Lab Report MENG Tao Tsukuba 20,Oct.,2011

Slides:



Advertisements
Similar presentations
Wei Dai Technical Institute of Physics and Chemistry,
Advertisements

The First Law of Thermodynamics
First Law of Thermodynamics - Open Systems
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Jet Engine Design Idealized air-standard Brayton cycle
WACH4 26/11/2002Julien Cogan CERN/EP/CMA-1- M0 COOLING IN H4 Cooling is a key issue : –APD gain : ~ -2.4 % /  C –XTAL response (scintillation) : ~ -1.9.
Selection of measuring instruments
MuCool Absorber Review meeting FermiLab, Chicago 21 – 22 February 2003 Fluid Flow and Convective Heat Transfer Modelling by Wing Lau & Stephanie Yang Oxford.
Gas turbine cycles for aircraft propulsion In shaft power cycles, power is in form of generated power. In air craft cycles, whole power is in the form.
Wind Instrument Testing Apparatus Project WITAP Team: Rob Koch Andy Lawrence.
Effect of Rack Server Population on Temperatures in Data Centers CEETHERM Data Center Laboratory G.W. Woodruff School of Mechanical Engineering Georgia.
© NMISA 2010 INTERNATIONAL ACTIVITIES AT THE NMISA HUMIDITY LABORATORY DURING 2009/2010 Deona Jonker.
Asian Institute of Technology

TURBINE COOLER MAJOR ASSY TURBINE DISC TURBINE DISC IS PART OF THE TURBO COOLER WHICH REDUCES THE TEMPERATURE OF HOT AIR FROM 90±5ºC TO 2ºC.
COOLING & VENTILATION FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 16/9/2009 CLIC TWO BEAM MODULES REVIEW
Morten Karstoft Rasmussen, Danish Technological Institute Metrology for the environment in the Arctic – traceability and data quality for.
Thermal Power Station.
MECH 322 Instrumentation Lab 6 Fluid Speed and Volume Flow Rate Performed: February 27, 2007 Group 0 Miles Greiner Lab Instructors: Mithun Gudipati, Venkata.
ME 391 Instrumentation LAB #6 Volume Flow Rate and Centerline Speed in a Tube Wind Tunnel Performed: 03/05/2004 Soma: I believe I performed 50% of this.
Euromet-meeting in Thessaloniki - March FORCE Technology Building up a high-pressure loop in FORCE Technology Historic: The investment.
Bernoulli Equation – Pitot tube  Horizontal  Velocity at stagnation point is 0  Incompressible fluid  Steady state  Velocity as function of pressure.
1 Gas Billing KRISS Kyung-Am Park. 2 KRISS Fluid Flow Group  High pressure gas flow Lower than 10,000 m3/h, 0.18% % 10,000 m3/h ~ ??,
AirSpeed Calibration Facility by using LDV and A Wind Tunnel at CMS
All-Russia D.I. Mendeleyev Scientific and Research Institute for Metrology (Vniim) (FGUP "D.I.Mendeleyev VNIIM") Konstantin Popov
High Accuracy Lab in the Private Sector Doug Cooper.
Progress Report of NPLI Fluid Flow Measurement Standards Activity ( ) Shiv Kumar Jaiswal Senior Scientist Fluid Flow Measurement Standards (Apex.
1 Key Comparison CCM.FF-K6b Comparison of the Primary (National) Standards of Low Pressure Gas Flow WGFF meeting, June, 19, 2012, Colorado Springs, USA.
APMP TCFF Country Report CMS/ITRI, Chinese Taipei Chun-Min Su, Ph.D. Dec. 5, 2011 Kobe, Japan.
APMP TCFF Workshop Nov. 22, Investigation on calibration of fuel ethanol flow meters Takashi Shimada, Ryouji Doihara, Noriyuki Fuiichi, Yoshiya.
APLMF 12 VOLUME AND FLOW LABORATORY OF VMI APPLYING PROCESS FOR CMC Dr Nguyen Hong Thai Volume and Flow Lab- VMI 6/25/
Mass and Energy Analysis of Control Volumes Chapter 5a.
Ullrich, DESY Dubna GDE XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser 1 Water cooling XFEL Desingn of the XFEL water cooling.
APMP TC Fluid Flow Initiative Project Traceability Scheme Study for LPG Metering Final Report at APMP 2012 TCFF Meeting Chun-Min Su CMS/ITRI, Chinese Taipei.
704 MHz cavity design based on 704MHZ_v7.stp C. Pai
APMP TC Fluid Flow Initiative Project Traceability Scheme Study for LPG Metering Progress Report at APMP 2011 TCFF Meeting Chun-Min Su, Ph.D. Center for.
APMP TCFF meeting 2011 Updates for National Metrology Centre of A*STAR Wu Jian National Metrology Centre A*STAR 7 July 2011.
A New Calibration Facility for Small Flow of Hydrocarbon Liquid
1 Chapter 5 Mass and Energy Analysis of Control Volumes.
Thermally managing high power devices using heat pipe assemblies
First Law of Thermodynamics applied to Flow processes
Chapter: 06 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES.
air cycle cooling systems
Introduction of Liquid Flow Standards Section Fluid Flow Division National Metrology Institute of Japan (NMIJ)
The Windy Window an Economic and environment friendly air-cooler
News from the Working Group on Fluid Flow
LAB #6 Volume Flow Rate and Centerline Speed in a Tube Wind Tunnel
Introduction of NMIJ Gas Flow Standards Section
Air Volume Flow Rate and Centerline Velocity in a Tube Wind Tunnel
Chapter 5 The First Law of Thermodynamics for Opened Systems
Wind Tunnel Design Replicating Offshore Winds
S. Ghosh, M. Muste, M. Marquardt, F. Stern
REPORT OF RECENT ACTIVIES
Chapter 5 Mass and Energy Analysis of Control Volumes Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 6th edition.
CMC submission from A to Z
TC-Flow 2014/2015 Activities and Highlights
Report from TCFF kyung-Am Park TCFF Chair
Mass and Energy Analysis of Control Volumes (Open Systems)
Status Report of the CCM KCs
TECHNICAL TRAINING 2007.
Progress Report of APMP.M.FF-K2b
The upstream effect on back pressure ratio
By: JAGDEEP SANGWAN Refrigeration Basics 101.
CBE 465 4/7/2019 Heuristics “Rules of Thumb”.
4 CHAPTER The First Law of Thermodynamics: Control Volumes.
Numerical Investigation of Hydrogen Release from Varying Diameter Exit
Then cut lines (top sheet only!)
Thermohydraulic behaviour of the cryogenic system
Presentation transcript:

E-mail: mengt@nim.ac.cn Lab Report MENG Tao Tsukuba 20,Oct.,2011 National Institute of Metrology, P.R.China E-mail: mengt@nim.ac.cn

Progress of NIM’s new flow facilities New air speed facility Hot water flow facility Hydrocarbon flow facility High pressure gas flow facility As you kwon, NIM has a new campus in Changping of Beijing. Some new flow facility is being built or preparing to build. I am very glad to report the progress of these new flow facilities that include air speed facility ……

Progress of NIM’s new flow facilities New air speed facility Hot water flow facility Hydrocarbon flow facility High pressure gas flow facility Finish

LDA & Wind Tunnel System Air speed facility Finish Cooperation with CMS This facility had finished at the end of last year. It is a LDA & wind tunnel system. Test range: (0.2~35)m/s. We have cooperation with CMS on this facility. The expert of CMS, like Dr. Yang give us lot of help. They have abundant experience. LDA & Wind Tunnel System Test range: (0.2~35)m/s Test section: 1000mm×800mm×800mm

Air speed facility LDA Dantec company Specification Expanded uncertainty Urel<0.2%,k=2 → Spinning disc system LDA (1)3D velocity (Green, blue, Purple; λ=514.5nm,488nm,476nm) (2)Particle diameter measurement; (1~100) μm Tracing particle ACETONE C3H6O(ρ= 0.788 g/ml) LDA was made by Dantec company. It is a 3D measurement system, and it has a water cooling system. ACETONE is used as tracing particle. The U of speed measurement is better than 0.2% after calibrated by spinning disc system.

Air speed facility Wind Tunnel Setting chamber inlet diameter = 600mm Nozzle outlet diameter = 200mm Contraction ratio = 9 Diffuser inlet diameter = 300mm Axial Flow Fan

Air speed facility Wind Tunnel Development of spinning disc Value (m/s) Particle tracing effects Length(m) Time(s) 转盘校准系统(0.1%,k=2) Spinning-disc(0.1%,k=2) Spinning-disc (0.1%,k=2) 转盘校准系统(0.1%,k=2) 转盘校准系统(0.1%,k=2) 转盘校准系统(0.1%,k=2) 转盘校准系统(0.1%,k=2) 转盘校准系统(0.1%,k=2) Primary standard Primary standard LDA+ Wind tunnel (0.2%,k=2) Stability of anemometry Block effects Secondary standard Pitot-tube My colleague has done many test on this LDA+wind tunnel facility this year. To solve the problem of traceability of LDA, a new spinning disc system will be developed. This work will be finished next year. Meter Anemometry

Progress of NIM’s new flow facilities New air speed facility Hot water flow facility Hydrocarbon flow facility High pressure gas flow facility Finish Building

Hot water flow facility A2 Items Content Flow Range (0.8~600)m3/h Pipe Size DN80~DN200 Temperature Range 5℃~90℃ Uncertainty 0.05%, k=2 A1 Items Content Flow Range (0.03~40)m3/h Pipe Size DN15~DN80 Temperature Range 5℃~90℃ Uncertainty 0.05%, k=2 A2 I had introduced this project in the last meeting. This facility include two weighting-diverter rig. 流量范围,温度范围,0.05% A1

Hot water flow facility B2 B1 B1 Content Flow Range (0.03~40)m3/h Pipe Size DN15~DN80 Temperature Range Ambient-temperature ~ 55℃ Uncertainty 0.2%, k=2 And two master meter calibration rig. Max flow rate 1500, but T is 55. B2 Content Flow Range (1.6~1500)m3/h Pipe Size DN80~DN400 Temperature Range Ambient-temperature ~ 55℃ Uncertainty 0.2%, k=2

Hot water flow facility Location in Beijing Heat Group Company Some Problems A1 Items Content Flow Range (0.03~40)m3/h Pipe Size DN15~DN80 Temperature Range 5℃~90℃ Uncertainty 0.05%, k=2 The whole design had completed at the beginning of this year, but we encountered a problem that building the house of this lab is late than our prediction. That facility will locate in Heat group company. They hope the new building will be finished before May in the next year. Small size facility A1 has temporary been assembled in the Changping campus of NIM. So I am busy for this facility recently. When I return to NIM after APMP meeting, I will do some test and experiment on it.

Progress of NIM’s new flow facilities New air speed facility Hot water flow facility Hydrocarbon flow facility High pressure gas flow facility Finish Building Building

Hydrocarbon flow facility Building in new campus of NIM Max Flow rate : 120m3/h Max pipe diameter :100mm Viscosity < 21 mm2/s Uncertainty < 0.05% Same government Energy measurement plan. Building in new campus of NIM. 主要指标。This facility include 2 type of standard which are gravimetric method and pipe prover.

Hydrocarbon flow facility Mostly equipment has reached the lab, and assembly and adjustment will be done in next year.

Progress of NIM’s new flow facilities New air speed facility Hot water flow facility Hydrocarbon flow facility High pressure gas flow facility Finish Building Building Preparing

High pressure gas flow facility Turbine meter as master meter The max flow rate is 1600m3/h at 2.5MPa Sonic nozzle as master meter The max flow rate is 400m3/h at 2.5MPa The current 2m3 pVTt facility The max flow rate is 40m3/h at 2.5MPa Primary standard Secondary standard Working standard There are several gas flow facility in our lab. But they are all low pressure gas flow facility ,like bell prover, piston prover and pVTt rig. So a high pressure rig is in the plan. The primary standard is still pVTt facility. We hope to improve the pressure of the rig form 0.4 Mpa now to 2.5. Sonic nozzle can be used as secondary standard, and turbine meter is the working standard. Max flow rate: 1600 Flow increasing

High pressure gas flow facility Close loop system Budget : $ 3 million Location : new site of NIM Wind tunnel facility Room 1007 Room 1012, The new pVTt location Room 1011, The old pVTt location A draft of a close loop system has been designed recently. 3million .We hope we can get budget support from government next year. We expect this facility will be complete in next 2-3 years. Room 1010

Progress of NIM’s new flow facilities New air speed facility Hot water flow facility Hydrocarbon flow facility High pressure gas flow facility Finish Building Building Preparing Finally, I will introduce our some plan of comparison and CMCs. Plan of comparison and CMCs

Plan of comparison and CMCs Facility Comparison CMCs Water flow finish 2012 Low pressure gas flow Technical comparison 2012-2013 Air speed 2012 or 2013 2014 Hot water flow 2013-2014 2014-2015 Hydrocarbon flow High pressure gas flow 2015? 2016? Low pressure —— we have 2 TC with NIST and PTB. For the new facility we also hope participate some KC or bilateral comparison and apply more CMCs in the future.

Thanks