupancy. CAN/ULC-S537 and CAN/ULC-S561 National Fire Code- gives reference to the ongoing maintenance of the fire alarm system –CAN/ULC-S536 and maintaining the Fire Monitoring the protected building- CAN/ULC-S561.

Single Stage Fire Alarm System Where does it state that fire monitoring Systems shall comply? NBC 3.2.4.8 Single Stage Fire Alarm System 300 person occupancy FAS with water-flow switches In Ontario – High Buildings & Vulnerable Occupancies Two Stage Fire Alarm System First Stage- Alert has been initiated

Code References NBC 3.2.4.5 (1) CAN/ULC-S524-06 NBC 3.2.4.5.(2) CAN/ULC-S537-04 NBC 3.2.4.8 (4) CAN/ULC-S561- 03 & 13 NFC 6.3.1.2. (1) CAN/ULC-S536-04 NFC 6.3.1.3 CAN/ULC-S561-03 & 13

What Are Some Things You Need to Know? No Fire Alarm Verification Signals need to be transmitted to the Fire Signal Receiving Centre (FSRC) within 60 seconds. FSRC shall contact the fire department in 30 seconds. Trouble and Supervisory Signals – Contact customer within 5 minutes. Communication Troubles- Contact Customer within 5 Minutes.

Exceptions. Trouble signals from the fire alarm panel. Contact customer in 5 min Exception: Large power outage affecting more than one property. - Delay notification for up to 12hrs pending receipt of restoral. - If no restoral signal received within 12 hrs. – Contact Customer

Exceptions Communication troubles – Contact Customer 5 min. Exception- Delay up to 60 minutes if Dual Communication Channels are utilized.

Exceptions Trouble Signals from Signal transmitting Units - Contact customer within 5 min. - Dispatch personnel to arrive within 4 hours. Exception- In isolated areas in access of the 4 hour service response time, permitted to exceed this time , Acceptance by the AHJ.

Certification Bulletin 2017-02A Managed Facilities Voice Networks - MFVN MFVN Definition: Managed Facilities-Based Voice Network (MFVN). A physical facilities-based network capable of transmitting real time signals with formats unchanged that is managed, operated, and maintained by the service provider to ensure service quality and reliability from the subscriber location to public switched telephone network (PSTN) interconnection points or other MFVN peer networks. PSTN Definition: Public Switched Telephone Network (PSTN). An assembly of communications equipment and telephone service providers that utilize managed facilities-based voice networks (MFVN) to provide the general public with the ability to establish communications channels via discrete dialing codes.

What does this mean for Signal Receiving Centres? Introduction of Digital Phone Service for Fire monitoring. MFVN Companies no longer provide 24 hr standby power on phone services from the central offices. Now reduced to 8 hours on average. NFPA 72 – dealt with this 3 years ago requiring an increased frequency of testing the phone line connecting to every 6 hours instead of every 24 hours. ULC Certificate Services adopted the same frequency on passive communication systems.

What does this mean under the ULC Certificate Program for fire monitoring systems? Bulletin Dated Sept. 20, 2017 New Systems must comply. Existing systems will need to comply in the future. - Annual audit finding will be giving an Observation - 1 year to comply to increase frequency.

Introduction of New Web Certificates & Alarm Hub

Web Certificates Re-launch Web Certificates will relaunch a new web certificates portal Feb. 2018. Alarm Hub - Link www.ul.com/alarmhubinfo Canada to pilot first in North America. Enhance features for a better user experience. - Ease of use for all alarm companies - Better Reporting for all companies – SRC and dealers - AHJ Portal for all certificates issued in jurisdictions - End user Portal for Insurers and Police Departments - Instant notifications – new and canceled certificates

Web Certificates Relaunch Continued Future features – Later 2018 Access to invoices Access to annual audit reports. Ability to close out audit findings through the portal. And more to come as users identify other opportunities for it functionality.

Web Certificates & Alarm Hub Drop by the ULC Booth for further information on the new design.

ULC Standards Consensus Based Cross section of industry must make up the Standards Committee Who is involved in writing these Standards? Manufacturers, Alarm Companies, End Users, Insurers/AHJ’s Can I get involved? YES , Contact ULC Standards if you want to comment on a Standard or be on a committee.

How can you get involved? Commenting on Standards Request from ULC Standards access to these standards for review and comment- Access granted through the portal (CSDS) Automated notification when to comment Request reply for your comments New Standards- Always looking for help

What can happen if the rules are not followed.

Contact Information THANK YOU Contact Information Alan Cavers, Engineering Manager, Phone- 1-416-697-6762 E-mail alan.n.cavers@ul.com

THANK YOU.