William Lipps Analytical & Measuring Instrument Division August 2017

Slides:



Advertisements
Similar presentations
Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
Advertisements

Quality is a Lousy Idea-
ENVIRONMENTAL ANALYSIS I. Solid Phase Extraction columns vs. disks.
Lab Methods Day June 25, 2014 Gas Chromatography
Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
Mentoring Session Technical Assistance Committee Method Modifications.
Pesticide screening LC-QTOF, Agilent. National Food Institute, Technical University of Denmark Disposition National Food Institute –EURL –NRL –Personale.
P. 1 FAQs- before analyzing your sample. p. 2  Temperature (thermal degradable?)  Split or splitless  Split ratio  Injection volume FAQs- injection.
Interpreting Your Lab Report & Quality Control Results
Detect Limits as Representation for a Standard VAP Rule Discussion Dawn Busalacchi Risk Assessor, DERR, Central Office VAP Rule Discussion Dawn Busalacchi.
Laboratory requirements Dioxin Workshop, Leon Mexico Richard Turle Analysis and Air Quality Division Environmental Science and Technology Centre Environment.
Tandem Mass Spectrometry Newborn Screening Quality Assurance and Control Instrument and Method Validation Gary Hoffman Wisconsin Newborn Screening Laboratory.
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
Field Analysis Quality Control
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
Laboratory Technical Issues Presentation to: KWWOA April 9, 2014 Department for Environmental Protection Environmental & Public Protection Cabinet To Protect.
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek – Applications Chemist.
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
“ANALYSIS OF CURRENT USE PESTICIDES IN ENVIRONMENTAL AND WASTEWATER SAMPLES BY HIGH RESOLUTION GC WITH HIGH RESOLUTION MASS SPECTROMETRIC DETECTION” Richard.
Understanding Your QC Presentation to: KWWOA April 15, 2015 Department for Environmental Protection Energy & Environment Cabinet To Protect and Enhance.
HP Labs Escondido, CA Methanol and Ethanol Analysis/ J. Picker The Ultimate Gourmet Martini.
Wastewater Laboratory Certification Presented at: KWWOA April17,
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
Quality Assurance How do you know your results are correct? How confident are you?
Polybrominated diphenyl ethers by HRGC/HRMS Coreen Hamilton Brian Fowler Louis Haviland Axys Analytical Services, Ltd.
Analytical Separations
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Aroclor Analysis and the Challenge of Matrix Interference “Using a Holistic approach in the Laboratory to analyze uncommon matrices with Confidence and.
EQUIPMENT and METHOD VALIDATION
John D. Vargo 1 ; Michael Schueller 1 ; Mary Skopec 2 1 State Hygienic Laboratory at the University of Iowa, Coralville, IA; 2 Iowa Department of Natural.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
QUALITATIVE Chemical Analysis
Overview CWA Methods Update Rule Method 608.3
Multi-Analyte LC-MS/MS Methods – Best Practice.
The Method Update Rule Does this affect me? HOW?
Determination of TKN by Subtraction using ASTM D and ASTM D
Quality is a Lousy Idea-
An integrated GC-MS workflow solution for the determination of (semi)volatiles in drinking water and solid waste according to the U.S. EPA guidelines B.
James Byrd, Marta Kozak 28 Apr 2011
Clean Water Act Methods Overview of EPA’s CWA Method Activities
Chem. 133 – 5/11 Lecture.
Method Modifications & ATP 40 CFR part and 136.5
EPA Method A Summary of the Changes in the Newly Promulgated GC/MS Method for Volatile Organics in Wastewater Harry McCarty and Kevin Roberts CSRA,
Automation of Sample Preparation for Trace Analysis Haibin Wan
EPA Method Equivalency
Janice L. Willey Senior Chemist
William Lipps, Brahm Prakash
Developing a Consensus Test Method for Measuring Volatile Organic Compounds (VOCs) in Water utilizing Headspace Analysis with Gas Chromatography and Mass.
Added Monrovia and South Bend to the slide.
The Use of Advanced Instrumental Techniques to Address Emerging and Unique Circumstance Contaminants Charles Neslund, Scientific Officer, Eurofins Lancaster.
The Analysis of Soils and Waters in Accordance with U. S
Have Instrument, make method; How new methods are made and validated
Quality is a Lousy Idea-
Update on ASTM and Standard Methods method development activities
Clean Water Act Methods Overview of EPA’s CWA Method Activities
EPA Method Equivalency
Director of Quality Assurance
Brahm Prakash Tairo Ogura and William Lipps
Presentation Title NEMC 2018 Dale Walker, Bruce Quimby Agilent
Presentation Title 11/28/2018 Confidentiality label
Environmental Laboratory Certification Program (ELCP)
Best Practices for Calibration and Calibration Verification
Best Practices for Identification and Quantitation
Insert Presentation Title Here Insert Presentation Summary Here
TCEQ Environmental Trade Fair Water Quality Division
SW-846 Methods Program Update and Path Forward
American Council of Independent Labs
Presentation transcript:

William Lipps Analytical & Measuring Instrument Division August 2017 EPA Method 625.1 - A Summary of the Changes in the Newly Promulgated GC/MS Method for Semi-Volatile Organics in Wastewater William Lipps Analytical & Measuring Instrument Division August 2017

AKA = 11+ things you need to know about the revised method EPA 625.1

REVISED  no new Inter-lab study Method data still based on 1984 Study Priority pollutants LLE Packed Columns Separate Acids and B/N  special columns 3 point calibration Full scan MS

Method 625 will be Method 625.1 Table 1  38 base neutral Table 2  11 acid extractable Each Table lists MDL and ML ML = 3 times MDL MDL = 1984 MDL

Table 3 list 316 analytes MDL 303 have no MDL or ML data 13 are priority pollutant pesticides and PCB’s These have MDL and ML data 303 have no MDL or ML data YOU must establish your own MDL

“Cutting edge” – You can now use Capillary columns Capillary columns in text Examples given EI and CI in Table 4 for priority pollutants Includes quant and secondary ions Retention times (elution order) No Quant ion, secondary ion, or retention time data for the 303 new analytes in Table 3

RSE ≤ 35%

Table 8 provides 38 surrogates or internal standards No quant ions or secondary ions No retention times Internal Standard response 50 – 200% CCV = second source standard Method Study 30  no correlation of SS with analytes found

Solid Phase Extraction is allowed Individual lab or Vendor MUST validate Table 1 and Table 2 Spiked MS/MSD complete list, 4 IDC, 1 PT Up to 9 matrices, depending MDL (lab must do) Must fortify with surrogates Must meet 625 criteria for Table 1&2, or 60 – 140% for Table 3 https://www.epa.gov/cwa-methods/alternate-test-procedures

100 – 1000 ml sample size Smaller sample volume = better for SPE Extract less means use less reagent New instruments can detect lower

One calibration Standard must be at ML Or as specified in a permit Or your own as long as lower than Table 1 or Table 2 ML Table 3 has no ML (develop your own)

DFTPP tune criteria more flexible, by footnote Adds TOF criteria as Table 9B TOF criteria wider 442 can be base peak

Can do Selected Ion Monitoring (SIM) No qualitative ion criteria for SIM Do not need to tune (for SIM)  assumes SIM for all analytes SIM MRM

Can use Hydrogen as a carrier gas No tune criteria Must meet method QC acceptance criteria

New Quality Control Criteria No closing CCV Limits is Table 6 (Q) as broad as 13 – 200% 5 – point calibration curve  minimum DOC per lab, not analyst

Matrix spikes Data user chooses sample to spike If spike fails that analyte cannot be reported

Sample injection split Splitless Large volume injector On-column injection Use whatever volume works Must be same for samples as standards

Thank You wclipps@shimadzu.com When using this template, please refer to comments here and the “Disclaimer_Guidance_of_The_Technical_Presentations_20160630” pdf enclosed together in this zip file.