Comparison of 2.3 & 5 mega pixel (MP) resolution monitors when detecting mammography image blurring.  Borgen R, Ma V, Kelly J, Scragg B, Aspin R, Millington.

Slides:



Advertisements
Similar presentations
Introduction Radiostereometry (RSA) is well established research method for assessing movement of orthopaedic implants, bone fractures, and.
Advertisements

Digital Image Manipulation I By Professor Stelmark.
Methods Methods ConclusionConclusion Improving Image Quality of Digital Mammographic Images Using an Undecimated Discrete Wavelet Transform Method: Performance.
Software Quality Control Methods. Introduction Quality control methods have received a world wide surge of interest within the past couple of decades.
Signal Analysis and Processing for SmartPET D. Scraggs, A. Boston, H Boston, R Cooper, A Mather, G Turk University of Liverpool C. Hall, I. Lazarus Daresbury.
Breast Cancer Screening, Family History Assessment and New Innovations Miss Karina Cox Consultant Breast and Oncoplastic Surgeon.
Chemometrics Method comparison
Background The 2 week wait referral system was designed to expedite the referral of patients, suspected to have cancer, from Primary to Secondary care.
Statistics in Screening/Diagnosis
ACRIN Breast Committee Fall Meeting : Comparison of Full-Field Digital Mammography with Digital Breast Tomosynthesis Image Acquisition in Relation.
The Effect of Initial Posture on The Performance of Multi-Joint Reaching Tasks: A Comparison of Joint Excursions Between Individuals With and Without Chronic.
IMRT QA Plan Site 5%/3mm3%/3mm2%/2mm 0% noise1% noise2% noise0% noise1% noise2% noise0% noise1% noise2% noise HN
Make observations to state the problem *a statement that defines the topic of the experiments and identifies the relationship between the two variables.
Dose Interruption/Reduction of Tyrosine Kinase Inhibitors in the First 3 Months of Treatment of CML Is Associated with Inferior Early Molecular Responses.
Economic evaluation of health programmes Department of Epidemiology, Biostatistics and Occupational Health Class no. 19: Economic Evaluation using Patient-Level.
3/2003 Rev 1 I.2.12 – slide 1 of 18 Part I Review of Fundamentals Module 2Basic Physics and Mathematics Used in Radiation Protection Session 12Statistics.
Copyright © Cengage Learning. All rights reserved. 12 Analysis of Variance.
Quality control & Statistics. Definition: it is the science of gathering, analyzing, interpreting and representing data. Example: introduction a new test.
Does Anxiety Vary by Gender and Race During Adolescence? Alyson Cavanaugh, Kelly A. Cheeseman, and Christine McCauley Ohannessian University of Delaware.
Conclusions Despite being able to acquire successfully high resolution images of radiation dose, image quality is limited by hardware problems. Upgrading.
Some Difficult Decisions are Easier without Computer Support / TA Mammography, RT Diversity / Andrey A. Povyakalo (work together with E Alberdi, L Strigini.
 An exposure-response (E-R) analysis in oncology aims at describing the relationship between drug exposure and survival and in addition aims at comparing.
Advanced Higher Biology Unit 3 Investigative Biology.
Two-week wait referrals for malignant melanoma: A clinical audit carried out across four UK Cancer Networks South West Cancer Intelligence Service
AP Stat 2007 Free Response. 1. A. Roughly speaking, the standard deviation (s = 2.141) measures a “typical” distance between the individual discoloration.
Imaging: Images were obtained over a range of tube potentials (81 to 125 kV) without scatter rejection, with a stationary anti- scatter grid and using.
Thursday Case of the Day History: The hypothetical results from a clinical trial of computer-aided detection (CADe) used in mammographic screening of 5,000,000.
Practitioner Variation of applied Compression Force in Mammography Claire E. Mercer MSc, BSc(hons)
The Royal College of Emergency Medicine Assessing for Cognitive Impairment in Older People Clinical Audit National findings The Royal College of.
The Royal College of Emergency Medicine Mental Health in the ED Clinical Audit National findings The Royal College of Emergency Medicine Clinical.
References : [1] Hurkmans CW, et al Set-up verification using portal imaging; review of current clinical practice. Radiother. Oncol. 2001;58: [2]
» In order to create a valid experiment, the experimenter can only change ONE variable at a time » The variable that is being changed by the experimenter.
Clinical practice involves measuring quantities for a variety of purposes, such as: aiding diagnosis, predicting future patient outcomes, serving as endpoints.
Quality issues in monitoring diagnostic and treatment performance Dr
Image Reading Course in Nuclear Medicine
Number of women referred for further investigation in relation to all imaged women – recall rate
UOG Journal Club: January 2016
Tips for Inserting Graphs or Images Tips for Title/Headers Bar Color
The Role of the Consultant Radiographer in Diagnostic Imaging Services in the United Kingdom and Barriers to their practice. Authors: Jack Williams and.
Introduction To compare data sets, use the same types of statistics that you use to represent or describe data sets. These statistics include measures.
University of Ulster, School of Life and Health Sciences.
Developing the Overall Audit Plan and Audit Program
How many study subjects are required ? (Estimation of Sample size) By Dr.Shaik Shaffi Ahamed Associate Professor Dept. of Family & Community Medicine.
Date of download: 11/2/2017 Copyright © ASME. All rights reserved.
Treatment With Continuous, Hyperfractionated, Accelerated Radiotherapy (CHART) For Non-Small Cell Lung Cancer (NSCLC): The Weston Park Hospital Experience.
Height and Pressure Test for Improving Spray Application
Chapter 2 Simple Comparative Experiments
39 DEVELOPED HCC by EASL criteria
The impact of simulated motion blur on lesion detection performance in Full Field Digital Mammography Ahmed K. Abdullah1,2, John Thompson2, Claire Mercer2,
Hayley Milne & Andrew England
CHAPTER 3 Data Description 9/17/2018 Kasturiarachi.
Introduction to Inferential Statistics
Inverse Transformation Scale Experimental Power Graphing
Practical clinical chemistry
Hypothesis Theory examples.
Monitoring rare events during an ongoing clinical trial
Warm-up 8/25/14 Compare Data A to Data B using the five number summary, measure of center and measure of spread. A) 18, 33, 18, 87, 12, 23, 93, 34, 71,
Volume 24, Issue 3, Pages (August 2018)
Quality Assurance Reference Intervals.
Comparing two Rates Farrokh Alemi Ph.D.
Chi Square (2) Dr. Richard Jackson
Introduction Previous lessons have demonstrated that the normal distribution provides a useful model for many situations in business and industry, as.
Writing the IA Report: Analysis and Evaluation
Interpreting Basic Statistics
Assessing for Cognitive Impairment
Quality Control Lecture 3
Wednesday Case of the Day
Skills 5. Skills 5 Standard deviation What is it used for? This statistical test is used for measuring the degree of dispersion. It is another way.
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Glucose levels must be monitored in patients receiving steroids for immunotherapy-related toxicity Title: Subtitle Risk Assessment of Hyperglycaemia Induced.
Presentation transcript:

Comparison of 2.3 & 5 mega pixel (MP) resolution monitors when detecting mammography image blurring.  Borgen R, Ma V, Kelly J, Scragg B, Aspin R, Millington S, Lanca C and Hogg P DISCUSSION The results from this study confirm that a monitor with lower resolution (2.3 MP) would likely have a poorer visual detection rate for FFDM image blurring compared with a higher resolution reporting grade monitor (5.0 MP) and is confirmed by the difference in technical recall rates. In clinical practice some monitors have resolutions as low as 1 MP, and we assume that such monitors would have even poorer visual detection rates than a 2.3 MP monitor, thereby leading to even more technical recalls. On examining practitioner ability to visually detect blurring on a 5 MP monitor (Table 3), using our dataset of 120 images, we propose that the 75th percentile should be used for the minimum standard for educational and clinical purposes. One of the limitations of this study is the use of motion simulated images as they may not be fully representative of real blurring. The version of software used in this study only blurs the whole image while real mammography image blurring may fully or partly affect the image. An update to our software has the ability to introduce regional blurring. Using this updated software further studies could be carried out to investigate the effect of regional blurring on the blurring detection rate. Monitor resolution is one of the factors which might affect the visual detection of blurring. Other factors, such as contrast resolution, room brightness and visual acuity might also affect the ability of observers to visually detect blurring. ABSTRACT Background Image blurring in Full Field Digital Mammography (FFDM) is reported to be a problem within many UK breast screening units resulting in significant proportion of technical repeats/recalls. Our study investigates monitors of differing pixel resolution, and whether there is a difference in blurring detection between a 2.3 MP technical review monitor and a 5MP standard reporting monitor. Methods Simulation software was created to induce different magnitudes of blur on 20 artifact free FFDM screening images. 120 blurred and non-blurred images were randomized and displayed on the 2.3 and 5MP monitors; they were reviewed by 28 trained observers. Monitors were calibrated to the DICOM Grayscale Standard Display Function. T-test was used to determine whether significant differences exist in blurring detection between the monitors. Results The blurring detection rate on the 2.3MP monitor for 0.2, 0.4, 0.6, 0.8 and 1 mm blur was 46, 59, 66, 77and 78% respectively; and on the 5MP monitor 44, 70, 83 , 96 and 98%. All the non-motion images were identified correctly. A statistical difference (p <0.01) in the blurring detection rate between the two monitors was demonstrated Conclusions Given the results of this study and knowing that monitors as low as 1 MP are used in clinical practice, we speculate that technical recall/repeat rates because of blurring could be reduced if higher resolution monitors are used for technical review at the time of imaging. Further work is needed to determine monitor minimum specification for visual blurring detection. INTRODUCTION Image blurring due to motion unsharpness in Full Field Digital Mammography (FFDM) is a widely recognized problem and various explanations exist about how it occurs [1, 2]. One explanation is breast/paddle movement whilst the exposure is being made [1-4]. Technical recalls due to blurring also has the potential to increase false negative and false positive results. Repeat imaging increases client radiation dose, overall examination time and can raise client anxiety. In 2000 Seddon et al. reported that over 90% of their screening mammogram technical recalls were due to blurred images [5]. More recently blurred images were found to be a major source of technical recall [6]. Audit in one of our breast screening units found that 0.86% of clients were recalled due to image blur; this contributed approximately one third (29%) of the 3% maximum permissible recall rate in the National Health Breast Screening Programme (NHSBSP) [7]. For some images blurring could only be detected when they were displayed on 5 mega pixel (MP) reporting grade monitors at the time of reporting. Blurring was missed when the images were checked for technical accuracy on the lower specification technical review monitors. Our study aims to investigate: whether there is a difference in visual detection of blurring between a 2.3 MP technical review monitor and a 5 MP reporting grade monitor; and to propose an observer standard for the visual detection of blurring on reporting grade 5 MP monitors. METHODS Twenty eight radiographers qualified in mammography imaging from two breast screening units were invited to review 120 blurred and non-blurred images on a 2.3 MP technical review monitor and a 5.0 MP reporting grade monitor. Selection of FFDM images Using published quality criteria [8], two experienced image readers independently reviewed several hundred images to identify an initial set of 100 normal artifact free FFDM images. Mathematical simulation software [3] was used to simulate the effect of motion in 20 FFDM images, thereby creating simulated blur. Simulated blurring was imposed from 0.2 to 1.0 mm at 0.2 mm increments. In total 120 images were used, comprising 20 with no blur and 100 with varying levels of simulated motion and therefore blurring (0.2mm (20); 0.4mm (20); 0.6mm (20); 0.8mm (20) and 1.0mm (20)). Figures 1 and 2 show examples of FFDM images with and without simulated blur imposed. RESULTS The average blurring detection rate for the 2.3 and 5 MP monitors are shown in Figure 3. All the non-motion images were identified correctly. Blurring detection rate increases with simulated motion and monitor resolution. The 5 MP monitor has a higher average blurring detection rate. Figure 3: Blurring detection rate against level of motion, the error bars represent the standard deviation. . Fig 1 FFDM image with no blur Fig 2 FFDM image with 1mm simulated blur For 0.2 mm motion, there is no significant difference (p=0.20) in blurring detection between the 2.3 and 5 MP monitors, For motion larger than 0.2 mm there is significant difference (X2 (1, N = 5475) =110.07, p<0.05) in blurring detection between 2.3 and 5 MP monitors. The technical recall rate for 2.3 and 5 MP monitors at each level of motion were calculated and summarized in Tables 1 and 2. Technical recall rate appears directly related to the level of motion and inversely related to monitor resolution. The technical recall rate for the 2.3 MP monitor varies from 3.6% to 9.1% and for the 5 MP monitor it varies from 0.3% to 9.8%. The 2.3MP monitor has a higher overall technical recall rate (29.5%) compared to 5MP monitor (18.9%). CONCLUSION Monitors equal to or below 2.3 MP are probably not suitable for technical review of FFDM images for the detection of blur. Further research is needed to identify the minimum monitor specification for technical review in clinical rooms for blur detection. Using our image dataset, minimum standards for blur detection at 0.4, 0.6, 0.8 and 1 mm level of simulated blurring are 96, 100, 100 and 100%. The minimum amount of motion required for visual detection of blurring is 0.4mm. This information could be used to help inform competence assessment standards of radiographers in training programmes and routine practice. Table 1: Technical recall rate for 2.3MP monitor Level of motion (mm) 0.2 0.4 0.6 0.8 1 Total Technical recall rate 9.1% 7.1% 5.8% 3.8% 3.6% 29.5% The 120 images were de-identified, randomized and displayed on 2.3 MP (NEC, Multisync EA248wm) and 5 MP (NDS, Dome ES Ci5) monitors. Both Monitors were calibrated to the DICOM Grayscale Standard Display Function [9] Images were displayed using MediViewer (Schaef Systemtechnik, Petersaurach, Germany) and viewed at approximately 75 cm from the monitor on a blinded basi by the 28 radiographers. Radiographers were not permitted to manipulate the images or adjust the brightness and contrast of the images. Data collection took 8 months to complete with a period of 2 months between each monitor review. Chi-square was used to test whether significant differences in blurring detection existed between the 2.3 and 5 MP monitors. Table 2: Technical recall rate for 5MP monitor Level of motion (mm) 0.2 0.4 0.6 0.8 1 Total Technical recall rate 9.8% 5.1% 2.9% 0.8% 0.3% 18.9% REFERENCES 1. Ma WK, Brettle D, Howard D, Kelly J, Millington S, Hogg P. Extra Patient Movement During Mammographic Imaging: An Experimental Study. Br J Radiol 2014; 87(1044):20140241. DOI: 10.1259/bjr.20140241. 2. Ma WK, McEntee MF, Mercer CE, Kelly J, Millington S, Hogg P. Analysis of motion during the breast clamping phase of mammography. Br J Radiol 2016; 89: 20150715. DOI: 1 10.1259/bjr.20150715 3. Ma WK, Aspin R, Kelly J, S. Millington, Hogg P. What is the minimum amount of simulated breast movement required for visual detection of blurring? An exploratory investigation. Br J Radiol 2015; 88: 20150126. DOI: 10.1259/bjr.20150126 4. Ma WK, Hogg P, Kelly J, Millington S. A method to investigate image blurring due to mammography machine compression paddle movement. Radiography 2014; in press. Epub ahead of print. doi: 10.1016/j.radi.2014.06.004 5. Seddon D, Schofield K A, Waite C A. Investigation into possible caused of blurring in mammograms. Breast Cancer Res. 2000; 2(suppl2): A64. DOI: 10.1186/bcr253 6. O’Rourke J, Mercer CE, Starr L. Programme evaluation: Technical recall and image blur within a breast screening service. Symposium Mammographicum 2014, UK: Bournemouth, 2014. 7. NHS Cancer Screening Programmes. Consolidated guidance on standards for the NHS Breast 240 Screening Programme. NHSBSP Publication No 60 (Version 2), UK: Sheffield, 2005. 8. Perry N, Broeders M, Wolf C, Törnberg S, Holland R, Karsa L. European guidelines for quality assurance in breast cancer screening and diagnosis. 4th ed. Luxembourg: European Communities, 2006. 9. National Electrical Manufacturers Association (NEMA) Digital Imaging and Communications in Medicine (DICOM) Part 14: Grayscale Standard Display Function; 2011. Table 3 indicates the median, upper quartile and lower quartile increases with the level of motion. The minimum amount of motion required for visual detection of blurring is 0.4 mm and the minimum standards for blur detection at 0.4, 0.6, 0.8 and 1 mm are 96, 100, 100 and 100% respectively. Table 3: Median, lower quartile and upper quartile of blurring detection for 5 MP monitor Level of motion (mm) 0.2 0.4 0.6 0.8 1 Lower quartile (25th percentile) 10% 50% 74% 94% 100% Median 28% 70% 85% 98% Upper quartile (75th percentile) 68% 96% For additional information please contact: Mrs. Rita Borgen Breast Screening Unit East Lancashire Hospitals Trust Rita.borgen@elht.nhs.uk