Quality of CT Images Acquired with Power Injection of an Arm Port

Slides:



Advertisements
Similar presentations
Medical Interventions Mrs. Stewart Central Magnet School
Advertisements

Improved Conspicuity of Abdominal Lesions with Single-Source Dual-Energy MDCT Hadassah Hebrew University Medical Center Jerusalem, Israel Ruth Eliahou.
CARDIOVASCULAR IMAGING WITH COMPUTED TOMOGRAPHY(CT)
Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning.
Dr. Anas Alasolaiman Radiology department
Consent for Research Study A study for patients with a diagnosis of liver cancer who are on the waiting list for a liver transplant Comparison of advanced.
Radiation Dose in MS-CT coronarography Ladislav Pavic, MD, PhD Sunce Clinics Zagreb / Sarajevo Croatia / Bosnia & Herzegovina.
Meta Imaging Solutions Patient centered innovations Introduces:
EVALUATION OF ACUTE PULMONARY EMBOLISM USING SPIRAL CT SCAN 1 Sudan University of Science and Technology, College of Medical Radiologic Science, P.O.Box.
The Heart. Description of the Heart Location:  Between the lungs  More to the left of your chest Size of the Heart:  12cm in length  8-9cm in width.
Revision Dr Mohamed El Safwany, MD.. Liver CT Blood circulation in the liver comprises two major components: the hepatic artery and the portal vein. After.
MedPix Medical Image Database COW - Case of the Week Case Contributor: Fred R Brandon Affiliation: National Capital Consortium.
JUSTIFICATION OF COMPUTERIZED TOMOGRAPHY EXAMINATIONS AND RADIATION RISKS IN EVERYDAY RADIOLOGICAL PRACTICE Darka R. Hadnađev, Olivera Nikolić, Sanja Stojanović.
The Application of Multi-detector Computed Tomography in RVOT Ablation in BRUGADA’ s Syndrome Paweena Mapinta R.T, Cardiac Imaging Unit, Bangkok Heart.
Intended learning outcome The student should learn at the end of this lecture procedures of CT pulmonary angiography.
Department of Radiology
MEASUREMENTS OF RADIATION DOSES IN MULTISLICES COMPUTED TOMOGRAPHY EXAMINATIONS A. ELMAHDI*, A. SULIEMAN *Presenting author 1 Sudan Atomic Energy Commission,
Wednesday Case of the Day History: CT pulmonary angiography (image shown) was performed on a 24-year-old female patient with pleuritic chest pain and increased.
Radiology Course CT scan
CT Image Quality for CT Pulmonary Embolism (CT PE) and Chest CT Aorta Acquired with Power Injection via an Arm Port Ryan Verity 1, David Leswick.
Date of download: 6/24/2016 From: The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC): Results From a Multispecialty Panel Using the RAND/UCLA.
Prevalence and clinical risk factors for interstitial lung disease in rheumatoid arthritis in a resource limited setting A Dasgupta, P Bhattacharyya, S.
M.H. Nezafati Associate Professor of Cardiac Surgery
School of Nursing, Midwifery and Social Work Malnutrition or poor body composition, particularly sarcopenia, may have a negative impact on clinical outcome.
Background Trauma Patients undergo an initial, “on admission” CT scan which includes: Non contrast brain Arterial phase full body scan Portal venous phase.
Organ dose and effective dose in Full spine Eaxamniations by EOS® Stereo-radiography with micro-dose settings. A study on anthropomorphic phantoms describing.
Dr. Malhar Patel DNB (Radiation Oncology)
The Efficacy and Safety of the Low Intensity Ultrasound Treatment in Patients with Open Angle Glaucoma Hyoung Won Bae, Gong Je Seong, Chan Yun Kim Institute.
Diagnostic Imaging Medical Interventions
the proximal femoral fracture patients
Bard PowerPICC Solo2 vs. Cook Turbo-Ject: A Tale of Two PICCS
Figure 1. Onset of PIV catheter complications
Complications of Central Line Insertion
Diabetes and Hypertension Health Screening in the Fresno Sikh Population: A Cross Sectional Approach Baljit Singh Dhesi 1,2 1University of California,
Journal of Nuclear Cardiology | Official Journal of the American Society of Nuclear Cardiology Consistent tracer administration profile improves test-retest.
Role of Adaptive Statistical Iterative Reconstruction (ASIR) in lowering radiation dose for pediatric head CT Electronic Poster-eP 140 Azadeh Tabari, MD.
Sunday Case of the Day Physics
Fluoroscopy of the Arm During Removal of the Cook Vital Port
นายแพทย์ธราธร ตุงคะสมิต นายแพทย์ชำนาญการพิเศษ โรงพยาบาลมะเร็งอุดรธานี
Reducing radiation dose and enhancing imaging quality of 4DCT for radiation therapy using iterative reconstruction algorithms  George Noid, PhD, An Tai,
Siân Cleaver1, Dr Nikki Pease2, Hilary Thomas2, Dr Audrey Yong2
Standard Report Terms for Chest Computed Tomography Reports of Anterior Mediastinal Masses Suspicious for Thymoma  Edith M. Marom, MD, Melissa L. Rosado-de-Christenson,
Gateways to the heart – Incidental CT findings of anomalous systemic venous connections and the clinical challenges they present Hanzhou Li, Christopher.
TECHNOLOGY UPDATE TIVUS (Cardiosonic)
CT-based surrogates of pulmonary ventilation in lung cancer:
Hayley Milne & Andrew England
PHQ2 Screening Negative PHQ2 Screening Positive
The “Broken Ring” Sign in Magnetic Resonance Imaging of Partial Anomalous Pulmonary Venous Connection to the Superior Vena Cava  PAUL R. JULSRUD, M.D.,
Exhibit Number: C19 Evaluation and Reduction of Head Computed Tomography Dose Because of full frame graphic use title slide sparingly because too many.
Strategies for Reducing Radiation Exposure From Multidetector Computed Tomography in the Acute Care Setting  Aaron Sodickson, MD, PhD  Canadian Association.
PA Court Ruling on Consent
F. Gibson, A. Bodenham  British Journal of Anaesthesia 
Pediatric Central Venous Catheters In Patients Less Than Two Years Of Age: Do Complication Rates Differ Between Tunneled IJ, Tunneled Femoral, and PICCs?
ERIK L. RITMAN, M.D., Ph.D.  Mayo Clinic Proceedings 
Wednesday Case of the Day
Sectional Anatomy Neck Vasculature.
Sectional Anatomy Chest Vasculature.
Sectional Anatomy Abdomen/Pelvis Vasculature.
Fig. 5. A 75-year-old woman with severe aortic stenosis and aortic dissection managed by aortic valve replacement and ascending aorta and hemiarch replacement.
Dynamic computed tomography to determine cardiac output in patients with left ventricular assist devices  Subha V. Raman, MD, MSEE, Tam Tran, BS, Orlando.
The effect of vertical centering and scout direction on automatic tube voltage selection in chest CT: a preliminary phantom study on two different CT.
Ethical Considerations for Pediatric Clinical Investigations
The use of 80 kV versus 100 kV in pulmonary CT angiography: An evaluation of the impact on radiation dose and image quality on two CT scanners  A. Rusandu,
Fundamental Nursing Chapter 16 Fluid and Chemical Balance
Test tool for assessing lead equivalence in protective lead apparels
INTRODUCTION TO RADIOLOGY IMAGING MODALITIES Asilah Al-Obeidani.
Axial contrast-enhanced CT images obtained through the level of the floor of the mouth in 2 different patients. Axial contrast-enhanced CT images obtained.
Potential Clinical Implications of the “Aortic Collar” Configuration of an Anomalous Left Brachiocephalic Vein  Amir Awwad, MBBCh, MRCS, Yutaro Higashi,
Pál Maurovich-Horvat et al. JIMG 2010;3:
T Salah, MD., M Saber, MBBCh., T ElTaweil, MD. and N Rasmy,MD.
Presentation transcript:

Quality of CT Images Acquired with Power Injection of an Arm Port Hager Haggag1, Christine Roh1, Ian Chan1, Brent Burbridge2, David Leswick2 1University of Saskatchewan Medical Students 2University of Saskatchewan, Department of Medical Imaging No conflicts of interest to declare

Learning Objectives Compare CT image quality with intravenous contrast injection via Angiodynamics arm ports versus conventional peripheral vein intravenous injection Offer guidance about whether to inject contrast via a port into the right atrium or to use a peripheral vein, when conducting a CT

Background The use of central venous catheters has increased dramatically over the past 40 years1. These devices are essential for many clinical treatments including access for chemotherapy, antibiotics, and blood transfusions2. Indwelling catheters terminating in a port are particularly useful for intermittent treatment for malignancies3. Advantages of ports include protection of the device from damage or infection by the overlying skin and a reduction in venipuncture injuries and infusion complications1,4,5. 1 Denny DF Jr. Placement and management of long-term central venous access catheters and ports. AJR Am J Roentgenol 1993;161:385–93. 2 Schiffer CA, Mangu PB, Wade JC, Camp-Sorrell D, Cope DG, El-Rayes BF, et al. Central venous catheter care for the patient with cancer: American Society of Clinical Oncology clinical practice guideline. J Clin Oncol 2013;31:1357–70. 3 Kawamura J, Nagayama S, Nomura A, Itami A, Okabe H, Sato S, et al. Long-term outcomes of peripheral arm ports implanted in patients with colorectal cancer. Int J Clin Oncol 2008;13:349–54. 4 Walser EM. Venous access ports: indications, implantation technique, follow-up, and complications. Cardiovasc Intervent Radiol 2012;35:751–64. 5 Burbridge B, Stoneham G, Szkup P, Otani R, Kriegler S. Catheter fracture and embolization associated with arm implantation of the cook vital port. Can Assoc Radiol J. 2013;64:369–73.

Introduction Smart Port® CT Mini Power-Injectable Port In this study, we investigated the Angiodynamics Vortex Smart Port Mini (Angiodynamics Inc., Manchester, GA, USA). These ports were inserted into the upper arm with the tip of the attached catheter at the right atrial/superior vena cava (SVC) junction. This particular arm port model is approved for power injection of computed tomography (CT) contrast agent, which has traditionally not been possible with other arm ports. Picture obtained from Angiodynamics website http://www.angiodynamics.com/products/smart-port-ct

Hypothesis CT image quality obtained via power port contrast injection is superior to images obtained via peripheral vein contrast injection. Reasoning: central delivery of contrast bolus would maintain tighter bolus of contrast while reducing streak artifact from concentrated contrast in the brachiocephalic veins, superior vena cava and right heart

Methods We performed a retrospective cohort study of patients who had a power injectable arm port inserted between July 2013 and June 2014. Ethics approval for this study was obtained from our local biomedical research committee (University of Saskatchewan Research Ethics Board) and data review was in compliance with the Health Information Protection Act (HIPA).

Methods Subjects were identified by reviewing a database of patients with an Angiodynamics arm port who had undergone contrast-enhanced CT (n=54). The majority of CT exams (n=44) were ‘mixed contrast phase’ studies of the chest, abdomen and pelvis (contrast present within the systemic arterial and portal venous systems). To reduce variability from timing of contrast bolus, we only assessed these studies. Only patients with a previous similar scan with contrast injection via a peripheral arm vein were included in the study (n=18). Therefore, each subject served as their own control.

Methods CT images were reviewed on Philips iSite Radiology Picture Archive and Communication System (Koninklijke Philips Electronics, Netherlands). Scan dates ranged between July 2012 to July 2014, with CT slice thickness ranging from 3.8 to 5 mm, and volume CT dose index (CTDIvol) ranging from 2.2 to 20.43 mGy. CT scans were from four acute care centres (Royal University Hospital, Saskatoon City Hospital, Cypress Regional Hospital, and Battlefords Union Hospital).

Methods Assessment of objective image quality was performed by measuring signal-to-noise (SNR) and contrast-to-noise (CNR) ratios, as described by Heyer et al1. SNR and CNR were determined at three anatomical levels: (1) aortic arch, (2) main pulmonary artery and right pulmonary artery and (3) descending aorta and left atrium. SNRstructure = SIstructure/BN CNRstructure = (SIstructure-SImuscle)/BN where SIstructure is signal intensity (SI) of a structure, SImuscle is mean SI of muscles, and BN is background noise 1 Heyer CM, Mohr PS, Lemburg SP, Peters SA, Nicolas V. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology 2007;245:577–83.

Methods – SNR and CNR SI values were calculated by measuring regions of interest (ROI), which were positioned to include adequate cross-sectional area of structures and avoid noise such as fat and bone. Muscle groups used to measure SI included the right and left pectoralis major, infraspinatus and serratus anterior muscles. A standard deviation of three ROIs in the surrounding air was used to determine background noise.

Example case. Patient with injection via left port line with tip right atrium Pulmonary artery level Background noise (SD HU) SI(main PA) (HU) SI(Right PA) (HU SI(muscle) (HU) Aortic arch level Background noise (SD HU) SI(arch) (HU) SI(muscle) (HU) Descending aorta level Background noise (SD HU) SI(desc Ao) (HU) SI(L atrium) (HU) SI(muscle) (HU) Location SNR CNR Arch 36.1 25.1 RPA 37.7 25.6 MPA 39.6 27.4 Desc Ao 30.0 19.4 L atrium 29.7 19.0 Patient with injection via left port line with tip right atrium

Statistical analysis Results Data analysis was performed using two-tailed t-tests in Microsoft Excel for Mac 2011 version 14.4.4 (Microsoft Corporation, Redmond, WA, USA). Results There were 18 subjects in our study 9 male, 9 female mean age 57.3 years [range, 26-84 years] 2 scans each (port and peripheral iv injection)

Results Tabular comparison of SNR & CNR at each site Aortic arch RPA MPA Descending aorta Left atrium Arm port Control SNR 29.2 ± 8.4 30.7 ± 8.4 27.7 ± 7.3 26.5 ± 8.3 28.3 ± 7.6 27.3 ± 8.5 23.5 ± 6.9 23.9 ± 7.3 25.1 ± 5.8 25.0 ± 7.1 CNR 19.8 ± 7.3 20.4 ± 7.9 20.4 ± 6.3 18.5 ± 8.3 21.0 ± 6.5 19.3 ± 8.2 16.6 ± 5.3 16.5 ± 6.9 18.2 ± 4.9 17.6 ± 6.7 T-test SRN: p=0.58 CRN: p=0.82 SRN: p=0.66 CRN: p=0.47 SRN: p=0.72 CRN: p=0.51 SRN: p=0.85 CRN: p=0.97 SRN: p=0.99 CRN: p=0.78 All SNR and CNR data presented as average ± standard deviation Fix table! SNR & CNR similar for both injection techniques at all locations No significant difference at any location (all p values >0.5)

Error bars represent standard deviation. All p values > 0.5 Results Graphical comparison of SNR & CNR at each site Error bars represent standard deviation. All p values > 0.5 SNR & CNR similar for both injection techniques at all sites No significant difference at any location (all p values >0.5)

Discussion There were no statistically significant differences in objective image quality. We had expected improved homogeneity of contrast opacification of the vessels with port injection because: More compact bolus of contrast with less mixing/swirling with unopacified blood Less noise from streak artifact from heavily concentrated contrast in the SVC and brachiocephalic veins during peripheral venous injection These potential benefits were out weighed by mixing of contrast during the phase assessed on these CT scans. However, this is the most common type of scan for these patients to receive

Conclusion There was no statistically significant difference in objective CT image quality for mixed phase contrast enhancement when contrast injection via peripheral vein was compared to power injection of an arm port. Power injection of a central venous catheter attached to an arm port is a safe and acceptable alternative strategy for contrast-enhanced CT1,2. Our work demonstrates that contrast injection via port has equivalent image quality when compared to conventional peripheral intravenous injection technique. 1 Herts B, O'Malley C, Wirth S, Lieber M, Pohlman B. Power injection of contrast media using central venous catheters: feasibility, safety, and efficacy. AJR Am J Roentgenol. 2001;176:447–453. 2 Plumb AAO, Murphy G. The use of central venous catheters for intravenous contrast injection for CT examinations. Br J Radiol. 2011;84(999):197–203.

Limitations This was a retrospective study and therefore we were not able to control for parameters such as CT scanner site, CT scanner design, protocols, and injection rates. There may have been variability in these parameters as we reviewed scans from four different acute care centers. Although this is a limitation, it also reflects real-world use of the port lines for injections in multiple centers. We performed comparison of CT images in the mixed phase of intravenous contrast enhancement. We suspect that the SNR and overall image quality would be better for the port group if the same comparison was performed for CT pulmonary embolism (PE) studies. We plan on exploring the possibility of superior image quality on CT PE studies in the future.

Acknowledgements Thank you for spending the time to read our presentation. We gratefully acknowledge: University of Saskatchewan College of Medicine and Department of Medical Imaging for guidance and supporting conference presentation costs. The CAR for giving us the opportunity to present at the 2015 Joint Congress on Medical imaging and Radiation Sciences Contact information: Hager Haggag: h.haggag@usask.ca Christine Roh: christine.roh@usask.ca Ian Chan: i.chan@usask.ca Brent Burbridge: brent.burbridge@usask.ca David Leswick: david.leswick@saskatoonhealthregion.ca