Neutron imager with Micro Channel Plates (MCP) in electrostatic mirror configuration: first experimental test V. Variale*, B. Skarbo2 1Istituto Nazionale.

Slides:



Advertisements
Similar presentations
Radioactivity.
Advertisements

GM COUNTER.
Geiger-Muller detector and Ionization chamber
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
NCEA Physics Thermionic emission.
Bunch shape monitor for Linac-4 A.V.Feschenko Institute For Nuclear Research (INR), Moscow , Russia.
Scint. Al Internal reflection External reflection ↑ ↑ ↑ Decay Detector Development for Giant Resonance Studies By: Gus Olson Mentor: Dr. D.H.Youngblood.
Technical studies for the HIE- ISOLDE Frontend upgrade Jacobo Montaño Marie Curie Fellow; CATHI Project * The research project has been supported by a.
N_TOF fission data of interest for ADS
1 Radiation Environment at Final Optics of HAPL Mohamed Sawan Fusion Technology Institute University of Wisconsin, Madison, WI HAPL GIMM Conference Call.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
6. Atomic and Nuclear Physics Chapter 6.6 Nuclear Physics.
Inertial Electrostatic Confinement Fusion Reactor Liquid Cooled Ion Accelerating Grid Design A. Seltzman, Georgia Institute of Technology Abstract: Reactor.
Correlation Analysis of Electrostatic Fluctuation between Central and End Cells in GAMMA 10 Y. Miyata, M. Yoshikawa, F. Yaguchi, M. Ichimura, T. Murakami.
CJ Barton Department of Physics INTAG Meeting – GSI – May 2007 Large Acceptance Bragg Detector at ISOLDE.
TITAN EBIT MCP Detector Assembly Cecilia Leung Undergrad summer student 2007 TRIUMF Summer Student Symposium Tuesday, July
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
VNIIA neutron generators for thermonuclear research
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Experimental part: Measurement the energy deposition profile for U ions with energies E=100 MeV/u - 1 GeV/u in iron and copper. Measurement the residual.
Systematic studies of neutrons produced in the Pb/U assembly irradiated by relativistic protons and deuterons. Vladimír Wagner Nuclear physics institute.
Multi-colour sctintillator-based ion beam profiler James Green, Oliver Ettlinger, David Neely (CLF / STFC) 2 nd Ion diagnostic workshop June 7-8 th.
Remon Ibrahim Remon Ibrahim High Energy Group.  Introduction  Experimental Techniques  Results  Conclusions Content.
Performance and applications of a  -TPC K. Miuchi a†, H. Kubo a, T. Nagayoshi a, Y. Okada a, R. Orito a, A. Takada a, A. Takeda a, T. Tanimori a, M. Ueno.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
INTERACTIONS OF RADIATION WITH MATTER. twCshttp:// twCs
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Luigi Cosentino - n_TOF collaboration meeting - Bologna - 27  29 November New monitors for flux measurement and n-beam profile in EAR2 Luigi Cosentino,
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Precision Drift Tube Detectors for High Counting Rates O. Kortner, H. Kroha, F. Legger, R. Richter Max-Planck-Institut für Physik, Munich, Germany A. Engl,
Christos Lamboudis HEP April. Athens Study of MDT response to neutrons and possible ageing effects Do we really need to worry about neutrons? Do.
SPES Target Group Data…… INFN-CISAS-CNR collaboration The Ablation Ion Source for refractory metal ion beams A preliminary design.
Patient is placed between X-ray tube and silver halide film.
Neutron imager and flux monitor based on Micro Channel Plates (MCP) in electrostatic mirror configuration Vincenzo Variale INFN-Bari, Italy  MCP detector.
PCS352 LAB #1 Characteristics of a Geiger Counter
Schematic of the experimental apparatus
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
Traps for antiprotons, electrons and positrons in the 5 T and 1 T magnetic fields G. Testera & Genoa group AEGIS main magnetic field (on axis) : from Alexei.
Introduction and Goals
Development of beam tracking detector using MicroChannel Plate(MCP)
Old Dominion University, Norfolk, Virginia 23529, USA
Performance of timing-RPC prototypes with relativistic heavy ions
Gas jet based diagnostics for beam monitoring
Frontier Detectors for Frontier Physics
Laboratory equipment Lecture (3).
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
Triple GEM detectors : measurements of stray neutron.
Shubin Liu, Binxiang Qi, Siyuan Ma, Zhongtao Shen, Guangyuan Yuan,
Diagnostics of FRIBs beam transport line
X-Radiation.
Multigap Resistive Plate Chambers (MRPC)
for collaboration “Energy plus transmutation”
Measurements of the 238U radiative capture cross section using C6D6
Electron-Beam Machining
Rutherford’s α scattering experiment
Particle Identification in LHCb
Background Reduction for Quantitative Gamma-ray Imaging with the Electron-Tracking Compton Camera in High Dose Areas May 26th, PS10A-10 T. Mizumoto,
1. Introduction Secondary Heavy charged particle (fragment) production
GEM-based neutron detectors including beam monitors
Pakistan Institute of Engineering and Applied Sciences (PIEAS)
Micro Resistive Well Detector for Large Area Tracking
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Neutron imager with Micro Channel Plates (MCP) in electrostatic mirror configuration: first experimental test V. Variale*, B. Skarbo2 1Istituto Nazionale Fisica Nucleare,INFN Sezione di Bari, Italy 2 Budcker Institute of Nuclear Physics, Novosibirsk, Russia * Vincenzo Variale. Tel.: +39 080 5442344; fax: +39 080 5443190. E-mail address: vincenzo.variale@ba.infn.it CAARI 2016, Fort Worth, Tx, USA

Abstract The idea of a new high transparency device based on Micro Channel Plate (MCP) has been recently presented for monitoring the flux and spatial profile of neutron beams. It consists of the assembly of a very thin aluminum (Al) foil with 6Li deposit placed in the beam and a MCP equipped with a phosphor screen readout viewed by a CCD camera. A peculiar feature of this device is that it uses a 90° electrostatic mirror to minimizing the perturbation on the neutron beam, i.e. absorption and scattering. It can be used at existing time-of-flight facilities, in particular, at the n_TOF facility at CERN, for monitoring the flux and spatial profile of neutron beams in the thermal and epithermal region. In this contribution the first experimental test carried out by using radioactive sources will be presented and the related results discussed. CAARI 2016, Fort Worth, Tx, USA

Introduction The MCP devices have many advantageous detection features as: fast time response (signal rise time about 300 ps); low dead time (for a diameter channel of 6mm about 100 ns); high counting rate (more than 108 sec-1); low dark current (for a vacuum better than 10-6 mb 1Hz/cm2); and a very high spatial resolution (6 mm per 1-stage MCP and 25 mm per 2-stage MCP, the chevron configuration) [1]. These features make the MCP very suitable to be used in beam profile monitor devices construction. The MCP radiation detection efficiency depends on the radiation type and energy. For the neutrons, however, they have a very low direct detection efficiency (up to 0.6% for fast neutrons). For that reason it is necessary of using other than the MCP also a converter material to increase the neutron detection efficiency. In the last years, MCP devices have been largely employed both for detection of ionizing radiation and as image intensifier. It has also been demonstrated that MCPs can be applied in neutron detection and imaging with many advantages [2,3,4]. Recently the idea of a new high transparency device based on MCP for monitoring the flux and the spatial profile of a neutron beam has been proposed [5]. In that reference the device design details are shown and discussed, here, for sake of clarity, the device behavior scheme is shown in fig.1 again. The device consisted of an Aluminum (Al) foil with a 6Li deposit, placed in the beam, and a MCP assembled with a phosphor screen readout viewed by a CCD camera, placed outside the beam. The reaction 6Li(n,a)t used as converter gives to the slow neutrons which hit the 6Li atoms a great chance to produce a and t ions with 2 and 2.7 MeV of energy, respectively. At those energies the a and the t particles have, in the Aluminum foil, a range of 5mm and 30 mm, respectively. Then, by taking an Al foil of which has a thickness of 14 mm, all the a particles are stopped and all the t transmitted. The tritons, then, exit from the Al foil and emit Secondary Electrons (SE) which are accelerated by the nearby grid and then reflected at 90°, towards the MCP, by the other grids tilted at 45° (electrostatic mirror). The SE impinging on the MCP inner channels generate an electron avalanche. Behind the MCP (in chevron configuration) there is the signal read-out system, a phosphor screen followed by a CCD camera where the beam image is recorded. In this paper the MCP based monitor test measurements carried out with radioactive sources are presented and discussed. CAARI 2016, Fort Worth, Tx, USA

Neutron beam monitor with Electrostatic Mirror (E. M Neutron beam monitor with Electrostatic Mirror (E.M.) configuration - Scheme Notice: as converter material the 6Li F deposited. on the Aluminum foil, has been used. In the figure , a 6Li atom hit by a neutron which produces the reaction 6Li(n,a)t is also shown . The Al foil used had a thickness of 14 mm and the 6Li deposit , a thickness of 1.6 mm. CAARI 2016, Fort Worth, Tx, USA

The experimental apparatus scheme The Neutron source : 252Cf with A=3.35x105 Bq The a source: 241Am with A=3 kBq Vacuum chamber with inside the Electrostatic Mirror. Notice: the radioactive sources positions used for the test measurements. CAARI 2016, Fort Worth, Tx, USA

Test measurement results with Neutron source (N.S.) the light points on the CCD camera represent the image of the neutron reactions happened in the converter in one second Signal without N.S. Background Signal with N. S. CCD camera snapshots of the light points representing the background radiation in a) (2 light points) and the nuclear reactions induced by the neutrons in the converter in b) (7 light points) CAARI 2016, Fort Worth, Tx, USA

Test measurement results with a Source CCD camera snapshots for the measurements with the a source. The light points on CCD camera represent the a hit Al foil Signal with Electrostatic Mirror off (background) Signal with electrostatic Mirror on In a) the CCD background signal, (4 light points with 2 light points less visible because of the figure size reduction) obtained when the electrostatic mirror was off (Vfoil=Vgrid= 0 V); in b) the CCD signal with electrostatic mirror on (Vfoil=Vgrid= -1 kV), about 100 light points (also here some light points was less visible and have been lost in the figure reduction). CAARI 2016, Fort Worth, Tx, USA

Summary experimental results Test measurements with Neutron Source: r = 3.4 ±0.02 s-1 (Back ground) without Neutron source : r = 1.7 ±0.01 s-1 Test measurements with a Source and Vf=Vg= -1kV (E. M. on): r = 120 ±6 s-1 Test measurements wit a Source and Vf=Vg= 0 V (E. M. off) : r = 2.74 ±0.16 s-1 Notice, it corresponds to a Back ground signal in the presence of the a Source CAARI 2016, Fort Worth, Tx, USA

Possible CORONA effect In order to optimize the values of the applied potentials, further test measurements with higher voltages on foil converter and reflecting grids have been carried out. The results of those measurements have shown that when the voltage was bigger than -1.5 kV an increase of the light points on the CCD camera signal was observed Notice: the vacuum chamber pressure measured during all the experimental tests was in the range 3 ÷ 5 x10-7 mb. No Corona Effect was expected with a such low pressure but, unfortunately, the grid cards are made by glass fiber composite material RF4 not suitable for high vacuum. Atoms desorbed from grid surfaces could have been ionized by the high electric fields present close to the grid wires. CAARI 2016, Fort Worth, Tx, USA

Test on Neutron Beam a) b) For the test on the neutron beam at n_TOF facility of CERN, some modification on the Electrostatic Mirror support was needed: a) b) Notice no hindrances on the beam axis Beam monitor assembled on only one flange: a) the modified support system on the new larger flange which host also the MCP assembly; b) the new flange closed on the new vacuum chamber and on it the CCD camera is installed. CAARI 2016, Fort Worth, Tx, USA

Conclusion Before to test the proposed high transparency neutron beam monitor directly on the neutron beam of n_TOF CERN facility, an experimental test on his behavior has been carried out in our laboratory by using radiation sources. The experimental tests have shown that the electrostatic mirror used to convey the neutron image, obtained by the Secondary Electrons, toward the MCP assembly placed off beam axis worked well. Possible corona effects could be observed on CCD camera display when the deflecting grid voltage was higher than -1.5 kV. The same effect at a A lower level it is visible when the converter foil voltage was higher than -2 kV. References [1] J. L. Wiza, Nucl. Instr. And Meth. 162 (1979) 587. [2] G. W. Fraser and J. F. Pearson, , Nucl. Instr. And Meth. A293 (1990) 569. [3] O. H. W. Siegmund, A. S. Tremsin, J. V. Vallerga, J. Hull, IEEE Trans. Nucl.Sci. NS-48 (2001) 430. [4] A. S. Tremsin, W. B. Feller, R. G. Downing, , Nucl. Instr. And Meth. A539 (2005) 278. [5] V. Variale, Physics Procedia 66 (2015) 242-248 [6] MCNPX report manual CAARI 2016, Fort Worth, Tx, USA