Calorimeter for absolute luminosity at upgraded DAFNE

Slides:



Advertisements
Similar presentations
ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
Advertisements

DCS meeting, CERN, 17 June 2002Børge Svane Nielsen, NBI1 Forward Detectors DCS Forward Detectors (FWD): T0- quartz Cherenkov V0 - plastic scintillator.
SoLID EC Design for IHEP 2012/10. Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
1. introduction 2. goal of luminosity monitor 3. Structure of BESII Luminosity detector 4. Calculation of the luminosity 5. MC of luminosity detector 6.
0 The LHCb Hadron Calorimeter Rustem Dzhelyadin, (IHEP, Protvino) INSTR02 Conference, BNPI, Novosibirsk, Russia Contents: Œ Design overview  Trigger with.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
EAS Reconstruction with Cerenkov Photons Shower Simulation Reconstruction Algorithm Toy MC Study Two Detector Configuration Summary M.Z. Wang and C.C.
Electromagnetic Calorimeter for the CLAS12 Forward Detector S. Stepanyan (JLAB) Collaborating institutions: Yerevan Physics Institute (Armenia) James Madison.
Start Counter Collaboration Meeting September 2004 W. Boeglin FIU.
CMS Calorimeter HB- HB+ HE- HE+ HF- HF+ HO-2 HO-1 HO0 HO+1 HO+2
May 1-3, LHC 2003V. Daniel Elvira1 CMS: Hadronic Calorimetry & Jet/ Performance V. Daniel Elvira Fermilab.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
The NA62 rare kaon decay experiment Photon Veto System Vito Palladino for NA62 Coll.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
VVS Prototype Construction at Fermilab Erik Ramberg 26 February,2002 Design issues for VVS Details of VVS prototype design Schedule and Budget Testing.
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
7/28/2003DC/EC Review Aerogel Read out Electronics K. Ozawa, N. Kurihara, M. Inaba, H. Masui T. Sakaguchi, T. Matsumoto.
Progress on the beam tracking instrumentation Position measurement device Tests performed and their resolution Decision on electronics Summary.
Jefferson Laboratory Hall A SuperBigBite Spectrometer Data Acquisition System Alexandre Camsonne APS DNP 2013 October 24 th 2013 Hall A Jefferson Laboratory.
Progress on F  with the KLOE experiment (untagged) Federico Nguyen Università Roma TRE February 27 th 2006.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
MAMUD Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, March 29, 2005 Purpose:  Provide pion – muon separation.
R.S. Orr 2009 TRIUMF Summer Institute
Luminosity Monitoring Issues  ZDC  what’s the advantage?  problems  BBC  can they do it? A. Drees QCD critical point workshop, Mar
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
Working group on photon vetoes Meeting on June 7 th : 1.Status of Geant4 simulations 2.Discussion on LAV structure 3.Discussion on readout 4.News on Spaghetti.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
Gas detectors in a ZDC (at LHC) Edwin Norbeck and Yasar Onel University of Iowa For7 th CMS Heavy-Ion meeting at Delphi June 2003.
A Brand new neutrino detector 「 SciBar 」 (2) Y. Takubo (Osaka) - Readout Electronics - Introduction Readout electronics Cosmic ray trigger modules Conclusion.
Prototypes photon veto detectors for NA62 experiment CERN M. Raggi - INFN/Frascati for the NA62 Photon Veto Working Group LNF, RM1, NA, PI, SOFIA First.
M.D. Nov 27th 2002M0' workshop1 M0’ linearity study  Contents : Electronic injection Laser injection Beam injection Conclusion.
SuperB workshop SLAC, October 6, Outline Present Design Some thoughts about tile production Updated cost estimate Light yield studies of 3 mm thick.
A.PasseriHigh granularity Pb-SciFi calorimeter1 Construction and tests of a fine granularity lead-scintillating fibers calorimeter P.Branchini, F.Ceradini,
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
LumiCal High density compact calorimeter at the ILC Wojciech Wierba Institute of Nuclear Physics PAS Cracow, Poland.
 13 Readout Electronics A First Look 28-Jan-2004.
G. Mazzitelli – Beijing, China 26 May Diagnostics for the crab waist test at DAFNE, first result Manuela Boscolo, Fabio Bossi, Bruno Buonomo, Giovanni.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Feb C.Smith UVA EC energy calibration – g13 pass0 For pass0 data were cooked with CALDB calibration constants reset to nominal 10 channels / MeV.
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
FSC status and plans Pavel Semenov IHEP, Protvino
FCAL R&D towards a prototype of very compact calorimeter
on behalf of ATLAS LAr Endcap Group
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
The ATLAS Zero Degree Calorimeter Brookhaven National Laboratory, USA
IFR detector mechanics
PCAL Cosmic Ray Tests Progress Report C. Smith μ U V W MODULE 2
CMS ECAL Calibration and Test Beam Results
CLAS12 Forward Detector Element PCAL
SIDDHARTA Setup SIDDHARTA Kaon monitor focusing quads bhabha monitor
Status report of the tile-Si Lccal* project
Luminosity measurement at DAFNE
Conceptual design and R&D Progress of STCF ECAL
Michele Faucci Giannelli
The Measurement of Forward Particle Production in LHC
Update on CaloLUMI [ ] rate = (event2-event1)/Dt
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
Quad-calorimeter for KLOE-2
Presentation transcript:

Calorimeter for absolute luminosity at upgraded DAFNE P. Branchini, 30 May 2008

LumiCalo requirements: It should be able to clearly identify Bhabha events. It should provide time and energy information. It should be a self triggering device. It should be cheap. P. Branchini, 30 May 2008

LumiCalo design: resolution Back in Jan. 2007 we were discussing the kind of energy resolution that we would have desired, in order to separate Bhabha events with a cut on energy, e.g. at half energy of a Bhabha: 250 MeV. We established then a target resolution of about s(E)/E ~ 15%/E P. Branchini, 30 May 2008

First design Considerations that have driven the very first design of our calorimeters: ring shaped around the interaction region well defined acceptance, especially in q and at lower angles extend to minimum radius [quadrupole] and maximum q [Siddharta] good f coverage to maximize rate [for fast feedback] four half-rings, two on each side of the IP for simple back-to-back trigger logic s(E)/E ~ 20% at 510 MeV From G. Mazzitelli log-book P. Branchini, 30 May 2008

LumiCalo design: segmentation Excluded the all-crystals solution, both for practical and budget reasons; Given the limitations on the total depth due to the presence of Siddharta and of the quadrupoles, we have optimized the sampling fraction of our calorimeter In the end, we used lead in place of tungsten mainly for budget reasons P. Branchini, 30 May 2008

Final design Longitudinal segmentation has been optimized keeping in mind that the total available depth is the length of the quadrupole  20 cm 11 absorber plates + 12 samplings: 8×0.5 cm + 3×1 cm lead  12.5 X0 should ensure sufficient shower containment 12×1 cm scintillator 2:1 active:passive ratio should ensure 15%/E(GeV) resolution Lateral segmentation dictated by the need of keeping a reasonable number of channels and to have some degree of freedom in defining the acceptance We decided to instrument only 10 out of 12 sectors, keeping out the f=0º-180º plane, since we were expecting larger backgrounds from there P. Branchini, 30 May 2008

LumiCalo design: WLS fibers Finalized design of tiles: Feb. 2007. We have chosen Protvino scintillator: IHEP SC-307, 30 ph.el./MeV nominal light yield First design for wavelength-shifting fiber readout, sigma-shaped, changed to three longitudinal fibers with the advantage of: Simpler production of tiles with linear grooves Same or better light collection: shorter fibers, better collection by middle fiber Divide light from one tile on three fibers: less sensitivity to broken fibers P. Branchini, 30 May 2008

Tiles and WLS fibers Groove designed for optimal matching with 1.0 mm fibers 2 mm depth, 1.1 mm diameter Each tile wrapped with Dupont TyvekTM sheet to improve light collection P. Branchini, 30 May 2008

CaloLumi construction The mechanical structure and all the details have been realized by the Frascati workshop many thanks to: Luciano Iannotti, Vittorio Romano and G. Sensolini. P. Branchini, 30 May 2008

CaloLumi installation Cables and all connections for front-end electronics have been realized by Oscar Coiro and Claudio Mencarelli P. Branchini, 30 May 2008

CaloLumi installed P. Branchini, 30 May 2008

CaloLumi DAQ The DAQ is based on the KLOE system. The analog signal is split, we acquire charge and time and we also use the signal from the pmts to assert the trigger. P. Branchini, 30 May 2008

Linearity Module 0 btf calibration results. The trigger asserted used the rf signal from the linac. Energy resolution was in agreement with MC estimates. ADC Electron beam Energy MeV P. Branchini, 30 May 2008

Trigger in Dafne adc2 e+ adc3 adc1 adc4 adc0 adc12 adc11 adc13 adc9 adc5 adc10 adc14 IP adc8 adc6 adc7 e- adc18 adc16 adc19 adc15 adc17 trg(i) = (discriminated) OR of the 5 sectors in the i-th module trg(i) threshold P. Branchini, 30 May 2008

Trigger trg(0) trg(3) trg(2) trg(0) AND trg(1) trg(1) OR IP trg(2) trg(0) AND trg(1) trg(1) OR T1 trg(2) AND trg(3) P. Branchini, 30 May 2008

trg2 AND trg3 trg0 AND trg1 No “wrong” doubles trg1 AND trg2 AND trg3 P. Branchini, 30 May 2008

Background We can have energy deposits over threshold in another module, in addition to the couple of triggering modules: this gives us the “triples” We expect a similar level of events with no Bhabha, but with two “spurious” deposits, giving a fake coincidence P. Branchini, 30 May 2008

Background Si=0,…,4 (ADCi – <PED>i) Bhabha peak Indeed not all the triggering events look like Bhabha events… background P. Branchini, 30 May 2008

Background topology imax(1) = sector with most energy imax(2) = 2nd most energetic sector Diagonals=back-to-back sectors + neighbor 1+1 bunches 100+100 bunches P. Branchini, 30 May 2008

Time Let’s give a look at the time information: t(1) adc(21) Time of single sectors is available We can also use the time of analog sum of the five sectors in each of the 4 modules adc15 … adc19 t(1) threshold adc(21) Passive splitter tdc15 … tdc19 P. Branchini, 30 May 2008 SDS threshold

Trigger time n=3 n=2 n=1 Since we have a multi-hit TDC, we can have more than 1 hit for the 4 modules + 2 coincidences t(0)…t(3) t(4)=time of 0 AND 1 t(5)=time of 2 AND 3 Choose the largest time [the one closest to the COMMON STOP] P. Branchini, 30 May 2008

Bad e+ injections Good e+ injection Bad e+ injections P. Branchini, 30 May 2008

Energy deposit Feb. 2007 first Monte Carlo, 1 e-, 510 MeV Sum of 1 calo module, after pedestal subtraction Triggering module P. Branchini, 30 May 2008

Energy resolution Measured resolution with Bhabha events: 17.5% at 510 MeV, which translates to 12.4%/E(GeV) P. Branchini, 30 May 2008

Conclusions The main design specifications seem to be met in a very satisfactory way… The construction and installation of the detector modules was quick and very effective, thanks to the contribution of many technicians of the Div. Acc. and Div. Ric. Luminosity delivered online, on the basis of our Monte Carlo acceptance, with good accuracy. P. Branchini, 30 May 2008