Burst Test Test-Bed LHC120A-10V 4 Quadrant Converter: Burst Tests

Slides:



Advertisements
Similar presentations
Lecture 2 Operational Amplifiers
Advertisements

Basic Knowledge of Data Converters
CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
MineralScan Lite Installation Guidelines Digital Control Lab, LLC NW 6 th Street, Suite F Gainesville, FL Main Unit power 90 – 240 VAC 50/60.
Designing a EMC Compatible Electronic Meter using AD7755 a.
Oct. 10th 2006NSLS II Accelerator System Advisory Meeting SR-PS 1 NSLS II Accelerator System Advisory Committee Meeting October 10 – NSLS II Storage.
Operational Amplifiers
ELECTRONICS PRIMER. Assignment: WEB-based Electronics Tutorial Basic definitions Components Ohm's Law LEDs and Transistors Additional electronics tutorials.
David MacNair POWER SUPPLY 3/30/20061 Ethernet Power Supply Controller.
Powering the main linac implications Daniel Siemaszko, Serge Pittet OUTLINE : Cost impact of power converters, power consumption and powering.
Electronic Instrumentation & PLC DKT 314 Digital thermometer LCD display using LM35 Lecturer: En Mat Nor Mohamad B Ismail En Zulkifli Husin.
Data Acquisition Systems
18-20 December rd ATF2 Meeting, KEK ATF2 Power Supplies1 ATF2 High Availability DC Magnet Power Supplies By Paul Bellomo, Antonio de Lira, David.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 9 Computer-Based Instrumentation.
IPC Power Distribution Considerations A predominately important factor that should be considered in the design of a printed board is power distribution.
Non - Inverting Amplifier
Thurel Yves – CERN / Chamonix 2010
©F.M. Rietti Components Fundamentals. ©F.M. Rietti LM-18 Computer Science SSI Embedded Systems I 2 Active Components (cont) Comparator –if V2 > V1 the.
NameFIELDS iPDR – Subject Solar Probe Plus FIELDS Instrument PDR Antenna Electronics Box Selda S. Heavner U.C. Berkeley 1.
1 BROOKHAVEN SCIENCE ASSOCIATES Power Supply Status George Ganetis Power Supply Status ASAC Review October 22-23, 2009.
Grounding.
Instrumentation Amplifiers Passive Transducer Measurement Configuration: For passive transducers in a bridge configuration the voltage of interest is the.
Powering the damping rings wigglers Daniel Siemaszko, Serge Pittet OUTLINE : Powering superconductive magnets, Powering wigglers strategy, Existing.
0808/0809 ADC. Block Diagram ADC ADC0808/ADC Bit μP Compatible A/D Converters with 8-Channel Multiplexer The 8-bit A/D converter uses successive.
EMC issues for cabling and racks layout design. (Belle II – Grounding) F.Arteche.
F. Arteche EMC: Electronics system integration for HEP experiments (Grounding & Shielding)
Lecture Notes / PPT UNIT III
1 Summary Lecture: Part 1 Sensor Readout Electronics and Data Conversion Discovering Sensor Networks: Applications in Structural Health Monitoring.
الأسبوع الخامس والعشرين مغيرات الجهد المتناوب Ac voltage converter مغيرات الجهد المتناوب Ac voltage converter.
Belle-II bKLM RPC Readout Power & Ground Discussion 12 th Belle II General Meeting Gerard Visser Indiana University CEEM 7/24/2012.
Developing a Sonar Sub-System for a Submarine to Obtain Time Delays between Received Signals Gary Eades Dy Eang Diana Fuertes 12/04/2007 ECE4884 L03 Dr.
EMC review for Belle II (Grounding & shielding plans) PXD system - July 2012 Dr. Fernando Arteche.
TRANSFORMERS  A power station produces an AC pd of ~25 kV  This AC pd is stepped up to ~132 kV so that it can transport through cables without losing.
ELECTRONICS PRIMER.
3. Signal conditioning Sensors are very rarely directly connected to the registering instruments, as the signal may be too weak, incompatible or noisy.
CR Dipole Magnets Power converter concept
Quiz: AC & DC Specifications TIPL 4002 TI Precision Labs – ADCs
ZTF Grounding or Yes, there are two paths you can go by
Electronic Devices Ninth Edition Floyd Chapter 14.
EET 2259 Unit 12 Data Acquisition
INSTITUTE & TECHNOLOGY
What is a DAC? A digital to analog converter (DAC) converts a digital signal to an analog voltage or current output DAC.
High precision specification and test of power converters at CERN
Common Base and Common Collector Amplifiers
Grounding.
FGM CDR FGM Electronics (FGE) Ronald Kroth MAGSON GmbH Berlin Germany.
(2) Bridge Circuits.
Data Acquisition System
Analogue Electronic 2 EMT 212
Feedback No feedback : Open loop (used in comparators)
Chapter 13 Linear-Digital ICs
UNIT-5 Design of CMOS Op Amps.
What is an Op-Amp Low cost integrating circuit consisting of:
Meeting on Services and Power Supplies
Operational Amplifiers (Op Amps) in Chemical Instrumentation
MALVINO Electronic PRINCIPLES SIXTH EDITION.
Principles & Applications
Industrial Electronics
Operational Amplifiers in Chemical Instrumentation
EET 2259 Unit 12 Data Acquisition
Engineering 4862 Microprocessors Lecture 25
HCAL HV splice box.
Digital to Analog Converters (DAC)
Conversation between Analogue and Digital System
Analog versus Digital Systems
Electronic PRINCIPLES
Electronic PRINCIPLES
Which of the following devices or circuits changes an alternating current into a varying direct current signal? A. Transformer B. Rectifier C. Amplifier.
ELECTRONICS II 3rd SEMESTER ELECTRICAL
Chapter 7 Converters.
Presentation transcript:

Burst Test Test-Bed LHC120A-10V 4 Quadrant Converter: Burst Tests A converter is tested on all cables. Test specifically on “High Precision analog sensor cable” is done to show “Low Impedance 360° shielding” efficiency. Iout AC Mains Supply Power Part Voltage Source Vout A B Earth Circuit Vref I.A Control WorldFip - I ref - Digital Electronic Current Transducers I.B DCCT Cable 4kV E.U.T This cable is really critical since ensuring integrity of analog high precision measured current used in loop regulation. Analog value is digitalized in the Digital Electronic though a 16bit Sigma Delta ADC. Current loop is then numeric, and provides voltage reference to the power converter acting as a power amplifier. Burst Generator Rack is only connected to ground by AC cable Ground Copper Plane Immunity CEM RF & Hyper Europe 2008 1st October 2008 Y. Thurel

Burst Test Results @ 120A DC LHC120A-10V 4 Quadrant Converter: Burst Tests I.Meas (1kHz sampling) Burst Test Results @ 120A DC 4kV Burst OFF Result of Burst test with adequate connector shielding: 4kV impact is not measurable. 2 ppm 4kV Burst On A standard “queue de cochon” applied: shielding is degraded: 100ppm of error!!! Cable Shielding continuity to connector = 2 cm path 100 ppm 4kV Burst On Shielding not connected to connector is equal to “pig tail” case!!!! 100ppm of error!!! No Cable Shielding continuity with connector 600 ppm 4kV Burst On Immunity: Shielding Quality Impact CEM RF & Hyper Europe 2008 1st October 2008 Y. Thurel