Investigation of Flow in a Model of Human Respiratory Tract

Slides:



Advertisements
Similar presentations
Bridging the Gap Between Statistics and Engineering Statistical calibration of CFD simulations in Urban street canyons with Experimental data Liora Malki-Epshtein.
Advertisements

Usefulness of velocity profiles based on 3D cine PC MR used as boundary conditions for computational fluid dynamics of an intracranial aneurysm : investigation.
* Re = 190 ∆ Re = 195 ○ Re = 214 * Re = 190 ∆ Re = 195 ○ Re = 214 Figure 3: PDF of droplet fluctuation velocity with mean subtracted and scaled by droplet.
Figure 1: Nasal Anatomy. Olfactory Cilia Superior Turbinate Internal Naris Nasopharynx Nasal Valve Middle Turbinate Inferior Turbinate Nostril © Philip.
On-Set of EHD Turbulence for Cylinder in Cross Flow Under Corona Discharges J.S. Chang, D. Brocilo, K. Urashima Dept. of Engineering Physics, McMaster.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques  Pipeline systems  Transmission lines  Pipe.
MAE513 Spring 2001 Prof. Hui Meng & Dr. David Song Dept. of Mechanical & Aerospace Engineering Advanced Diagnostics for Thermo- Fluids Laser Flow Diagnostics.
PIV Lung Model Test Setup December 14 th, Components Model Pump Pressure measurement Pressure control.
1 Copyright © 2011, Elsevier Inc. All rights Reserved. Computational Fluid Dynamics of Particle Transport and Deposition Chapter 2 Goodarz Ahmadi.
Jerzy Mizeraczyk XII INTERNATIONAL CONFERENCE ON ELECTROSTATIC PRECIPITATION Nuernberg May 9 – 13, 2011 Centre for Plasma and Laser Engineering The Szewalski.
Laser Anemometry P M V Subbarao Professor Mechanical Engineering Department Creation of A Picture of Complex Turbulent Flows…..
Study of Liquid Breakup Process in Solid Rocket Motors Author: Michael Stefik & Bryan Sinkovec, Co-Author: Yi Hsin Yen, Faculty Advisor: Professor Ryoichi.
Micro PIV  An optical diagnostic technique for microfluidics (e.g. MEMS, biological tissues, inkjet printer head) Requirements: Measure instantaneously.
University of South Carolina FCR Laboratory Dept. of Chemical Engineering By W. K. Lee, S. Shimpalee, J. Glandt and J. W. Van Zee Fuel Cell Research Laboratory.
Airflows and the spread of airborne pathogens in the ICU Dr Collette W
2009/1/6 Sensing and Actuation in Miniaturized systems Final report Hello everyone !!!!! I am Wu Chih-Wei !!!!!
RAY TRACING WITH DISPERSION CSS552 – Topics in Rendering Winter 2011 Final Project by: Kohei Ueda Shivani Srikanteshwara Mary Ann Chiramattel Kunjachan.
© 2010, TSI Incorporated Time Resolved PIV Systems.
Investigation of wall-bounded turbulence over sparsely distributed roughness M. Placidi, B. Ganapathisubramani and M. Tan Faculty of Engineering and the.
* University of Mining and Metallurgy, AGH Cracow Experimental and Numerical Investigations of Buoyancy Driven Instability in a Vertical Cylinder Tomasz.
Week 10: Imaging Flow Around a Radio Controlled Race Car
Viscous Flow Around Metal Spheres
Initial wave-field measurements in the Material Diagnostic Facility (MDF) Introduction : The Plasma Research Laboratory at the Australian National University.
Volumetric 3-Component Velocimetry (V3V)
URANS A PPROACH FOR O PEN - C HANNEL B IFURCATION F LOWS M ODELLING Adrien Momplot, Gislain Lipeme Kouyi, Emmanuel Mignot, Nicolas Rivière and Jean-Luc.
Particle Image Velocimetry (PIV) Introduction
1 Imaging Techniques for Flow and Motion Measurement Lecture 5 Lichuan Gui University of Mississippi 2011 Imaging & Recording Techniques.
Light microscopy for real-time characterization of colloids and nanoparticles Ivan V. Fedosov, Saratov State University, Saratov, Russia Boris N. Khlebtsov,
Lesson 21 Laminar and Turbulent Flow
GLASGOW 2003 INTEGRATING CFD AND EXPERIMENT A Detailed CFD and Experimental Investigation of a Benchmark Turbulent Backward Facing Step Flow Stephen Hall.
FLOW VISUALIZATION STUDY OF WORLDHEART LEVACOR TM VAD UNDER SYNCHRONOUS PULSATILE CONDITIONS Fangjun Shu, ♥  Stijn Vandenberghe, ♥ Philip J Miller  and.
Jet With No Cross Flow RANS Simulations of Unstart Due to Mass Injection J. Fike, K. Duraisamy, J. Alonso Acknowledgments This work was supported by the.
IESVic 1 QUANTITATIVE IMAGING OF MULTI-COMPONENT TURBULENT JETS Arash Ash Supervisors: Dr. Djilali Dr. Oshkai Institute for Integrated Energy Systems University.
Computational Fluid Dynamics Applied to the Analysis of 10-mm Hydrocyclone Solids Separation Performance S. A. Grady, M. M. Abdullah, and G. D. Wesson.
Ch 4 Fluids in Motion.
Revealing the True Nature of the Experiment  Comparison between 2- and 3-dimensional models reveals certain differences in morphology indicating additional.
Air filmcooling through laser drilled nozzles STW project CASA-dag
Particle Image Velocimetry Demo Outline (For reference) ‏ Topic NumberTopic NamePage Type 1Flow of PIVAnimated page.
Tony Arts Carlo Benocci Patrick Rambaud
MODERN FLUID FLOW MEASURING INSTRUMENT
Date of download: 6/3/2016 Copyright © 2016 SPIE. All rights reserved. Schematic setup of the DS-VHI system. Multicolor fluorescent planes within a tissue.
Date of download: 6/23/2016 Copyright © ASME. All rights reserved. From: Computational Fluid Dynamics Investigation of Turbulent Flow Inside a Rotary Double.
Presented to: International Aircraft Materials Fire Test Working Group By: Robert Ochs Date: Wednesday, October 21, 2009 Federal Aviation Administration.
Evidence of anisotropy of small scale turbulence in the laboratory model of an atmospheric cloud P.M. Korczyk, T.A. Kowalewski, S. P. Malinowski IPPT PAN,
Motion of a Fluid Particle (Kinematics)
Motion of a Fluid Particle (Kinematics)
Project Background The Army Medical Research Lab needs to validate their CFD models for healthy and diseased lungs RIT will perform particle image velocimetry.
Date of download: 10/9/2017 Copyright © ASME. All rights reserved.
Date of download: 10/9/2017 Copyright © ASME. All rights reserved.
Physics and Control of Shock Boundary Layer Interaction
Date of download: 10/21/2017 Copyright © ASME. All rights reserved.
Date of download: 10/22/2017 Copyright © ASME. All rights reserved.
Date of download: 12/19/2017 Copyright © ASME. All rights reserved.
Date of download: 12/26/2017 Copyright © ASME. All rights reserved.
Date of download: 1/1/2018 Copyright © ASME. All rights reserved.
Fluid Mechanics Dr. Mohsin Siddique Assistant Professor
From: Experimental and Numerical Validation of a Wind Gust Facility
Modeling and experimental study of coupled porous/channel flow
S. Ghosh, M. Muste, M. Marquardt, F. Stern
ASC/Alliances Center for Astrophysical Thermonuclear Flashes
Sunny Ri Li, Nasser Ashgriz
PIV Investigation of EHD Flow Caused by Field-enhanced Dissociation
Viscous Flow in Pipes.
CHAPTER 6 Viscous Flow in Pipes
Hui Wu Advanced Manufacturing Technology Research Laboratory
AN EXPERIMENTAL STUDY OF FLOW AROUND SURFACE-MOUNTED PYRAMIDS
Volume 105, Issue 2, Pages (July 2013)
In Vitro Flow Analysis of a Patient-Specific Intraatrial Total Cavopulmonary Connection  Diane A. de Zélicourt, MS, Kerem Pekkan, PhD, Lisa Wills, BS,
Fig. 1 Droplet transport on transverse wave surface topographies.
Quantitative Modeling and Optimization of Magnetic Tweezers
Presentation transcript:

Investigation of Flow in a Model of Human Respiratory Tract using PIV technique Nguyen Lu Phuong and Kazuhide Ito Interdisciplinary Graduate School of Engineering Sciences (IGSES), Kyushu University, Japan 1) Idealized model 2) Realistic model Fig 4. Plots of two dimensional mean velocity vectors in central sagittal plane. Otherwise, Figure 4(2) prove remarkable phenomenon of inclination of the flow to the anterior side of the trachea. Because of centrifugal force induced pressure gradient, the secondary motion of the fluid persisted in the posterior side when the airflow turned the bent from the upstream to downstream. Moving further to downstream of trachea region, the flow fields become well develops. Fig 1. Schematic representation of the in vitro experimental set-up for PIV measurement Introduction An investigation of air flow patterns will provide essential information to reveal how particles transported and deposited in the human respiratory tract. In this study, we conduct in vitro experiment to investigate the flow pattern in the idealized- and realistic- geometry of a human airway. Validation between PIV and CFD data u+ Idealized model Realistic model Fig 3. The in vitro model prototypes. Objective The working fluid condition in this experiment should have the same Reynolds number (Re) in both the numerical simulations and the experimental measurements. The relationship is given as follows: where Qmixture is the volumetric flow rate and ν, the kinematic viscosity. The Reynolds number for steady flow measurement was ~500 in this experiment. The in vitro experimental data is used to validate with computational fluid dynamics (CFD) results. 1) PIV data 2) CFD predictions Experimental Methods Fig 5. Contour of normalized two-component velocity magnitude u+ in central sagittal plane. Prototype Model Creation The computational realistic model was reproduced from CT data of a real human airway. The computational idealized model was simplified but constructed based on a realistic human airway model. Figure 5(1) and (2) shows velocity magnitude u+=u/uin with obtained by PIV and CFD, respectively. Velocity profiles in the trachea in both experiment and simulation were identified. The maximum simulated velocity found in the downstream smaller than experimental data. Overall, experimental data agree well with CFD predictions. Particle Image Velocimetry (PIV) technique A two-dimensional flow field was measured using hollow glass spheres (60 µm) as tracers for visualization. Tracer particle motions were captured using a high-speed Photron FASTCAM APX camera recording on a complementary metal-oxide-semiconductor (CMOS) sensor. The frame rate was basically 500 fps with a resolution of 512 × 1,024 pixels. A continuous wave (CW) laser (Beamtech Optronics, diode-pumped solid state (DPSS) green laser, 2 W, 532-nm wavelength) was used as a light source. The field of view of the CMOS camera could resolve a region of 26 mm × 52 mm by illuminating a light sheet of ~1-mm thickness discharged from the laser. Three-dimensional printer was employed to produce the realistic and idealized replica from the computational model. A prototype models were made from transparent acrylic material. Conclusion Experimental Setup A mixture of water and sodium polytungstate was used as a working fluid to match the refractive index of the flow and acrylic material constituting the airway model. The results show the different pattern of the flow between these models. The nature complex of realistic respiratory tract has great effects to flow patterns. This PIV data was used to validate with numerical results. A quantitative comparison between experimental and simulated velocity profiles will be performed in the trachea region. Contact: Dr. Kazuhide Ito Energy and Environmental Engineering Department IGSES, Kyushu University Phone: 092-583-7627 Email: ito@kyudai.jp Web page: http://www.phe-kyudai.jp Results The flow is characterized by the trachea section. In figure 4(1), the velocity vector distributions were almost uniform, and a relatively simple flow pattern was observed in idealized model. The vector map is almost identical and shows effect of straight tube to developed flow in the center of the trachea. Acknowledgements This project was supported by a Grant-in-Aid for Scientific Research (JSPS 21676005). Fig 2. Photograph depicting the accurate refracting index matching.