On the evaluation of multifocal IOLs by means of a vision simulator

Slides:



Advertisements
Similar presentations
Dr H. Razmjoo Isfahan University of Medical Sciences Multifocal IOLs
Advertisements

Monovision for Presbyopia Insert name/ Practice name/ Logo here if desired.
Goals of Cataract Surgery Provide a Full Range of Vision Minimize Dependence on Glasses Including Reading Glasses and Bifocals Improve Lifestyle Activities.
Diffractive Multifocal IOL Prof. Dr. Daniel H. Scorsetti
Keiichiro Minami, Hiroko Bissen-Miyajima, Mami Yoshino, Kunihiko Nakamura Department of Ophthalmology Tokyo Dental College Suidobashi Hospital, Tokyo,
The new Akreos MI 60 lens Joel Pynson, MD - Director Design Engineering Bausch & Lomb, Toulouse - France London, September 9th 2006.
Visual outcome & subjective visual symptoms of the Tecnis ZM900 multifocal intraocular lens in Asian eyes Dr Colin S.H. Tan MBBS, MMed (Ophth), FRCSEd.
Multifocal Intraocular Lenses & Contrast Sensitivity
NEW TRULIGN™ TORIC IOL Surgeon Training
CLINICAL OUTCOMES WITH A NEW DIFFRACTIVE MULTIFOCAL INTRAOCULAR LENS (IOL) Pilar Casas de Llera Ana Belen Plaza Alfredo Vega-Estrada Jorge L Alio Vissum.
Eltutar, Kadir; Akcetin, Tulay A.; Ozcelik, N. Demet Istanbul Education and Research Hospital Department of Ophthalmology The authors state that they have.
Ruth Lapid-Gortzak MD PhD 1,2, Jan Willem van der Linden BOpt 2, and Ivanka J. van der Meulen MD 1,2 1 Department of Ophthalmology, Academic Medical Center,
Progressive Multifocal Intraocular Lens G. Rubiolini M.D. Italy Disclosure of finanacial interest Author's research is partially funded.
BLOC 5: MULTIFOCAL LENSES Subject 16.- Multifocal lenses. Classification. Subject 17.- Bifocal lenses. Subject 18.- Progressive addition lenses.
REFRACTIVE ASPECTS OF CATARACT SURGERY. OPTICAL CORRECTIONS AFTER CATARACT EXTRACTION.
Visualized light paths in different multifocal
Recent Advances in Intraocular Lenses Jim Schwiegerling, PhD Ophthalmology & Vision Sciences Optical Sciences.
Presbyopic Refractive Surgery Update 2015 Claes Feinbaum MSc PhD Barzilaii Medical Center, Ashkelon, Israel Vision4You.
Blended vision after bilateral monofocal cataract surgery: an evaluation of spectacle independence and vision related quality of life Allison Landes, MD.
For Accommodative Lenses Deepak Chitkara, M.B., ChB. D.O.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Clinical and simulation outcomes of a multifocal intraocular lens with rotational asymmetry and two different levels of near addition Jorge Alió, MD,PhD.
Kaori Morii, M.D. Shinji Miura, M.D, Ph.D. Dept. of Ophthalmology, Asagiri Hospital, Hyogo, JPN We have no financial interest. This retrospective study.
A case of hypermature cataract formation following implantation of a posterior chamber phakic intraocular lens with a central hole The Catholic University.
Effect of Ocular Deviation on Pupil size with Implanted Multifocal Intraocular Lens Yoshihiko Iida, MDKimiya Shimizu, MD Misae Ito, CO Kitasato University.
Advanced Optics for Ophthalmology
Contrast sensitivity testing maybe a better estimate of real life visual performance when compared to Snellen acuity testing Contrast sensitivity maybe.
Binocular Defocus Curve of Apodized Diffractive Multifocal IOL in Asian-Indian Eyes Dr.A. Shetty; Dr. M. K. Kummelil; Dr. S.Nagappa Cataract and Refractive.
DGII 2008 Comparison of Aspheric ReSTOR and Tecnis multifocal IOL Dongho Lee MD, PhD Yonsei eye center, Seoul, South Korea No Financial Interest.
Multifocal Intraocular Lenses Abdullah Al-assiri Mansour Farooqui Abdulrahman Al-Muammar Saudi Ophthalmology Meeting 2009.
AcrySof ® ReSTOR ® Aspheric IOL. Aspheric IOL AcrySof ® ReSTOR ® 2 AcrySof ® ReSTOR ® Aspheric IOL SN6AD3 Add Power: +4 D Spectacle Plane: 3.2 D Range:
Controversies about binocular function and patient satisfaction after induced conventional monovision in case of bilateral intraocular lens implantation.
Analyze Effects of Multifocal Intraocular Lenses on Potential Acuity Meter and Perimetry Testing G. Yuricek Aylin Sarac S.A. Erzurum, MD, FACS.
S. Lee/M.Kim 2010 M. Kim 1, H. Lee 1, S. Lee 1,, S.D. Lee 1 1 ASA-Vision Clinics Seoul Comparative Analysis Preliminary Results of.
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
AcrySof ® ReSTOR ® Apodized Diffractive IOL. What is the AcrySof ® ReSTOR ® IOL? The AcrySof ® ReSTOR ® IOL incorporates an apodized diffractive optic.
Variations in refractive analysis with different diffractive multifocal intraocular lenses using different wavefront analyzers Mami Yoshino, Hiroko Bissen-Miyajima,
Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.
Comparison of 2 Models of Aspheric Diffractive Multifocal IOL
Investigation of Multifocal Toric IOLs to Compensate for Corneal Astigmatism and to Provide Near, Intermediate, and Distance Vision José L. Rincón, MD.
Preliminary Results after Cataract Surgery with the Aspheric Acrysof ReSTOR IOL to Correct Presbyopia Meeting of the ASCRS Chicago 8-10 February 2007 R.M.M.A.
Warren Hill, MD, FACS East Valley Ophthalmology 5620 E. Broadway Road
Toric IOLs: wavefront aberrometry and quality of life Mencucci Rita Giordano Cristina, Stiko Ermelinda, Miranda Paolo, Eleonora Favuzza, Ugo Menchini Authors.
9-Month Results after Implantation of a new accommodative IOL that works with one focus Mark Tomalla M.D.* Clinic for Refractive and Ophthalmic Surgery,
F.I. Camesasca, MD Zeiss Invent ZO Aspheric IOL: Long-Term Results of Refractive and Aberrometric Analysis F. I. Camesasca* P. Vinciguerra.
Date of download: 5/30/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Quantitative Performance of Bifocal and Multifocal.
"Mix and Match" approach implantation
Date of download: 6/24/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Prospective Long-term Evaluation of the Efficacy,
Vinohrady Teaching Hospital, Prague, Czech Republic Vinohrady Teaching Hospital, Prague, Czech Republic M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD,
Poster Nr. Novel bifocal macular lens may restore reading vision in eyes with maculopathies Nicole Horchi, Hermann Anhalm, Martin Lörtscher, Carsten.
Multifocal Corneal Excimer Ablations for Presbyopia
Postoperative Refraction and Patient Satisfaction after Bilateral Implantation of Presbyopia-Correcting Intraocular Lenses Robert Cionni, MD Financial.
Hayashi Eye Hospital, Fukuoka, Japan
From: Binocular visual acuity for the correction of spherical aberration in polychromatic and monochromatic light Journal of Vision. 2014;14(2):8. doi: /
Intermediate Vision After Presbyopia Correction
D. Breyer, H. Kaymak, K. Klabe Düsseldorf, Germany ASCRS 2010, Boston
Pablo Artal, Encarna Alcón, Eloy Villegas, Carmen Cánovas, Elena Rubio
Pablo Artal, Eloy Villegas, Encarna Alcón, Inés Yago. , Elena Rubio
Clinical results of the aphakia correction using iris-fixated anterior chamber intraocular lens (Artisan) Authors have no financial interest Luis Izquierdo.
Long Term Clinical Outcomes of Refractive Lens Exchange in Moderate     to High Hyperopia Frank Goes, BELGIUM Ascrs 2008.
Thomas Kohnen, MD Department of Ophthalmology
Comparison of vision with an accommodating IOL versus a multifocal IOL
INTRAOCULAR LENS IMPLANT System Description and Diagram (task 2)
Results of corrective surgery: secondary lens implantation at a cataract surgery training centre Mehul Shah,shreya shah, adway appalware,pramod upadhyay,
David T. Vroman, MD Assistant Professor of Ophthalmology
Refractive errors.
The authors have no financial interest
Comparative Global Literature Review of Visual and Optical Quality of Refractive, Diffractive, and Hybrid IOL Designs James P. McCulley, MD Department.
“Accommodating IOL Implantation Experience”
Michael Goodman, Alexandra Paul and Andrew Hsu
Presentation transcript:

On the evaluation of multifocal IOLs by means of a vision simulator anna.giner-tort@cd6.upc.edu Anna Giner, Mikel Aldaba, Montserrat Arjona, Jaume Pujol CD6: Centre for Sensors, Instruments and Systems development – Universitat Politècnica de Catalunya (Barcelona Tech), Terrassa, Barcelona, Spain. INTRODUCTION Multifocal Intraocular Lenses (MIOLs) are one of the possible solutions to solve presbyopia and cataracts at the same time. Attributable to the several foci and the IOL design, MIOLs show certain disadvantages as the adaptation, contrast sensitivity reduction and halos. A new instrument designed for vision emulation through IOL Lenses (VirtIOL, 101Lens S.L.U) has been recently developed to predict the performance of the IOLs before implantation. The main goal of the present study has been to evaluate the performance of a new design and a commercial multifocal intraocular lens by means of the VirtIOL vision simulator. MATERIAL AND METHODS VirtIOL vision simulator: is an instrument based on projecting an IOL onto the patients’ pupil plane (Figure 1). There is no magnification effect and the refraction is compensated for far vision. IOLs: three MIOLs and one monofocal IOL were tested in this study (Table 1). Patient and operator: all the measurements were performed by the same operator and the same well trained observer, who is a male 54 years old. All measurements were performed with his left eye. VT ME IOL L M E D P C IOL Manufacturer Power Addition NDIO L –CN (MIOL) OPHTEC +20.00D +2.75D NDIOL – CF (MIOL) MPlus (MIOL) Oculentis +3.00D Artisan Aphakia (Monofocal IOL) - Table 1: Technical specifications of the IOLs. Protocol: All the following tests were performed 3 times for each lens. Visual Acuity (VA) was evaluated by means of a through-focus scanning from far (0D) to near vision (-3D) in 0.5D steps. VA for far and near vision with different levels of contrast, 100%, 25% and 10% by means of Sloan letter charts. Evaluation of decentration and rotation effect, inducing ±0.5mm in x and y axis and rotating the artificial eye 0º, 120º and 240º respectively. Performance of each lens under natural (4mm) and 3mm pupil Figure 1: Set-up scheme where: VT. Vision Test; ME. Model Eye; IOL. IOL submerged in water; L. Lens; M. Mirror; P. Variable Pupil E. Patient’s eye; D. Display; C. Camera. RESULTS Throughfocus Scanning Figure 3: Visual Acuity (logMAR) at far and near vision of the Mplus (MP) and the NDIOL-CF (ND) MIOLs for each angle to study the rotational effect. Figure 4: Mean absolute difference of VA (logMAR) between central position and decentered positions from the optical axis (mm) of each MIOL. Figure 2.: Visual acuity results for the throughfocus scanning for all lenses with natural pupils in high luminance conditions and 100% of contrast. MIOL 100% Contrast 25% Contrast 10% Contrast FVA ± SD NVA ± SD Monofocal (Artis.) -0.20 ± 0.00 0.50 ± 0.00 -0.17 ± 0.00 0.53 ± 0.00 0.04 ± 0.00 0.73 ± 0.00 NDIOL –CF -0.10 ± 0.05 -0.03 ± 0.05 0.03 ± 0.05 0.10 ± 0.05 0.17 ± 0.05 NDIOL –CN -0.07 ± 0.05 0.06 ± 0.05 0.13 ± 0.05 MPlus -0.10 ± 0.00 -0.05 ± 0.07 0.15 ± 0.05 MIOL Natural Pupil 3mm Pupil FVA ± SD DVA ± SD NDIOL-CF -0.10 ± 0.05 -0.02 ± 0.05 MPlus -0.10 ± 0.00 -0.15 ± 0.05 Table 3: Far Visual Acuity (DVA) ± SD in LogMAR units for each pupil size (3mm and Natural) in high luminance conditions. Table 2: Far Visual Acuity (FVA) and Near Visual Acuity (NVA) in LogMAR units for each contrast level (100%, 25% and 10%) in high luminance conditions. CONCLUSIONS VirtIOL vision simulator can emulate any IOL design, even the more complex as are MIOLs. Throughfocus showed a bifocal behaviour for the meausred MIOLs (Figure 2). Good levels of VA were found for FV and NV for all measured MIOLs with 100% contrast. In terms of 25% and 10% contrast one line per level was increased also in far and near vision (Table 2). There was no or little impact of the positioning errors on the visual performance of the IOLs (Figure 4). There was effect on the visual performance when measuring at different rotation positions in the M-Plus lens (Figure 3). When measuring with small pupils, M-Plus lens increased the VA, meanwhile, NDIOL lens decreased it (Table 3). The simulations through VirtIOL in the preliminary steps of the NDIOL development helped in a design improvement of the lens. ACKNOWLEDGEMENTS This study was funded by the Spanish Ministry of Science and Innovation with the project grant DPI2011-30090-C02-01, and the European Union. A. Giner thanks the Ministerio de Economía y Competitividad for the PhD grant she received.